• 제목/요약/키워드: Off-design Point

검색결과 259건 처리시간 0.024초

탈설계점 효과를 고려한 석탄가스화 복합발전용 가스터빈의 성능평가 (Performance Evaluation of the Gas Turbine of Integrated Gasification Combined Cycle Considering Off-design Operation Effect)

  • 이찬;김용철;이진욱;김형택
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.209-214
    • /
    • 1998
  • A thermodynamic simulation method is developed for the process design and the performance evaluation of the gas turbine in IGCC power plant. The present study adopts four clean coal gases derived from four different coal gasification and gas clean-up processes as IGCC gas turbine fuel, and considers the integration design condition of the gas turbine with ASU(Air Separation Unit). In addition, the present simulation method includes compressor performance map and expander choking models for considering the off-design effects due to coal gas firing and ASU integration. The present prediction results show that the efficiency and the net power of the IGCC gas turbines are seperior to those of the natural gas fired one but they are decreased with the air extraction from gas turbine to ASU. The operation point of the IGCC gas turbine compressor is shifted to the higher pressure ratio condition far from the design point by reducing the air extraction ratio. The exhaust gas of the IGCC gas turbine has more abundant wast heat for the heat recovery steam generator than that of the natural gas fired gas turbine.

  • PDF

Performance Analysis of a Triple Pressure HRSG

  • Shin, Jee-Young;Son, Young-Seok;Kim, Moo-Geun;Kim, Jae-Soo-;Jeon, Yong-Joon
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1746-1755
    • /
    • 2003
  • Operating characteristics of a triple pressure reheat HRSG are analyzed using a commercial software package (Gate Cycle by GE Enter Software). The calculation routine determines all the design parameters including configuration and area of each heat exchanger. The off-design calculation part has the capability of simulating the effect of any operating parameters such as power load, process requirements, and operating mode, etc., on the transient performance of the plant. The arrangement of high-temperature and intermediate-temperature components of the HRSG is changed, and its effect on the steam turbine performance and HRSG characteristics is examined. It is shown that there could be a significant difference in HRSG sizes even though thermal performance is not in great deviation. From the viewpoint of both economics and steam turbine performance, it should be carefully reviewed whether the optimum design point could exist. Off-design performance could be one of the main factors in arranging components of the HRSG because power plants operate at various off-design conditions such as ambient temperature and gas turbine load, etc. It is shown that different heat exchanger configurations lead to different performances with ambient temperature, even though they have almost the same performances at design points.

축류형 송풍기의 익단간극이 성능에 미치는 영향에 관한 연구 (A Study of the Tip Clearance Effect to the Performance of an Axial-Type Fan)

  • 조종현;정양범;김영철;조수용
    • 한국유체기계학회 논문집
    • /
    • 제11권6호
    • /
    • pp.7-17
    • /
    • 2008
  • Fan performances are obtained with various tip clearance gaps and stagger angles of the rotor. A tested fan is an axial-type fan of which the casing diameter is 806 mm. Two different rotors are applied to this test. One is designed on the basis of the free vortex method along the radial direction and the other is designed using the forced vortex method. The operating conditions are varied to the ultimate off-design point as well as the deign point. Overall efficiency, total pressure and input power are compared with the tip clearance gaps and different stagger angle. The experimental results show that changing of the stagger angle has minor influence to the performance when the same rotor is applied. When the tip clearance gap is less than 5% of the rotor span, the overall efficiency, total pressure loss and input power reduction are varied linearly with the variation of the tip clearance gaps. On the design point, the overall efficiency is decreased to the rate of 2.8-2.9 to the increasing of the tip clearance, but the changing rate of the overall efficiency is alleviated when the fan operates at off-design points. In particular, this rate is more quickly declined on a fan with the rotor designed using the forced vortex method. The result of the total pressure shows that the pressure reduction rate is a 0.08-0.1 according to the tip clearance, and additionally the input power reduction rate is a 0.045-0.065 at design point.

