• Title/Summary/Keyword: Oil-immersion lens

Search Result 6, Processing Time 0.016 seconds

Analysis of Optical Characteristics of Oil Immersion Lens in Aqueous Environment (액상유체 오일 이멀전 렌즈의 광학 물성치 해석)

  • Choi, Hae Woon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.11
    • /
    • pp.18-23
    • /
    • 2019
  • The oil immersion method can be used to create objective lenses with long working distances without sacrificing the focusing resolution for laser processing. In this study, a space in which air or oil can be filled was formed in the middle of a lens for analyzing the optical properties of a liquid-oil immersion lens. As the refractive media, air and oils of different refractive index values (1.2 and 1.5, respectively) were used. A simulation was conducted in the ZEMAX software environment using the ray-tracing technique, and the performance of the oil immersion lens was verified by determining its image distortion and focal length (FL) in each medium. In the case of air, the calculated FL was 0.813 mm, whereas the imaged FLs were 1.594 mm and 8.126 mm when the refraction indices were 1.2 and 1.5, respectively. The FL of an oil immersion lens could be increased considerably. In terms of image distortion, the oil immersion lens exhibited little distortion at the center in all cases, but different degrees of image distortion were observed at different points away from the center depending on the refraction index degree.

Measurement of the Internal Structure of an Optical Waveguide Embedded in a Flexible Optical Circuit Board by Enhancing the Signal Contrast of a Confocal Microscope

  • Lee, Won-Jun;Kim, Dae-Chan;O, Beom-Hoan;Park, Se-Geun;Lee, El-Hang;Lee, Seung-Gol
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2011
  • In this study, the internal structure of an optical waveguide embedded in a flexible optical circuit board is observed with a confocal microscope. In order to increase the light reflection from an internal material interface with a very small index difference, and thus enhance the signal contrast, a theta microscopy scheme has been integrated into a conventional confocal microscope, and a high NA oil-immersion lens has been used. The interface reflectivity is increased from roughly 0.0015% to 0.025% by the proposed method, and the internal structure can thus be successfully measured.

Stable lateral-shearing interferometer for in-line inspection of aspheric pick-up lenses (생산 라인에서의 광 Pick-up용 비구면 대물 렌즈 측정을 위한 안정된 층밀리기 간섭계)

  • 조우종;김병창;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.189-193
    • /
    • 1997
  • Aspheric pick-up lenses are increasingly used in consumer products such as computer and multimedia, as their mass production has become possible owing to the injection molding process. However still much work needs to be done for more effective manufacture of aspheric lenses, one area of which is the in-line inspection of produced lenses. In this paper, we present a lateral-shearing interferometer that has specially been designed to have a high immunity to external vibration and atmospheric disturbance. The interferometer comprises four prisms. They are directly attached to each other using an immersion oil so that relative sliding motions between the prisms are allowed. Their relative displacement can readily generate necessary lateral-shearing and phase-shifting to determine the wavefront of the beam collimated by the lens under inspection. A special phase-measuring algorithm of arbitrary-bucket is adopted to compensate the phase-shifting error caused by the thickness reduction in the immersion oil. Zernike polynomial fitting has done for determinating quantitative aberration of aspheric pick-up lenses. The interferometer built in this work is robust to external mechanical vibration and atmospheric disturbance so that experimental results show that it has a repeatability of less than λ/100.

  • PDF

Direct Patterning of 3D Microstructures on an Opaque Substrate Using Nano-Stereolithography (나노 스테레오리소그래피 공정을 이용한 불투명 기판에서의 3차원 마이크로 형상 제작 방법에 관한 연구)

  • Son, Yong;Lim, Tae-Woo;Ha, Cheol-Woo;Yang, Dong-Yol;Jung, Byung-Je;Kong, Hong-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.10
    • /
    • pp.93-99
    • /
    • 2010
  • A nano-stereolithography is the direct patterning process with a nanoscale resolution using twophoton absorption induced by a femtosecond laser. However, in the majority of the works, the fabrication of 3D microstructures have been done only onto transparent glass due to the use of an oil immersion objective lens for achieving a high resolution. In this work, the coaxial illumination and the auto-focusing system are proposed for the direct patterning of nano-precision patterns on an opaque substrate such as a silicon wafer and a metal substrate. Through this work, 3D polymer structures and metallic patterns are fabricated on a silicon wafer using the developed process.

Clinical Significance of Argyrophilic Nucleolar Organizer Regions(AgNORs) In Squamous Cell Carcinoma of the Lung (편평세포폐암에서 Argyrophilic Nucleolar Organizer Regions(AgNORs)의 임상적의의)

  • Han, Seung-Beom;Jeon, Young-June;Lee, Sang-Sook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.513-521
    • /
    • 1995
  • Background: Nucleolar organizer regions(NORs) are chromosomal segments encoding for ribosomal RNA and associated with argyrophilic nonhistone protein. Ribosomal RNA genes ultimately direct ribosome and protein synthesis, and it has been suggested the numbers of NORs detected in the cell may reflect nuclear and cellular activity. This study was performed to evaluate the applicability of AgNORs to the diagnosis of squamous cell carcinoma of the lung. Method: The one step silver methods(AgNORs) was used to stain NORs in the routinely processed, formalin fixed, paraffin embedded sections of 36 cases of squamous cell carcinoma of the lung obtained by surgical resection of primary tumor. In each specimen, 100 tumor cells and 100 normal cells adjacent to the tumor chosen at random were examined under an oil immersion lens at a magnification of ${\times}1000$. The mean number of AgNORs per nucleus was calculated for each specimen. Results: The mean number of AgNORs per nucleus(mAgNORs) of normal bronchial epithelium and squamous cell carcinoma of the lung was $1.74{\pm}0.25$ and $4.05{\pm}0.80$, respectively. The difference of mAgNOR between normal and tumor tissue was statistically significant(p<0.001). There was no statistical difference among tumors of different stages. The difference of mAgNOR between normal and tumor tissue was statistically significant in each TNM stage(p<0.05). Conclusion: Mean AgNOR count may be used as a useful marker for the differential diagnosis of benignancy and malignancy, and proliferative activity of the cell in squamous cell carcinoma of the lung. But there was no statistical difference in mean AgNOR count among tumors of different surgical stages. Further studies for the application of mAgNORs to the diagnosis of other histologic types and cytologic specimens of the lung cancer are needed.

  • PDF

Relation of cyst counts with numbers of total nuclei of Pneumocystis carinii in rats (흰쥐 주폐포자충에 있어서 도말표본상 포낭의 수와 핵의 총 수와의 상관성)

  • Hong, Seong-Tae;Yu, Ji-Suk;Lee, Mi-Jeong
    • Parasites, Hosts and Diseases
    • /
    • v.32 no.3
    • /
    • pp.171-176
    • /
    • 1994
  • Wistar rats were induced of Pneumowstis cayinii infection by injection with methyl-prednisolone to correlate the cyst counts and numbers of nuclei. Seven sections of the lungs were examined by impression smears and also whole lung homogenates were screened for nucleus counting for each rat. At the first week of the experiment, all of the Impression smears except one were cyst negative but trophic forms were counted around 106. At the third week, the cysts appeared one per 20 Immersion oil lens fields. The nuclei were on the order of 107 at this period, and this amount of Pc is regarded as the limit of cyst detection on Impression smears. When the nuclei were over 109 in the lungs, the cysts were counted about 50 in 20 microscopic fields. The organisms were distributed in the lungs without any predilection focus. The present data suggest that the trophic forms, proliferate first and the cysts appear later in the lungs.

  • PDF