• 제목/요약/키워드: Office buildings

검색결과 622건 처리시간 0.025초

사무용 건물에서 전열교환 환기시스템과 일반공조기의 냉방에너지 비교분석에 관한 연구 (A Comparative Analysis on Cooling Energy of Heat Recovery Ventilator and Air Handling Unit in the Office Building)

  • 장지훈;김현수;어진선;이승복;김병선
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.123-128
    • /
    • 2016
  • Purpose: In order to save the energy consumption of buildings, buildings have been constructed with high performance insulation or airtightness. However, high performance insulation or air tightness has led to a poor indoor air quality. Therefore, HRV(Heat Recovery Ventilator) has received attention to save the energy consumption and insure a good air quality. Because existing research is almost about the performance of HRV in residential buildings, This study analyzed the effect of HRV on cooling energy consumption in commercial office building. Method: This study was proceeded at commercial office building in In-cheon. In order to evaluate the energy consumption of HRV, this study proposed two methods: estimating energy consumption of the room installed AHU(Air Handling Unit) system; estimating energy consumption of the room installed HRV system. Therefore, comparison of two methods was proceeded to evaluate energy performance of each method. Result: As the result of comparison between rooms installed AHU and HRV, the experiment showed that energy consumption of the room installed HRV system is about 22% less than the room of AHU system. This conclusion is considered because the room installed HRV system have maintained temperature well at set point temperature $26^{\circ}C$.

건축물 에너지효율등급 인증현황분석을 통한 CO2 배출량 평가 베이스라인 연구 (Study of the Assessment Baseline of Carbon Dioxide Emissions based on the Analysis of Building Energy Efficiency Rating System)

  • 정호건;신성우;이병호
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.11-19
    • /
    • 2013
  • The purpose of this study is to establish the assessment baseline of $CO_2$ emissions from building operations in the view of GHG reduction policy in Korea. The assessment baseline of $CO_2$ emissions shall be used in GHG policy and Carbon Credits in building sectors, but the assessment baseline has not been studied enough or established yet. Also, $CO_2$ emissions from building operations will be variable according to the building occupancy. Therefore the baseline will be different and this study aimed at the establishment of the assessment baseline for residential apartments and office buildings firstly. After reviews of BEER and international standards for building $CO_2$ emissions such as ISO and UNEP-SBCI documents, the analysis of BEER certification data has been pursued for 292 residential apartment complexes and 65 office buildings in South Korea during 2004~2012. As analysis results, the assessment baseline was set to 23.03 $kg{\cdot}CO_2/m^2{\cdot}yr$ or 1.95 $t{\cdot}CO_2/unit{\cdot}yr$ for residential apartment complexes, and 95.91 $kg{\cdot}CO_2/m^2{\cdot}yr$ for office buildings according to the BEER certification basis. Additional assessment baselines were calculated according to year basis, region basis, public and private basis, and GHG policy basis. Finally, the established baseline for residential apartment complexes has been applied for the pilot project in M district, Seoul, and showed 24.97% reduction rate according to the BEER certification basis.

Environmental Assessment of Smart Grid Station Project Centered on Pilot Project of Korea Electric Power Corporation Building

  • Park, Sun-Kyoung;Son, Sung-Yong;Kim, Dongwook;Kim, Buhm-Kyu
    • 한국기후변화학회지
    • /
    • 제7권3호
    • /
    • pp.217-229
    • /
    • 2016
  • Increased evidences reveal that the global climate change adversely affect on the environment. Smart grid system is one of the ways to reduce greenhouse gas emissions in the electricity generation sector. Since 2013, Korea Electric Power Corporation (KEPCO) has installed smart grid station in KEPCO office buildings. The goal of this paper is two folds. One is to quantify the reduction in greenhouse gas emissions through smart grid stations installed in KEPCO office buildings as a part of pilot project. Among components of smart grid stations, this research focused on the photovoltaic power system (PV) and energy storage system (ESS). The other is to estimate the reduction in greenhouse gas emissions when PV is applied on individual houses. Results show that greenhouse gas emissions reduce 5.8~11.3% of the emissions generated through the electricity usage after PV is applied in KEPCO office buildings. The greenhouse gas emissions reduction from ESS is not apparent. When PV of 200~500 W is installed in individual houses, annual greenhouse gas emission reduction in 2016 is expected to be approximately $2.2{\sim}5.4million\;tCO_2-eq$, equivalent to 6~15% of greenhouse gas emissions through the electricity usage in the house hold sector. The saving of annual electricity cost in the individual house through PV of 200 W and 500 W is expected to be 47~179 thous and KRW and 123~451 thousand KRW, respectively. Results analyzed in this study show the environmental effect of the smart grid station. In addition, the results can be further used as guidance in implementing similar projects.

