• 제목/요약/키워드: On-line measurement

검색결과 1,876건 처리시간 0.025초

Modified Transmission Line Protection Scheme in the Presence of SCC

  • Naeini, Ehsan Mostaghimi;Vaseghi, Behrouz;Mahdavian, Mehdi
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.533-540
    • /
    • 2017
  • Distance relay identifies the type and location of fault by measuring the transmission line impedance. However any other factors that cause miss calculating the measured impedance, makes the relay detect the fault in incorrect location or do not detect the fault at all. One of the important factors which directly changes the measured impedance by the relay is series capacitive compensation (SCC). Another factor that changes the calculated impedance by distance relay is fault resistance. This paper provides a method based on the combination of distance and differential protection. At first, faulty transmission line is detected according to the current data of buses. After that the fault location is calculated using the proposed algorithm on the transmission line. This algorithm is based on active power calculation of the buses. Fault resistance is calculated from the active powers and its effect will be deducted from calculated impedance by the algorithm. This method measures the voltage across SCC by phasor measurement units (PMUs) and transmits them to the relay location via communication channels. The transmitted signals are utilized to modify the voltage signal which is measured by the relay. Different operating modes of SCC and as well as different faults such as phase-to-phase and phase-to-ground faults are examined by simulations.

BCB를 이용한 High & Low$Z_0$전송선로 제작에 대한 연구 (Studies on the fabrication of transmission line with high and low $Z_0$ using BCB layer)

  • 한효종;이성대;전영훈;윤관기;김삼동;황인석;이진구;류기현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(2)
    • /
    • pp.57-60
    • /
    • 2002
  • In this paper, transmission lines with low and high characteristic impedance (Z$_{0}$) are fabricated and analyzed. The transmission lines are fabricated on the benzo-cyclo-butene (BCB) films of a low dielectric constant. For the low Z$_{0}$, two types of coplanar waveguide (CPW) structures are fabricated, which include bottom-ground and double-ground type. Measurement shows that Z$_{0}$ values for each CPW type are 7.3 and 9.4$\Omega$, respectively, at a signal line width of 100 #m. Whit the ratio between the spacing of bottom-ground and the signal line with becomes greater than 2.5, the Z$_{0}$ is nearly saturated. In addition, thin film microstrip lines fabricated using the BCB insertion layers show very low Z$_{0}$ of 25.5$\Omega$, and this impedance is ~64 % of the values obtained from the BCB-based CPW structures of the same line width. Measurement result of CPW on BCB layer is 100.5 Ω.s 100.5 Ω.

  • PDF

전기철도 부하모델링을 위한 신형 전기기관차 측정 및 결과분석 (Measurement and Analysis for Electric Locomotive Modeling)

  • 김주락;한문섭;장동욱;이기원;심건보;김정훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.403-408
    • /
    • 2003
  • This paper presents measurement to develop load model for electric locomotive. Load model is defined as polynomial form and each coefficient is solved by the least square method. Therefore, many data is required for using this method. The measurement is performed on KNR line, from Chongryangri to Donghae. The subject of measurement is voltage, current, active power, reactive power an frequency for EL8100.

  • PDF

개별 전로 전력 계측을 위한 디지털 신호처리 프로세서 기반 전력 관제 시스템의 제작 및 평가 (Fabrication and Evaluation of Digital Signal Processor for Multi-Lane Energy Measurement System)

  • 김근준;강봉순
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.619-623
    • /
    • 2018
  • 사회의 발달로 인하여 전력에 대한 수요가 증가함과 동시에 전력의 품질 관리가 중요한 문제로 부상하였다. 이러한 전력관리를 효율적으로 수행하기 위하여 본 논문에서는 다선로 전력 계측을 위한 DSP 기반 전력 측정 시스템을 제안한다. 종래의 전력 계측 시스템이 하나의 선로의 전력만을 측정 할 수 있었기 때문에, 개별 선로에 대한 전력 품질 측정을 위해서는 선로마다 전력 품질 측정 장치가 필요로 하였으며 이는 비용적인 문제로 인하여 시스템의 실제 구현이 불가능한 구조였다. 본 논문에서 제안하는 시스템은 디지털 신호 처리 알고리즘을 이용하여 최대 12개소의 전력 품질을 실시간 계측 할 수 있는 시스템을 제안하며, 이를 토대로 한 시제품을 한국전기연구원의 공인시험 성적서를 통하여 그 성능을 평가 받았다. 성능 시험결과 정밀 계측의 오차 범위 ${\pm}0.3%$의 우수한 성능임을 평가 받았다.

On-line streaming potential 측정에 의한 in-line 약품응집/정밀여과 공정의 최적화 (Optimization of In-line Coagulation/MF Process Using On-line Streaming Potential Measurement)

  • 오정익;이석헌
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.522-528
    • /
    • 2004
  • Microfiltration with in-line rapid coagulation for drinking water production was examined. The in-line rapid coagulation was conducted using newly developed mixing device instantaneous flash mixer. The flux decline during membrane filtration was monitored with coagulant dosage varied. Flux decline was minimized at 1.1mg/L of coagulant dosage, where streaming potential of coagulated water was near zero. The optimum dosage for the process control was explained by dimensionless distance (${\kappa}{\times}a$) of particle pairs, obtained from electrophoresis parameter describing electrostatic repulsion relative to Van der Waals energy between particle pairs in the pre-coagulated water.

