• Title/Summary/Keyword: On Resistance

Search Result 21,498, Processing Time 0.055 seconds

A Study on the Correlation Evaluation of Confining Pressure and Pile-Soil Interface Strength Reduction Factor Using Numerical Analysis (수치해석에 의한 지중 구속압과 말뚝-지반 경계면 강도감소계수 관계 분석)

  • Tae-Gyeom Lee;Jung-Geun Han;Gigwon Hong;Seung-Kyong You
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.1
    • /
    • pp.9-16
    • /
    • 2024
  • In order to evaluate the relationship between the ground confining pressure and the shear characteristics of the pile-soil interface, this study described the comparative results of the existing experimental results and the FEA results using the strength reduction factor. The strength reduction factor was applied to simulate the shear behavior of the pile-soil interface in finite element analysis(FEA). The analysis results showed that the maximum pullout resistance decreased due to the influence of low confining pressure, as the fines content increased. This trend was similar to the previous experimental research, and this FEA model simulated with the interface strength reduction factor was evaluated as reasonable. The analysis results of the variation in the interface strength reduction factor clearly showed that the interface strength reduction factor clearly increased at a high fines content when the confining pressure was 50kPa. However, it was found that the increase rate was low when the confining pressure was 100kPa and 150kPa. Therefore, confining pressure and fines content need to be considered in FEA to evaluate the shear behavior of the pile-soil interface.

Antimicrobial Photodynamic Therapy on Pseudomonas aeruginosa Using a Diode Laser and PhotoMed, Methyl Pheophorbide A, or Radachlorin® (다이오드 레이저와 PhotoMed, Methyl Pheophorbide A, Radachlorin®을 이용한 녹농균에 대한 항균 광역학 요법)

  • Young-Kyu SONG;Keun-Dol YOOK;Ji-Won KIM
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.1
    • /
    • pp.52-58
    • /
    • 2024
  • Photodynamic therapy (PDT) activates intracellular oxygen using a photosensitizer activated by light of a specific wavelength and is a potential means of treating wound infections caused by antibiotic-resistant bacteria. Pseudomonas aeruginosa (P. aeruginosa) is typically non-pathogenic in healthy individuals but can induce severe illnesses like sepsis in the immunocompromised. Antibiotics have been conventionally used to treat P. aeruginosa infections, but increasing antibiotic resistance caused by drug misuse poses a growing challenge to the management of these infections. This study aimed to investigate the ability of PDT using photosensitizers (PhotoMed, Methyl pheophorbide A, or Radachlorin®) and a diode laser to inhibit P. aeruginosa. Suspensions of P. aeruginosa and a photosensitizer were inoculated into Petri dishes and incubated for 30 minutes. Samples were then irradiated with the laser at 3 J/cm2, and after incubation, colony areas were measured. P. aeruginosa killing rates were 79.65% for PhotoMed, 47.36% for Methyl pheophorbide A, and 40.91% for Radachlorin®. This study shows that PDT using a diode laser and a photosensitizer constitutes an effective practical therapeutic approach for inhibiting P. aeruginosa.

Water-blocking Asphyxia of N95 Medical Respirator During Hot Environment Work Tasks With Whole-body Enclosed Anti-bioaerosol Suit

