• 제목/요약/키워드: Office Buildings

검색결과 622건 처리시간 0.025초

오피스텔 대형 기초매트의 온도해석을 통한 온도균열제어 (Thermal Crack Control of Massive Foundation Mat of Office-tel Using Thermal Analysis)

  • 김태홍;하재담;김동석;이종열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.1181-1186
    • /
    • 2000
  • The crack of concrete induced by the heat of hydration is a serious problem, particularly in concrete structures such as biers, thick walls, box type walls, mat-slab of nuclear reactor buildings, dams or foundations of high rise buildings, etc.. As a result of the temperature rise and restriction condition of foundation, the thermal stress which may induce the cracks can occur. Therefore the various techniques of the thermal stress control in massive concrete have been widely used. One of them is prediction of the thermal stress, besides low-heat cement which mitigates the temperature rise, design change which considers steel bar reinforcement, operation control and so on. In this study, firstly it introduce the thermal cracks control technique by employing low-heat cement concrete, thermal stress analysis considering season. Secondly it shows the application of the cracks control technique like block placement.

성산동 'M'한의원 (Sungsan-dong 'M' Oriental Clinic)

  • 김흥섭
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2004년도 추계학술발표대회 논문집
    • /
    • pp.153-156
    • /
    • 2004
  • As architects and interior designers work farther and farther afield, so the connection of buildings to the particular place they are constructed becomes increasingly. Also, during the past twenty years they have made a habit of asking probing and often uncomfortable questions about how architectural conventions force patterns of behavior. In place of bricks and mortar, they have mixed store, office, clinic, and residence. In this project, the buildings consist of pharmacy, store, dental clinic, oriental clinic and residence. This building was designed by architect to have panoramic views. The view of surrounding road from every wall becomes a constant point of reference, a back drop against which the whole house revolves. Now, all the words can be suitable for describing the oriental clinics. But the oriental clinics of these days may construct the unintentional common image, may be because of the clients sense about the finishing materials or colors in vogue. The Importance of identity in the design of oriental clinic becomes higher increasingly, and with the same reason, the conviction of interior designer.

  • PDF

건축물 지하생활공간의 연기제어 기술개발 및 실물모의실험 (A Study on the smoke control in underground space of the buildings)

  • 배상환;백기성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.107-110
    • /
    • 2008
  • This study is aimed to develop fundamental technology on the smoke control method by simulation model and scale model simulation technique in underground space. Thereby, this research aimed to establish design elements and technologies required for smoke control system that is suitable to underground spaces of the high-rise residential-commercial and office buildings in order to minimize the loss of lives and property damage in case of fire.

  • PDF

Meeting the Energy Reduction Goal on a High Rise Building thru IPD Framework

  • Jeong, Pyung Oh;Lee, Peter;Kim, Sang-jin
    • 국제초고층학회논문집
    • /
    • 제2권2호
    • /
    • pp.93-96
    • /
    • 2013
  • Greenhouse gas emissions and excessive energy consumption have been an on-going world issue nowadays. We can find that the majority portion is caused by high-rise office buildings. In order to resolve these problems, it is extremely important to implement various active or passive strategies in a building design. To successfully meet these design goals and energy reduction approaches, a project building must utilize an efficient design process from the early start. One of the most effective project delivery process called Integrated Project Delivery (IPD) will be implemented in a case study project building (KEPCO) during design phase and show how important it is to plan a project's green environmental performance goal together through an early collaboration from all key project participants, which helps to construct an successful green building design without any critical construction pitfalls.

H사 공장의 환경 색채 디자인 (Environmental Color Design for the Factory of the H. Company)

  • 김정근;주정희
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.233-234
    • /
    • 2005
  • The design in this study is making a plan for the exterior color design for the factory of the H. company. The concept of this design is an integrated color program considering the physical characteristics of the buildings and the functional features of the factories. And this program is based on the aesthetic characteristics forming the men-friendly, professional environment and the environment-friendly, factory image. The scope of this design was limited to the exterior color for 1 office building and 3 factory buildings, including 7 attached facilities. All the 6 colors were selected, and the blue, the company logo color, is the main color.