박용 터보챠저 사류 터빈의 공력설계 (A Aerodynamic Design of Mixed Flow Turbine of the Marine Turbocharger)

  • 김홍원;오국택;갈상학;하지수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.670-675
    • /
    • 2001
  • This paper describes aerodynamic preliminary design performance prediction and flow analysis for turbine of the marine middle engine turbocharger. The performance characteristics of turbocharger turbine are investigated at various operating conditions using mass flow rate and computational flow analysis for rotor and nozzle at design point are performed. Preliminary design results are performed by applying mean line and radial equilibrium theory. Performance prediction and flow analysis results show good agreement with experiments. From 3 dimensional flow analysis result, efficiency is 0.6% greater than design point. Therefore, this design approach is useful for preliminary design, and helps to increase the design capability for optimized rotor blade.

  • PDF

50KW 터보제너레이터용 가스터빈 엔진의 설계점/ 탈설계/과도성능해석 (On/Off-Design/Transient Analysis of a 50KW Turbogenerator Gas Turbine Engine)

  • 김수용;박무룡;조수용
    • 연구논문집
    • /
    • 통권27호
    • /
    • pp.87-99
    • /
    • 1997
  • Present paper describes on/off design performance of a 50KW turbogenerator gas turbine engine for hybrid vehicle application. For optimum design point selection, relevant parameter study is carried out. The turbogenerator gas turbine engine for a hybrid vehicle is expected to be designed for maximum fuel economy, ultra low emissions, and very low cost. Compressor, combustor, turbine, and permanent-magnet generator will be mounted on a single high speed (82,000 rpm) shaft that will be supported on air bearings. As the generator is built into the shaft, gearbox and other moving parts become unnecessary and thus will increase the system's reliability and reduce the manufacturing cost. The engine has a radial compressor and turbine with design point pressure ratio of 4.0. This pressure ratio was set based on calculation of specific fuel consumption and specific power variation with pressure ratio. For the given turbine inlet temperature, a rather conservative value of $1100^\circK$ was selected. Designed mass flow rate was 0.5 kg/sec. Parametric study of the cycle indicates that specific work and efficiency increase at a given pressure ratio and turbine inlet temperature. Off design analysis shows that the gas turbine system reaches self operating condition at N/$N_{DP}$ = 0.53. Bleeding air for turbine stator cooling is omitted considering low TIT and for a simple geometric structure. Various engine performance simulations including, ambient temperature influence, surging at part load condition. Transient analysis were performed to secure the optimum engine operating characteristics. Surge margin throughout the performance analysis were maintained to be over 80% approximately. Validation of present results are yet to be seen as the performance tests are scheduled by the end of 1998 for comparison.

  • PDF

2스풀 분리 배기 방식 엔진의 정상상태 성능모사 및 작동 진단 (Steady-state Performance Simulation and Operation Diagnosis of a 2-spool Separate Flow Type Turbofan Engine)

  • 추교승;성홍계
    • 항공우주시스템공학회지
    • /
    • 제13권1호
    • /
    • pp.38-46
    • /
    • 2019
  • 가스터빈 엔진에 대한 엔진 진단기술에 대한 관심이 높아지고 있으며, 엔진 건전성 진단기술에 적용 가능한 정확한 엔진 성능모사 프로그램의 중요성은 점점 더 커지고 있다. 이를 위한 엔진 성능모사는 설계점 해석으로부터 시작하여 탈설계점 성능모사, 부분부하 성능모사를 정확하게 수행해야 할 필요가 있다. 이에 따라 본 연구에서는 2-스풀 분리 배기 방식 터보팬 엔진에 대한 엔진 시뮬레이션 프로그램을 개발하고 PW(Pratt & Whitney)사의 JT9D-7R4G 엔진을 해석하였다. 각 비행영역에서의 설계점과 탈설계점에서의 정상상태 성능모사를 수행하고, 최대이륙조건 설계점과 순항상태 설계점의 해석결과의 차이를 비교하였다. 또한 구성품 성능선도 축척법 중 하나인 Reynold's Correction의 효과를 분석하였다. 개발된 프로그램의 결과와 NPSS의 결과를 비교하여 프로그램을 검증하였다.

