• 제목/요약/키워드: Oil Pump

검색결과 378건 처리시간 0.023초

지로터(2개의 타원 조합) 형상 및 포트 설계를 통한 오일펌프 성능인자 향상 (Performance Improvement of Oil Pump by Design of Gerotor (Combined Profile - Two Ellipses) and Port)

  • 곽효서;이승환;김철
    • 한국정밀공학회지
    • /
    • 제33권3호
    • /
    • pp.207-216
    • /
    • 2016
  • A gerotor is suitable for miniature manufacturing because it has high discharge per 1 cycle and a simple structure, while also being widely used for lubrication oil of engines and as a hydraulic source of automatic transmission. In the automobile industry, improvements in fuel efficiency and noise reduction have recently come to the fore. It has also been necessary to continuously improve the flow rate and noise of internal gear pumps for better fuel efficiency through optimal gerotor and port shape design. In this study, to develop an optimal gerotor with a new lobe shape, 2-ellipses-combined, the equation of the lobe shape was derived, and CFD analysis results were compared for 2-ellipses with those of the previous gerotors (3-ellipses and ellipse1-involuteellipse2). A performance test for the oil pump with the optimal rotor (2-ellipses) was carried out and showed good agreement with the results obtained from CFD analysis.

연비개선 및 소음저감을 위한 지로터 최적설계 (타원 1-타원형 인벌루트-타원2) (Optimal Design of Gerotor (Ellipse1-Elliptical Involute-Ellipse2 Combined Lobe Shape) for Improving Fuel Efficiency and Reducing Noise)

  • 곽효서;이승환;김철
    • 한국정밀공학회지
    • /
    • 제33권11호
    • /
    • pp.927-935
    • /
    • 2016
  • A gerotor is suitable for miniature manufacturing because it has a high discharge per cycle and a simple structure, while also being widely used as lubrication oil of engines and the hydraulic source of automatic transmission. In the automobile industry, it has been necessary to continuously improve the flow rate and noise of internal gear pumps for better fuel efficiency through optimal gerotor design. In this study, to obtain an optimal gerotor with an ellipse-elliptical involute-ellipse combined lobe shape, an automatic program was developed for calculating performance parameters and drawing a gerotor profile. An oil pump was assembled with the optimal gerotor together with the port used at the actual field and CFD analysis was performed on this assembly using Ansys-CFX. A performance test for the oil pump was carried out and showed good agreement with the results obtained from the theoretical analysis and the CFD analysis.

수직형 저널 베어링에서 preload 변화에 따른 베어링 패드 온도 변화 (Bearing Pad Temperature Change Depending on the Preload of Vertical Journal Guide Bearing)

  • 김준성;김두영;김동관;박상호
    • 한국유체기계학회 논문집
    • /
    • 제12권6호
    • /
    • pp.33-40
    • /
    • 2009
  • The temperature of vertical pump bearing metal in the pumped storage power plant has been high enough to shutdown the unit. Attempts such as decreasing the oil supply temperature, increasing the bearing oil gap etc. were performed to resolve the problem, but the issue was not resolved. Finally, the high bearing metal temperature was corrected by adjusting the bearing preload. The preload is formed by the oil wedge between the journal surface and bearing pad surface and the degree of preload is determined by the machined radial clearance, assembled radial clearance, rotor journal diameter etc. This paper focuses on the analysis of the preload depending on the bearing parameters and the result of the modification of the bearing following the analysis. The bearing metal temperature dropped as much as $20^{\circ}C$ which was similar as expected by software calculation. But the shaft vibration could increase when the assembled radial clearance is excessive. So, the adjustment of the bearing preload for the tilting pad type journal bearing should be carefully performed.

자동차용 연료펌프의 진동 저감에 대한 연구 (A Study on the Vibration Reduction of an Automobile Fuel Pump)

  • 김병진;원홍인;이성원;박상준;정진태
    • 한국소음진동공학회논문집
    • /
    • 제23권6호
    • /
    • pp.520-526
    • /
    • 2013
  • This article presents the reduction of vibration generated by an automobile fuel pump. In order to analyze the vibration of the fuel pump, a simplified dynamic model is established, which is composed of a rigid rotor and a equivalent springs. The equivalent stiffnesses of the upper and lower assemblies are evaluated by the comparison of modal testing results and the finite element analysis. The stiffness for the oil film of the journal bearing is extracted by using Reynold's equation. In addition, the time responses for the vibration of the fuel pump are computed by using a commercial multi-body dynamics software, RecurDyn. Based on these results, some design suggestions are proposed to reduce the vibration of an automobile fuel pump.

