• Title/Summary/Keyword: Off-Center

Search Result 1,807, Processing Time 0.032 seconds

Effect of Source Line Location on Lift-off Acoustic Loads of a Launch Vehicle (음원 분포선 위치가 발사체 이륙 음향하중에 미치는 영향)

  • Choi, Sang-Hyeon;Ih, Jeong-Guon;Lee, Ik-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.8
    • /
    • pp.539-545
    • /
    • 2015
  • Intense acoustic load is generated when a launch vehicle lifts off, causing the damaging vibrations at the launch vehicle or satellite within the fairing. This paper is concerned with the prediction of lift-off acoustic loads for a launch vehicle. As a test example, the lift-off acoustic load on the Korean launch vehicle, NARO, is predicted by the existing calculation tool, the modified Eldred's second method. Although the acoustic sources, assumed as point sources, are to be located along the center line of the exhaust plume when using the Eldred's prediction method, the exact location of the deflected center line of exhaust gas flow is not usually known. To search for the most appropriate source positions, six models of source line distribution are suggested and the acoustic load prediction results from these models are compared with the actual measurements. It is found that the predicted sound pressure spectrum of the Naro is the most similar to the measured data when the centerline of the turbulent kinetic energy contour is used as the source line.

Testing of Load Capacity of a Foil Thrust Bearing

  • Kim, Choong Hyun;Park, Jisu
    • Tribology and Lubricants
    • /
    • v.34 no.6
    • /
    • pp.300-306
    • /
    • 2018
  • In this study, the performance of foil thrust bearings was investigated by performing bearing take-off and load capacity tests, using an in-house designed and manufactured vertical bearing test rig. The mean take-off rotational speed and maximum load capacity of the bearing specimen were ~18,000 rpm and ~80 kPa, respectively. The vertical bearing test rig was observed to yield higher coefficients of friction and frictional torques than a horizontal bearing test rig under identical test conditions. This was a result of its structural characteristics, in that the bearing specimen is placed atop the thrust runner, which keeps it from being separated from the runner after the bearing take-off. In addition, bearing take-off was observed at a higher runner rotational speed as this structure keeps air from flowing between the top foil and runner surfaces, which requires a higher runner speed. The parallel alignment between the bearing specimen and runner surfaces can be maintained within a certain range more easily in a vertical test rig than in a horizontal test rig. Because of these advantages, Korean Industrial Standard, KS B 2060, recommends a vertical bearing test rig as the standard test device for foil thrust bearings.

Graft Strategy for Coronary Artery Bypass Grafting in Patients with Severe Left Ventricular Dysfunction

  • Hong, Tae Hee;Ha, You Jin;Jeong, Dong Seop;Kim, Wook Sung;Lee, Young Tak
    • Journal of Chest Surgery
    • /
    • v.52 no.1
    • /
    • pp.16-24
    • /
    • 2019
  • Background: Optimal graft selection for coronary artery bypass grafting (CABG) in patients with severe left ventricular (LV) dysfunction remains debatable. We report an analysis of our experiences of isolated CABG in patients with severe LV dysfunction and the impact of graft strategy on long-term outcomes. Methods: We analyzed 209 patients with severe LV dysfunction (ejection fraction [EF] <30%) who underwent primary isolated CABG. Of these, 169 were revascularized with a bilateral internal thoracic arterial (ITA) graft (BITA group) and 40 were revascularized with a single ITA graft (SITA group). The mean follow-up duration was $22{\pm}32$ months. Results: There were 18 early deaths (8.6%). Overall survival at 5 years was 66.7%. The rate of freedom from cardiac-related death at 5 years was 74.1%, and was significantly higher in patients who underwent off-pump CABG (p=0.005) and in the BITA group (p=0.023). Multivariate analysis demonstrated that old age (hazard ratio [HR], 2.548; 95% confidence interval [CI], 1.134-5.762; p=0.024), off-pump CABG (HR, 0.245; 95% CI, 0.090-0.661; p=0.006), and BITA grafts (HR, 0.333; 95% CI, 0.146-0.757; p=0.009) were correlated with cardiac mortality. Conclusion: CABG in patients with severe LV dysfunction (EF <30%) showed reasonable long-term outcomes. The rate of freedom from cardiac-related death was significantly higher in patients who underwent off-pump CABG and in the BITA group. Off-pump BITA grafting strategies can be accepted as a viable primary option in patients with severe LV dysfunction if performed by an experienced surgeon.

