• Title/Summary/Keyword: On-Ground Facilities

Search Result 612, Processing Time 0.028 seconds

Distribution of Antibiotic Resistant Escherichia coli and Water Quality in Waterscape Facilities (물놀이형 수경시설의 수질과 항생제 내성 대장균 분포에 관한 연구)

  • Yoon, Sang-Hoon;Kim, Seon-Gyeong;Kim, Nan-Hee;Wi, Whan;Lee, Se-Hang;Jo, Gwang-Woon;Kim, Dong-Su;Cho, Young-Gwan
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.3
    • /
    • pp.225-233
    • /
    • 2014
  • Objective: This study was performed in order to investigate the distribution of antibiotic resistant E. coli and water quality in waterscape facilities. Methods: Nine waterscape facilities were selected and classified into three types: ground, wall and general fountain. The items analyzed in this study were pH, turbidity, $KMnO_4$ consumption, total colony, total coliforms, fecal coliforms and E. coli. Additionally, an antibiotic resistance test on E. coli was performed. Results: There were no sampling sites that exceeded the permitted limits of water quality, but the concentration of pollutants was high at the beginning operation in June. Moreover, concentration of turbidity, $KMnO_4$ consumption and total colony were higher in ground fountains than in wall and general fountains. Five species of antibiotic resistant E. coli were detected from three sampling sites. Conclusions: The waterscape facilities were significantly contaminated with water microorganisms, especially total colony, total coliforms and fecal coliforms. Disinfection and filtration systems to remove pollutants should be installed for safe waterscape facilities.

Effect of Underground Building for the Groundwater flow in the Ground Excavation (지반굴착에 따른 지반 안정성 평가 시 지하시설물이 지하수흐름에 미치는 영향 분석)

  • Cha, Jang-Hwan;Lee, Jae-Young;Kim, Byung-Chan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.11 no.2
    • /
    • pp.17-28
    • /
    • 2018
  • The purpose of this study is to investigate the effect of underground facilities around excavation zone on groundwater flow characteristics during excavation. The scenarios were constructed considering the size of the underground facility, the separation distance, and the hydraulic gradient. As a result, as the size of the underground facility increases, the difference of head and the hydraulic gradient become large. The shorter the separation distance of underground facility is, the more the difference of head and the hydraulic gradient occur. The effect of hydraulic gradient on model area was relatively small. As a result of analysis of groundwater flow rate for the scenario, groundwater flow rate tends to decrease as the size of underground facility increases or groundwater flow rate tends to decrease as the separation distance decreases. It is necessary to examine the effect of underground facilities on the groundwater flow analysis in the ground excavation.

A Study on the Construction of Waste Incineration Facility by Pyrolysis Type in Iksan City (익산시의 열분해방식 폐기물 소각시설 건설에 관한 연구)

  • 육찬남
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.60-66
    • /
    • 2002
  • Iksan city is planning to construct a waste incinerator on the site of about $110,000\textrm{m}^2$ in size that will be selected from a public bid(Oct.~Nov.2002)in the wake of expiration by June 2003 of use for Hamyeol fill-up ground. Science it has usually been difficult to find sites for filling-up or incinerating facilities owing to NIMBY phenomenon, it is badly requested to employ up-to-date technology for processing wastes without environmental pollution. The conflicts between the administrative authorities and community people with regard to construction of incineration facilities, fill-up ground and facilities for waste processing or recycling are not the matters of just today but are increasingly deepening and spreading countrywide. There seems to be no prospect for these conflicts to be amicably settled through dialogues. They rather become a social disease inflicting the whole country like an epidemic. It is therefore believed to be necessary to introduce measures to design and build environment-friendly facilities that may be accepted by residents as not abominable ones but be used as amusing place while they watch the daily operation of them as watchdogs. Iksan city's plan to construct environment-friendly waste incineration facilities of pyrolysis type without chimney has undergone the process of public hearings and explanatory gatherings from every class of Iksan citizens to get consensus but is still delayed due mainly to be the failure of inducing foreign investments. Pyrolysis technology has two advantages ; first, environment-friendly due to less emission of second pollutants ; second, production of by-products highly valuable as resources. It Is known that Germany has recently begun installation and operation of pyrolysis facility urban wastes, an evidence indicating that pyrolysis method will be widely applied to cope with the tightened regulation to preserve environment worldwide.

A Study on Unmanned Post Office Service Model for the Disabled Person (무인우체국 장애인 서비스 모델 수립에 관한 연구)

  • Choi, Jiyoung;Lee, Jeong-hun;Kim, Jaechul
    • Korean Management Science Review
    • /
    • v.34 no.2
    • /
    • pp.1-14
    • /
    • 2017
  • Recently, despite the presence of a large number of people with disabilities, facilities and services for the disabled are insufficient in comparison with the advanced countries. Especially, unmanned facilities and devices are not available for disabled people without help. As interest in disabled people increased, the convenient facilities for the disabled person should be legally installed in the public places. Moreover, social consensus formation and technical approaches are being actively pursued. In this paper, we propose a five-step scenario to use an unmanned post office. Based on the proposed scenario, we present the method to improve the accessibility of the user interface of the unmanned facilities. And we present a plan for establishing the short- and medium-term service models. This plan is expected to be highly practicable because it reflects the current situations of Korea Post and analysis result of the domestic and oversea cases.

