제어방식에 따른 산업용 수냉각기의 운전 특성 비교 (A Comparison of Operating Characteristics for Industrial Water Cooler with Variation of Control Methods)

  • 백승문
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.99-105
    • /
    • 2014
  • This paper presents a comparison of operating characteristics for industrial water cooler with variation control methods. The performance analysis regarding the characteristics of condensation capacity, evaporation capacity, compressor load, COP of an on-off type cooler, a hot gas-bypass control type cooler and an inverter control type cooler with respect to the system load is reviewed, respectively. The primary results are as following: the variation of required compressor load of an on-off type cooler with respect to load is 5%, that of hot gas-bypass type is 18% and 66% for an inverter control type cooler. As the result shows, an inverter control type yields relatively huge difference of required compressor load compared to other types of control system. In terms of partial load, COP of an inverter control type cooler presents the highest value, and is considered as the optimized type for the used of the system involving frequent partial load.

On-Off 형태의 LQG 알고리즘을 이용한 복합제어 시스템 (Hybrid Control System Using On-Off Type LQG Algorithm)

  • 정형조;윤우현;이인원;박규식
    • 한국전산구조공학회논문집
    • /
    • 제18권3호
    • /
    • pp.227-243
    • /
    • 2005
  • 본 논문에서는 지진하중을 받는 사장교에 납고무받침과 유압식 가력기를 결합한 복합제어 시스템을 적용하였다. 복합제어 시스템은 다중의 제어장치로 인해 제어성능의 향상을 기대할 수 있지만 추가적으로 사용되는 능동제어 장치로 인하여 전체 제어시스템의 강인성이 저하될 수 있다. 따라서 본 연구에서는 복합제어 시스템의 강인성을 향상시키기 위해 기존의 LQG 알고리즘에 납고무받침의 응답에 따른 on-off 형태의 알고리즘을 결합하였다. 수치해석 결과 on-off 형태의 LQG 알고리즘을 사용한 복합제어 시스템은 납고무받침을 사용할 수동제어 시스템이나 유압식 가력기만을 사용한 능동제어 시스템과 비슷한 최대제어력이나 평균제어력을 사용하면서 제어성능이 향상되었으며, 기존의 성능에 초점을 둔 LQG 알고리즘만을 사용한 복합제어 시스템과 유사한 제어성능을 나타냈다. 또한 제안된 제어시스템은 구조물의 강성행렬에 교란이 있을 때 기존의 LQG 알고리즘만을 사용한 복합제어 시스템에 비해 강인성이 향상되었으며 교란된 시스템에 대해 불안정성을 보이지 않았다. 제안된 제어시스템은 설계지진뿐만 아니라 다른 입력지진에 대해서도 제어성능을 유지하였다. 따라서 On-Off 형태의 LQG 알고리즘을 사용한 복합제어 시스템은 불확실성이 많은 지진하중을 받는 사장교에 개선된 제어기법으로 제안될 수 있다.

산업용 냉각기의 온오프 제어와 토출가스 바이패스 제어 특성 비교 (Characteristics of On-off Control and Hot-Gas Bypass Control in an Industrial Cooler)

  • 백승문;문춘근;김은필;정석권;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권4호
    • /
    • pp.429-435
    • /
    • 2011
  • 본 연구는 현재 시판되어 산업현장에서 사용 중인 산업용냉각기의 대표적인 타입인 온오프 제어기가 채용된 냉각기와 토출가스 바이패스 제어기가 채용된 냉각기의 온도 제어 시스템의 운전특성 및 제어 특성을 비교분석하였다. 온오프 제어 냉각기보다 토출가스 바이패스 제어 냉각기는 최소 8%, 최대 20% COP가 높게 나타났다. 이러한 결과들은 산업 현장에서 좀 더 상황에 맞는 제품의선정을 할 수 있는 기초 자료로서 활용될 수 있으리라 생각된다.

Switching Transient Analysis and Design of a Low Inductive Laminated Bus Bar for a T-type Converter

  • Wang, Quandong;Chang, Tianqing;Li, Fangzheng;Su, Kuifeng;Zhang, Lei
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1256-1267
    • /
    • 2016
  • Distributed stray inductance exerts a significant influence on the turn-off voltages of power switching devices. Therefore, the design of low stray inductance bus bars has become an important part of the design of high-power converters. In this study, we first analyze the operational principle and switching transient of a T-type converter. Then, we obtain the commutation circuit, categorize the stray inductance of the circuit, and study the influence of the different types of stray inductance on the turn-off voltages of switching devices. According to the current distribution of the commutation circuit, as well as the conditions for realizing laminated bus bars, we laminate the bus bar of the converter by integrating the practical structure of a capacitor bank and a power module. As a result, the stray inductance of the bus bar is reduced, and the stray inductance in the commutation circuit of the converter is reduced to more than half. Finally, a 10 kVA experimental prototype of a T-type converter is built to verify the effectiveness of the designed laminated bus bar in restraining the turn-off voltage spike of the switching devices in the converter.

