• Title/Summary/Keyword: Oh-Ji-Sang-Seung Therapy

Search Result 14, Processing Time 0.027 seconds

Isolation of Melanin Biosynthesis Inhibitory Compounds from the Phellodendri Cortex (황백(黃柏)으로부터 멜라닌 생합성 억제 물질의 분리)

  • Lee, Jong-Gu;Choi, Ji-Young;Oh, Joon-Seok;Jung, Hee-Wook;Choi, Eun-Hyang;Lee, Hee-Sang;Kim, Jeong-Ah;Chang, Tae-Soo;Son, Jong-Keun;Lee, Seung-Ho
    • Korean Journal of Pharmacognosy
    • /
    • v.38 no.4
    • /
    • pp.387-393
    • /
    • 2007
  • By screening inhibitory activities on the melanin polymer biosynthesis in B-16 mouse melanoma cell lines, MeOH extract of Phellodendri Cortex was found to have inhibitory effect on melanin polymer biosynthesis. Twelve compounds were isolated from the MeOH extract of P. Cortex. They were identified as obacunone (1), limonin (2), ${\beta}-sitosterol$ (3), bis(2-methylheptyl) phthalate (4), cycloeucalenol (5), berberine (6), palmatine (7), jatrorrhizine (8), syringin (9), umbelliferone (10), rutaecarpine (11) and scopoletin (12) by comparison of their physical and spectral data with those of authentic samples. Among the isolated compounds, berberine (6) and palmatine (7) showed potent inhibitory effect on the melanin polymer biosynthesis in cultured B-16 mouse melanoma cell lines, with Inhibition rate of 96% and 90%, respectively. As a positive control, arbutin exhibited an inhibition rate of 56%.

Outcome of Inhaler Withdrawal in Patients Receiving Triple Therapy for COPD

  • Kim, Sae Ahm;Lee, Ji-Hyun;Kim, Eun-Kyung;Kim, Tae-Hyung;Kim, Woo Jin;Lee, Jin Hwa;Yoon, Ho Il;Baek, Seunghee;Lee, Jae Seung;Oh, Yeon-Mok;Lee, Sang-Do
    • Tuberculosis and Respiratory Diseases
    • /
    • v.79 no.1
    • /
    • pp.22-30
    • /
    • 2016
  • Background: The purpose of this study was to document outcomes following withdrawal of a single inhaler (step-down) in chronic obstructive pulmonary disease (COPD) patients on triple therapy (long-acting muscarinic antagonist and a combination of long-acting ${\beta}2$-agonists and inhaled corticosteroid), which a common treatment strategy in clinical practice. Methods: Through a retrospective observational study, COPD patients receiving triple therapy over 2 years (triple group; n=109) were compared with those who had undergone triple therapy for at least 1 year and subsequently, over 9 months, initiated inhaler withdrawal (step-down group, n=39). The index time was defined as the time of withdrawal in the step-down group and as 1 year after the start of triple therapy in the triple group. Results: Lung function at the index time was superior and the previous exacerbation frequency was lower in the step-down group than in the triple group. Step-down resulted in aggravating disease symptoms, a reduced overall quality of life, decreasing exercise performance, and accelerated forced expiratory volume in 1 second ($FEV_1$) decline ($54.7{\pm}15.7mL/yr$ vs. $10.7{\pm}7.1mL/yr$, p=0.007), but there was no observed increase in the frequency of exacerbations. Conclusion: Withdrawal of a single inhaler during triple therapy in COPD patients should be conducted with caution as it may impair the exercise capacity and quality of life while accelerating $FEV_1$ decline.

The first private-hospital based proton therapy center in Korea; status of the Proton Therapy Center at Samsung Medical Center

  • Chung, Kwangzoo;Han, Youngyih;Kim, Jinsung;Ahn, Sung Hwan;Ju, Sang Gyu;Jung, Sang Hoon;Chung, Yoonsun;Cho, Sungkoo;Jo, Kwanghyun;Shin, Eun Hyuk;Hong, Chae-Seon;Shin, Jung Suk;Park, Seyjoon;Kim, Dae-Hyun;Kim, Hye Young;Lee, Boram;Shibagaki, Gantaro;Nonaka, Hideki;Sasai, Kenzo;Koyabu, Yukio;Choi, Changhoon;Huh, Seung Jae;Ahn, Yong Chan;Pyo, Hong Ryull;Lim, Do Hoon;Park, Hee Chul;Park, Won;Oh, Dong Ryul;Noh, Jae Myung;Yu, Jeong Il;Song, Sanghyuk;Lee, Ji Eun;Lee, Bomi;Choi, Doo Ho
    • Radiation Oncology Journal
    • /
    • v.33 no.4
    • /
    • pp.337-343
    • /
    • 2015
  • Purpose: The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS. Materials and Methods: The SMC-PTS has a cyclotron (230 MeV) and two treatment rooms: one treatment room is equipped with a multi-purpose nozzle and the other treatment room is equipped with a dedicated pencil beam scanning nozzle. The proton beam generator including the cyclotron and the energy selection system can lower the energy of protons down to 70 MeV from the maximum 230 MeV. Results: The multi-purpose nozzle can deliver both wobbling proton beam and active scanning proton beam, and a multi-leaf collimator has been installed in the downstream of the nozzle. The dedicated scanning nozzle can deliver active scanning proton beam with a helium gas filled pipe minimizing unnecessary interactions with the air in the beam path. The equipment was provided by Sumitomo Heavy Industries Ltd., RayStation from RaySearch Laboratories AB is the selected treatment planning system, and data management will be handled by the MOSAIQ system from Elekta AB. Conclusion: The SMC-PTS located in Seoul, Korea, is scheduled to begin treating cancer patients in 2015.

Feasibility Study of Vertical Multileaf Collimator for Determination of Irradiation Size (수직형 다엽 콜리메이터의 방사선 조사면 크기 결정을 통한 유용성 연구)

  • Lee, Chang-Yeol;Son, Ki-Hong;Shin, Sang-Hun;Park, Seung-Woo;Lee, Dong-Han;Jung, Hai-Jo;Choi, Mun-Sik;Oh, Won-Young;Kim, Kum-Bae;Yang, Gwang-Mo;Ji, Young-Hoon
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.3-11
    • /
    • 2011
  • The purpose of this study was to evaluate feasibility of Vertical Multileaf Collimator for determination of irradiation size using Vertical Multileaf Collimator and lead block to determine 4 different irradiation shape in case of Co-60 gamma-ray and 6 MV X-ray. We chose ion chamber, glass dosimeter and EBT chromic film to compare with Vertical Multileaf Collimator results and lead block results. In case of Co-60 gamma-ray and 6 MV X-ray, the central axis point dose normalized at reference field of lead block with ion chamber results for Vertical Multileaf Collimator were estimated higher than lead block about 5.1%, 4.2%. In case of Co-60 gamma-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 2.2%, 7.8%, 7.2%, 4.0% for reference, circle, triangle, cross field, respectively. In case of 6 MV X-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 6.7%, 6.2%, 3.8%, 6.2% for reference, circle, triangle, cross field, respectively. The results of EBT chromic film, Vertical Multileaf Collimator of penumbra size for all irradiation shape was smaller than lead block of those size that 2.0~3.5 mm for Co-60 gamma-ray, 0.5~1.0 mm for 6 MV X-ray. The results from this study, radiation treatment volume that results in shielding block can be minimized. In addition, during radiation treatment for 2, 3-dimensional radiation therapy using a Vertical Multileaf Collimator of this survey can be used to determine variety of irradiation fields.