  • Jintuo Zhu;Qijun Jiang;Yuxuan Ye;Xinjian He;Jiang Shao;Xinyu Li;Xijie Zhao; Huan Xu;Qi Hu
    • Safety and Health at Work
    • /
    • v.14 no.4
    • /
    • pp.457-466
    • /
    • 2023
  • Background: During hot environment work tasks with whole-body enclosed anti-bioaerosol suit, the combined effect of heavy sweating and exhaled hot humid air may cause the N95 medical respirator to saturate with water/sweat (i.e., water-blocking). Methods: 32 young male subjects with different body mass indexes (BMI) in whole-body protection (N95 medical respirator + one-piece protective suit + head covering + protective face screen + gloves + shoe covers) were asked to simulate waste collecting from each isolated room in a seven-story building at 27-28℃, and the weight, inhalation resistance (Rf), and aerosol penetration of the respirator before worn and after water-blocking were analyzed. Results: All subjects reported water-blocking asphyxia of the N95 respirators within 36-67 min of the task. When water-blocking occurred, the Rf and 10-200 nm total aerosol penetration (Pt) of the respirators reached up to 1270-1810 Pa and 17.3-23.3%, respectively, which were 10 and 8 times of that before wearing. The most penetration particle size of the respirators increased from 49-65 nm before worn to 115-154 nm under water-blocking condition, and the corresponding maximum size-dependent aerosol penetration increased from 2.5-3.5% to 20-27%. With the increase of BMI, the water-blocking occurrence time firstly increased then reduced, while the Rf, Pt, and absorbed water all increased significantly. Conclusions: This study reveals respirator water-blocking and its serious negative impacts on respiratory protection. When performing moderate-to-high-load tasks with whole-body protection in a hot environment, it is recommended that respirator be replaced with a new one at least every hour to avoid water-blocking asphyxia.

Analysis of Ecological Connectivity of Forest Habitats Using Spatial Morphological Characteristics and Roadkill Data (공간형태학적 특성 및 로드킬 자료를 활용한 산림서식지의 생태적 연결성 분석)

  • Hyunjin Seo;Chulhyun Choi;Seungwon Lee;Jinhyo Kim
    • Korean Journal of Ecology and Environment
    • /
    • v.57 no.2
    • /
    • pp.75-82
    • /
    • 2024
  • This study examined the spatial morphological patterns of forest habitats and the characteristics of roadkill occurrences in the forests of Mungyeong, Yecheon, Yeongju, Andong, and Bonghwa in Gyeongsangbukdo. It involved building a resistance map between habitats and analyzing connectivity based on the least-cost distance. The analysis of the distance between the forest habitat Cores derived from MSPA and roadkill points showed that roadkill occurrences were concentrated approximately 74.11 m away from the Cores, with most roadkills happening within 360m from the habitats. The connectivity analysis between core habitats larger than 1 km2 revealed 141 core habitats and 242 least-cost paths between them. The corridor distance value was found to be highest in Mungyeong city, indicating an urgent need for strategies to enhance habitat connectivity there. This research is expected to serve as foundational data for developing strategies to enhance ecosystem connectivity and restore habitats, by analyzing ecosystem connectivity and roadkill issues due to habitat fragmentation.

Fire Resistant Properties of the RC Columns Applying Various Splling Prevention Methods (폭렬방지공법 변화에 따른 RC 기둥부재의 내화특성)

  • Han, Cheon-Goo;Pei, Chang-Chun;Lee, Jong-Suk;Lee, Chan-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.119-126
    • /
    • 2009
  • This study investigated the fire resistance of RC columns applying Fiber addition method, Fire board attaching method, and Fire proof sparying method. The results were summarized as following. The test showed that increase of fiber content, as expected, decreased the fluidity of fresh concrete, but for the types of fiber, the specimens containing nylon(NY) was favorable. The incline of fiber content also affected on the air content of concrete, which the specimens adding polypropylene(PP) fiber was the lowest, followed by a less decrease in polyvinyl alchhol(PVA) and then NY respectively. For the compressive strength at 28days, it was over 50MPa and showed slight increasing tendency by rising fiber contents. After the fire test completed, control concrete exhibited the severe demage, while the specimens containing more than 0.05vol.% of PP and NY was able to protect from spalling. In the case of splay, the partly spalling occurred at the all finishing material, however the RC columns were protected from spalling. For the methods attached with boards, all RC columns were protected except the dry attaching method. The reduced weight ratio was favorable because it was below 8 % except for plain concrete.

