• 제목/요약/키워드: On/Off valve

검색결과 252건 처리시간 0.03초

전기유압식 서보인덱싱 시스템의 PWM 제어에 관한 연구 (A Study on PWM Control of an Electro-Hydraulic Servo Indexing System)

  • 허준영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.236-243
    • /
    • 1999
  • This study deals with the application of high speed on-off valves to an electro-hydraulic servo indexing system incorporated electro-hydraulic servo valces. Comparing with the electro-hydraulic servo valve the high speed on-off valve has some merits. Which included low price robustness to the oil contamination and dircect control without D/A converter. The considered sys-tem of this study is controlled by pulse width modulation(PWM) of the control law which is pro-duced by a PID controller which is used broadly in industrial equipments. The dynamic character-istics corresponding to variations of system parameters such as inertia moment system gain and supply pressure are investigated by computer simulation and experiment. Consequently the availability of the application of high speed on-off valve to servo indexing system instead of electro-hydraulic servo valve is confirmed.

  • PDF

개폐식 밸브를 사용한 공기압 서보 시스템의 효율적 밸브 개폐 방법에 관한 연구 (Study on the Effective Operating Method of on-off Valves for a Pneumatic Servo System)

  • 황웅태;최서호;이정오
    • 한국정밀공학회지
    • /
    • 제15권1호
    • /
    • pp.109-116
    • /
    • 1998
  • This paper is concerned with effective operating method of pneumatic on-off valves for improving position control accuracy, valve life-time and position settling time using modified pulse width modulation with dead-zone (MPWMD). The pneumatic system using on-off valves has advantage of simple construction and low cost compared with a system with servo-valves. The performance of the proposed control method is investigated experimentally for the position control of a pneumatic cylinder using on-off valves. Experimental results show that the proposed algorithm for valve operation can be used to obtain fast and accurate position control compared to the conventional PWMD algorithm. It is also shown that the use of the proposed MPWMD algorithm for the position control significantly reduces the number of valve switching and noise.

  • PDF

3위치 솔레노이드 벨브를 이용한 유압 조타 장치의 제어에 관한 연구 (A Study on a Control of Hydraulic Steering Gear by Using Three-Position Solenoid Valve)

  • 심성효;이학도
    • 수산해양기술연구
    • /
    • 제34권2호
    • /
    • pp.231-237
    • /
    • 1998
  • Generally, the three position solenoid valve has veen used for the hydraulic steering gear on account of it’s low cost, simplicity in device, etc. But, there is some off-set because of dead-zone which exists in on-off valves. In this paper, we proposed a combined controller which was added an integral controller to an only on-off one in hydraulic steering gear control system used low speed three position solenoid valve. Experimental results show that the off-set is removed, and the number of valve switching is reduced considerable. The validity of proposed method comparing with an only on-off control was proved by the response experiments.

  • PDF

고속 온.오프 전자밸브를 사용한 유압실린더 힘 제어계의 응답성 개선 (Response Improvement in Hydraulic Cylinder Force Control System by Using a High Speed On-Off Electro-Magnetic Valve)

  • 이일영;권정호;박정환
    • 유공압시스템학회논문집
    • /
    • 제1권4호
    • /
    • pp.15-21
    • /
    • 2004
  • High speed on-off electro-magnetic valves have been used for pressure control or flow control in automotive or construction machine servomechanisms. These systems require quicker valve switching speed to improve control preciseness. The authors designed and manufactured an electric valve driver with quick response characteristics by using 3 power source type valve driver concept. In experiments by using a hydraulic system incorporating the new valve driver, the new driver shortened the switching lag time from 5 ms to 1.3 ms. And also the new driver showed excellent position tracking control performances.

  • PDF

고압가스 사용시설 내 안전밸브 설치유형별 리스크 분석 (Risk Analysis for Installation Types of Pressure Safety Valve used in the High-pressure Gas Facility)

  • 김명철;우정재;이형섭;백종배
    • 한국안전학회지
    • /
    • 제32권4호
    • /
    • pp.129-136
    • /
    • 2017
  • This study investigated the probability of possible accident through qualitative and quantitative analysis of the pressure safety valve types installed in facilities using high pressure gas to compare the installation domestic and foreign pressure safety valve standards sought the safety characteristics and safety improvement direction accordingly. The three types are the case where the shut-off valve is not installed at the front of the PSV (Case A), If a shut-off valve is installed at the front of the PSV for inspection (Case B) and If a shut-off valve is installed in front of PSV (C.S.O), PSV is installed in parallel (Case C). Three types of cases were compared with FTA and HAZOP. The results of study of the possible accidents due to over-pressure safety valve installation type, used in a high-pressure gas facilities was shows in the following order Case B > Case A > Case C. The results of analysis through FTA was in order to protect the reservoir for the possible occurring of accident the safety valve installation is depend on its type. In the FTA analysis, defects in the device itself which attached to the storage tank as a substitute for analysis of the probability of operator mistakes was Case B with as high as $2.01{\times}10^{-6}$. Depending on the type of installation analysis of Case B in order to ensure safety is prohibited to install shut-off valve and believes that mandatory regulations are needed. Rationally installing of pressure safety valve in the high pressure using facilities will be expected to improve the industrial safety from severe accidents such as high-pressure gas fire explosion.

