• Title/Summary/Keyword: Oil fire

Search Result 226, Processing Time 0.029 seconds

Analytical and sensitivity approaches for the sizing and placement of single DG in radial system

  • Bindumol, E.K.;Babu, C.A.
    • Advances in Energy Research
    • /
    • v.4 no.2
    • /
    • pp.163-176
    • /
    • 2016
  • Rapid depletion of fossil based oil, coal and gas reserves and its greater demand day by day necessitates the search for other alternatives. Severe environmental impacts caused by the fossil fire based power plants and the escalating fuel costs are the major challenges faced by the electricity supply industry. Integration of Distributed Generators (DG) especially, wind and solar systems to the grid has been steadily increasing due to the concern of clean environment. This paper focuses on a new simple and fast load flow algorithm named Backward Forward Sweep Algorithm (BFSA) for finding the voltage profile and power losses with the integration of various sizes of DG at different locations. Genetic Algorithm (GA) based BFSA is adopted in finding the optimal location and sizing of DG to attain an improved voltage profile and considerable reduced power loss. Simulation results show that the proposed algorithm is more efficient in finding the optimal location and sizing of DG in 15-bus radial distribution system (RDS).The authenticity of the placement of optimized DG is assured with other DG placement techniques.

Management Strategy for Soil and Groundwater Conservation (토양 및 지하수 보전을 위한 토양관리 및 대책방안)

  • 김경숙;정재춘
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.221-224
    • /
    • 1998
  • Environmental pollution is continuously increasing with the economic growth and industrial development. With this trend, soil and groundwater pollution problem has been surfaced as important social issues. Recently, Korean government promulgated the Soil Environment Conservation Act. But there are many problems to control sound soil quality management. Anthropogenic source of pollution such as waste landfill, pesticides, fertilizer, underground storage oil tanks is important as well as natural source such as acid rain and forest fire. The regulation should be expanded to include groundwater preservation as well as soil quality, because soil pollution is closely related to groundwater pollution. Therefore, legal regulations must be expanded to these facilities and take into account technical feasibility and finance.

  • PDF

A Study on the Limitation of the Action to Avoid Collision for Super Huge Vessel, Based on Result of Her Crash Astern and Turning Tests (초대형선의 충돌피항동작에 관한 고찰 -TURNING AND CRASH ASTERN TEST의 결과를 중심으로-)

  • Koo, Hong
    • Journal of the Korean Institute of Navigation
    • /
    • v.5 no.1
    • /
    • pp.25-35
    • /
    • 1981
  • Since 1960 tankers and bulk carriers have rapidly increased in size up to 500, 000 dwt. in operating as main system of transportation for the international trade at sea, and studies are doing carried out by various groups with a view to increasing the size still further. However, the service speed of these ships has remained almost constant, and steering devices of them have nearly not changed, comparing with regular size of a dry cargo ship. This creats the dituation where stopping distance and advance are proportionally longer for larger ships. In case of collision at sea, these vessels have been arised some serious casualties, such as sinking, fire and oil pollution. This paper analyzers a study for the handling of super huge vessels to avoid collision at sea, basing on the results of the crash astern test and turning test of them.

  • PDF

Basic Study on Flashover Characteristics of Power Lines by Forest Fire(I) (산불화재에 의한 전력선 섬락사고 기초연구(I))

  • Kim, C.N.;Lee, S.W.;Lee, K.S.;Kim, I.S.;Lee, D.I.;Park, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.387-390
    • /
    • 2001
  • The experiments were performed in model conductors under the application of ac and dc high-voltages. The results of an experimental investigation into the flashover characteristics of air dielectric strength in the presence of oil/gas flame are reported. It is demonstrated that flame can reduce by more than half, 80% in maximum the breakdown voltage of a model line. Taking a horizontal model line with a k=0.5, it can be seen from the results that the reduction of flashover levels, in comparison with the no-flame case, are 78.7[%] for h=0[cm], 59.6[%] for h=3[cm], 46.4[%] for h=6[cm], 40.4[%] for h=9[cm] and 23.2[%] for h=12[cm] when ac voltage is applied.