Experimental Study on Combined Failure Damage of Bi-directional Prestressed Concrete Panel under Impact-Fire Loading (충돌 후 화재에 대한 이방향 프리스트레스트 콘크리트 패널부재의 복합 파괴손상에 관한 실험적 연구)

  • Yi, Na-Hyun;Lee, Sang-Won;Choi, Seung-Jai;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.429-440
    • /
    • 2014
  • Since the World Trade Center and Pentagon attacks in 2001, terror, military attack, or man-made disaster caused impact, explosion, and fire accident have frequently occured on civil infrastructures. However, structural behavior researches on major Prestressed Concrete (PSC) infrastructures such as bridges, tunnels, Prestressed Concrete Containment Vessel (PCCVs), and LNG tanks under extreme loading are significantly lacking. Especially, researches on possible secondary fire scenarios after terror, bombing, collision of vehicles and vessels on concrete structures have not been performed domestically where most of the past researches related to extreme loadings on structures focused on an independent isolated extreme loading scenario. Due to the outcry of public concerns and anxiety of potential terrorist attacks on major infrastructures and structures, a study is urgently needed at this time. Therefore, in this study, the bi-directional prestressed concrete $1400{\times}1000{\times}300mm$ panels applied with 430 kN prestressing force using unbonded prestressing thread bars were experimentally evaluated under impact, fire, and impact-fire combined loadings. Due to test site restrictions, impact tests were performed with 14 kN impactor with drop heights of 10m and 3.5 m to evaluate impact resistance capacity. Also, fire and impact-fire combined loading were tested using RABT fire loading curve. The measured residual strength capacities of PSC and RC specimens applied with impact, fire, impact-fire combined loadings were compared with the residual strength capacity of undamaged PSC and RC specimens for evaluation. The study results can be used as basic research data for related research areas such as protective design and numerical simulation under extreme loading scenarios.

Effect of Whalakyuoleyng-dan plus Yinsamyangwui-tang on Anti-angionesis (활락효영단합인삼양위탕(活絡效靈丹合人蔘養胃湯)이 혈관신생(血管新生) 억제(抑制)에 미치는 영향(影響))

  • Ko, Ki-Wan;Park, Joon-Hyuk;Kang, Hee;Kim, Sung-Hoon;Yu, Young-Beob;Shim, Bum-Sang;Choi, Seung-Hoon;Ahn, Koo-Seok
    • THE JOURNAL OF KOREAN ORIENTAL ONCOLOGY
    • /
    • v.7 no.1
    • /
    • pp.77-97
    • /
    • 2001
  • Anti-angiogenesis is one of therapies which have been high-lightened on the research of cancer treatment. Anti-angiogenesis means that new blood vessels are created from a existing capillary tube and it is a important process on metastasis and permeation when cancer is created or formed. Since angiogenesis have been under research, a complete recovery oriented treatment against cancer have been suggested blocking metastasis, delaying the growth of cancer cell, and blocking the supply of oxygen and nutritive substance through the web of blood vessels. Until now, there are several anti-angiogenesis, which have been known to the public, such as thalidomide, angiostatin, endostatin, 2-methoxyestradiol, TNP-470, and marimastat, etc. Additionally, 17 clinical testing projects about anti-angiogenesis are on the process in NCI(National Cancer Institute). Especially, TNP-470 showed effectiveness against cancer on clinical testing after finishing animal testing. Based on existing researches showing that Yinsamyangwui-tang is effective to strengthening body resistance and Whallakhyolenyng-dan effects cells on the inside of blood vessel because Whallakhyolenyng- dan restrains cell adhesion during the restraining period of a blood vessel, I tried to research the effect of Whalakhyolenyng-dan plus Yinsamyangwui-tang on angiogenesis. I made a conclusion putting into operation through using SK-Hep-1 (KCLB 30052), A549(KCLB 10185), AGS(KCLB 21739), and BCE(Bovine Capillary Endothelial Cell). Followings are the results of my experimental research: 1. According to the researching results of anti-cancer activation against cancer cell, Whallkhyoleyng dan plus Yinsamyangwui-tang decreased the number of cancer cells -- While injecting $600{\mu}g/ml$, injected groups decreased 3.1% more comparing with the contrastive group of SK-Hep-1, 49.7% more comparing with the contrastive group of A549, and 31.0% more comparing with the contrastive group of AGS. 2. According to the researching results of DNA composition effect between BCE and cancer cell, Whallakhyoleyng-dan plus Yinsamyangwui-tang reduced the rate of SK-Hep-1 synthesis inhibition by 59.1% at $600{\mu}g/ml$ intensity comparing with contrastive group; for A549, 72.6%; for AGS, 6.1%, for BCE, 28.9%. 3. According to the researching results about the effect of BCE cell to angiogenesis, angiogenesis was restrained at $400{\mu}g/ml$ intensity during 18 hours observation. 4. In the case of aortic ring assay, the half level of angiogenesis was reduced comparing with the contrastive group while injecting with $400{\mu}g/ml$ intensity; with $800{\mu}g/ml$, under 10% comparing with contrastive group; and with $1600{\mu}g/ml$, complete restrain. According to the above results, Whallakhyoleyng-dan plus Yinsamyangwui-tang was proved to have an anti-angiogenetic effects.

