• Title/Summary/Keyword: On-site performance test

Search Result 455, Processing Time 0.036 seconds

A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems (이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰)

  • Park, Jun-Hyun;Kang, Tae-Seok;Kim, Jae-Hwan;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.26-32
    • /
    • 2015
  • Carbon dioxide principally extinguishes fires by smothering, but an acceptable amount of extinguishing agent is needed. To assure the performance of carbon dioxide systems in Korea, computer programs certified by NEMA are being applied in system design. But the design errors can occur because the geometry of a model test facility is not the same as that of the actual fire area. Since the discharge rate tends to vary considerably with the flow pattern in a pipe, an on-site discharge test is necessary to ensure the performance of the system, especially with low pressure carbon dioxide. Technical standards for carbon dioxide systems do not give detailed guidelines for discharge tests at present. Based on comparative analysis of standards and practical tests, this paper suggests a methodology for on-site discharge tests.

A Study on the Application of Quality Management to Fire Door Construction (방화문 시공시 현장품질관리지침 적용에 관한 연구)

  • Choi, Dong-ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.90-91
    • /
    • 2019
  • When the fire door is recently installed in the field, there are frequent cases where the fire door is manufactured with fire door having low quality or different structure compared to the performance that the fire door producer has confirmed in the performance test or the construction specification. Accordingly, on-site quality management and maintenance guideline for fire doors were presented. In this paper, we tried to explain the requirements for the construction of fire doors during the on-site quality management and maintenance guideline for fire doors presented in the study.

  • PDF

Performance Prediction of a Solar Power System with Stirling Engine in Different Test Sites (설치장소에 의한 스털링엔진 태양열 발전시스템의 성능예측)

  • Kazuo Tsuchiya
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.122-128
    • /
    • 2001
  • The simulation analyses of a dish solar power system with stirling engine in this study are applied to system performance prediction if four different test sites; Seoul, Pusan and Cheju in Korea, and Naha in Japan. The effects of difference of concentrator type such as monolithic and stretched-membrane construction on system efficiency are also evaluated. The total amount of generated power for a year depends on the site. However the total maximum system efficiency in every site is approximately 16% and there isnt striking difference. It is also found that the maximum collector efficiency of stretched-membrane concentrator is about 3∼15% lower than that of the monolithic type.

  • PDF

A Study on the Method of Analyzing the Topography Characteristics of the Main Maneuvering Test Site for the Selection of the Representative Drive Course of Combat Vehicles (전투차량 대표주행경로 선정을 위한 주행시험장 지형 특성 분석 기법 연구)

  • Kim, Juhee;Choi, Hyunho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.293-301
    • /
    • 2021
  • LTV(Light Tactical Vehicle) operating in our military requires higher levels of performance and durability to withstand harsher conditions than general vehicles, as they must travel on both rough-train and off-road as well as on public roads. Recently, LTV development is demanded a variety of test evaluations in order to satisfy ROC (Required Operational Capability) by the military requirement. However, there is no informations of driving test course for satisfying the durability performance of Korean tactical vehicle. Therefore, this study aims to provide basic data to establish reliable drive test conditions by analyzing the main maneuvering test site at the domestic and foreign country in order to select the representative drive course. These studies will provide a more scientific and systematic evaluation solution for the development of tactical vehicles, and can be effectively used to establish a certified system for military vehicle test evaluation in the future

A Study on the Construction of a TestBed for Performance Inspection of Underground Surveying Equipment (지하공간탐사기기 성능검사 테스트베드 구축 연구)

  • Bae, Kyoung Ho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.525-531
    • /
    • 2021
  • The importance and utilization of underground spatial is increasing due to urban concentration. And so underground spatial information is being built. Because underground spatial information is an important NSDI (National Spatial Data Infrastructure), the accuracy and performance of underground spatial exploration devices used for construction are managed separately. In accordance with the laws and regulations related to spatial information, the government is conducting performance tests for underground facilities surveying equipment. The current performance test site mainly targets metal pipelines, and there is no absolute position surveying inspection system. In this study, test bed model for performance inspection of underground space exploration equipment was presented. The test bed presented in this study can be used as a test site to supplement the limitations of the existing domestic test bed and to verify the performance of the latest equipment.

