• 제목/요약/키워드: On-air

검색결과 28,919건 처리시간 0.064초

실험실 규모 Cometabolic Air Sparging 공정 적용 특성 평가 : 토양 내 활성미생물 별 MTBE 분해특성 (Evaluation of the Laboratory-Scale Cometabolic Air Sparging Process : Characterization of Indigeneous Microorganism on MTBE Degradation)

  • 안상우;이시진;장순웅
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2010
  • Cometabolic air sparging (CAS) is a new and innovative technology that uses air sparging principles but attempts to optimize in situ contaminant degradation by adding a growth substrate to saturated zone. CAS relies on the degradation of the primary growth substrate and cometabolic substrate transformation in the saturated zone and in the vadose zone for volatilized contaminants. In this study, we have investigated to determine MTBE degradation pattern and microbial activity variation if using propane as a primary substrate at the condition of considering air injection rate and air injection pattern. Laboratory-scale two-dimentional aquifer physical model studies were used and the experimental results were represented that the optimal conditions were as air injection rate of 1,000 mL/min and pulsed air injection pattern (15 min on/off). Over 1,000 mL/min air injection rate and continuous air injection pattern was no affected to increase DO concentration. On the other hand, Injection of propane and propane-utilizing bacteria degraded MTBE partially. And also, injection of propane- and MTBE-utilizing bacteria effectively degraded MTBE and TBA production was observed.

바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향 (Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space)

  • 정광섭;한화택;홍승재
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF

개별공간의 자외선 살균 시스템 (UV Immune System of Personalized Space)

  • 정기범;최상곤
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.63-70
    • /
    • 2009
  • The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria, mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.

GIS를 이용한 대기질 관리 정보 지원시스템(e-AIR) 구현( I ) (Development of Air Pollution Information System Using GIS (e-AIR))

  • 박기학;오승교
    • 환경위생공학
    • /
    • 제18권2호
    • /
    • pp.42-51
    • /
    • 2003
  • Public awareness of air pollution problem has increased the need for real time air pollution information system about changes in air pollution level. The purpose of this study is to construct e-AIR, a user-friendly air pollution information system for urban air quality using GIS(geographic information system) technology for windows. GIS was ideally suited featuring a geographical characteristics(e.g., road, traffics, buildings) and very effectively used in mapping and symbolization for the distribution of the spatial/periodic pollution status(e.g., pie or column chart, graduated symbols) which can be effectively applied to a information system on the web-site. And a user interface, GUI(graphic user interface) was designed very diversely and simply enabled the users connect with e-AIR and obtain a useful information of air quality. A interpretive technique, air pollution health index(e.g., PSI, AEI) was used also which transforms complex data on measured atmospheric pollutant concentrations into a single number or set of numbers in order to make the data more understandable. Eventually the final-step of this study was to construct e-AIR based on Web GIS could be assessed anywhere if internet is available and offer a very useful information services of the air pollution to the public like a weather news.

인공신경망 기반 공기정화기 설치위치에 따른 공기교환성능 예측 (Prediction of Air Exchange Performance of an Air Purifier by Installation Location using Artificial Neural Network)

  • 김나경;강동희;강현욱
    • 한국가시화정보학회지
    • /
    • 제20권2호
    • /
    • pp.21-27
    • /
    • 2022
  • Air purifiers can be placed where the air cleaning is required, making it easy to manage indoor air quality. The position of the air purifier affects the indoor airflow pattern, resulting in different air cleaning efficiency. Many efforts and strategies have been examined through numerical simulations and experiments to find the proper location of the air purifier, but problems still remain due to the various geometrical indoor spaces and arrangements. Herein, we develop an artificial intelligence model to predict the performance of an air purifier depending on the installation location. To obtain the training data, numerical simulations were performed on the different locations of the air purifiers and airflow patterns. The trained artificial intelligence model predicted the air exchange performance depending on the installation location of the air purifier with a prediction accuracy of 92%.

