• Title/Summary/Keyword: Oil Flow Visualization

Search Result 79, Processing Time 0.024 seconds

Visualization of Flow inside the Side Channel Type Regenerative Blower (사이드 채널형 재생블로워의 내부 유동 가시화)

  • Yang, Hyeonmo;Lee, Kyoung-Yong;Choi, Youngseok;Jeong, Kyungseok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.5
    • /
    • pp.24-28
    • /
    • 2013
  • Visualization of internal flow of a regenerative blower has been made by injecting a tracer directly into the flow. For the convenience of visualization, working fluid has been replaced by water and marbling color oil has been used as a tracer. Oil droplet has been injected near the inlet of the blower and the streak has been recorded using a high speed camera with the illumination of high power light sources. At first, droplets have irregular motion in the near inlet area and enter into a groove of the impeller. Then the droplets circulate inside the groove while translated by the rotational motion of the impeller. When the droplets get out of the impeller groove, their speed is lower than that of impeller. And the droplets repeatedly enter into the groove and circulate inside the grooves. Then the droplets either flow to the outlet or reenter into the inlet area through stripper. Through this experimental study, internally circulating motion of the flow inside a regenerative blower has been characterized.

A Study on the Oil/Water Separation Efficiency of Laminated Plate Type Oily water Separator with Inclined Angle (경사각을 갖는 적층판식 유수분리기의 유수분리 효율에 관한 연구)

  • 한원희;김준효;최민선
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.365-374
    • /
    • 2001
  • Its a tendency to strengthen related international was as the importance on marine oil pollution recently becomes the issue. According to the regulation of IMO, oil discharge from ships is allowed under 15PPM only and oil filtering equipment is essential. Oily water separator of laminated plate type which is one of gravity type separator can be use as assistant equipment for the oil filtering system to meet the present IMO standard, because it fits well to process large amount of rich oil with high specific gravity. The purpose of this paper is to investigate an efficiency of oil/water separation with the characteristics of laminated plate arrangement. The analyse of oil contents for oil-water mixture were carried out in order to find an efficiency of oil/water separation and an experimental study was simultaneously carried out to investigate internal flow characteristics of separator by visualization method and PIV(Particle Image Velocimetry) measurement at three spaces of plates for 5, 10 and 15 mm with variation of inlet flow rates of $0.25m^3$/h and $0.5m^3$/h. The experimental results showed that the space of the plates acts a significant role in the separating process.

  • PDF

A Study on the Flow Characteristics for the Plate Chamber in Type of Oily Parallel Plate Water Separator (평행판식 유수분리기에서 분리판실의 유동특성에 관한 연구)

  • Kim, J.H.;Han, W.H.
    • Journal of Power System Engineering
    • /
    • v.5 no.1
    • /
    • pp.64-72
    • /
    • 2001
  • According to the regulation of IMO, oil discharge from ships is allowed under 15ppm only and an oil filtering equipment is essential. However, for large ships using heavy fuel oil of over S.G 0.98 and viscosity 380cSt and system oil, it has been in difficulty to process with existing filtering type of oily water separator. A parallel plate type oily water separator which is one of gravity type separators can be used as an assistant equipment for the oil filtering system to meet the present IMO standard of 15 ppm, because it is an efficient method in dealing with a large amount of rich oil with high specific gravity. This work is focused on the fundamental investigation of the performance of the plate type oily water separator by visualization method and PIV(Particle Image Velocimetry) measurement to acquire multi-point velocity data simultaneously. The experimental results showed that the space of the plates acts a significant role in separating process and it was found that an important point to minimize a vortex flow is to flow a large amount of fluid in space of the plates in order to promote the efficiency of separation.

  • PDF

Visualization of Oil Behavior in Piston Land Region (피스톤 랜드 부에서 오일거동의 가시화)

  • 민병순
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.5
    • /
    • pp.105-113
    • /
    • 2000
  • In order to clarify the final process of oil consumption, the distribution and flow of oil through each ring were visualized by induced fluorescence method. Motoring and firing test were performed in a single cylinder research engine with transparent cylinder liner. The appropriate calibration techniques were used to solve the unstability of induced light intensity as well as to know the relation of the oil film thickness and output signal. Oil behavior was also observed at dynamic state by high speed CCD camera. By analyzing the oil film thickness converted from the photographed image, it was observed that the main route of oil transport through each ring is the end gap under the usual operating condition, low engine speed and low load condition. Oil film thickness is observed to be irregular and tend to move in a body horizontally at a given piston land. And it is also found that oil flows through oil ring gap so quickly that it can be observed in a single cycle, but it flows so slowly through top and 2nd compression rings that it takes quite a long time to detect the flow.

