• Title/Summary/Keyword: Oil fire

Search Result 226, Processing Time 0.035 seconds

A Literature Study on the External Treatment of a Burn (火傷의 外治法에 對한 文獻的 考察 (外用藥을 중심으로))

  • Yu, Mi-Kyoung;Jeong, Dong-hwan;Sim, Sang-hee;Park, Su-Yeon;Kim, Jong-han;Choi, Jung-hwa
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.16 no.3
    • /
    • pp.38-67
    • /
    • 2003
  • The burn is acute skin injury caused by fire, hot water. steam. hot oil, sour and salty. It is occurred frequently in the daily life as well as oriental therapy like moxibustion therapy, physical therapy. Nevertheless, medical treatment of the burn is almost dependent on western cure. So we chose the oriental medicine textbooks and the oriental medicine journals that were dealing with the drugs, processing the drugs. peculiar treatment put first external cure. The results were as follows; 1. The burn is acute skin injury caused by fire, hot water, steam, hot oil, sour and salty. 2. The burn cause blisters, irritability and restlessness, nausea, dryness of mouth, constipation, in case of serious, coma, dyspnea and death. The early stage of the burn, blisters form by skin damage and they burst into skin ulceration from which pus issues, the latter term, the wound form scab and healed up. 3. In a light case, medical treatment of the burn was used external treatment by medicine for externalism use, in a serious case, it was used both as an internal remedy and medicine for outward application. Also in the early stage, it was careful of using the cold and cool medicine, as the process of healing, it was used alleviating pain, detoxicating, moistening the skin, growing muscle and skin, convergence, evacuating pus, regeneration of the tissue, strengthen the spleen and nourishing the stomach. 4. The external treatment medication is Herba Ephedrae Oil(麻油), Radix ET Rhizoma Rhei(大黃), Glauberitum(寒水石), Water(水), Pig OiI(猪油), Pig Fat(猪脂), Radix Angelicae Gigantis(當歸), Rhizoma Coptidis(黃連), Cortex Phellodindri(黃栢). The White of an Egg(鷄子淸), Raw Honey(生蜜), Honey(蜜), Wine(酒), Etc. It is mostly the cold and cool medications. 5. Soft extracted and powered dosage form in external treatment is much used. The soft extracted form(32times used) are mostly Chung Ryang paste(淸凉膏) and Fructus Papaveris paste(罌粟膏). The powered form(30times used) are mostly Bingsang Powder(氷霜散), Bosaenggugo Powder(保生救苦散), Sahwang Powder(四黃散). The others is much a various powder adding solvent. 6. If varicella stage, erosion after varicella stage, oozing stage and extreme pain stage, the powder adding solvent is much used. If little oozing stage. ulcering stage, scabing stage and a chronic stage, Soft extracted dosage form is much used. 7. The most many(26.65%) used method is that apply each medication power mixed water(水), wine(酒), honey(蜜) in a wounded part.

  • PDF

Feasibility Study of Using Wood Pyrolysis Oil in a Dual-injection Diesel Engine (이중분사기가 장착된 디젤 엔진에서 목질계 열분해유의 적용 가능성에 관한 연구)

  • Lee, Seokhwan;Jang, Youngun;Kim, Hoseung;Kim, Taeyoung;Kang, Kernyong;Lim, Jonghan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 2014
  • The vast stores of biomass available in the worldwide have the potential to displace significant amounts of petroleum fuels. Fast pyrolysis of biomass is one of several paths by which we can convert biomass to higher value products. The wood pyrolysis oil (WPO) has been regarded as an alternative fuel for petroleum fuels to be used in diesel engine. However, the use of WPO in a diesel engine requires modifications due to low energy density, high water contents, high acidity, high viscosity, and low cetane number of the WPO. One possible method by which the shortcomings may be circumvented is to co-fire WPO with other petroleum fuels. WPO has poor miscibility with light petroleum fuel oils; the most suitable candidates fuels for direct fuel mixing are methanol or ethanol. Early mixing with methanol or ethanol has the added benefit of significantly improving the storage and handling properties of the WPO. For separate injection co-firing, a WPO-ethanol blended fuel can be fired through diesel pilot injection in a dual-injection dieel engine. In this study, the performance and emission characteristics of a dual-injection diesel engine fuelled with diesel (pilot injection) and WPO-ethanol blend (main injection) were experimentally investigated. Results showed that although stable engine operation was possible with separate injection co-firing, the fuel conversion efficiency was slightly decreased due to high water contents of WPO compare to diesel combustion.

