A completely non-contact recognition system for bridge unit influence line using portable cameras and computer vision

  • Dong, Chuan-Zhi;Bas, Selcuk;Catbas, F. Necati
    • Smart Structures and Systems
    • /
    • v.24 no.5
    • /
    • pp.617-630
    • /
    • 2019
  • Currently most of the vision-based structural identification research focus either on structural input (vehicle location) estimation or on structural output (structural displacement and strain responses) estimation. The structural condition assessment at global level just with the vision-based structural output cannot give a normalized response irrespective of the type and/or load configurations of the vehicles. Combining the vision-based structural input and the structural output from non-contact sensors overcomes the disadvantage given above, while reducing cost, time, labor force including cable wiring work. In conventional traffic monitoring, sometimes traffic closure is essential for bridge structures, which may cause other severe problems such as traffic jams and accidents. In this study, a completely non-contact structural identification system is proposed, and the system mainly targets the identification of bridge unit influence line (UIL) under operational traffic. Both the structural input (vehicle location information) and output (displacement responses) are obtained by only using cameras and computer vision techniques. Multiple cameras are synchronized by audio signal pattern recognition. The proposed system is verified with a laboratory experiment on a scaled bridge model under a small moving truck load and a field application on a footbridge on campus under a moving golf cart load. The UILs are successfully identified in both bridge cases. The pedestrian loads are also estimated with the extracted UIL and the predicted weights of pedestrians are observed to be in acceptable ranges.

A Study on the Monitoring System of Passive Filter to Improve Power Quality (전력품질 개선을 위한 수동필터 모니터 시스템에 관한 연구)

  • Yu, Jae-Geun;Lee, Sang-Ik;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.89-91
    • /
    • 2007
  • In this paper, we developed DSP based control system to automatically open and close passive filter, which is used to reduce harmonics, according to operating condition of loads. Passive filter control system automatically open and close each branch of filter according to working conditions of loads by sending signals to open and close installation of passive filter after measuring and monitoring voltage, current, harmonics, reactive power, power factor and so on. We verified it's performance by connecting control system with passive filter in the power line using the 100[HP] d.c. motor drive, opening and closing passive filter according to operation condition of motor, and measuring harmonics and reactive power, etc.

  • PDF

Feature Extraction of Partial Discharge for Stator Winding of High Voltage Motor (고압전동기 고정자권선의 부분방전 특징추출)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.7 no.4
    • /
    • pp.61-69
    • /
    • 2004
  • On-line monitoring of fault discharge is an important approach for indicating the condition of electrical insulation of stator winding in high voltage motor. In this paper, several key aspects of on-line monitoring system are discussed, involving the characteristics of fault discharge of stator winding in high voltage motor, spectrum analysis of four simulation fault signals, feature extraction of internal fault discharge from apply voltage to breakdown. The study of the partial discharge activities allows to highlight the ageing stage in the winding fault under test. During the life of the winding insulation fault, the shape of PD signal change relating to the ageing stage. The ageing of stator winding insulation fault of high voltage motor is investigated based on the characteristics of partial discharge pulse distribution and statistical parameters, such as maximum, skewness and kurtosis using discrete wavelet trnasform coefficients.

  • PDF

Implementation of a ECG monitoring system and portable pulse oximeter for $SpO_2$ using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대형 산소포화도 측정 및 ECG 감시 시스템의 구현)

  • Kim, Dong-Hak;Kim, Young-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we aims to develop a microcontroll er-based ECG monitoring system and portable pulse oximeter using Compact Flash Interface. First, portable pulse oximeter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of $SpO_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patient's condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO2 modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact falsh interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

Electrical Characteristic Changes of ZnO Varistors by Energy Absorption

  • Kim, Woo-Hyun;Hwang, Seong-Cheol;Wang, Guoming;Kil, Gyung-Suk;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.12
    • /
    • pp.817-821
    • /
    • 2017
  • As a ZnO varistor is subjected to electrical and environmental stresses, it degrades gradually, which may result in power interruption by short circuit. This study investigates changes in the electrical characteristics of ZnO varistors due to deterioration owing to energy absorption, and determines the optimal parameters for on-line diagnosis of the varistor. Two types of varistors were used for an accelerated aging experiment involving the application of the $8/20{\mu}s$ standard lightning impulse current. The electrical characteristics in terms of the reference voltage, total leakage current, resistive leakage current, and third-harmonic component of the total leakage current were measured, and their change rates were analyzed. The results revealed that the total leakage current increased slightly with an increase in the varistor absorbed energy, while the resistive leakage current and the third-harmonic component increased apparently. Therefore, the third-harmonic component of the total leakage current was proposed as the optimal parameter for on-line monitoring of ZnO varistor conditions.

