• Title/Summary/Keyword: Ondol Heating System

Search Result 113, Processing Time 0.028 seconds

A Study on the Bed Climate and the Physiological Responses in Sleep. - On Ondol Environment - (수면시 침상기후와 인체생리반응에 관한 연구 -온돌환경을 중심으로-)

  • Kim Myung Ju;Choi Jeong Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.2 s.38
    • /
    • pp.77-87
    • /
    • 1991
  • The purpose of this study were to investigate the bed climate and the physiological responses in sleep on the traditional Korean floor heating system called Ondol. Ondol has been the most widely used heating system in Korea, yet there has been a no systematic studies examined its environmental effects on human body. Experimental room was constructed to match the typical thermal environment of Ondol. (floor surface temperature; $32\~33^{\circ}C$, air temperature; $22.5{\pm}1.0^{\circ}C$, relative humidity; $64.0{\pm}4.0\%$RH, air velocity; 0.25 m/sec.) Three different combinations of bedclothes were chosen for the experiment based on the study results showing that they were the most widely used types in Korea. Type 1 was the combination of a cotton-padded mattress with a cotton-padded Korean style blanket. Type 2 was a cotton-padded mattress with a cotton-guilted Korean style blanket. Type 3 was a cotton-padded matless with a polyacryl blanket. Thermal resistance of each of these combina-tions in the bedclothes was measured using thermal manikin. Two adult female was chosen for the seven hour sleeping experiment which was known to be the average sleeping hours of Korean adult female. The bed climate was measured with the temperature under the mattress, the surface temper-ature of the mattress, and the air temperature and the relative humidity of the space between the mattress and blanket. The skin temperature, rectal temperature of the subjects and the bed climate were measured eight times, one hour before the experiment and every hour during the experiment. The weight loss and the subjective sensation were measured for the each subjects before and after the experiment. The procedure was repeated twice with two subjects and three types of bedclothes, yielding twelve combinations of results. The results were as follows; 1. With the surface temperature of $32\~33^{\circ}C$ of Ondol, air temperature was $22.5{\pm}1.0^{\circ}C$ with $64.0{\pm}4.0\%$ RH. The bed climates were $39.2{\pm}40.8^{\circ}C$ under the mattress, $35.3\~36.2^{\circ}C$ on the mattress, and $26.9\~32.0^{\circ}C$ with $56.0\~71.3\%$ RH between the mattress and the blanket. 2. Mean skim temperature during sleep was 34.2"C with local skin temperature of $34.0\~35.5^{\circ}C$. The skin temperatures of abdomen, thigh, foot were higher than the other parts of the body. 3. The skin temperature of chest, thigh, leg and back varied significantly according to the combinations of bedclothes. With the cotton-padded blanket, the skin temperature was the highest, while with the cotton-guilted blanket showed lowest. 4. Examining the relationship between the mean skin temperature and the local skin temper-ature, the chest temperature showed the highest correlation with the former. Therefore, the chest temperature can be recommended to represent the skin temperature in measuring the bed climate. 5. The subjective bed climates were $39.0\~40.4^{\circ}C$ under the mattress, $35.2\~35.9^{\circ}C$ on the mattress, $29.8\~31.6^{\circ}C$ with $56.8\~68.4\%$ RH between the mattress and blanket. In sum, from this experiment we not only obtained the reliable value of bed climates on Ondol, but also showed that the bed climates and the physiological responses were affected differently according to the materials of bed clothes.

  • PDF

A Study on the Dry-Shrinkage Properties For Floor Mortar With Crack-Reducing (균열저감형 바닥마감전용 모르터의 건조수축특성 연구)

  • 이종렬;이웅종;채재홍;박경상;김기수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.175-180
    • /
    • 1999
  • The heating system of korea apartment house is called Ondol. The surface finishing mortar of this floor system typically used the cement based mortar, where the surface finishing mortar easily appears the crack. To order to crack control, the cement that added expansive additive used to reducing dry-shrinkage. For the surface finishing mortar, the types of shrinkage is known as plastic shrinkage, dry-shrinkage and autogenous This experimental study is to investigate the difference on dry-shrinkage of the cement that added expansive additives and OPC. The test method is varied the ration of water/cement (W/C) and the ratio of sand/cement(S/C). For OPC, The increase of the ratio of S/C is reduced dry-shirnkage but for the cement that added expansive additives, the increase of the ratio of S/C is augmented dry-shrinkage For OPC, The increase of the ratio of W/C is augmented dry-shrinkage but for the cement that added expensive, the increased of the ratio of W/C is reduced dry-shrinkage.