Exploration of power take off in wave energy converters with two-body interaction

  • Wang, Hao;Sitanggang, Khairil;Falzarano, Jeffrey
    • Ocean Systems Engineering
    • /
    • 제7권2호
    • /
    • pp.89-106
    • /
    • 2017
  • The study explores a novel design of wave energy converter (WEC) that utilizes the interaction between an inside heaving vertical cylinder with an outside fixed hollow cylinder. This design originates from the oscillating water column (OWC) type WEC but replaces the pneumatic power take off (PTO) through the Wells turbine with the hydrodynamic PTO through the inside heaving cylinder. To effectively evaluate the maximum power output, the system has been modeled in the hydrodynamic software AQWA (developed by ANSYS Inc) that has accumulated extensive offshore industry users. Ranges of the PTO parameters have been examined to make sure that proper linear damping can be implemented to simulate the PTO force. Comparing the efficiency of the pneumatic PTO with the hydrodynamic PTO, it appears that the hydrodynamic PTO is more promising than the traditional Wells turbine for an OWC system.

서지 마진 증가를 고려한 원심 압축기 설계 최적화 (A Study on Centrifugal Compressor Design Optimization for Increasing Surge Margin)

  • 최재호
    • 한국유체기계학회 논문집
    • /
    • 제11권2호
    • /
    • pp.38-45
    • /
    • 2008
  • This study presents a numerical procedure to optimize the compressor design to increase the surge margin of compressor with response surface method (RSM). The Box-Behnken design method is used to reduce the number of calculation for fitting the second-order response surface. In order to consider the increase of surge margin during numerical optimization without any calculation at the surge point, the slope of compressor characteristic curve at the design point is suggested as an objective function in the present optimization problem. Mean line performance analysis method is used to get the design and off-design characteristic curves of centrifugal compressor. The impeller exit angle, impeller exit height and impeller radius are chosen as design variables. The optimum shapes show the increase of surge margin for the surge margin optimization and increase of efficiency for the efficiency optimization in comparison with an initial shape.

Navier-Stokes 방정식을 이용한 천음속 익형의 설계최적화 연구 (Design Optimization of Transonic Airfoils Based on the Navier-Stokes Equation)

  • 이형민;조창열
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 춘계 학술대회논문집
    • /
    • pp.177-185
    • /
    • 1999
  • The airfoil design optimization procedures based on the Navier-Stokes equations were developed, This procedure enables more realistic and practical transonic airfoil designs. The modified Hicks-Henne functions were used to generate the shape of airfoils. Five Hick-Henne functions were used to design upper surface of airfoil only. To enhance the ability of Hick-Henne function to generate various airfoil shape with limited number of functions, the positions of control points were adjusted through optimization procedure. The design procedure was applied to the single-point design for the drag minimization problem with lift and area constraints. The result shows the capability of the procedure to generate much realistic airfoils with very small drag-creep in the low transonic regime. This is mainly due to the viscosity effect of Navier-Stokes flow analysis. However, in the higher transonic range tile drag-creep appears. The multi-point design is shown to be an effective way to avoid the drag-creep and improve off-design performance which is very similar in the Euler design.

  • PDF

Numerical Investigation on Hydrodynamic Characteristics of a Centrifugal Pump with a Double Volute at Off-Design Conditions

  • Shim, Hyeon-Seok;Kim, Kwang-Yong
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권3호
    • /
    • pp.218-226
    • /
    • 2017
  • Severe radial thrust under off-design operating conditions can be a harmful factor for centrifugal pumps. In the present work, effects of geometry of a double volute casing on the hydrodynamic performance of a centrifugal pump have been investigated focusing on off-design conditions. Three-dimensional steady Reynolds-averaged Navier-Stokes analysis was carried out by using shear stress transport turbulence model. Numerical results for the hydrodynamic performance of the centrifugal pump were validated compared with experimental data. The hydraulic efficiency and radial thrust coefficient were used as performance parameters to evaluate the hydrodynamic characteristics of the centrifugal pump. The cross-sectional area ratio of the volute casing, the expansion coefficient of the rib structure, the distance between the rib starting point and volute entrance, and radius and width of the volute entrance, and length of the rib structure, were selected as geometric parameters. Results of the parametric study show that the performance parameters are significantly affected by the geometric variables and operating conditions. Optimal configurations of the double volute casing based on the design of experiments technique show outstanding performance in terms of the efficiency and radial thrust coefficient.