Analysis of the International Safety Criteria of IEEE Std 80 and IEC 479-1 (배전용 접지전극 안전성 분석을 위한 국제기준 검토)

  • Kang, Moon-Ho;Park, Jae-Duck;Lee, Heung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.214-217
    • /
    • 2005
  • To improve the safety of facilities and human beings when the ground fault occurs, public power utility prescribes the reasonable ground resistances, measures and controls the ground resistance of all the ground electrodes biennially. Concerning the safety of human, there are two safety criteria widely accepted, i.e. the IEEE Std 80-2000 and the IEC 479-1:1994. The IEEE Std 80-2000 is based on a simplified electric shock model usually translated into permissible touch and step voltages. The IEC 479-1:1994 is less specific than IEEE Std 80-2000 for analysis purpose. The IEC 479-1:1994 provides values of permissible body current against electric shock duration. This paper provides a technical study of these two standards to analyze the safety of human beings of ground electrodes developed recently for distribution power system.

  • PDF

Measurement of Resistance of Multi-Grounded System by Ground Current Measurement (접지전류 측정에 의한 다중 접지계통의 접지저항 측정)

  • 최종기;안용호;정길조;한병성;김경철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.4
    • /
    • pp.234-237
    • /
    • 2004
  • Measuring ground resistance has been a popular method of evaluation of the grounding electrode performance. If some portions of grounding electrodes are lost by corrosion, aging or other reasons, consequent deteriotation of the grounding performance would be resulted. It is one of the reasons why it is required to evaluate the performance of grounding systems regularly. However, in case of the electric facilities with multi-grounded system such as power substations with multi-grounded overhead ground wires and/or distribution line neutrals, it is practically difficult to disconnect neutrals or skywires from the substation grounding mesh for the ground resistance measurement. In this paper, a method for the grounding performance measurement of multi-grounded systems, which is based on the measuring ground current distributions, has been proposed. A field test results has shown the validity of the proposed test method.

Measurement of Resistance of Multi-Grounded System by Ground Current Measurement (접지전류 측정에 의한 다중 접지계통의 접지저항 측정)

  • 최종기;안용호;정길조;한병성;김경철
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.234-234
    • /
    • 2004
  • Measuring ground resistance has been a popular method of evaluation of the grounding electrode performance. If some portions of grounding electrodes are lost by corrosion, aging or other reasons, consequent deteriotation of the grounding performance would be resulted. It is one of the reasons why it is required to evaluate the performance of grounding systems regularly. However, in case of the electric facilities with multi-grounded system such as power substations with multi-grounded overhead ground wires and/or distribution line neutrals, it is practically difficult to disconnect neutrals or skywires from the substation grounding mesh for the ground resistance measurement. In this paper, a method for the grounding performance measurement of multi-grounded systems, which is based on the measuring ground current distributions, has been proposed. A field test results has shown the validity of the proposed test method.

Review about test method for the full-insulation verification of circuit breaker rated on 800kV, 50kA (800kV, 50kA 차단기의 전절연 검증을 위한 시험방법 검토)

  • Park, Seung-Jae;Suh, Yoon-Taek;Yoon, Hack-Dong;Kim, Yong-Sik;Kim, Maeng-Hyun;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.569-571
    • /
    • 2005
  • In case of dead-tank circuit breaker with the earthed enclosure, the dielectric performance for phase to ground should be verified under the hot-gas condition produced by the current interruption. This test condition is required in breaking test duties with the rated short-circuit current and rated voltage. And, KERI has completed the reinforcement of the synthetic testing facilities and these facilities have the testing capacity which enables the full-pole testing for 800kV circuit breaker by adopting the series voltage injection method. So, this paper introduced the test circuit and procedures about the full-pole and the multi-part testing method which was devised to estimate the full -insulation of phase-to-ground for the multi-pole and dead-tank circuit breaker.

  • PDF

A Study on the Stability for the Railroad Bed and the Foundation Ground (High Landfill Slope) (철도노반과 기초지반(고성토사면) 안정에 관한 연구)

  • Oh, Myoung-Ryoul
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1391-1404
    • /
    • 2006
  • Recently, medium or slight earthquakes was occurred in the Korea Peninsula and seismic design is considered seriously in the railroad facilities as case of other civil engineering facilities. In this study, it selected the Seongnam-Yeoju railroad 6th section and seismic analysis was accomplished. Specially, unlike existing seismic analysis using the artificial earthquake and the real earthquake, seismic analysis using a seismic vibration and the train vibration was accomplished. 1-D and 2-D ground response analysis of the railroad bed and 3-D Finite element analysis in the bridge connection section of high landfill slope was accomplished. Also, slope stability analysis and the evaluation of liquefaction was accomplished.

  • PDF

Using leak coaxial cable, a wireless communications network plan in high-rise buildings (기술사마당: 기술자료 -초고층(超高層) 건물(建物) 내(內)에서 누설동축케이블을 이용한 무선통신(無線通信)네트워크 구축(構築) 방안-)

  • Lee, Soon-Jong;Lee, Moon-Ho
    • Journal of the Korean Professional Engineers Association
    • /
    • v.44 no.5
    • /
    • pp.42-47
    • /
    • 2011
  • Currently, wireless communication environment in high-rise buildings are limited in the basement and ground floor facilities are not in common use do not part, in case of disaster is difficult for efficient repression. In this paper, wireless communication facilities on the ground floor of the skyscraper by building infrastructure, wireless communications is proposed to eliminate shadows. That the presence of various wireless communication systems, wireless communication system proposed by this paper, TPS laying coaxial cable seals leak, and the propagation shades in place by installing indoor antenna is the solution to eliminate shadows. The wireless communications solutions reveal the advantages and features, a method of constructing the proposed design.

  • PDF