• Title/Summary/Keyword: On-line monitor

Search Result 384, Processing Time 0.029 seconds

A Study on the Model of A Electric Railway Substation Automation Based on IEC 61850 and IEC 61970 (IEC 61850과 IEC 61970을 표준으로 하는 전철변전소 종합자동화 모델에 관한 연구)

  • Ko, Chung-Ku;Jang, Woo-Jin;Choi, Kyu-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1014-1019
    • /
    • 2011
  • The substation automation is a system to remote-monitor and control electric power flow. And in line with electrification of railway, an interest in electric railway substation automation is increasing. IEC standardized IEC 61850, IEC 61968 and IEC 61970 communication protocol for the telecommunication standardization of the electric power automation industry. The recent SCADA systems in managed electric railway substations are have the problem about the compatibility with the products which fit to the international standard specification afterward. In this paper, the model of electric railway substation automation based on IEC 61850 and IEC 61970 is presented. And the method supporting the compatibility between the equipment is proposed.

  • PDF

A Study on the Fluid Flew with Ultrasonic Forcing by PIV Measurement (초음파가 가진된 유체유동의 PIV계측에 의한 연구)

  • 주은선;이영호;나우정;정진도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1281-1290
    • /
    • 2001
  • A study on the fluid flow with ultrasonic forcing is carried out to obtain data for the turbulence enhancement. A large water tank is made of the transparent acrylic plates and a horizontal flow field is given by setting two acrylic tubes to face mutually on a horizontal line. A 2-dimensional PlV system which is composed of a continuous-output 4W Argon-ion laser, a high-speed video camera, a PC based by an image grabber and a high resolution monitor is used to investigate characteristics of the complex turbulence flow field. And a 2MHz ultrasonic transducer is used fur ultrasonic vibration forcing. Some experiments are carried out at Reynolds numbers of 2,000 and 4,000 and at 7 angles of ultrasonic incidence. In results, the flew velocity vector distribution, kinetic energy and turbulence intensity in both cases of with and without ultrasonic forcing are examined, compared and discussed by using PIV measurement. It is clarified that the ultrasonic forcing into flow field is valid to obtain the turbulence enhancement.

  • PDF

Navigation Control for a Mobile Robot using a Camera (카메라를 이용한 이동 로봇 주행 제어)

  • Moon, Soon-Hwan;Han, Min-Hong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.22 no.2
    • /
    • pp.165-177
    • /
    • 1996
  • This paper presents a navigation method for a mobile robot which can follow a path drawn on a monitor screen. The current position and heading direction of the mobile robot are obtained using a single camera from a single image of the guide mark projected on a convex mirror. This proposed method eliminates the need to rotate or tilt the camera to track the guide mark, because the convex mirror and a stationary camera provide a panoramic view of the surrounding area. As guide marks, fluorescent lamps on the ceiling, door frames, or any other natural line segment can be used without adding any artificial elements to them.

  • PDF

A study about Embodying an AMR Based on Power Line Communication.

  • Yoon, Gun;Park, Hong-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.119.2-119
    • /
    • 2001
  • The inspection of a meter is an action that measures the amount of electricity, water and gas used to impose user on a charge. In past days, a meter who visit consumer to look over meter and write data to the ledger and then go back his office to calculates the inspection of a meter. On the other hand, the AMR(Automatic Meter Reading) is remote control system to measure the amount of utility used and monitor a condition of the meter. A study about AMRS is started at 1960 all over the world and a successful application example is presented continuously in American, Europe and Japan etc. In this paper we use a check meter that is used in past days and we add an AMR to it. AMR receives data that is the amounts of electricity from the check meter and stores those ...

  • PDF

Cerebellar Control of Saccades (소뇌의 단속안구운동 조절)

  • Choi, Jae-Hwan;Choi, Kwang-Dong
    • Annals of Clinical Neurophysiology
    • /
    • v.15 no.2
    • /
    • pp.37-41
    • /
    • 2013
  • Saccades are rapid eye movements that shift the line of sight between successive points of fixation. The cerebellum calibrates saccadic amplitude (dorsal vermis and fastigial nucleus) and the saccadic pulse-step match (flocculus) for optimal visuo-ocular motor behavior. Based on electrophysiology and the pharmacological inactivation studies, early activity in one fastigial nucleus could be important for accelerating the eyes at the beginning of a saccade, and the later activity in the other fastigial nucleus could be critical for stopping the eye on target, which is controlled by inhibitory projection from the dorsal vermis. The cerebellum could monitor a corollary discharge of the saccadic command and terminate the eye movement when it is calculated to be on target. The fastigial nucleus and dorsal vermis also participate in the adaptive control of saccadic accuracy.