업무용 건축물에 적용된 단열재의 경년열화에 따른 열손실량 분석 (Analysis of Heat Loss Due to Time Dependent Aging of Insulation Applied to Office Building)

  • 이도형;나환선
    • 한국태양에너지학회 논문집
    • /
    • 제37권5호
    • /
    • pp.65-75
    • /
    • 2017
  • In this study, the change of heat loss due to the degree of deterioration of the XPS insulation in KEPCO's office buildings is analyzed. The acceleration aging test of the XPS insulation was carried out according to the test method A of KS M ISO 11561: 2009. The performance of the insulation was analyzed by applying it to the three - dimensional steady state heat transfer analysis program. The acceleration aging test of the XPS insulation, show that the thermal resistance performance decreased by 1.44% at the A regional headquarters, 0.85% at the B regional headquarters, 6.41% at the C branch office, 7.76% at the D regional headquarters, 8.51% at the E branch office, and by 8.54% at the F branch office respectively. Using simulation, we determined that the thermal resistance value of E branch office decreased by 8.04%, while its heat loss increased by 8.52%. At A regional headquarters, the thermal resistance decreased by 1.38%, and the heat loss increased by 1.51%. At D regional headquarters, these value are 6.82% and 7.17%, respectively.

공동주택 평균층수 적용에 따른 경관영향 분석 및 제도운용 개선방안 연구 (A Study on the Improvement of Average Floor Height Ordinance through Analyzing Landscape Impacts of Average Floor Height System Applied to Apartment Buildings in Residential Areas of Seoul)

  • 목정훈;김성훈
    • 한국조경학회지
    • /
    • 제35권3호
    • /
    • pp.62-70
    • /
    • 2007
  • The purpose of this research is to suggest an improved method of how to apply and operate an average floor height system to rebuilt or redeveloped apartment buildings in general residential areas of Seoul. This research suggested two research findings by a computer simulation study for analyzing the difference between the average floor height of apartment buildings in experimental sites and the average of floors of buildings near experimental sites. The first finding is that an average floor height system should be applied to apartment buildings with a limitation of maximum height at sites larger than $12,000m^2$ in order to control the difference of the maximum height of buildings between apartment sites and their surroundings. The second finding is that the average floor height system should be operated by an appropriate average floor height ratio at sites greater than $50,000m^2$ in order to harmonize rebuilt or redeveloped apartment buildings with their surroundings.

The Spiral - 66 Hudson Blvd Supertall

  • Smilow, Jeffery;Chan, Patrick
    • 국제초고층학회논문집
    • /
    • 제11권1호
    • /
    • pp.41-50
    • /
    • 2022
  • The Spiral, a supertall tower at the Hudson Yards Zoning District of NYC is an new iconic commercial office tower. The spiraling terraces throughout the height of the building creates unique outdoor spaces at each level for its occupants while introduces structural challenges unlike common office towers. Innovative structural solutions and an integrated connection design and steel detailing delivery process proved to be a key factor in the success of the project.

오피스 빌딩 실내환경의 질에 관한 연구 (A Study on Indoor Environment Quality in Office Building)

  • 이경희;하미경
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2006년도 춘계학술발표대회 논문집
    • /
    • pp.259-263
    • /
    • 2006
  • The purpose of this study is to assess the characteristics of self-reported symptoms of workers in office building with HVAC system, and also to provide better workplaces in terms of comfort and health. The methods employed in this study include literature review, field observations, and survey. The self-reported symptoms of workers such as headache, fatigue, itching and dryness regarded as SBS symptoms commonly occur after around 3:00 pm and are relieved after leaving their office buildings. according to results in previous studies, above are possibly related to CO2 concentrations. It is also found work environment factors and the satisfaction on indoor environment are all associated with worker's health. Hopefully, this overview of current work environments concerning the level of satisfaction and health problems of workers would help create healthier indoor environment.

  • PDF

Knowledge Support and Automation of Paneled Building Envelopes for Complex Buildings using Script Programming

  • Park, Jungdae;Im, Jinkyu
    • 국제초고층학회논문집
    • /
    • 제4권1호
    • /
    • pp.85-90
    • /
    • 2015
  • Advances in the technology of computational design are giving architects and engineers the opportunity to analyze buildings with complex geometries. This study explores the optimization and automation process using the parametric design method, and uses digital tools to achieve surface representation and panelization for curved shaped office buildings. In this paper, we propose parametric algorithms of dimensional and geometric constraints using the Knowledge-ware scripts embedded in Gehry Technologies' Digital Project. The knowledge-based design methods proposed in this study can be used to systemize the knowledge possessed by experts in the form of data. Such knowledge is required to promote collaboration between designers and engineers in the process of CAD/CAE/CAM. The aim of this study is to integrate the process into design, which establishes an integrated process. This integration enables two-way feedback between design and construction data by combining the methods used in designing, engineering, and construction.

국내 공동주택 부문의 친환경건축 인증 평가 항목 및 사례 분석 (The Analysis on the Evaluation Items of Korea Green Building Certification Criteria by the Case Studies of Collective Housing)

  • 김창성
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.93-100
    • /
    • 2013
  • Many countries have made their best to protect the earth from global warming and to find solutions for the reduction of carbon dioxide emittion and energy consumption. Especially, buildings have emitted over 40% of carbon dioxide against whole quantities emitted to the earth. Therefore, the reduction of carbon dioxide emitted from buildings require to save the earth environment. Energy consumption of buildings in Korea has reached 24% of total energy quantities, and energy consumption of collective housing has been continuously increasing. So, Korea government has also executed the Green Building Certification Criteria(GBCC). The GBCC evaluates the 8 types of buildings - collective housing, office, school, etc - to certificate the green building. In this paper, the evaluation items of collective housing in GBCC were reviewed to be used as the reference data for future revisions by the case studies. According to the results of this study, current version of GBCC requires additional revisions about the evaluations of energy consumption monitoring, commissioning and existing building.