Conceptual Design of Bevel Gear-based Leveling Station for Take-off and Landing of Unmanned Aerial Vehicles (무인 항공기 이착륙을 위한 베벨 기어 기반 수평 유지 스테이션의 개념 설계)

  • Hahm, Jehun;Park, Sanghyun;Jeong, Myungsu;Kim, Sang Ho;Lee, Jaeyoul
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.655-662
    • /
    • 2022
  • Recently, with the increase in the use of UAV(unmanned aerial vehicles), research on horizontal maintenance stations that can take off and land in various environments has been actively conducted. These stations can safely land UAV through multiple DOF(degrees of freedom) or at least 2-DOF-based actuator actuation. Among them, many researchers are dealing with the multi-DOF stewart platform due to its high safety. However, the stewart platform requires high-precision control technology because it requires a lot of torque to actuate according to the load action. Therefore, in this paper, to solve the mentioned problem, a bevel gear-based 2-DOF horizontal maintenance station system is proposed. The proposed system is configured to prevent damage due to air resistance when maintaining ships and to install it in a small space. Also, in terms of system configuration, the bevel gear-based horizontal maintenance system has the main advantage of being able to take off and land UAVs of various sizes through the replacement of station pads. The driving of the system consists of a simple form that can control the motor by adjusting the rotation speed of the motor according to the sea waveform.

Application of Off-axis Correction Method for EPID Based IMRT QA (EPID를 사용한 세기조절방사선치료의 정도관리에 있어 축이탈 보정(Off-axis Correction)의 적용)

  • Cho, Ilsung;Kwark, Jungwon;Park, Sung Ho;Ahn, Seung Do;Jeong, Dong Hyeok;Cho, Byungchul
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.317-325
    • /
    • 2012
  • The Varian PORTALVISION (Varian Medical Systems, US) shows significant overresponses as the off-center distance increases compared to the predicted dose. In order to correct the dose discrepancy, the off-axis correction is applied to VARIAN iX linear accelerators. The portal dose for $38{\times}28cm^2$ open field is acquired for 6 MV, 15 MV photon beams and also are predicted by PDIP algorithm under the same condition of the portal dose acquisition. The off-axis correction is applied by modifying the $40{\times}40cm^2$ diagonal beam profile data which is used for the beam profile calibration. The ratios between predicted dose and measured dose is modeled as a function of off-axis distance with the $4^{th}$ polynomial and is applied to the $40{\times}40cm^2$ diagonal beam profile data as the weight to correct measured dose by EPID detector. The discrepancy between measured dose and predicted dose is reduced from $4.17{\pm}2.76$ CU to $0.18{\pm}0.8$ CU for 6 MV photon beam and from $3.23{\pm}2.59$ CU to $0.04{\pm}0.85$ CU for 15 MV photon beam. The passing rate of gamma analysis for the pyramid fluence patten with the 4%, 4 mm criteria is improved from 98.7% to 99.1% for 6 MV photon beam, from 99.8% to 99.9% for 15 MV photon beam. IMRT QA is also performed for randomly selected Head and Neck and Prostate IMRT plans after applying the off-axis correction. The gamma passing rare is improved by 3% on average, for Head and Neck cases: $94.7{\pm}3.2%$ to $98.2{\pm}1.4%$, for Prostate cases: $95.5{\pm}2.6%$, $98.4{\pm}1.8%$. The gamma analysis criteria is 3%, 3 mm with 10% threshold. It is considered that the off-axis correction might be an effective and easily adaptable means for correcting the discrepancy between measured dose and predicted dose for IMRT QA using EPID in clinic.

Laser Assisted Lift-Off Process as a Organic Patterning Methodology for Organic Thin-Film Transistors Fabrication

  • Kim, Sung-Jin;Ahn, Taek;Suh, Min-Chul;Mo, Yeon-Gon;Chung, Ho-Kyoon;Bae, Jin-Hyuk;Lee, Sin-Doo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1154-1157
    • /
    • 2006
  • Organic thin-film transistors (OTFTs) based on a semiconducting polymer have been fabricated using an organic patterning methodology. Laser assisted lift-off (LALO) technique, ablating selectively the hydrophobic layer by an excimer laser, was used for producing a semiconducting polymer channel in the OTFT with high resolution. The selective wettability of a semiconducting polymer, poly (9-9-dioctylfluorene-co-bithiophene) (F8T2), dissolved in a polar solvent was found to define precisely the pattering resolution of the active channel. It is demonstrated that in the F8T2 TFTs fabricated using the LALO technique and is applicable for the larger area display.