A Study on Performance of Double-Core PBD for Improving Thick Reclaimed Ground (대심도 연약지반 개량을 위한 이중코어 PBD 성능연구)

  • Yang, Jeong-Hun;Hong, Sung-Jin;Lee, Woo-Jin;Choi, Hang-Seok;Kim, Hyung-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.281-292
    • /
    • 2008
  • Prefabricated Board Drains (PBDs) recently become more widely used than conventional sand drains in improving soft ground because the PBD is more time and cost effective. The performance of PBDs is affected by disturbance in the adjacent soil formation during inserting mandrels, the intrusion of fine particles into filter fabric, and necking of the drain by excessive lateral pressure especially occurring in very deep clay formation such as the Busan New Port site. In this study, the PBD with double-core is introduced, which seems to overcome the shortcomings of usual single-core PBDs. An in-situ test program was established in the Busan New Port site, in which a set of the double-core PBDs and the single-core PBDs was installed to compare the efficiency of each of the drains. The discharge capacity of the double-core and the single-core PBDs was compared for various confining pressures in the modified Delft test and the chamber test. A series of CRS consolidation tests was performed in order to obtain profiles of void ratio-effective stress and void ratio-permeability relationships in the Busan New Port site that are used as input date in performing a numerical program ILLICON. The numerically simulated settlements of ground surface in the test site are in good agreement with those of in-situ measurements. In addition, the performance of the double-core and single-core PBDs has been experimentally and numerically compared in this paper.

  • PDF

CDMA Mobile System Testbed and Field Test

  • Kwon, Dong-Seung;Hahm, Young-Kwon;Jeong, In-Myoung;Im, Duck-Bin
    • ETRI Journal
    • /
    • v.19 no.3
    • /
    • pp.259-280
    • /
    • 1997
  • This paper briefly explains the configuration of CDMA Mobile System (CMS) test bed. The measured fading and delay results of CDMA signal in Taejon area are shown. In comparison to other cellular systems, there are more parameters in the CDMA systems that affect system performance and capacity. We performed the optimization test of the selected parameters and present the effect of each parameter on the performance. This paper presents the capacity and performance test results of CMS. The capacity test was performed on ETRI site of three sectors in Taejon area. The performance tests include call completion rate, busy hour call attempt, and the delay characteristics of voice.

  • PDF

A Study on the Safety of Reuse Work Plate by Performance Test (재사용 작업대 성능시험을 통한 안전성 검토)

  • Choi, Jin-Woo;Choi, Don-Hoeng;Go, Seong-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.43-46
    • /
    • 2011
  • The work plate in a construction sites is a frequent cause of falling. But the bulk of the work plates lent to the construction site are handled carelessly by workers. There is general concern about performance declining by repetitive use. However, there is not a accurate guide, research and study on reuse work plate. This study was conducted in order to judge the classification guide to reuse work plate and measure the performance of classified reuse work plates. It is the result that even the A-grade plates classified to be in good shape by workers are below the performance standard. This means that the guide and classification are ineffective.

Performance Monitoring and Load Analysis of Wind Turbine (풍력발전기의 성능 모니터링 및 하중분석)

  • Bae, Jae-Sung;Kim, Sung-One;Youn, Joung-Eun;Kyung, Nam-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.385-389
    • /
    • 2004
  • Test facilities for the wind turbine performance monitoring and mechanical load measurements are installed in Vestas 100 kW wind turbine in Wollyong test site, Jeju island. The monitoring system consists of Garrad-Hassan T-MON system, telemetry system for blade load measurement, various sensors such as anemometer, wind vane, strain gauge, power meter, and etc. The experimental procedure for the measurement of wind turbine loads, such as edgewise(lead-lag) bending moment, flapwise bending moment, and tower base bending moment, has been established. Strain gauges are on-site calibrated against load cell prior to monitoring the wind turbine loads. Using the established monitoring system, the wind turbine is remotely monitored. From the measured load data, the load analysis has been performed to obtain the load power spectral density and the fatigue load spectra of the wind turbine.

  • PDF

A Study on Development of Test Site for Wind Turbine Prototype Test (풍력터빈시험을 위한 실증시험장 개발에 관한 연구)

  • Moon, Chae-Joo;Chang, Young-Hag;So, Soon-Yeol;Kim, Tae-Gon;Kim, Young-Gon;Jeong, Moon-Seon;Jeong, Seong-Won
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.101-107
    • /
    • 2013
  • It is evident that in the wind energy business as an economic activity there is a close relationship between the wind speed and the revenues. The wind turbine test facility for wind turbine accreditation is intended to be used by the industry for testing of both main components and systems. This paper suggest the wind test site for certification of prototype wind turbine with international regulations. The test site has an environmental permit for wind turbines with a maximum hub height of 120m and a rotor diameter up to 120m, and can accommodate prototypes with installed electrical powers up to 5MW each. A wind turbine manufacturer can lease the location for a period of type certification. And also researchers are the development of new methods for measuring the influence, performance and durability of the components, a mathematical and numerical modelling of component responses by using the site.