  • PDF

An Experimental Study on Control Performance of Radiant Floor Cooling Using Ondol (온돌을 이용한 바닥복사냉방의 제어성능에 관한 실험적 연구)

  • 김용이;임재한;한여명;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1165-1173
    • /
    • 2001
  • The objectives of this study are to analyze the application of radiant floor cooling and to evaluate the control methods through experiments when the radiant heating system is used for cooling. Through the experiment analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The cooling curve (reset ratio) is found for radiant cooling, which shows tole relation between outside air temperature and supply water temperature. Comparison of cooling methods shows that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF

A Comparative Study of Housing Culture of Korean Immigrants through Analysis of Living Arrangement in Australia and Canada (해외거주 한인의 주공간 사용 및 주생활 분석을 통해 본 주거문화의 비교 고찰 - 호주(Australia)와 캐나다(Canada)를 중심으로 -)

  • Lee, Young-Shim
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.1
    • /
    • pp.47-61
    • /
    • 2008
  • The purpose of this study is to provide information about domestic living of Korean immigrants in Australia and Canada who have the same cultural background for comparative study. For this, usage of domestic space and living style in housing of 52 Korean households in Melbourne of Australia and 32 Korean households in the region of Waterloo of Canada were analyzed. Ethnographic research with questionnaire were used. Results of the research were as follows. 1. Korean immigrants in each countries were living in houses which was built by company of Australia and Canada. 44.2% of Korean immigrants in Australia were using L+D K and 53.1% of Korean immigrants in Canada were using L D K. 2. Laundry was indispensable for Korean immigrants in both countries and they all wanted to use the laundry as a utility room which could dry, ironing and so on. 3. Drain hole on the floor of the bathroom was not indispensable for most Korean immigrants in both countries for hygienic reason. 4. Korean immigrants in both countries were ironing in master bedroom and they all wanted to separate it from there through renovation and extension and so on. 5. Korean immigrants in Canada were more active to use the formal lounge which has been planned as a traditional element of western house. 6. The seating style of Korean immigrants in both countries belong to chair-seating style mostly. But it was clear that they were making Kimchi with floor seating style in both countries. 7. A level of satisfaction about using carpet was not high for Korean immigrants in both countries cause of uneasiness to clean and it was considered to relate to the floor seating style of them. 8. Almost Korean immigrants were took off the shoes inside of the house and they had shoes cabinet beside the entrance or basement usually. 9. The most popular heating system was ducted heating in both countries. The level of satisfaction about this was different for Korean immigrants in Australia and Canada but most desirable heating system was Ondol for them in both countries commonly.

Viscoelastic Properties of MF/PVAc Hybrid Resins as Adhesive for Engineered Flooring by Dynamic Mechanical Thermal Analysis

  • Kim, Sumin;Kim, Hyun-Joong;Yang, Han-Seung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.37-45
    • /
    • 2006
  • The viscoelastic properties of blends of melamine-formaldehyde (MF) resin and poly(vinyl acetate) (PVAc) for engineered flooring used on the Korean traditional ONDOL house floor heating system were investigated by dynamic mechanical thermal analysis (DMTA). Because MF resin is a thermosetting adhesive, the effect of MF rein was shown across all thermal behaviors. The addition of PVAc reduced the curing temperature. The DMTA thermogram of MF resin showed that the storage modulus (E') increased as the temperature was further increased as a result of the cross-linking induced by the curing reaction of the resin. The storage modulus (E') of MF resin increased both as a function of increasing temperature and with increasing heating rate. From isothermal DMTA results, peak $T_{tan{\delta}}$ values, maximum value of loss modulus (E") and the rigidities (${\Delta}E$) of MF/PVAc blends at room temperature as a function of open time, peak $T_{tan{\delta}}$ and maximum loss modulus (E") values were found to increase with blend MF content. Moreover, the rigidities of the 70:30 and 50:50 MF/PVAc blends were higher than those of the other blends, especially of 100% PVAc or MF. We concluded that blends the MF/PVAc blend ratios correlate during the adhesion process.

The Effects of an Insulation of Low Temperature Gas Chimney on the Optimum Chimney Height (저온(低溫)가스 연돌의 보온이 연돌의 최적높이에 미치는 영향)

  • Kim, Y.D.;Min, M.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.177-187
    • /
    • 1990
  • This paper presents that in the Korean Ondol Heating System using hard coal as an usual fuel, what effects an insulation of chimney with the low temperature gas flow has on the optimum chimney height which gives a maximum gas weight flow rate under the general weather data and actual design condition of chimney is compared with the bared chimney and studied. And also, the effects of chimney materials and diameter, dimensionless temperature difference, insulating materials and thickness which have on the optimum chimney height were researched and a good results increasing a maximum gas weight flowrate is obtained by insulating the chimney.

