Comparison Research between Lighting Based on luminance and Illuminance through Measuring Tunnel Lighting (터널조명 측정을 통한 조도와 휘도기반의 조명 비교 연구)

  • Lee, Mi-Ae;Han, Seung-Hun;Kim, Yeon-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.14-19
    • /
    • 2013
  • Tunnel lighting design and operation are both regulated based on luminance in and out of Korea these days. However, domestic tunnel lighting is operated by internal lighting depending on external brightness by using an illuminometer applying the conversion factor on luminance. The purpose of tunnel lighting is to alleviate the visual shock occurring from the rapid change from external brightness to internal brightness when entering a tunnel. However, when looking at the tunnels operated based on an illuminometer, it is not a system where the driver can measure the brightness within his or her viewing angle when entering the tunnel. It is general to install and operate the illuminometer on the roof of an administrative office near the tunnel; however, this method is not structured to connect with the internal lighting by checking the brightness of the viewing scope of the driver, thus is not structured to properly apply the viewing conditions of the driver. Rather, it should be in a method for extracting the luminance value within the viewing scope of the driver pursuant to tunnel lighting standards and in connection with internal lighting. This research seeks to find the difference between operations based on luminance and operations based on intensity of Illuminance in road tunnels through field measuring, and to suggest the necessity of operating based on luminance with the resulting value.

Trends of Daylight Environment for Office Spaces Based on Smart-Window Installation Settings (스마트 윈도우 설치 속성에 따른 사무공간의 주광 환경 추이)

  • Jae-Hyang Kim;Seung-Hoon Han
    • New & Renewable Energy
    • /
    • v.19 no.3
    • /
    • pp.13-21
    • /
    • 2023
  • Smart windows are capable of varying their visible light transmittance (VLT) in response to changing environmental conditions. The VLT variability of architectural windows is highly valuable because it enables indoor lighting and energy environments to align with external changes. However, challenges such as high installation costs and assurance of glass visibility have prompted the exploration of alternative solutions, including models incorporating partially applied smart windows., Prior research focused on useful daylight illuminance (UDI) analysis for south-facing office buildings, pointing out suitable areas for smart-window implementation to enhance lighting control. In this study, we broadened this scope by determining optimal smart-window application zones under changing building orientation. Furthermore, we studied the correlation between building orientation and smart-window deployment areas.

An Analysis of the Trend on the Interior Lighting Design of High-rise Office Buildings in Korea (국내 초고층 오피스 건축물의 조명설계 경향 분석)

  • Jeong, Keun-Young;Hong, Seong-Kwan;Choi, An-Seop;Lee, Jeong-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.157-160
    • /
    • 2007
  • Recently, may high-rise buildings have been constructed, and will be constructed so that concerns about high-rise buildings have increased. We need to develop energy saving techniques immediately because the high-rise buildings consume a lot of energy. The most of effective energy saving method is the application of the efficient lighting designs and fixtures. The purpose of this study is to analyze the trend of lighting design, fixture and control system in Korea and it can be used the lighting application guide-line for the high-rise buildings.

  • PDF

A Facial Expression Recognition Method Using Two-Stream Convolutional Networks in Natural Scenes

  • Zhao, Lixin
    • Journal of Information Processing Systems
    • /
    • v.17 no.2
    • /
    • pp.399-410
    • /
    • 2021
  • Aiming at the problem that complex external variables in natural scenes have a greater impact on facial expression recognition results, a facial expression recognition method based on two-stream convolutional neural network is proposed. The model introduces exponentially enhanced shared input weights before each level of convolution input, and uses soft attention mechanism modules on the space-time features of the combination of static and dynamic streams. This enables the network to autonomously find areas that are more relevant to the expression category and pay more attention to these areas. Through these means, the information of irrelevant interference areas is suppressed. In order to solve the problem of poor local robustness caused by lighting and expression changes, this paper also performs lighting preprocessing with the lighting preprocessing chain algorithm to eliminate most of the lighting effects. Experimental results on AFEW6.0 and Multi-PIE datasets show that the recognition rates of this method are 95.05% and 61.40%, respectively, which are better than other comparison methods.

A Study on the Application Effect of DSSC BIPV Window System in Office Building Considering Cooling.Heating.Lighting Energy (냉.난방 및 조명에너지를 통합 고려한 DSSC BIPV창호의 사무소건물 적용 효과 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.67-72
    • /
    • 2011
  • The aim of this study is to evaluate how much would the building energy consumption be saved by applying DSSC BIPV window which is possible to control the transmittance and express the color in the office building. For this, physical characteristics such as transmittance and reflectance, U-factor of DSSC areanalyzed and an annual energy consumption that is connected to dimming control is calculated when DSSC BIPV window is applied by alternate clear window system. As a result, It is possible to reduce the anannual energy consumption as much as4.1% by just change the clear double window system to DSSC BIPV double window system because the major factor to reduce energy consumption in the office that has much cooling load than other building is SHGC. When the thermal insulation properties of DSSC BIPV window with low-e coating and making triple window are improved, energy saving ratio is about 9%. Plus, energy saving ratio of 25~28% in lighting energy consumption is possible when the dimming control system with DSSC BIPV window is adopt.