A Study on Durability Test of Check Valve for CNG Vehicles (천연가스 차량용 체크밸브의 내구성능에 관한 연구)

  • Kim, Chang-Gi;Lee, Sun-Youp;Cho, Gyu-Baek
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.15-20
    • /
    • 2009
  • The number of compressed natural gas (CNG) vehicles have increased gradually by virtue of korea government's urban air quality improvement policy since 1998. Although the use of CNG as transportation fuel gives environmental benefits, there is a possibility of huge accidents from unexpected fire. Therefore, needs for the guarantee of safety are indispensible for the reliable operation of CNG vehicles. A check valve is a safety device which prevents leakage of the pressurized fuel charged in a fuel tank. Durability of this component should be guaranteed in spite of repeated operation. This research has performed durability tests of a CNG check valve regarding the repeated usage, extreme chattering, and the effect of compressor oil.Although a check valve used for CNG vehicle satisfies validation requirements in the test results, it has been found that problem in the function of leakage prevention in a check valve could take place in the case of prolonged exposure to compressor oil.

  • PDF

TRANSFORMER EXPLOSION AND FIRE PREVENTION (변압기 폭발/화재 방지 기술)

  • Kim, Hyung-Seung;Magnier, Philippe
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.93-94
    • /
    • 2007
  • An essential step for SERGI is to show the TRANSFORMER PROTECTOR (TP) efficacy for all transformers and all types of rupture of insulation. Its research program philosophy is thus to maintain a strong connection between experiments and the theoretical developments. Up to now, two TP test campaigns have been performed, both under the worst conditions by creating low impedance faults leading to electrical arcs inside the transformer tank dielectric oil. In 2002, Electricite de France performed 28 TP tests. Then, in 2004, a second campaign of 34 TP tests was carried out by CEPEL, the Brazilian independent High Voltage Laboratory. For the 62 tests, each transformer was equipped with the TP, which reacts directly to the moving dynamic pressure peak, shock wave, caused by the low impedance fault. When an electrical arc occurs, only one pressure peak is generated. The initial energy transfer is almost instantaneous, and so is the phase change. Because of the oil inertia, the gas is very quickly pressurised. As it is more difficult to vaporise a liquid than to crack oil-vapour into smaller molecules, the arc location would mainly remain in the gaseous phase after and less gas will be produced. As a result, when comparing tests for which pressure peaks are respectively equal to 8 bar (116 psi) and 8.8 bar (127 psi), the corresponding arc energies vary by an order 10 of magnitude (0.1 MJ and 1 MJ respectively). The correlation of the results obtained between arc energy and dynamic pressure demonstrates that the arc energy is not the key parameter during transformer tank explosion, which is in opposition with the common electrical engineers belief.

  • PDF

Effects of Milk Thistle Oil on Chemically Damaged Hair Improvement (밀크씨슬 오일에 의한 화학적 손상모발의 개선 효과)

  • Kim, Ju-Sub;Jeon, Yong-Han
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.2
    • /
    • pp.434-440
    • /
    • 2021
  • This study aimed to understand the effects on the improvement of hair texture by producing a hair texture improvement agent with milk thistle oil, and then applying it to the damaged hair. Each sample before and after application was measured. To understand the effects on the improvement of hair texture, the tensile strength, absorbance with the use of methylene blue, and gloss were measured. In the results of measuring the tensile strength to understand the effects on the improvement of hair texture, In the results of analyzing the absorbance with the use of methylene blue, the value after application was decreased than the value before application. In the results of measuring the gloss, none of the samples showed huge differences. In the results of this study, the milk thistle oil showed the effects on the texture improvement of damaged hair.