유압 전자 파일럿밸브를 이용한 섬유송출기 속도제어에 관한 연구 (A Study on Speed Control of Textiles Let off Using Hydraulic Solenoid Pilot Valve)

  • 이재구;김도태;김성동
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.225-230
    • /
    • 2002
  • Machine of textiles let off is equipment supplying constantly fabrics. Nowdays, as it is replaced band - brake type with hydraulic motor driven type, we looked into characteristic of hydraulic solenoid pilot direction valve(SPDV) for controlling acceleration performance of hydraulic motor. This study deals with controlling the initial speed of textiles let off machine. Finally, to control the initial speed of hydraulic motor, we controlled the adjustment screw of SPDV by a hand. Test which was carried out in the laboratory shows that initial speed of textiles let off could be improved by controlling adjustment screw of SPDV. Also, the results of experiment work were compared with dynamic characteristic of other on/off solenoid direction valve(SDV).

  • PDF

On-off Dewatering Control for Lipase-catalyzed Synthesis of n-Butyl Oleate in n-Hexane by Tubular Type Pervaporation System

  • Kwon, Seok-Joon;Rhee, Joon-Shick
    • Journal of Microbiology and Biotechnology
    • /
    • 제8권2호
    • /
    • pp.165-170
    • /
    • 1998
  • Lipase-catalyzed esterification of n-butyl oleate was carried out in n-hexane as a model reaction. The optimal activity of Candida rugosa lipase was shown in a water activity ($a_w$) range of 0.52 to 0.65 at $30^{\circ}C$. The water produced from the esterification was removed by a tubular type pervaporation system. The rate of ester formed from the enzymatic esterification was allowed to be the same as the rate of water removal by maintaining an optimal $a_w$ of the reaction system using an on-off dewatering control device. The reaction rate and yield with a$a_w$ control were increased two folds higher than the respective values for the uncontrolled reaction.

  • PDF

ON-OFF형 비선형 제어기에 의한 서보 모터의 제어 (Servo Motor Control by On-Off Type Nonlinear Controller)

  • 김영복
    • 동력기계공학회지
    • /
    • 제2권2호
    • /
    • pp.55-59
    • /
    • 1998
  • In practice, the property of nonlinearity is contained in all physical systems. In other word, all physical systems are nonlinear to some degree. Therefore it is important that we acquires a facility for analyzing feedback control systems with varying degrees of nonlinearity. To operate the system linearly over wide range of variation of signal amplitude and frequency, the system requires components of an extremely high quality. Such a system would probably be impractical in the view points of cost, space and weight. In this context of view, it is worth noting that the nonlinearities may be intentionally introduced into a system in order to compensate for the effects of other undesirable nonlinearities or to obtain better performance than what could be achieved using linear element only. A simple example of an intentional nonlinearity is the use of a nonlinear damped system to optimize response in accordance with the magnitude of error. In this paper, an on-off type nonlinear controller is introduced and the applicability and validity of a simple on-off controller are presented by the experimental result.

  • PDF

소형 굴삭기용 브리드 오프 센터형 유압 제어 시스템의 특성 (The Characteristic of the Hydraulic Control System with Bleed-off Center Type of a Compact Excavator)

  • 김준식;이승현;이재원
    • 대한기계학회논문집A
    • /
    • 제32권2호
    • /
    • pp.119-126
    • /
    • 2008
  • In this study, the characteristics of the hydraulic control system with bleed-off center type of a compact excavator were analyzed using developed analysis program. From the parametric analysis, the effects of each factor were revealed. Through the simulation with varying parameters, the system parameter effects on the controllable region and the pump pressure and load pressure variations were studied. The results were compared with the experimental ones. The results and discussions of the present paper could aid in the performance improvement of a hydraulic control system of a compact excavator.

솔레노이드 밸브가 유압위치제어 시스템의 응답특성에 미치는 영향 (Effect of solenoid valves on the response characteristics of a hydraulic position-control system)

  • 장효환;안병홍
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.364-369
    • /
    • 1987
  • It has recently shown that a solenoid valve can be utilized in a hydraulic position-control system by discontinuous control methods. The objective of this study is to investigate the effects of solenoid valves on the response characteristics of a hydraulic position-control system by applying two kinds of discontinued control methods i.e., Simple On-Off (SOF) and Pusating On-Off(POF) controls. Three types of solenoid valves i.e. low-frequency, closed-center type (LF/C), high-frequency, closed-center type (HF/C), low-frequency, tandem-center type(LF/T) were used in this study. Effects of loading conditions and control parameters on the response characteristics were experimentally examined and compared each other. Pressure transients within the actuator were also studied.

  • PDF

고속 온.오프 전자밸브를 사용한 유압실린더 힘 제어계의 응답성 개선 (Response Improvement in Hydraulic Cylinder Force Control System by Using a High Speed On-Off Electro-Magnetic Valve)

  • 이일영;권정호;박정환
    • 유공압시스템학회논문집
    • /
    • 제1권4호
    • /
    • pp.15-21
    • /
    • 2004
  • High speed on-off electro-magnetic valves have been used for pressure control or flow control in automotive or construction machine servomechanisms. These systems require quicker valve switching speed to improve control preciseness. The authors designed and manufactured an electric valve driver with quick response characteristics by using 3 power source type valve driver concept. In experiments by using a hydraulic system incorporating the new valve driver, the new driver shortened the switching lag time from 5 ms to 1.3 ms. And also the new driver showed excellent position tracking control performances.