  • PDF

공조설비의 필터차압 변화에 따른 에너지 소비성능 평가 (Evaluation of Energy Consumption of HVAC System for Air Filter Pressure Difference Change in Commercial Buildings)

  • 원근호;곽노열;허정호
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1227-1233
    • /
    • 2004
  • Air handling unit (AHU)'s air filter pressure difference is important for energy consumption and indoor air quality. Both energy Performance data and air filter differential pressure of AHU in real office buildings were monitored and analyzed to investigate quantitatively energy impact as dust buildup level on air filter grows. We also modeled and simulated CAV system using HVACSIM+ program to examine the energy effect of dust buildup on filters. Through analysis of time series pressure drop data, the filter pressure difference rate has been increased due to cumulative supply air flow rate increase. As filter pressure drop increased to 1 inch water column, it is found that the supply air flow rate was decreased by 10%, the chilled water flow rate was increased by 5.9% and the pump energy consumption was increased to 5.9%.

Simulating the Response of a 10-Storey Steel-Framed Building under Spreading Multi-Compartment Fires

  • Jiang, Jian;Zhang, Chao
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.389-396
    • /
    • 2018
  • This paper presents a numerical investigation on the structural response of a multi-story building subjected to spreading multi-compartment fires. A recently proposed simple fire model has been used to simulate two spreading multi-compartment fire scenarios in a 10-story steel-framed office building. By assuming simple temperature rising and distribution profiles in the fire exposed structural components (steel beams, steel column and concrete slabs), finite element simulations using a three-dimensional structural model has been carried out to study the failure behavior of the whole structure in two multi-compartment fire conditions and also in a standard fire condition. The structure survived the standard fire but failed in the multi-compartment fire. Whilst more accurate fire models and heat transfer models are needed to better predict the behaviors of structures in realistic fires, the current study based on very simple models has demonstrated the importance and necessity of considering spreadingmulti-compartment fires in fire resistance design of multi-story buildings.

A Study on the Space Reconstitution Reflecting the Characteristics of Adaptive Reuse: Focusing on High-rise Building Regeneration as a Complex Cultural Space

  • Myung-Sik Lee;Dong Hyuk Son
    • 국제초고층학회논문집
    • /
    • 제13권1호
    • /
    • pp.69-83
    • /
    • 2024
  • In this study, we focused on 'Adaptive Reuse', which has the concepts of space reconstitution and social and cultural regeneration, so that previously constructed highrise buildings can accommodate various changes in modern society, and new spatial design was developed based on the characteristics of adaptive reuse. We sought to present the concept and direction, detailed strategies, and architectural response elements of space reconstitution for the purpose of realizing the typical spatial reorganization required by modern society and seeking directions and methods of space reconstitution that can be applied to future society. The purpose is to do so.

업무용 건축물의 실내 조명기구 특성에 따른 발열 효과에 관한 연구 (Interior heating effect in an office building according to heat properties of light fixture)

  • 이윤진;안병립;김종훈;정학근;장철용;김태연
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.117-122
    • /
    • 2015
  • Purpose: Generally, 30% of the total energy consumption in office building is used for artificial indoor lightings, and almost 75-85% of electric power in fluorescent and Light-Emitting Diode (LED) lightings can be dissipated as a form of heat into indoor environment. The heat generated by indoor lightings can cause the increase of cooling load in office buildings. Thus, it its important to consider indoor lightings as a heat and light source, simultaneously. Method: In this study, we installed two kinds of indoor lightings including fluorescent and LED lightings and measured surface temperature of both indoor lightings. In addition, we obtained ambient temperature of indoor space and finally calculated total heat dissipated from plenum area and surface of lightings. Result: Total indoor heat gain was 87.17Wh and 201.36Wh in cases of six 40W-LED lightings and 64W-fluorescent lightings, respectively.

업무용 친환경건축물의 득점체계 개선에 관한 연구 (A Study on the Improvement of Scoring System by Issues as well as Criteria in the Green Building Certification System for Office Building)

  • 모혜란;문미선;한찬훈;태춘섭
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.108-117
    • /
    • 2012
  • The purpose of Green Building Certification System is to promote the environment-friendly building construction as the life-cycle environmental performance of a certain building is assessed and certified nationally(domestically). By the way, a building can get the green building certificate just with the minimum standard in prerequisite assessment criteria and with the designated scores in totals. GBCS consists of 9 assessment issues and it has 4 grades. Nevertheless the 1st. grade green building has uneven scores in each issue. In other words, it has even 0 point in a special issue. Due to the above problem, the discrimination and reliability in the GBCS grading and scoring has to be secured. This study aims at a new grading and scoring system equipped with the discrimination and reliability through analysing the scores of prerequisite assessment criteria and the scores by issues in the actually certified green office buildings.