시설원예용 대온도차 지열원 히트펌프 운전비용 효과 분석 (Operating Cost Analysis of a High Temperature Ground Source Heat Pump System for a Greenhouse)

  • 강신형;박승병;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권1호
    • /
    • pp.17-22
    • /
    • 2016
  • It is very important to obtain a out-of season production in horticultural greenhouses corresponding with higher crop prices. A ground source heat pump system has been highly spotlighed as an energy efficient heating system for the greenhouse. This paper investigated the operating cost of the ground source heat pump system with the variation of generating temperature and designing methods for heating system of the greenhouse. Even though the COP of the ground source heat pump system decreased with an increment of generating temperature in heating mode, the operating cost could be reduced. By adopting the high temperature heat pump system and heat storage tank, it could be achieved to save energy and reduce the operating time of auxiliary oil heating system for producing good plant-growth in the greenhouse.

태양열이용 하이브리드 난방 열펌프시스템 (The hybrid heat pump with solar energy for heating)

  • 김지영;고광수;강병찬;박윤철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.173-178
    • /
    • 2005
  • Recently. we interested in renewable energy due to cost increase of the crude oil, etc. In this study solar assisted hybrid heat pump system that uses the solar heat and air as heat source analyzed by experimentally.'rho system could runs at dual mode. One is thermal storage mode of solar energy at day time and the other is heat pump mode with low temperature air as heat source at night time. In case of setting temperature over the limited range. high temperature water heated at the solar energy collecting tubes supplied to the storage tank. As results. it is founded that the heat pump performance Is higher than general heat pump which using the only air as a heat source. The developed system could be used as main healing equipment for the panel heating for the residential house.

  • PDF

지역난방용 2단 압축 히트펌프 시스템 성능평가 (Performance Evaluation of a Two-Stage Compression Heat Pump System for District Heating)

  • 박차식;차동안;권오경
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.585-590
    • /
    • 2012
  • The objective of this study is to investigate the performance of a two-stage compression heat pump system for district heating. The experimental setup of heat pump consists of compressor, condenser, evaporator, expansion device, intercooler, flash tank, oil separator and accumulator. The experimental evaluations on the two-stage compression cycle were carried out under various operating conditions which were heat source temperature, the degree of compressor inlet superheat, and intermediate pressure. The temperature ranges of unutilized energy as the heat source were used in the test conditions. As the heat source temperature increased from $10^{\circ}C$ to $30^{\circ}C$, the COP and heating capacity of the heat pump system increased by 22.6% and 45.8%, respectively. The performance of the two-stage heat pump system increased by 5.2% with the variation of the intermediate pressure in the same heat source temperature conditions.

동특성 시뮬레이션을 이용한 공기, 지열 및 지하 저수조 열원 소형 열펌프의 경제성 분석 (Economical Analysis of a Small Capacity Heat Pump utilizing Heat Sources of Air, Geothermal and Underground Water Tank using Dynamic Simulation)

  • 양철호;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권4호
    • /
    • pp.17-23
    • /
    • 2012
  • Due to reinforcement of international environment regulation and high oil prices, interest in renewable energy is growing. Countries participating in UNFCCC are continuously putting efforts in reducing greenhouse gas after enforcing Kyoto Protocol into effect on Feb, 2005. Energy used in buildings, which relies heavily on fossil fuel accounts for about 24% of total energy consumption. In this study, air, geothermal and water source heat pump systems for an 322 $m^2$ auditorium in an office building is simulated using TRNSYS version 17 for comparing energy consumptions. The results show that energy consumptions of air, geothermal and water source heat pumps are 14,485, 10,249, and 10,405 kWh, respectively. Annual equal payments which consider both initial and running costs become 5,734,521, 6,403,257 and 5,596,058 Won. Thus, water source heat pump is the best economical choice.

가상 설계 환경을 활용한 지로터 펌프의 배제용적 증량 설계 사례 (Design for Increasing Displacement Volume of Gerotor Pumps using Virtual Design Environment)

  • 노대경;이동원;전정배;장주섭
    • 드라이브 ㆍ 컨트롤
    • /
    • 제21권2호
    • /
    • pp.15-22
    • /
    • 2024
  • The objective of this study was to examine whether a gerotor pump used in a transmission could be converted into an electric vehicle thermal management system pump using a virtual design environment. To achieve this objective, we first built an environment that could analyze the performance of a gerotor pump in heat transfer fluid. Flow rate, pressure, and volumetric efficiency were then analyzed when using heat transfer fluid in a gerotor pump. Finally, how large the displacement volume of the pump should be designed when using a heat transfer fluid other than oil was determined. Based on results of this study, it is expected that gerotor pumps will be applied to new business fields such as electric vehicle cooling systems.