  • PDF

An Experimental Study on the Properties of Hwangtoh Mortar for the Application of Construction Material (건축적 적용을 위한 황토모르터의 물성에 관한 실험적 연구)

  • Lee, Hyun-Chul;Lee, Gun;Go, Seong-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.43-46
    • /
    • 2006
  • The Hwangtoh is one of the traditional construction material used in wall, plastering material, and ondol (Korean underfloor heating system) with stone and wood. It is an important greenness material and it has much advantages such as; high storage of heat, auto-purification, antibiotic ability, and emission of far infrared rays. But, it is not developed and not used in modern construction because of its low strength and properties of dry shrinkage crack. According to the recent researches and studies, it is evaluated for natural pozzolanic material like flyash or pozzolan. It's possibility on construction material is high because it's chemical and mineralogical proportion is like as Metakaolin and Kaolinite. In this point of view, this study aims to analyze the physical properties on Hwangtoh mortar through an experiment with various activation condition of Hwangtoh, which is natural pozzolanic material, for the purpose of increase the using possibility in construction material.

  • PDF

Draft of Flue Gas in a Briquette Combustion (연탄연소가스유로의 통풍력)

  • Youm Dong-Soo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.7 no.4
    • /
    • pp.227-238
    • /
    • 1978
  • Draft of the conbustion gab burning in a briquette gives a great part of driving force to the flue gas in an Korean conventional ondol heating system. The Paper present s how the draft intensity varies for each whole Combustion duration. In this experiment the temperatures of thirty spots In three gas courses of a briquette were measured and the drafts were calculated form those experimental data. The result is that the shorter the combustion duration of a briquette is, the stronger the draft becomes, the intensity of drafts ranging between 0.15mm Aq to 0.26mm Aq.

  • PDF

A Study on the Discourse for the Improvement of Living Conditions and Housing through Modern Women's Magazines (일제강점기 여성지에 나타난 생활개선 담론의 경향 고찰 - 주생활 및 부엌개량의 내용을 중심으로 -)

  • Kim, Young-Bum
    • Journal of the Korean housing association
    • /
    • v.22 no.4
    • /
    • pp.51-61
    • /
    • 2011
  • This study aimed to grasp trends of the discourse for improving living conditions carried out since 1920's, when the sense for mending the irrationality of conventional living emerged in various magazines. Among the movement, women intellectuals played an important roles to discuss reforming daily life and unhealthy, inconvenient houseworks. This study found the ideological background and direction of this discourse, and estimated its important role for housing improvement, analyzing the contents of articles published in representative womens' magazines of the modern times. In the discourse, they thought that it was most important to make houseworks brief and efficient, and concentrated on building rational environment for houseworks. As reforming kitchen system, heating system (Ondol) should be separated from cooking system to improve hygienic and economical condition of houseworks. Reformed kitchen would be equipped with new installations for effectiveness, lightened by sunlight through windows, and finished floor with cement and drainage for sanitation. Also, they suggested new ways of living, planning modern houses with reformed kitchen system, thinking about moving path and distance of housewives. This discourse would be a foundation to the change of kitchen system up to now.

A Characteristic Heating-Energy Expend of Insulation Block System for Korea Type Passive House (한국형 패시브하우스를 위한 단열블럭시스템의 난방에너지소비 특성)

  • Kang, Jae-Sik;Choi, Gyoung-Seok;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.603-607
    • /
    • 2009
  • About a Structure is performance external insulation is fundamantal performance for enrgy-saving. these day, most of residential structures have constructed by internal insulation method structure. The method structure internal insulation have construction and economical efficiency, but on the other hand, be generated heat loss by heat bridge especially, be generated loss heat-energy logical consequence in structure ondol. The external insulation structure method has a mert able to minimum to loss heat about heat-bridge. But the external insulation technique is unsatisfactory statues within the know-how and method of construction and materials compared with developed countries. The recently, the requirement of market related to the external insulation technique is resulted by the energy efficiency system, but it can lead to the lack of alternative technique In study on the korea type passive house building design for insulation block method of wall system has to experimental characteristic heat-energy of practice building. In result field-experimental, the heat-bridge appeared to characteristic spent heat-energy of blow 2L class and have a suffience performance it.

  • PDF