• Title/Summary/Keyword: On-Off control type

Search Result 270, Processing Time 0.029 seconds

A Comparison of Operating Characteristics for Industrial Water Cooler with Variation of Control Methods (제어방식에 따른 산업용 수냉각기의 운전 특성 비교)

  • Baek, Seung-Moon
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.99-105
    • /
    • 2014
  • This paper presents a comparison of operating characteristics for industrial water cooler with variation control methods. The performance analysis regarding the characteristics of condensation capacity, evaporation capacity, compressor load, COP of an on-off type cooler, a hot gas-bypass control type cooler and an inverter control type cooler with respect to the system load is reviewed, respectively. The primary results are as following: the variation of required compressor load of an on-off type cooler with respect to load is 5%, that of hot gas-bypass type is 18% and 66% for an inverter control type cooler. As the result shows, an inverter control type yields relatively huge difference of required compressor load compared to other types of control system. In terms of partial load, COP of an inverter control type cooler presents the highest value, and is considered as the optimized type for the used of the system involving frequent partial load.

Hybrid Control System Using On-Off Type LQG Algorithm (On-Off 형태의 LQG 알고리즘을 이용한 복합제어 시스템)

  • Jung Hyung-Jo;Yoon Woo-Hyun;Lee In-Won;Park Kyu-Sik
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.3
    • /
    • pp.227-243
    • /
    • 2005
  • This paper presents a hybrid control system combining lead rubber bearings and hydraulic actuators for seismic response control of a cable stayed bridge. Because multiple control devices are operating, a hybrid control system could improve the control performances. However, the overall system robustness may be impacted negatively by additional active control devices. Therefore, a secondary on-off type controller according to the responses of lead rubber bearings is combined with LQG algorithm to improve the controller robustness. Numerical simulation results show that control performances of the hybrid system controlled by an on off type LQG algorithm are improved compared to those of the passive and active control systems and are similar to those of performance oriented hybrid system controlled by a LQG algorithm with the similar peak and normed control forces. Furthermore, it is verified that the hybrid system with an on-off type LQG controller is more robust for stiffness matrix perturbation than conventional hybrid control of system, and there are no signs of instability in the overall system. The proposed control system also maintains the control performance under not only the design earthquakes but also the other earthquakes. Therefore, the hybrid control system using on-off type LQG algorithm could be proposed as an improved control strategy for seismically excited cable-stayed bridges containing many uncertainties.

Characteristics of On-off Control and Hot-Gas Bypass Control in an Industrial Cooler (산업용 냉각기의 온오프 제어와 토출가스 바이패스 제어 특성 비교)

  • Baek, Seung-Moon;Moon, Choon-Geun;Kim, Eun-Pil;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.429-435
    • /
    • 2011
  • In this study the operational characteristics of the temperature control system between an on-offemployed cooler and a bypass type cooler is analyzed. Currently an on-off controller employed coolerwhich is the industry's leading type on the market for industrial coolers is used. The new type cooler isused a bypass controller at discharge gas. The COP of the bypass controlled cooler with discharge gas is at least 8% higher than the on-off controlled cooler. The maximum COP difference is about 20%. Based on the results, the bypass control with discharge gas shows the possible temperature control with high precision.

Switching Transient Analysis and Design of a Low Inductive Laminated Bus Bar for a T-type Converter

  • Wang, Quandong;Chang, Tianqing;Li, Fangzheng;Su, Kuifeng;Zhang, Lei
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1256-1267
    • /
    • 2016
  • Distributed stray inductance exerts a significant influence on the turn-off voltages of power switching devices. Therefore, the design of low stray inductance bus bars has become an important part of the design of high-power converters. In this study, we first analyze the operational principle and switching transient of a T-type converter. Then, we obtain the commutation circuit, categorize the stray inductance of the circuit, and study the influence of the different types of stray inductance on the turn-off voltages of switching devices. According to the current distribution of the commutation circuit, as well as the conditions for realizing laminated bus bars, we laminate the bus bar of the converter by integrating the practical structure of a capacitor bank and a power module. As a result, the stray inductance of the bus bar is reduced, and the stray inductance in the commutation circuit of the converter is reduced to more than half. Finally, a 10 kVA experimental prototype of a T-type converter is built to verify the effectiveness of the designed laminated bus bar in restraining the turn-off voltage spike of the switching devices in the converter.

A Study on Speed Control of Textiles Let off Using Hydraulic Solenoid Pilot Valve (유압 전자 파일럿밸브를 이용한 섬유송출기 속도제어에 관한 연구)

  • 이재구;김도태;김성동
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.225-230
    • /
    • 2002
  • Machine of textiles let off is equipment supplying constantly fabrics. Nowdays, as it is replaced band - brake type with hydraulic motor driven type, we looked into characteristic of hydraulic solenoid pilot direction valve(SPDV) for controlling acceleration performance of hydraulic motor. This study deals with controlling the initial speed of textiles let off machine. Finally, to control the initial speed of hydraulic motor, we controlled the adjustment screw of SPDV by a hand. Test which was carried out in the laboratory shows that initial speed of textiles let off could be improved by controlling adjustment screw of SPDV. Also, the results of experiment work were compared with dynamic characteristic of other on/off solenoid direction valve(SDV).

