• Title/Summary/Keyword: On-Board Diagnosis

Search Result 95, Processing Time 0.028 seconds

A Development of Mobile Vehicle Diagnostic System on .NET System and Bluetooth (블루투스와 닷넷 시스템에서의 모바일 자동차 진단기 개발)

  • Park, Dong-Gyu;Uh, Yoon;Ha, Jae-Deok
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.10
    • /
    • pp.1436-1445
    • /
    • 2008
  • Currently, mobile handset embeds many communication modules including CDMA and Bluetooth, and many applications are developed based on these modules. In this paper, we study about wireless vehicle diagnosis software and user interface based on bluetooth system on mobile handset. We developed Bluetooth communication system on protocol converter between OBD(On Board Diagnostics)-II system. Based on this system, we can communicate ECU(Engine Control Unit) and mobile device based on windows .NET compact framework platform. Therefore we can easily diagnose vehicle state and obtain engine data. All user interface and vehicle diagnosis systems on mobile handset are developed under windows .NET compact framework platform. Using this system we achieved several improvements over existing vehicle diagnostic system; 1) the software download and upgrade can be achieve on wireless environment, 2) no additional diagnostic devices are requires, which saves additional cost and we can diagnose the vehicle easily, 3) we can easily port our system on many embedded systems including PDA and navigator, etc.

  • PDF

Self-Diagnostic Signal Monitoring System of KWP2000 Vehicle ECU using Bluetooth

  • Choi, Kwang-Hun;Lee, Hyun-Ho;Lee, Young-Choon;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.132-137
    • /
    • 2004
  • On-Board Diagnostic(OBD) systems are in most cars and light trucks on the load today. During the 1970's and early 1980's manufacturers started using electronic means to control engine functions and diagnose engine problems. The CARB's diagnostic requirements to meet EPA emission standards have been designated as OBD with a goal of monitoring all of the emissions-related components, as well as the chassis, body, accessory devices and the diagnostic control network of the vehicle for proper operation. In this paper, we present a remote measurement system for the wireless monitoring of diagnosis signal and sensors output signals of ECU adopted KWP2000, united the OBD communication protocol, on OBD-compliant vehicle using the wirless communication technique of Bluetooth. In order to measure the ECU signals, the interface circuit is designed to communicate ECU and designed terminal wirelessly according to the ISO, SAE regulation of communication protocol standard. A microprocessor S3C3410X is used for communicating ECU signals. The embedded system's software is programmed to measure the ECU signals using the ARM compiler and ANCI C based on MicroC/OS kernel to communicate between bluetooth modules using bluetooth stack. The diagnostic system is developed using Visual C++ MFC and protocol stack of bluetooth for Windows environment. The self-diagnosis and sensor output signals of ECU is able to monitor using PC with bluetooth board connected in serial port of PC. The algorithms for measuring the ECU sensor output and self-diagnostic signals are verified to monitor ECU state. At the same time, the information to fix the vehicle's problem can be shown on the developed monitoring software. The possibility for remote measurement of self-diagnosis and sensor signals of ECU adopted KWP2000 in embedded system verified through the developed systems and algorithms.

  • PDF

The development of Fetal Heart Rate monitoring system based on DSP processor (DSP 프로세서를 이용한 태아심음 및 자궁수축감시장치의 개발)

  • Jnag, D.P.;Kim, K.H.;Lee, Y.H.;Lee, Y.K.;Bak, M.I.;Lee, D.S.;Kim, S.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.320-324
    • /
    • 1996
  • Digital fetal monitoring system based on the personal computer combined with the digital signal processing board was implemented. The DSP board acquires and digitally processes ultrasound fetal Doppler signal for digital rectification, FIR filtering, autocorrelation function calculation, its peak detection and MEDIAN filtering. The personal computer interfaced with the DSP board is in charge of graphic display, hardcopy, data transmission and on-line analysis of fetal heart rate change including and variability. I used a recursive technique for autocorrelation function computation method and MEDIAN filter which can greatly reduce the amount of calculation and accuracy. I also implemented analysis algorithm of fetal heart rate change based on normal fetal sample data in order to exact diagnosis.

  • PDF

An Evaporative System Monitoring Method Using a Virtual HC Sensor (가상 HC 센서를 이용한 Evaporative System Monitoring 방법에 대한 연구)

  • 서진호;박재홍;윤형진
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.40-47
    • /
    • 2003
  • This paper presents a new evaporative system monitoring method using a virtual HC sensor for an automotive on-board diagnosis. A development was made at providing mathematical expressions from the lambda control information to estimate the HC mass flow purged into the intake manifold from the canister for implementing a virtual HC sensor. The change of the lambda averagevalue reflected the influence of the additional fuel from purging results the sensor estimation of the purged HC amount. Based on this virtual HC sensor, a new evaporative system monitoring method was proposed comparing the amount of purged HC amount with the amount of the HC gas evaporated from the fuel tank and absorbed into the canister. Finally, the method was validated with a simulation using the data logged from the retail car.

Development of a Portable Device based on PDA for Vibration Signal Analysis (PDA 기반 포터블 진동 신호 분석기 개발)

  • 김동준;박광호;기창두
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.179-184
    • /
    • 2002
  • In this study, we developed a portable device which can monitor and analyze vibration signals from machines. This system consists a PDA loading the program for vibration analysis and A/D board for vibration acquisition. A PDA is smaller than the palm of the hand, but it has a powerful computing ability as much as an IBM compatible PC with a Pentium 100MHz CPU. The A/D board developed in this study supports LAN interface using TCP/IP communication protocol. The application program for vibration analysis includes signal processing module, fault diagnosis module, data store module, and plot display module. MS visual embedded C++ 3.0 was used to developed the program.