Application of Landsat images to Snow Cover Changes by Volcanic Activities at Mt. Villarrica and Mt. Llaima, Chile

  • Kim, Jeong-Cheol;Kim, Dae-Hyun;Park, Sung-Hwan;Jung, Hyung-Sup;Shin, Han-Sup
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.3
    • /
    • pp.341-350
    • /
    • 2014
  • Landsat images can monitor the snow-covered Earth surface variations with the ground resolution of 30m and the multi-spectral bands in the visible, NIR, SWIR and TIR spectral regions for the last 30 years. The Southern Volcanic Zone (SVZ) of Chile consists of many volcanoes, and all of the volcanoes are covered with snow at the top of mountain. Snow cover area in southern province of the SVZ of Chile (37 to $46^{\circ}S$) have been influenced by significant frontal retreats as well as eruptive activities. In this study, we have investigated the changes of the snow-cover area and snow-line elevation at Mt. Villarrica and Mt. Llaima, Chile from three Landsat images acquired on Feb. 1990, 2005 and 2011. The snow-cover areas are 13.42, 26.75 and $21.60km^2$ at Mt. Villarrica in 1990, 2005 and 2011, respectively, and 3.82, 25.12 and $8.89km^2$ at Mt. Llaima in 1990, 2005 and 2011, respectively. The snow-line elevations are 1871, 1738 and 1826m at Mt. Villarrica in 1990, 2005 and 2011, respectively, and 2007, 1822 and 1818m at Mt. Llaima in 1990, 2005 and 2011, respectively. The results indicate that both of the snow-cover and snow-line changes are strongly related with the volcanic activity change. The results demonstrate that the snow-cover area and snow-line elevation changes can be used as an indicator of the volcanic activity at Mt. Villarrica and Mt. Llaima, Chile.

Measurement of Particles Generated from PECVD Process using ISPM (ISPM을 이용한 PECVD 공정 내 발생입자 측정 연구)

  • Kim, Dongbin;Mun, Jihun;Kim, HyeongU;Kang, Byung Soo;Yun, JuYoung;Kang, SangWoo;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.11 no.4
    • /
    • pp.93-98
    • /
    • 2015
  • Particles which generated from plasma enhanced chemical vapor deposition (PECVD) during thin film deposition process can affect to the process yield. By using light extinction method, ISPM can measure particles in the large-diameter pipe (${\leq}300mm$). In our research, in-situ particle monitor (ISPM) sensor was installed at the 300 mm diameter exhaust-line to count the particles in each size. In-house flange for mounting the transmitting and receiving parts of ISPM was carefully designed and installed at a certain point of exhaust line where no plasma light affect to the light extinction measurement. Measurement results of trend changes on particle count in each size can confirm that ISPM is suitable for real-time monitoring of vacuum process.

A Study on the Application of Under Voltage Load Shedding Scheme in Line Contingency considering Motor Load (모터부하를 고려한 상정사고 발생 시 저전압 부하차단 적용 방안에 대한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.21-26
    • /
    • 2017
  • Failure of high-voltage transmission line, which is responsible for large-scale power transmission, can be reason for system voltage instability. There are many methods to prevent voltage instability like adjustment of equipment, the generator voltage setting, and load shedding. Among them, the load shedding, have a problem of economic loss and cascading effect to power system. Therefore, the execution of load shedding, amount and timing is very important. Conventionally, the load shedding setting is decided by the preformed simulation. Now, it is possible to monitor the power system in real time by the appearance of PMU(Phasor Measurement Unit). By this reason, some of research is performed about decentralized load shedding. The characteristics of the load can impact to amount and timing of decentralized load shedding. Especially, it is necessary to consider the influence of the induction motor loads. This paper review recent topic about under voltage load shedding and compare with decentralized load shedding scheme with conventional load shedding scheme. And simulations show the effectiveness of proposed method in resolving the delayed voltage recovery in the Korean Power System.

Design and characterization of a Muon tomography system for spent nuclear fuel monitoring

  • Park, Chanwoo;Baek, Min Kyu;Kang, In-soo;Lee, Seongyeon;Chung, Heejun;Chung, Yong Hyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.601-607
    • /
    • 2022
  • In recent years, monitoring of spent nuclear fuel inside dry cask storage has become an important area of national security. Muon tomography is a useful method for monitoring spent nuclear fuel because it uses high energy muons that penetrate deep into the target material and provides a 3-D structure of the inner materials. We designed a muon tomography system consisting of four 2-D position sensitive detector and characterized and optimized the system parameters. Each detector, measuring 200 × 200 cm2, consists of a plastic scintillator, wavelength shifting (WLS) fibers and, SiPMs. The reconstructed image is obtained by extracting the intersection of the incoming and outgoing muon tracks using a Point-of-Closest-Approach (PoCA) algorithm. The Geant4 simulation was used to evaluate the performance of the muon tomography system and to optimize the design parameters including the pixel size of the muon detector, the field of view (FOV), and the distance between detectors. Based on the optimized design parameters, the spent fuel assemblies were modeled and the line profile was analyzed to conduct a feasibility study. Line profile analysis confirmed that muon tomography system can monitor nuclear spent fuel in dry storage container.

A Study on The Analysis Method of Problem Solving Results of Linear Functions (일차함수의 문제해결 결과 분석 방법에 관한 연구)

  • Jang, Cheong Hee;Han, Ju-Wan
    • Journal of the Korean School Mathematics Society
    • /
    • v.25 no.1
    • /
    • pp.79-104
    • /
    • 2022
  • It is very important to help students learn by examining how well students solve math problems. Therefore, in this study, four methods(error analysis by problem type, schematization analysis, area graph analysis, and broken line graph analysis) were constructed to analyze how the connectivity between concepts of middle school functions affects the problem solving results. The students' learning situation was visually expressed to enable intuitive understanding. This analysis method makes it easy to understand the evaluation results of students. It can help students learn by understanding their learning situation. It will be useful in mathematics teaching and learning as it can help students to monitor their own problems and make a self-directed learning plan.