공동주택에서의 실외 급.배기구 위치에 따른 환기효율 향상 연구 (A study on the Improvement of Ventilation Performance in Apartment House According to the Location of Exterior Air-Vents)

  • 박진철;유형규;차진영
    • 한국태양에너지학회 논문집
    • /
    • 제25권2호
    • /
    • pp.71-79
    • /
    • 2005
  • In this study, the ventilation performance of mechanical ventilation system in apartment House was analyzed through model test according to characteristics of air-vent. Then adequate interval of air-vent was suggested using computer simulation which will create comfort environment through improvement of ventilation performance in apartment house. The result of experiment with separation plate to prevent mixture of contaminated exhaust air with fresh supply air, the ventilation efficiency improved about 10%. The result of simulation with horizontal location of exterior air-vent, contaminated exhaust air is mixed regardless of interval variation. Consequently, mixture of the exhaust air can be prevented through locating the supply air vent on the top side and exhaust air vent on the lower side.

고속도로 요금소 주변의 대기오염 현황에 관한 연구 (A study on the condition of air pollution near tollbooths on highway)

  • 김신도;박성규;봉춘근;김종호;강혜진;이의상
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.359-368
    • /
    • 1999
  • The outdoor and indoor air quality surrounding highway have been measured, and the study on the design of the booth shape and the air-conditioning system also has been carried out. For the first step of the work, the air quality at the Seoul tollgate on the Kyeong-bu highway was monitored over a year. The measured indoor air quality shows seasonal average concentration 85.6-92.1ppb of >;$NO_2$and the $SO_2$and CO lower than the EAQS(Environmental Air Quality Standards). The measured TSP concentration was much higher than the EAQS. In conclusion, there is necessity to improve the working environment of the tollbooths on highways, and the current air-conditions need to be modify for the purpose. In the process of modifying the air-conditioning system, particulate pollutants needs to be considered processing and the priority needs to be put on the booths for big vehicles.

  • PDF

고효율 항균 필터의 항균력 평가에 관한 연구 (A Study on Antibacterial Assesment of High Efficiency Antibacterial Air Filter)

  • 권혁구;정진도;류해열;정우성;박덕신
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 춘계학술대회 논문집
    • /
    • pp.549-554
    • /
    • 2002
  • Recently, interest in hygiene has been arouse in the health care field. Consequently, Filters with antibacterial agent applied to improve air quality by sterilizing bacteria, fungi, etc. We actually installed antibacterial air filter containing 2.5wt%Ag zeolite on the air intake route to air-conditioner in passenger cu, and evaluated filter's performance on antibacterial effect. By the microbe liquid spattering method, we found that the antibacterial air filter has notably sufficient antibacterial efficiency against standard strains and wild type strains. Antibacterial effect was observed at whole area of filter media by zone of inhibition test. The evaluation of microbe quantity was conducted through mixing dilution plate culture method. In comparison with ordinary filter, the amount of germs attached on antibacterial air filters was larger. The amount of germs attached on ordinary filters was very small since ordinary filters contained less dust. In comparison in antibacterial air filter with thickness, the amount of germs attached on 9mm filter was smaller than that of on 6mm filter. i.e. thicker filter, superior efficiency.

  • PDF

Analysis on the Age of Air and the Air Change Effectiveness of the Personal Environmental Module System in Intelligent Buildings

  • Cho, Dongwoo
    • Architectural research
    • /
    • 제1권1호
    • /
    • pp.47-53
    • /
    • 1999
  • An interesting of desktop air-conditioning system is the Personal Environmental Module(PEM) System. The PEM system allows the occupant to choose the desired temperature, air volume and direction of the discharged air. In this study, the measurements on the age of air and the air change effectiveness, using the tracer gas method, are carried out to analyze the ventilation performance for provision of fresh air near the breathing zone by the PEM. The relations between the PEM for optimal control and other factors related to indoor air quality, and the ventilation for the PEM are examined. Also, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The minimum local age of air was measured in the breathing zone, which is directly supplied with air from the PEM diffusers, and the measured local air change effectiveness of the desktop diffuser in the breathing zone was about 1.13 to 1.23 times greater than that of the ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구 (A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater)

  • 최휘웅;파쿠르 로커만;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.