  • PDF

Optimization of Heat Exchanger Network in the Steam Assisted Gravity Drainage Process Integration

  • Rho, Seon-Gyun;Yuhang, Zhang;Hwang, InJu;Kang, Choon-Hyoung
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.260-269
    • /
    • 2020
  • The Steam Assisted Gravity Drainage (SAGD) process is an enhanced method to extract oil from bitumen which involves surface and central process facilities. This paper describes the Central Process Facilities (CPF) of SAGD and proposes several retrofit plans to the Heat Exchanger Network (HEN). In this approach, the process integration scheme is applied to estimate the energy saving in HENs, and various cases are modeled in favor of a commercial simulator. Throughout this work, a minimum approach temperature of 10℃ is assumed. The results reveal that, due to the HEN optimization using process integration, the heating and cooling duties can be reduced to 29.68MW and 1.886MW, respectively. Compared with the Husky case, all cases considered in this study indicate a potential reduction of at least 6% in total cost, including investment and operation costs.

Studies on the determination of atmospheric sulfur dioxide and elimination of sulfur in kerosene by thiobacilli (미생물에 의한 공기의 SO$_{2}$ 오염방제에 관한 연구)

  • 이배함;이병조;이정근;정성구
    • Korean Journal of Microbiology
    • /
    • v.7 no.2
    • /
    • pp.57-62
    • /
    • 1969
  • The experiments attempted to basic studies on the atmospheric dioxide in Korea and on the elimination of sulfur in oil Thiobacilli in order to control of atmospheric sulfur dioxide. The results of experiments are following as : 1) Content of atmospheric sulfur dioxide in industrial zone which used kerosene for fuel was 0.092 ppm(average) and 0.16ppm(maximum). 2) Content of sulfur dioxide at room air which used briquet for stove fire was 0.44ppm (average) adn 0.50 pp,(maximum). 3) Thirteen strains of thiobacilli were isolated from Korean soil and sewage and they were identified with T. thiooxidans (5strains), T. thioparus(3strains), T.ferrooxidans 3 man's observation and the description in Bergey's manual. 4) Two promising strains, one of T. thiooxidans and one of T. ferooxidans. were selected for elimieation of in kerosene.

  • PDF

Characterization of Pitch Derived from Petroleum Residue and Coal-tar (석유계 잔사유 및 coal-tar의 핏치 개질 특성)

  • KIM, JIHONG;KIM, HYEONGGI
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.5
    • /
    • pp.612-619
    • /
    • 2016
  • Pitch synthesis reaction was studied based on the effect for chemical composition of feedstock. Feedstock was selected as pyrolyzed fuel oil (PFO) and coal-tar (CT), which are by-products in petroleum and steel industry. Pitch was prepared at $420^{\circ}C$ for 180 minutes on atmospheric pressure by thermal treatment. Thermal stability and softening point (SP) of the prepared pitches were investigated and their molecular weight distribution was analyzed by MALDI-TOF. PFO has various aliphatic compounds and coal-tar has high aromaticity with 3 wt% of primary quinoline insolubles. The thermal property of PFO was enhanced with polymerization reaction during the thermal treatment with increased molecular weight range. But CT was inferior to PFO because of side reaction by hetero elements. CTP was appeared molecular weight by 0~200 m/z.

Study of Oil Palm Biomass Resources (Part 4) Study of Pelletization of Torrefied Oil Palm Biomass - (오일팜 바이오매스의 자원화 연구 IV - 반탄화된 오일팜 바이오매스의 펠릿 성형 특성 연구 -)