  • PDF

Analysis of Oil Behavior inside Upper Part of Rotary Compressor Using Visualization Technique (가시화 기법을 이용한 로터리 압축기 상부의 오일 거동 분석)

  • Cho Pil-Jae;Lee Seung-Kap;Youn Young;Ko Han Seo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.772-779
    • /
    • 2005
  • An efficiency of a refrigeration cycle and a reliability of a compressor can be reduced if a refrigerant including excessive lubricating oil is exhausted from the compressor. Thus, the analysis of the oil behavior inside the compressor is required to prevent the problem. A tested rotary compressor with visualization windows has been manufactured in this study to investigate the oil behavior using developed visualization techniques. The oil behaviors at various operating conditions have been quantified to obtain the relationship with the outlet pressure inside the compressor. Also, the effect of the operating conditions on the quantity of the exhausted oil from the rotary compressor has been investigated using a manufactured test model.

A Study on Ventilation Characteristics of Cargo-oil pump room (화물유 펌프실의 환기특성에 관한 연구)

  • 박찬수;조대환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.134-141
    • /
    • 2000
  • In this study, a scaled model chamber was built to investigate ventilation characteristics of the Under floor Air-conditioning System. Experimental study was performed in model for cargo-oil pump room with inlet and outlet by visualization equipment with laser apparatus. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system(CACTUS'2000) which adopted two-frame grey-level cross correlation algorithm. The flow pattern reveals the large scale counterclockwise forced-vortex rotation from upside louver to lower scupper toward diagonal corner and also found small eddies at bottom layer

  • PDF

Study on Performance Evaluation of Marine Kitchen Ventilation Hood (선박용 주방 환기후드의 성능평가에 관한 연구)

  • Kim, Dong-Gyu;Chung, Yong-Hyun;Kum, Jong-Soo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.6
    • /
    • pp.1373-1379
    • /
    • 2014
  • The purpose of this research is to evaluate the performance of the Ventilation hood and to make better oil collection for improvement. In order to complete the purpose, the research range has limited a kitchen cooking utensil used in preparing food in vessels. Assessment was carried out with reference(ASTM F1704-09) to the specification. Evaluation items of ventilation hood were flow visualization, oil collection rate and noise levels. When filter angle was 40 degrees, oil collection rate was increased by 9%.

An Experimental Investigation of Swirl Angle in a Horizontal Round Tube by Flow Visualization Method

  • Tae-Hyun Chang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.879-888
    • /
    • 2003
  • Swirling air flow in a horizontal round tube was experimentally studied for its visualization. The present investigation deals with swirl angle, flow visualization studies and accompanying vortex core behavior by using oil smoke and a hot wire anemometer for Re = 40,000 and 50000 at X/D = 41, 59 and 71. In the swirl air flow, a vortex core was formed at high swirl intensity along the test tube. The swirl angle and the vortex core depended on the swirl intensity along the test tube. The results of swirl angles measured by flow visualization and hot wire reasonably agree with those of previous studies.

An Experimental Study on Flow Angle with Swirl in a Horizontal Circular Tube (수평 원통 관에서 선회를 동반한 유동각에 대한 실험적 연구)

  • Chang, Tae-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.2 no.4
    • /
    • pp.82-87
    • /
    • 2003
  • Flow angle with Swirl in a horizontal circular tube and a cylindrical annuli were experimentally studied for its visualization. This present investigation deals with flow angle, flow visualization studies and vortex core by using oil smoke and a hot wire anemometer for Re = 40,000 and 50000 at X/D = 41, 59 and 71 in a horizontal circular tube. In the swirl air flow, a vortex core was formed at high swirl intensity along the test tube. The flow angle and the vortex core depended on the swirl intensity along the test tube. The results of flow angles with swirl measured by flow visualization and hot wire reasonably agree with those of Sparrow One of the primary objectives of this research was to measure the flow angle with swirl in a cylindrical annuli along the test tube for different Reynolds numbers. The Reynolds number for these measurements ranged from 60,000 to 100,000 with L/D = a to 4.

  • PDF

Temperature Distribution of an Air-Cooled PCB Mounted with Finned and Finnless Modules (휜이 부착된 강제 공랭 모듈을 실장한 기판의 온도분포에 관한 연구)

  • Shin, D.J.;Park, S.H.;Lee, I.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.624-629
    • /
    • 2001
  • An experimental study was performed to investigate adiabatic wall temperature and heat transfer coefficient around on a module with longitudinal fin heat sink cooled by forced air flow. In the first method, inlet air flow(1-7m/s) and input power(3-5W) was varied after a heated module were placed on an adiabatic floor($320{\times}550{\times}1mm^{3}$). An adiabatic wall temperature was determinated to use liquid crystal film(LCF). In the second method to determinate heat transfer coefficient, inlet air flow(1-7m/s) and the heat flux of rubber heater($0.031-0.062\;W/cm^{2}$) was varied after an adiabatic module was placed on rubber heater covering up an adiabatic floor. In addition, surface oil-film visualization were performed to characterize the macroscopic flow-field around a module.

  • PDF