Analysis of DC insulation and properties of epoxy/ceramic composites with nanosized ZnO/TiO2 fillers

  • Kwon, Jung-Hun;Kim, Yu-Min;Kang, Seong-Hwa;Kim, Pyung-Jung;Jung, Jong-Hoon;Lim, Kee-Joe
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.332-335
    • /
    • 2012
  • A molded transformer is maintenance-free, which makes it unnecessary to replace the insulating material, like in an oil-filled transformer, because the epoxy, which is a molded insulating resin, does not suffer variations in its insulating performance for heat cycles over a long time, as compared to insulating oil. In spite of these advantages, a molded transformer may still be accessed by the user, which is not good in regards to reliability or noise compared to the oil transformers. In particular, a distrust exists regarding reliability due to the long-term insulating performance. These properties have been studied in regards to the improvement of epoxy composites and molded transformer insulation. There have nevertheless been insufficient investigations into the insulation properties of epoxy composites. In this study, it is a researching of the epoxy for insulating material. In order to prepare the specimens, a main resin, a hardener, an accelerator, and a nano/micro filler were used. Varying amounts of TiO2 and ZnO nano fillers were added to the epoxy mixture along with a fixed amount of micro silica. This paper presents the DC insulation breakdown test, thermal expansion coefficient, and thermal conductivity results for the manufactured specimens. From these results, it has been found that the insulating performance of nano/micro epoxy composites is improved as compared to plain molded transformer insulation, and that nano/micro epoxy composites contribute to the reliability and compactness of molded transformers.

A Paper on the Relation of Ship Management and Obligation to Exercise Due Diligence in Making the Vessel Seaworthy (선박관리와 감항능력주의의무에 관한 연구)

  • Jeong, Jun-Sik
    • Journal of Korea Port Economic Association
    • /
    • v.21 no.4
    • /
    • pp.121-139
    • /
    • 2005
  • The case, Papera Traders Co. Ltd. and Others v. Hyundai Merchant Marine Co. Ltd and Another(The Eurasian Dream), was occurred on July, 1998 when the ISM Code became mandatory under SOLAS and from that date it applied to oil tankers, chemical tankers, gas carriers, bulk carriers and cargo high-speed craft of 500 gross tonnage and above. On July 23, 1998, a fire started on the deck of pure car carrier Eurasian Dream while in port at Sharjah. The source of fuel was the stevedores action of pouring petrol or transferring fuel in some way - refueling or pouring into a carburettor. The fire eventually destroyed or damaged the vessels cargo of new and second-hand vehicles and rendered the vessel itself a constructive total loss. Justice Cresswell held that the fire that destroyed or damaged the cargo was due to the unseaworthiness of the vessel they have the burden of proving that the vessel was unseaworthy before and at the beginning of the voyage and that the loss or damage was caused by that unseaworthiness. This case was a dispute between dependent and claimant alleging that the carrier should provide "properly man, equip and supply the ship and keep the ship so manned" under Hague-Visby Rules. Although ISM code was not officially applied to the carriage by car carriers until July 2002, a rule based on the code had customarily been employed as a mean for international dispute resolution. Examining the above case closely, the purpose of this study is to explore the relation of ship management and obligation to exercise due diligence in making the vessel seaworthy.