Development and Site Evaluation of the On-line Partial Discharge Measuring System on the 13 kV Class Stator Windings for Hydro Generator (13 kV급 수력발전기 고정자 권선용 On-line 부분방전 측정 시스템 개발 및 현장적용 평가)

  • Sun, Jong-Ho;Hwang, Don-Ha;Yun, Young-Ho;Shin, Byoung-Chol;Oh, Bong-Keun;Kang, Dong-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.189-198
    • /
    • 2006
  • In order to improve the reliability of stator windings for hydro generators, it is necessary to detect the defective point and life assessment of the high voltage windings. Especially the on-line partial discharge (PD) test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting generators, this method has been proven the major testing technology in high voltage rotating machines nowadays. The purpose of this paper is to describe the method of the on-line PD measurement on stator windings for hydro-generator with 13 [kV] class ceramic coupler (CC), on-line PD measuring system, terminal box, and index parameters. Also, the developed PD measuring system and 13 [kV] class CC were installed Daechung-dam generator #2. It was found that this installed sensor and system had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz.

Implementation of condition monitoring system in underground utility tunnels using inductive coupler (유도성 커플러를 이용한 지하공동구의 상태감시시스템)

  • Ju, Woo-Jin;Kim, Hyun-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.8
    • /
    • pp.1597-1603
    • /
    • 2017
  • The incidence of fire in underground utility tunnel is lower than other fires, but the damage caused by fire can cause social loss due to social management paralysis as well as economic loss. Hereupon, this paper presents the results of an empirical test on the construction of the underground utility tunnel condition monitoring system using the leakage coaxial cable installed in the underground utility tunnel. For this reason, a verification test was conducted by connecting a inductive coupler 200 Mbps power line communication modem with insertion loss characteristics of $-6{\pm}2dB$ to the installed the leakage coaxial cable installed in the underground utility tunnel. As a result, We confirmed sending/receiving of IP cameras up to 500 m. Therefore, it is judged that it is possible to construct a condition monitoring system for underground utility tunnel by using the leakage coaxial cables installed in the underground utility tunnels without installing additional communication lines for data transmission.

A New Artificial Immune System Based on the Principle of Antibody Diversity And Antigen Presenting Cell (Antibody Diversity 원리와 Antigen Presenting Cell을 구현한 새로운 인공 면역 시스템)

  • 이상형;김은태;박민용
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.4
    • /
    • pp.51-58
    • /
    • 2004
  • This paper proposes a new artificial immune approach to on-line hardware test which is the most indispensable technique for fault tolerant hardware. A novel algorithm of generating tolerance conditions is suggested based on the principle of the antibody diversity. Tolerance conditions in artificial immune system correspond to the antibody in biological immune system. In addition, antigen presenting cell (APC) is realized by Quine-McCluskey method in this algorithm and tolerance conditions are generated through GA (Genetic Algorithm). The suggested method is applied to the on-line monitoring of a typical FSM (a decade counter) and its effectiveness is demonstrated by the computer simulation.

An Experimental Study on the Wear and Vibrational Characteristics of a Loosely supported proceeding Bearing (헐겁게 지지된 저널베어링의 마모 및 전동특성 실험적 연구)

  • Chang, Rae-Hyuk;Pyun, Sung-Kwan;Yoon, Eui-Sung;Kong, Ho-Sung;Choi, Dong-Hoon
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.53-62
    • /
    • 2002
  • Condition monitoring plays a vital role since it sustains reliable operation of industrial plants and machinery in the pursuit of economic whole life operation. In order to achieve this goal, it is needed to monitor various parameters of mechanical system such as vibration, wear, temperature and etc., and finally to diagnosis the root causes of any possible abnormal machine condition. In this work, a machine failure caused by mechanical looseness was experimentally simulated and on-line measurement of the vibration, wear and temperature were simultaneously measured. For the quantitative analyses of machine wear, several statistical parameters of the wear particle size distribution were obtained through the center moment method of the Weibull distribution function, and they were compared to vibrational characteristics. Results showed that the wear and vibrational characteristics did not reveal a strong correlation each other in a loosely supported proceeding bearing.

  • PDF

Assessment of 23 kV Capacitive Coupler for On-line Partial Discharge Measurements

  • Jeong, J.Y.;Kang, D.S.;Sun, J.H.;Heo, J.C.;Park, C.H.
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.123-130
    • /
    • 2009
  • The partial discharge (PD) measurement is a very effective method to assess the winding insulation condition of high-voltage machines, since most of the insulation failure processes are directly or indirectly caused by PD. On-line PD measurements, which can detect insulation defects of winding in the early stages on rotating machines in operation, have been accepted as the most important technique. The epoxy mica capacitive coupler is currently and extensively used for on-line detection of PD pulses of high-voltage rotating machines. To evaluate the feasibility of developing a capacitive coupler that is easier to manufacture at a lower cost compared to epoxy mica couplers, a 100pF capacitive coupler made of ceramic material is designed, fabricated and tested for on-line PD measurements of 23 kV electrical machines. A series of electrical tests and accelerated aging tests are performed on the ceramic coupler to evaluate the performance requirements, long-term reliability and thermal stability for in field application. The test results show that the newly developed ceramic coupler provides equal and improved performance at a lower cost compared to epoxy mica couplers, and estimated voltage life is anticipated to surpass 100 years.