  • PDF

A Study on Trust Transfer in Traditional Fintech of Smart Banking (핀테크 서비스에서 오프라인에서 온라인으로의 신뢰전이에 관한 연구 - 스마트뱅킹을 중심으로 -)

  • Ai, Di;Kwon, Sun-Dong;Lee, Su-Chul;Ko, Mi-Hyun;Lee, Bo-Hyung
    • Management & Information Systems Review
    • /
    • v.36 no.3
    • /
    • pp.167-184
    • /
    • 2017
  • In this study, we investigated the effect of offline banking trust on smart banking trust. As influencing factors of smart banking trust, this study compared offline banking trust, smart banking's system quality, and information quality. For the empirical study, 186 questionnaire data were collected from smart banking users and the data were analyzed using Smart-PLS 2.0. As results, it was verified that there is trust transfer in FinTech service, by the significant effect of offline banking trust on smart banking trust. And it was proved that the effect of offline banking trust on smart banking trust is lower than that of smart banking itself. The contribution of this study can be seen in both academic and industrial aspects. First, it is the contribution of the academic aspect. Previous studies on banking were focused on either offline banking or smart banking. But this study, focus on the relationship between offline banking and online banking, proved that offline banking trust affects smart banking trust. Next, it is the industrial contribution. This study showed that offline banking characteristics of traditional commercial banks affect the trust of emerging smart banking service. This means that the emerging FinTech companies are not advantageous in the competition of trust building compared to traditional commercial banks. Unlike traditional commercial banks, the emerging FinTech is innovating the convenience of customers by arming them with new technologies such as mobile Internet, social network, cloud technology, and big data. However, these FinTech strengths alone can not guarantee sufficient trust needed for financial transactions, because banking customers do not change a habit or an inertia that they already have during using traditional banks. Therefore, emerging FinTech companies should strive to create destructive value that reflects the connection with various Internet services and the strength of online interaction such as social services, which have an advantage over customer contacts. And emerging FinTech companies should strive to build service trust, focused on young people with low resistance to new services.

  • PDF

A Study on the Bed Climate and the Physiological Responses in Sleep. - On Ondol Environment - (수면시 침상기후와 인체생리반응에 관한 연구 -온돌환경을 중심으로-)