  • PDF

On-off Dewatering Control for Lipase-catalyzed Synthesis of n-Butyl Oleate in n-Hexane by Tubular Type Pervaporation System

  • Kwon, Seok-Joon;Rhee, Joon-Shick
    • Journal of Microbiology and Biotechnology
    • /
    • v.8 no.2
    • /
    • pp.165-170
    • /
    • 1998
  • Lipase-catalyzed esterification of n-butyl oleate was carried out in n-hexane as a model reaction. The optimal activity of Candida rugosa lipase was shown in a water activity ($a_w$) range of 0.52 to 0.65 at $30^{\circ}C$. The water produced from the esterification was removed by a tubular type pervaporation system. The rate of ester formed from the enzymatic esterification was allowed to be the same as the rate of water removal by maintaining an optimal $a_w$ of the reaction system using an on-off dewatering control device. The reaction rate and yield with a$a_w$ control were increased two folds higher than the respective values for the uncontrolled reaction.

  • PDF

Servo Motor Control by On-Off Type Nonlinear Controller (ON-OFF형 비선형 제어기에 의한 서보 모터의 제어)

  • Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.2 no.2
    • /
    • pp.55-59
    • /
    • 1998
  • In practice, the property of nonlinearity is contained in all physical systems. In other word, all physical systems are nonlinear to some degree. Therefore it is important that we acquires a facility for analyzing feedback control systems with varying degrees of nonlinearity. To operate the system linearly over wide range of variation of signal amplitude and frequency, the system requires components of an extremely high quality. Such a system would probably be impractical in the view points of cost, space and weight. In this context of view, it is worth noting that the nonlinearities may be intentionally introduced into a system in order to compensate for the effects of other undesirable nonlinearities or to obtain better performance than what could be achieved using linear element only. A simple example of an intentional nonlinearity is the use of a nonlinear damped system to optimize response in accordance with the magnitude of error. In this paper, an on-off type nonlinear controller is introduced and the applicability and validity of a simple on-off controller are presented by the experimental result.

  • PDF

The Characteristic of the Hydraulic Control System with Bleed-off Center Type of a Compact Excavator (소형 굴삭기용 브리드 오프 센터형 유압 제어 시스템의 특성)

  • Kim, Jun-Sik;Lee, Seung-Hyun;Lee, Jae-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.2
    • /
    • pp.119-126
    • /
    • 2008
  • In this study, the characteristics of the hydraulic control system with bleed-off center type of a compact excavator were analyzed using developed analysis program. From the parametric analysis, the effects of each factor were revealed. Through the simulation with varying parameters, the system parameter effects on the controllable region and the pump pressure and load pressure variations were studied. The results were compared with the experimental ones. The results and discussions of the present paper could aid in the performance improvement of a hydraulic control system of a compact excavator.

Effect of solenoid valves on the response characteristics of a hydraulic position-control system (솔레노이드 밸브가 유압위치제어 시스템의 응답특성에 미치는 영향)

  • 장효환;안병홍
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.364-369
    • /
    • 1987
  • It has recently shown that a solenoid valve can be utilized in a hydraulic position-control system by discontinuous control methods. The objective of this study is to investigate the effects of solenoid valves on the response characteristics of a hydraulic position-control system by applying two kinds of discontinued control methods i.e., Simple On-Off (SOF) and Pusating On-Off(POF) controls. Three types of solenoid valves i.e. low-frequency, closed-center type (LF/C), high-frequency, closed-center type (HF/C), low-frequency, tandem-center type(LF/T) were used in this study. Effects of loading conditions and control parameters on the response characteristics were experimentally examined and compared each other. Pressure transients within the actuator were also studied.

  • PDF

Response Improvement in Hydraulic Cylinder Force Control System by Using a High Speed On-Off Electro-Magnetic Valve (고속 온.오프 전자밸브를 사용한 유압실린더 힘 제어계의 응답성 개선)

  • Lee I.Y.;Kwon J.H.;Park J.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.1 no.4
    • /
    • pp.15-21
    • /
    • 2004
  • High speed on-off electro-magnetic valves have been used for pressure control or flow control in automotive or construction machine servomechanisms. These systems require quicker valve switching speed to improve control preciseness. The authors designed and manufactured an electric valve driver with quick response characteristics by using 3 power source type valve driver concept. In experiments by using a hydraulic system incorporating the new valve driver, the new driver shortened the switching lag time from 5 ms to 1.3 ms. And also the new driver showed excellent position tracking control performances.

  • PDF