  • PDF

The Effects of Lift-Off from Wall Thinning Signal in Pulsed Eddy Current Testing

  • Park, Duck-Gun;Angani, C.S.;Kishore, M.B.;Kim, C.G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.298-301
    • /
    • 2012
  • In order to know the effect of surface irregularity in the detection of local wall thinning of pipeline using pulsed eddy current (PEC), the lift-off effects on PEC signal have been investigated. Three kinds of parameters in the PEC signal, which is "peak amplitude", "time to peak amplitude" and "time to zero crossing" are analyzed to separate the lift-off effects in the PEC signal. The distance from sensor to the bottom of sample which is the total thickness of combined insulator and sample is kept constant. The magnitude of the differential peak amplitude is increased with increasing sample thickness, the time to peak amplitude is increased with increasing the sample thickness. To determine the effect of lift-off, a number of balanced transient responses combining wall thinning locations and lift-off distances were plotted.

Analysis of Off-axis Integral Floating System Using Concave Mirror

  • Kim, Young Min;Jung, Kwang-Mo;Min, Sung-Wook
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.270-276
    • /
    • 2012
  • An off-axis integral floating system using a concave mirror is analyzed to resolve the image distortion incurred by the off-axis optical arrangement. The concave mirror can be adopted as the floating device to improve the optical efficiency. The image distortion due to the tilting axis of the concave mirror needs to be analyzed precisely to generate the pre-distortion image. In this paper, we calculate the image deformation in the off-axis structure of the concave mirror using the geometrical optics. Using the calculation results, the compensated elemental image can be generated for the pre-distortion integrated image, which can be projected to the floating 3D image without image distortion. The basic experiments of the off-axis integral floating are presented to prove and verify the proposal.

Determining Optimal Cut-off Score for the Braden Scale on Assessment of Pressure Injury for Tertiary Hospital Inpatients (상급종합병원 입원환자의 욕창발생 위험예측을 위한 Braden Scale의 타당도 검증)

  • Park, Sook Hyun;Choi, hyeyeon;Son, Youn-Jung
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.3
    • /
    • pp.24-33
    • /
    • 2023
  • Purpose : This study aims to establish an optimal cut-off score on the Braden scale for the assessment of pressure injury to detect pressure injury risks among inpatients in a South Korean tertiary hospital. Methods : This retrospective study used electronic medical records, from January to December 2022. A total of 654 patients were included in the study. Of these, 218 inpatients with pressure injuries and 436 without pressure injuries were classified and analyzed using 1:2 Propensity Score Matching (PSM), and the generalized estimating equation was performed using SPSS Version 26 and the R Machlt package program. Results : The cut-off value on the Braden scale for distinguishing pressure injury was 17 points, and the AUC (area under the ROC curve) was 0.531 (0.484-0.579). The sensitivity was 56.6% (45.5-67.7%) and the specificity was 69.7% (66.0-73.4%). With 17 points, the Braden scale cut-off distinguished those who had pressure injuries from those who did not at the time of admission (p < .03). In the pressure injury group, the Braden score on the day of the pressure injury was 14, with significant results in all subcategories except the moisture category. Conclusion : Our findings revealed that a cut-off value of 17 was optimal for predicting the risk of pressure injuries among tertiary hospital inpatients. Future studies should evaluate the optimal cut-off values in different clinical environments. Additionally, it is necessary to conduct multicenter large sample studies to verify the effectiveness of a 17 value in PI risk assessments.

A Study on Thermal Performance Evaluation Procedures of LNG Fuel Tank (LNG 연료탱크의 단열성능 평가 절차에 관한 연구)

  • Cho, Sang-Hoon;Sim, Myung-Ji;Jung, Young-Jun;Kim, Ik-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.45-52
    • /
    • 2018
  • As guidelines for exhaust gases of ship are reinforced by the International Maritime Organization, the necessity for LNG fuelled ship is emerging. The relevant research is actively progressing to develop technologies and promote commercialization. When the residual quantity of LNG fuel tank is less than 70% by consuming fuel during operation, sloshing should be considered. We applied the Type C LNG fuel tank because medium sized LNG fuelled ships are difficult to equip with re-liquefaction system. Structural integrity and thermal performance are very important, especially in LNG fuel tanks that apply to LNG fuelled ship. Through this study, we proposed evaluation procedure of thermal performance for the Type C LNG tank, and verified the validity and effectiveness of BOR(Boil-Off Rate) test Procedure by comparing and analyzing changes in temperature, pressure, BOG(Boil-Off Gas).