고속전자밸브를 사용한 유압장치의 주파수응답특성에 관한 연구 (A Study on the Frequency response charcteristics of Hydraulic Equipment using High speed on-off valve)

  • 허준영
    • 한국정밀공학회지
    • /
    • 제12권2호
    • /
    • pp.79-86
    • /
    • 1995
  • Frequency response method is used to design hydraulic servo systems and improve its performance. In this study a method is proposed to get simply the frequency response of the electro-hydraulic servo system which use PWM controlled high-speed on-off valves. Firstly, the describing function of the PWM element is derived and tested. It is found that the character- istic of PWM element could be approximated to a saturation characteristic in the range of allowable frequency. And the dynamic characteristic of the valve-cylinder system could be negligible. The working characteristic of high-speed on-off valve is considered as time delay. So simulation is performed in the basis of the reconstructed block diagram. And this method is verified by experiments.

  • PDF

PWM 제어되는 유압장치의 안정성 해석 (A Study Stability Analysis of a PWM Controlled Hydraulic Equipment)

  • 허준영
    • 대한기계학회논문집
    • /
    • 제19권6호
    • /
    • pp.1469-1478
    • /
    • 1995
  • PWM control is a kind of nonlinear control. The merits of PWM control of hydraulic equipment are the robustness of the high speed on-off valve and its low price. And it is easily implemented to hydraulic equipments with microcomputer. The high speed on-off valve is directly digitally controlled without any D/A converter. The objectives of this study is to analyze the limit cycle which regularly appear in the position control system using high speed on-off valve, and to give a criterion for the stability of this system. To do this, the nonlinear characteristics of PWM and cylinder friction of this system are described by harmonic linearization and the effects of parameter variations to the system stability are examined theoretically and experimentally. Consequently, the availability of the proposed method is confirmed well.

2단계 개방 연소기 산화제 개폐밸브 개발 (Development of a Two-Step Main Oxidizer Shut-off Valve)

  • 홍문근
    • 한국항공우주학회지
    • /
    • 제45권8호
    • /
    • pp.704-710
    • /
    • 2017
  • 액체로켓엔진용 연소기 산화제 개폐밸브는 단순 온 오프 개폐작동을 통해 연소기로의 산화제 공급 유무만을 제어하기 때문에, 산화제 공급 유량 조절을 통한 엔진 점화 시동 특성제어 및 최적화에 한계가 있는 반면에 2단계 개방 연소기 산화제 개폐밸브는 밸브의 부분 개방에 의해 산화제 공급 유량을 조절함으로써 엔진 점화 시동 특성을 제어할 수 있는 이점이 있다. 이에 본 논문에서는 액체로켓엔진용 2단계 개방 연소기 산화제 개폐밸브 개발을 위한 기본 설계 내용과 함께 밸브 작동성에 관한 검증시험 결과를 소개하기로 한다.

발사체 연소기용 산화제 개폐밸브의 핵심요소 기술 개발 (Study for the Development of a Main Oxidizer Shut-off Valve for Liquid Rocket Engines)

  • 김도형;홍문근;박재성;이수용
    • 한국추진공학회지
    • /
    • 제17권6호
    • /
    • pp.113-119
    • /
    • 2013
  • 발사체 연소기용 산화제 개폐밸브는 비교적 간단한 개폐 작동을 통해, 액체산소를 연소기에 공급 또는 차단한다. 고압, 고유량, 극저온의 액체산소를 운용 유체로 사용할 뿐만 아니라, 설계유량 대비 밸브 차압 또한 낮아야 하는 상당히 까다로운 개발요구조건을 가지고 있다. 본 논문에서는 현재 개발 중인 연소기용 산화제 개폐밸브의 밸브 과도 응답과 같은 기본적인 밸브 특성과 함께, 밸브 성능을 좌우하는 핵심 부분이라고 할 수 있는 밸브 공압 구동부 및 포핏/시트부의 개발 내용을 소개하였다. 밸브의 과도 응답 특성 해석 결과가 시험 측정결과와 매우 잘 일치하는 것을 확인하였으며, 구동 공압부 및 포핏/시트부 구조해석을 통해 밸브 무빙파트의 접촉면 반발력과 마찰력을 정량적으로 평가하였다.

밸브 구동용 개폐식 솔레노이드 액추에이터의 설계 (A Design of On/Off Type Solenoid Actuator for Valve Operation)

  • 성백주
    • 유공압시스템학회논문집
    • /
    • 제6권4호
    • /
    • pp.24-32
    • /
    • 2009
  • For a design of on/off solenoid actuator for valve actuating, designer must have the experimental knowledge as well as general electromagnetic formulas to design object. It is possible for theoretical knowledge to do the out-line design, but it is impossible to optimal design without experimental knowledge which only can be achieved through many repeated experiments. In addition, in present on/off type solenoid actuator field, the smaller, lightening, lower consumption power, high response time are effected as the most important design factor. So, experimental knowledge is more needed for optimal design of solenoid actuator. In this study, we derived the governing equations for optimal design of on/off solenoid actuator for valve actuating and developed a design program composed electromagnetic theories and experimental parameter values for inexperienced designers. And we proved the propriety of this program by experiments.

  • PDF