  • PDF

A Study on the Actual Status of Heat Transfer oils in Industries for Process Safety Management (공정안전관리 사업장의 열매체유 사용실태에 관한 연구)

  • Lee, Keun Won;Lee, Joo Yeob
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.33-39
    • /
    • 2014
  • Heat transfer oils are used in applications such as chemical plant heating systems, refinery heat exchange systems, certain gas processes, injection molding systems, and pulp and paper processing. These oils are extremely stable and resistant to thermal and oxidative degradation. In the event of a spill or accidental release of heat transfer oils, it can be ignited easily when there is an ignition source. This study discusses the status of safety management through the actual status of the heat transfer oils to prevent fire and explosion accidents in industries for process safety management. The actual status of the heat transfer oils in process system of industries surveyed by a questionnaire developed. The results of this study can be used to help establishment of safety management to prevent fire and explosion accidents, such as the management of heat transfer oils, safe operation and maintenance in heat transfer oil processes.

A Study on the Improvement of National Marine Pollution Response Policy based on the Analysis of Gulf of Mexico Oil Spill Incident (미국 멕시코만 오염사고 분석을 통한 국가방제정책 개선방안 연구)

  • Kim, Sang-Woon;Lim, Chang-Soo;Lee, Wan-Sub;Ha, Chang-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.3
    • /
    • pp.257-264
    • /
    • 2011
  • On April 20, 2010, semi-submersible offshore drilling unit Deepwater Horizon was exploded and sank, and 4.9 million barrels(about 778 thousand tons) of crude oil was spilled into the Gulf of Mexico. As more than one year has been passed since the incident, a lot of investigation reports and lessons learned have been made public and also a lot more will be released soon. This paper studies the final report of the National Commission on "the BP Deepwater Horizon Oil Spill and Offshore Drilling", which was organized by the executive directive of U.S. President Barack Obama, and the interim report of Joint Investigation team of U.S. Coast Guard and BOEMRE of "Report of Investigation into the Circumstances Surrounding the Explosion, Fire, Sinking and Loss of Eleven Members Aboard the Mobile Offshore Drilling Unit Deepwater Horizon". The review is focused on the response to the oil spill. And the paper suggests how to improve national marine pollution response policy. In the paper, the Korean governments is suggested to reinforce the capability for instructing and supervising the responsible party's source control measures, to review how to introduce in-situ burning and vessel of opportunity program into our country, and to continue monitoring on the progress of developments of R&D projects related to oil spill response in the U.S..

Analysis of New & Renewable Energy Application and Energy Consumption in Public Buildings (공공건축물의 신재생에너지 적용과 에너지 사용량 분석)

  • Lee, Yong-Ho;Seo, Sang-Hyun;Kim, Hyung-Jin;Cho, Young-Hum;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.153-161
    • /
    • 2012
  • This study conducted a survey and field investigation on the application of the Public Obligation System for new & renewable energy in public buildings, as well as energy consumption of each building according to their uses. The findings are as follows: (1) Since the introduction of the Public Obligation System (until June 30, 2011), there was average 1.4 new & renewable energy facilities established at 1,433 places. Preference for solar energy facilities was the highest at 57.8%. (2) The revised act sets the obligatory supply percentage of new & renewable energy for each public building: it is 9.0% for a tax office, 4.2% for a dong office, 8.2% for a public health center, and 12.6% for a fire station. All the public buildings except for fire stations failed to meet 10% expected energy consumption, a revised standard. (3) Energy consumption of each public building was 120.6TOE for a tax office, 124.3TOE for a dong office, 166.4TOE for a public health center, and 174.6TOE for a fire station. The energy consumption was comprised of 80% electric power, 18% urban gas, and 1% oil. (4) Electric power consumption per person in the room was high at a dong office, and fuel consumption per person in the room was high at a public health center. In addition, electric power consumption per unit space was high at a public health center, and fuel consumption per unit space was high at a fire station. (5) In all the four public buildings, power load had the highest basic unit percentage at average 55%, being followed by heating load (21.2%), cooling load (15%), and water heating load (7%). A tax office and fire station had 2% load due to cooking facilities.