다중경로 분석을 위한 전력선 네트워크 기술 방법에 관한 연구 (A Study of Power Line Network Description Method for Multi path Analysis)

  • 오휘명;최성수;이원태;김관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.2986-2988
    • /
    • 2005
  • To improve the reliability of power-line communication systems, the measurement and analysis has been proceeded in many power-line channel environments. In spite of the wired channel, power line channel has many multi-paths that are changing with load-variation, line-interconnection, impedance mismatching and so on. We accordingly need an analysis method based on the multi-path channel impulse response. Recently, a method to describe the homogeneous Power-line network has been published[1]. In this paper the modified method that can describe both the homogeneous and non -homogeneous power-line network has presented.

  • PDF

Research on the Correlation of Control Malfunction with Induced Voltage of Control Signal Line According to Voltage Change of a Power Line

  • Kang, Dong-Woo;Kim, In-Gun;Ham, Sang-Hwan;Kim, Sung-Yul;Bae, Sungwoo;Kim, Dae-Nyeon;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.775-780
    • /
    • 2016
  • This induced voltage measurement test and electromagnetic field simulation are related to the possibility of control signal malfunction by power line. Through an experiment, this research analyzed whether the voltage causing control malfunction according to the on/off status of power permitted to power line was induced to control signal line. Also, the research calculated the voltage induced to control signal line and examined the phenomenon by conducting an electro-magnetic field-specific simulation through the finite element method for the cable model used in the experiment.

20대 여성의 Tight-fit원형설계에 관한 연구 (A Study of Tight-fit Bodice Pattern for 20's Women)

  • 정복희;나미향
    • 대한가정학회지
    • /
    • 제39권8호
    • /
    • pp.137-154
    • /
    • 2001
  • This study was made to draft the tight fitting bodice pattern which horizontal and perpendicular stands are to be lightly set, with the consideration of characteristics of body shape in design of clothes. Measurement of body was conducted on 53 women in twenties, and observation was made on surface development pattern by adhesive tape addition method and gypsum method on three standard objects. In the study, bodice pattern was completed by using already made Somato- measurer, compared with existing bodice pattern, and the results are as follows. The result of the correlation analysis by body measurement shows that chest circumference has a relation to B$.$P-front neck point, side neck point, shoulder point, front interscye breadth point, and the item in spine scapulae point has relation to the item of back neck line, and front & back horizontal values. The degree of shoulder slant, width of armhole and of its depth, the amount of breast, back space, back length were shown to be directly measured from the body. In surface development pattern, tight-fit bodice pattern necessary to the breast volume and back space were shown to be investigated and these volume have to be given in setting up basic line for clothes design together with body measurement value. The result of sensory evaluation for appearance test on fitness shows higher value of research bodice including line of shoulder line, front and back interscye breadth, chest circumference, waist circumference, armhole circumference and of its depth, compared with the research bodice in most items. The result of this study is seen showing high effectiveness for the basic data to design the ready-made dress of high sensitivity of high value added tat.

  • PDF

A Study of 100 tonf Tensile Load for SMART Mooring Line Monitoring System Considering Polymer Fiber Creep Characteristics

  • Chung, Joseph Chul;Lee, Michael Myung-Sub;Kang, Sung Ho
    • 한국해양공학회지
    • /
    • 제35권4호
    • /
    • pp.266-272
    • /
    • 2021
  • Mooring systems are among the most important elements employed to control the motion of floating offshore structures on the sea. Considering the use of polymer material, a new method is proposed to address the creep characteristics rather than the method of using a tension load cell for measuring the tension of the mooring line. This study uses a synthetic mooring rope made from a polymer material, which usually consists of three parts: center, eye, and splice, and which makes a joint for two successive ropes. We integrate the optical sensor into the synthetic mooring ropes to measure the rope tension. The different structure of the mooring line in the longitudinal direction can be used to measure the loads with the entire mooring configuration in series, which can be defined as SMART (Smart Mooring and Riser Truncation) mooring. To determine the characteristics of the basic SMART mooring, a SMART mooring with a diameter of 3 mm made of three different polymer materials is observed to change the wavelength that responds as the length changes. By performing the longitudinal tension experiment using three different SMART moorings, it was confirmed that there were linear wavelength changes in the response characteristics of the 3-mm-diameter SMART moorings. A 54-mm-diameter SMART mooring is produced to measure the response of longitudinal tension on the center, eye, and splice of the mooring, and a longitudinal tension of 100 t in step-by-step applied for the Maintained Test and Fatigue Cycle Test is conducted. By performing a longitudinal tension experiment, wavelength changes were detected in the center, eye, and splice position of the SMART moorings. The results obtained from each part of the installed sensors indicated a different strain measurement depending on the position of the SMART moorings. The variation of the strain measurement with the position was more than twice the result of the difference measurement, while the applied external load increased step-by-step. It appears that there is a correlation with an externally generated longitudinal tensional force depending on the cross-sectional area of each part of the SMART mooring.