The Understanding of Road TUNNEL Lighting(II) (교통도로 TUNNEL 조명의 이해 (II))

  • 이은풍
    • Journal of the Korean Professional Engineers Association
    • /
    • v.33 no.1
    • /
    • pp.68-74
    • /
    • 2000
  • Until the first stage of the 1990's years, Korean are not concern so much the facilities of traffic tunnel, because of them are the short length and also the quantity of them are not over the several tens in Korea. But, in latest many tunnels has been constructed and are designed in expressway and local national roads. The government office concerned forecast the numbers of tunnel are increased about 300 until the 2003 years, and then we need more interesting about the facilities of tunnel . In the tunnel, the first above of all important facilities is lighting installations which are required much electric energy and continuing maintenance.

  • PDF

Evaluation of Discomfort Glare Indices in Office Lighting (사무실 조명에서의 Discomfort Glare 계산법 적용 및 평가)

  • Hur, Nam-Don;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.13-21
    • /
    • 2002
  • In the interior lighting, usually we refer to TAL and general lighting. The last one is that we generally adopt it in the interior lighting conditions. Here, glare is most important factor of them, especially in working place using VDT. Reference or development of estimation on glare has been studied in CIE, IESNA etc. and these of glare regulations now are applied differently in the interior lighting design or estimation on glare. But we have no glare regulation in detail, of course except G classification, which has limit of itself, so in my case it is impossible to apply in the interior lighting. On this paper, with some of main glare regulations in the world and our conditions in the interior lighting which are selected carefully, in an actual state it has been estimated So, it intended to blow which one is most suitable or what factors are considered of them, also show glare index which are appropriate to our interior lighting.

A Demand-side Valuation and Application of Office lighting Dimming Control in Electricity Markets (사무소 건물의 조광제어를 통한 수요관리자원 발굴 및 전력시장에서의 활용방안에 관한 연구)

  • Kim, Jin-Ho;Kim, Seong-Cheol;Park, Jong-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.35-41
    • /
    • 2008
  • In this paper, the new demand-side evaluation of the technical potential of lighting dimming control and its applications in electricity markets have been presented. Currently, advanced power information technologies(IT) has been developed and the variations of power information technologies have widely provided the new research and business opportunities. In particular, the dimming control for the lighting devices with time-varying prices and advanced controls has its economically significant values in electricity markets. Therefore, in this paper, the authors have explored the usefulness of lighting dimming control in load management fields as well as energy efficiency fields under the changing competitive electricity market environments.

A Study on the Awareness and Needs of Employees in Office Work Environment -Focused on Pusan and Kyoungnam Area- (업무환경에 대한 이용자의 의식 및 요구에 관한 연구 -부산 및 경남지역 중심으로-)

  • 손광호
    • Korean Institute of Interior Design Journal
    • /
    • no.13
    • /
    • pp.96-101
    • /
    • 1997
  • The purpose of this study was to examine the current office work environment and suggest the needs for improvement the quality and efficiency of work. To fulfill this task, information describing various environmental conditions was gathered from generally large offices in Pusan and Major cities in Kyoungnam. Data were collected on questionnaire's general information, lighting, air quality, temperature, health problems, noise and equipment arrangements, and the size fo workspace. The extent to which the attitudes and behaviors of workers were related to these environmental conditions was then examined and scrutinized. According to the development of office automation, the interest in improvement of office environment become increased. Workstation size, individual environmental control, health care, adequate storage space and noise control should be recognized as critical to the worker's environmental satisfactiov. Finally, based on the results of this study, a number ofrecommendations can be made for alleviating some of the problems that have been identified. Designers should be interested in knowing if their environments actually function in the manner in which they were intended.

  • PDF

An Experimental Study on Control Strategy of LED System Using Daylight (주광을 활용한 LED조명시스템의 컨트롤에 관한 실험적 연구)

  • Yun, Gyeong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.33-39
    • /
    • 2010
  • Visual Environment and productivity are correlated. So we need to create a comfortable visual environment and maintain proper workplane illumination level. We can obtain lighting energy savings and comfortable visual environment using daylight and LED lights. In this study, we characterized the indoor illuminance level according to the sky condition and proposed dimming control strategy of LED lights. Energy savings in On/Off control mode are 40% at clear sky and 28% at intermediate sky. In dimming control mode, energy savings are 77.2% at clear sky and 64.1% at intermediate sky. Then we obtain the appropriate dimming control strategy of LED lights based on data. Dimming rates are 0-14.2-80(min-avg-max, %) for LED 1, 0-19.9-60% for LED 2 and 30-61.4-90% for LED 3. Lighting energy savings are 68.2% for LED dimming system applied this control method.