An Acquisition and Analysis Equipment of Dynamic/Static Data on a Rotating Vibration (회전체 진동 데이터의 AC/DC 성분 데이터 획득 및 분석 장치)

  • Lee, Jung Suk;Ryu, Deung Ryeol;Lee, Cheol
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.4
    • /
    • pp.127-137
    • /
    • 2009
  • This paper is proposed that in-output Digital module is acquired a vibration signal of a rotating machinery by Data Acquisition System. The module is designed to get ride of nose through low pass filter on the vibration signal from sensors and set the gain value for being able to sampling AC to DC, and also the sampled data by sampler and the conversed data by DIP/FPGA is supplied to the analyzer for analysis at a software tool. The DIP(Digital Signal Processor) of the Digital input/output Board makes Average voltage, Peak to Peak voltage, RMS(Root Mean Square) and Gap voltage, also FFT(Fast Fourier Transform) for rotating vibration diagnosis.

Eustachian tube calcification as an unusual finding on a panoramic radiograph

  • Galal Omami
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.105-107
    • /
    • 2024
  • The author herein presents an unusual case of eustachian tube calcification masquerading as loose radiopacities in the temporomandibular joints on a panoramic image, creating a diagnostic challenge. The patient, a 72-year-old woman, presented to the dental service for implant treatment to improve her masticatory function. A cone-beam computed tomography scan was performed and reviewed by a board-certified oral and maxillofacial radiologist. The scan showed no evidence of calcifications in the temporomandibular joints; however, it revealed nodular calcifications within the cartilaginous portion of the eustachian tube bilaterally. Additionally, this report briefly reviews the differential diagnosis of calcified loose bodies in the temporomandibular joint and provides information that needs to be reinforced periodically.

A study on Development of Remote Vehicle Fault Diagnostic System (원격 자동차 고장 진단 시스템 개발에 대한 연구)

  • Nkenyereye, Lionel;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.224-227
    • /
    • 2015
  • Data transmission via the car driver's tethered smart phone may have a volume-dependent billing in case car driver' phone transmits data in real-time to the remote data center. The on-board diagnosis data generated are temporary stored locally to mobile remote diagnosis application on the car driver's phone, and then transmit to the data center later when car driver connects to the Internet. To increase the easiest of using the remote vehicle application without blocking other tasks to be executing on the cloud, node.js stands as a suitable candidate for handling tasks of data storage on the cloud via mobile network. We demonstrate the effectiveness of the proposed architecture by simulating a preliminary case study of an android application responsible of real time analysis by using a vehicle-to- smart phones applications interface approach that considers the smart phones to act as a remote user which passes driver inputs and delivers output from external applications. In this paper, we propose a study on development of Remote Vehicle fault diagnostic system features web server architecture based event loop approach using node.js platform, and wireless communication to handle vehicle diagnostics data to a data center.

  • PDF

A Study on the integrity assessment of the high voltage transformer with Dissolved Gas Analysis (특고압 변압기 건전성 평가에 관한 연구)

  • Lee, Il-Moo;You, Sang-Bong;Joung, Hea-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1463-1464
    • /
    • 2015
  • This paper describes for the diagnosis insulating oil for transformers integrity assessment. The high-capacity oil transformer has several insulators are entered for the purpose of insulation, such as insulating oil, insulating paper and press board. Irradiated with a gas component dissolved in the insulating oil can analyze the status of the transformer, and can prevent a sudden accident in advance.

  • PDF

Quality Assuarance on Fine Needle Aspiration Cytology of Malignant Salivary Gland Neoplasms (악성 침샘종양의 세침흡인 세포검사의 정도관리)

  • Oh, Young-Lyun;Ko, Young-Hyeh
    • The Korean Journal of Cytopathology
    • /
    • v.15 no.1
    • /
    • pp.40-44
    • /
    • 2004
  • To evaluate the quality of fine needle aspiration cytology diagnosis on malignant salivary gland neoplasms, cytologic findings were correlated with histologic diagnosis of 56 surgically removed malignant salivary gland tumors. Seven cases (12.5%) were insufficient, 23 cases (41.1%) were diagnosed as malignant, 17 (30.4%) cases were accurately diagnosed by histologic subtype, and 9 cases (16%) were diagnosed as benign. Five out of 9 false negative cases were misdiagnosed as pleomorphic adenomas. Except the cases with insufficient specimen, overall sensitivity was 81.6%, and the sensitivity varied according to the histologic subtype; 91% in salivary duct carcinoma, 100% in carcinoma ex pleomorphic adenoma, 50% in mucoepidermoid carcinoma, 63% in adenoid cystic carcinoma, and 50% in acinic cell carcinoma. The diagnostic accuracy differed among cytopathologists irrespective of periods after acquisition of board of pathologists. These results confirm that salivary gland neoplasm can be easily misdiagnosed in fine needle aspiration cytology and a great caution should be given in diagnosing the benign appearing salivary aspirates to avoid under-diagnosis of malignant neoplasm with low grade cytologic atypia.