  • Sung, Yong Joo;Kim, Chul-Hwan;Lee, Ji-Young;Cho, Hu-Seung;Nam, Hye-Gyeong;Park, Hyeong-Hun;Kwon, Sol;Kim, Se-Bin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.1
    • /
    • pp.24-34
    • /
    • 2015
  • Domestic companies supplying electricity must increase obligatory duty to use renewable energy annually. If not met with obligatory allotment, the electricity-supply companies must pay RPS (Renewable Portfolio Standards) penalty. Although the power plants using a pulverizing coal firing boiler could co-fire up to around 3 per cent with wood pellets mixed in with coal feedstock without any major equipment revamps, they recorded only about 60 per cent fulfillment of RPS. Consequently, USD 46 million of RPS penalty was imposed on the six power supplying subsidiaries of GENCOs in 2014. One of the solutions to reduce the RPS penalty is that the power supply companies adopt the co-firing of torrefied lignocellulosic biomass in coal plants, which may contribute to the use of over 30 per cent of torrefied biomass mixed with bituminous coals. Extra binder was required to form pellets using torrefied biomass such as wood chips, PKS (Palm Kernel Shell) and EFB (Empty Fruit Bunch). Instead of corn starch, 30, 50 and 70 per cent of Larix saw dusts were respectively added to the torrefied feedstocks such as Pinus densiflora chips, PKS and EFB. The addition of saw dusts led to the decrease of the calorific values of the pellets but the forming ability of the pelletizer was exceedingly improved. Another advantage from the addition of saw dusts stemmed from the reduction of ash contents of the pellets. Finally, it was confirmed that torrefied oil palm biomass such as PKS and EFB could be valuable feedstocks in making pellets through improved binding ability.

A Study on the Measurement of Explosion Range by CO2 Addition for the Process Safety Operation of Propylene (프로필렌의 공정안전 운전을 위한 CO2 첨가량에 따른 폭발범위 측정에 관한 연구)

  • Choi, Yu-Jung;Heo, Jong-Man;Kim, Jung-Hun;Choi, Jae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.599-606
    • /
    • 2019
  • Most facilities that manufacture products made from the hazardous materials operate at high temperatures and pressures. Therefore, there is a risk of fire explosion. In particular, an explosion accident is a major risk factor for facilities with hazardous materials, such as oil, chemical, and gas. Propylene is often used in sites producing basic raw materials and synthetic materials by addition polymerization at petrochemical plants. To prevent an explosion in the business using propylene, the explosion range with the oxygen concentration was calculated according to the changes in temperature and pressure using an inert gas, carbon dioxide. In these measurements, the temperature was $25^{\circ}C$, $100^{\circ}C$, and $200^{\circ}C$ and the amount of carbon dioxide in the container was $1.0kgf/cm^2.G$, $1.5kgf/cm^2.G$, $2.0kgf/cm^2.G$, and $2.5kgf/cm^2.G$. The explosion limit was related to temperature, pressure, and oxygen concentration. The minimum oxygen concentration for an explosion decreased with increasing temperature and pressure. The range of explosion narrowed with decreasing oxygen concentration. In addition, no explosion occurred at concentrations below the minimum oxygen concentration, even with steam and an ignition source of propylene.

A study on the Development of Low-loss Type Mold Autotransformers (저손실형 몰드 단권변압기 개발)

  • Lee, Jong-Su;Shin, Myung-Ho;Mun, Byung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.92-94
    • /
    • 2003
  • The autotransformer currently used on the electric railway system is made of class A insulation material and uses the paper insulation method. As a power converter supplying power to the trolley wire, the autotransformer is one of critical equipment in the railway system. In the autotransformer, load irregularly changes and overload often occurs. These cause overheating of the autotransformer and facilitate deterioration of the autotransformer resulting in burnout accidents due to insulation breakdown. Also, the current autotransformer has poor insolation and short-circuit strength which often badly affect the service life of the transformer, and needs to improve its quality urgently. To overcome one of existing shortcomings of the mold transformer, manufacturers use epoxy resins that have superior flame retardancy to get rid of fro and explosion possibilities during accidents. Currently, new mold transformers are used in indoor distribution facilities with fire-fighting equipments. Coils molded in epoxy resins do not have their insulation performance compromised by humidity, dust, etc enabling easy inspection and maintenance. Comparing to the oil immersed transformer, the mold transformer does not have any concern about environmental pollutions by oil leak or replacement Therefore, to reduce breakdowns and improve reliability of the autotransformer, it is necessary to develop a new mold autotransformer with low loss suitable for our environment to suppress breakdowns of the autotransformer and improve the reliability. This study is about development of a low-loss mold autotransformer necessitated by reasons mentioned earlier.

  • PDF