  • Kim Myung Ju;Choi Jeong Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.2 s.38
    • /
    • pp.77-87
    • /
    • 1991
  • The purpose of this study were to investigate the bed climate and the physiological responses in sleep on the traditional Korean floor heating system called Ondol. Ondol has been the most widely used heating system in Korea, yet there has been a no systematic studies examined its environmental effects on human body. Experimental room was constructed to match the typical thermal environment of Ondol. (floor surface temperature; $32\~33^{\circ}C$, air temperature; $22.5{\pm}1.0^{\circ}C$, relative humidity; $64.0{\pm}4.0\%$RH, air velocity; 0.25 m/sec.) Three different combinations of bedclothes were chosen for the experiment based on the study results showing that they were the most widely used types in Korea. Type 1 was the combination of a cotton-padded mattress with a cotton-padded Korean style blanket. Type 2 was a cotton-padded mattress with a cotton-guilted Korean style blanket. Type 3 was a cotton-padded matless with a polyacryl blanket. Thermal resistance of each of these combina-tions in the bedclothes was measured using thermal manikin. Two adult female was chosen for the seven hour sleeping experiment which was known to be the average sleeping hours of Korean adult female. The bed climate was measured with the temperature under the mattress, the surface temper-ature of the mattress, and the air temperature and the relative humidity of the space between the mattress and blanket. The skin temperature, rectal temperature of the subjects and the bed climate were measured eight times, one hour before the experiment and every hour during the experiment. The weight loss and the subjective sensation were measured for the each subjects before and after the experiment. The procedure was repeated twice with two subjects and three types of bedclothes, yielding twelve combinations of results. The results were as follows; 1. With the surface temperature of $32\~33^{\circ}C$ of Ondol, air temperature was $22.5{\pm}1.0^{\circ}C$ with $64.0{\pm}4.0\%$ RH. The bed climates were $39.2{\pm}40.8^{\circ}C$ under the mattress, $35.3\~36.2^{\circ}C$ on the mattress, and $26.9\~32.0^{\circ}C$ with $56.0\~71.3\%$ RH between the mattress and the blanket. 2. Mean skim temperature during sleep was 34.2"C with local skin temperature of $34.0\~35.5^{\circ}C$. The skin temperatures of abdomen, thigh, foot were higher than the other parts of the body. 3. The skin temperature of chest, thigh, leg and back varied significantly according to the combinations of bedclothes. With the cotton-padded blanket, the skin temperature was the highest, while with the cotton-guilted blanket showed lowest. 4. Examining the relationship between the mean skin temperature and the local skin temper-ature, the chest temperature showed the highest correlation with the former. Therefore, the chest temperature can be recommended to represent the skin temperature in measuring the bed climate. 5. The subjective bed climates were $39.0\~40.4^{\circ}C$ under the mattress, $35.2\~35.9^{\circ}C$ on the mattress, $29.8\~31.6^{\circ}C$ with $56.8\~68.4\%$ RH between the mattress and blanket. In sum, from this experiment we not only obtained the reliable value of bed climates on Ondol, but also showed that the bed climates and the physiological responses were affected differently according to the materials of bed clothes.

  • PDF

A Study on Facilities Damage Characteristics Caused by Forest Fire in Goseong-Gun (고성산불로 인한 시설물피해특성 연구)

  • Yeom, Chanho;Lee, Si-young;Park, Houngsek;Kwon, Chungeun
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.469-478
    • /
    • 2019
  • Purpose: In this studies we examine the facilities damage characteristics caused by forest fire. Therefore, we surveyed damaged facilities from forest fire which was occurred on Goseong-Gun on march 28 in 2019.(damaged areas was 40ha) The types of facilities uses were house, public facility, warehouse and so on. 17 facilities were destroyed. The purpose of this study was to for establishing a disaster safety village in rural areas where damage from a similar type of disaster occurs repeatedly by conducting the consciousness survey targeting at experts and disaster safety officials in a local government. Method: We surveyed meteorological factors(temperature, wind speed, wind direction, humidity) per a minute for analyzing weather condition on Goseong-Gun when forest fire was occurred, spread and extinguished. And we surveyed forest fire risk factors(a slope degree, a slope direction, a geographical feature, a distance between forest and facility, main species, the existence of crown fire ignition, the direction of facility, the main material of building) around 10 damaged facilities. Finally, we analyzed damage pattern of facilities using meteorological factor and forest fire reisk fator Result: The weather condition of Kanseonng AWS (No.517) was high temperature, arid and strong wind, when the forest fire was occurred and spread. An average wind speed was 4.1m/s and the maximum wind speed was 11.6m/s. The main direction of wind was W(225~315°). Damaged facilities were located on the steep slope area and on the mountaintop. The forest density around facilities was high and main species was korean red pine. The crown fire was occurred in the forest around damaged facilities. The average distance was 13.5m from forest to facilities. When the main matarial of building was made by fire resistance materials (for example, rainforced concrete), the damage was slightly. on the other hand, when by flammable material (for example, a Sandwich Panel), the facilities were totally destroyed Conclusion: The results of this research which were the thinning around house, making a safety distance, the improvement of main material of building and etc, will be helpful for establishing a counter measure for a forest fire prevention of facilities in wild land urban interface