• Title/Summary/Keyword: Odor concentration

Search Result 387, Processing Time 0.023 seconds

Emission Characteristics of Odors and Odorants Released from Grilling Mackerel and Pork Belly by Different Cooking Tools

  • Kim, Hyun-Jeong;Yu, Mee-Seon;Yang, Sung-Bong
    • Journal of Environmental Science International
    • /
    • v.23 no.10
    • /
    • pp.1763-1773
    • /
    • 2014
  • It is known that mackerel and pork belly release a strong odor in the process of roasting. We evaluated a dilution factor of odor arising during roasting mackerel or pork belly and the relative odor strength using several cooking tools and analyzed compounds causing odors with gas chromatograph/mass detector. Roasting pans used were grill with lid, electric grill without lid and general roasting pan, and a grill with lid can attach the activated carbon charcoal deodorant at the inside of lid. And all electric grills have a drip tray under the heater. We investigated characteristics of odor emission depending on the presence of water and deodorants in these cooking tools. Study has shown that roasting mackerel produces approximately 36 time more odors than roasting pork belly, and the reduced odor emission when roast with water. And it shows the reduced deodorant effect when cooked with water after attaching activated carbon charcoal in the cooking pan. Major odor causing compounds arising when cooking mackerel and pork belly were aldehydes with high boiling point such as octyl aldehyde with a low odor threshold value.

A Study on Separation Distance between Industrial Source and Residential Areas to Avoid Odor Annoyance Using AUSPLUME Model (AUSPLUME 모델을 이용한 악취를 피하기 위한 산업오염원과 주거단지 사이 이격거리에 관한 연구)

  • 정상진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.393-400
    • /
    • 2002
  • Separation distance between industrial source and residential areas to avoid odor annoyance was investigated using AUSPLUME model. A Gaussian plume model (AUSPLUME) for the dispersion was used to calculate odor emission from ground level area source. Using the dispersion model to calculate ambient odor concentrations, the separation distance between industrial source and residental areas was defined by %HA (percentage of highly annoyed person) and odor percentile concentration (C98). The result was compared with the separation distance of various nation guidelines for livestock buildings. The calculated separation distance for industrial source showed similar pattern comparing with various guidelines for livestock buildings.

A Study on Odor Removal of Landfill Site Leachate by Pyroligenous Liquid (목초액을 이용한 쓰레기 매립지 침출수의 악취 제거에 관한 연구)

  • 허광선;정의덕;백우현
    • Journal of Environmental Science International
    • /
    • v.8 no.5
    • /
    • pp.607-610
    • /
    • 1999
  • The odor removal of landfill site leachate was carried out using pyroligenous liquid. The constituent elements of pyroligenous liquid and leachate were also analysed, employing Atomic Absorption Spectroscopy(AAS). Before order removal, the heavy metal ions such as Pb, Zn, Cu, Mn, Fe and Ni, in pyroligenous liquid were detected with ultra trace level. However, in this liquid, other metal ions such as As, Hg and Cd were not observed. The optimum condition for removing odor fromthe leachate was observed in 15 times dilution of pyroligenous liquid. Also, the degree of outlet odor was 1. Furthermore, the concentration of odor constituent compounds, e.g. $H_2S, NH_3, NH_2$ and $CO_2$ in the leachate was remarkably reduced. Finally, water quality of the leachate was improved.

  • PDF

The Relationship Between Odor Unit and Odorous Compounds in Control Areas Using Multiple Regression Analysis (다중회귀분석을 이용한 악취 관리지역에서의 복합취기강도와 개별악취물질들의 관계에 대한 연구)

  • Kim, Jong-Bo;Jeong, Sang-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.3
    • /
    • pp.191-200
    • /
    • 2009
  • We investigated a trait of odor and the relationship between odor unit and odorous compounds using multiple regression analysis based on data compiled from Sihwa (SIC), Banwol (BIC), Banwol plating (BPIC) and Poseung industrial complex (PIC). These areas are odor control areas in Gyeonggi province. It was revealed that $NH_3$ and styrene concentrations in SIC and BPIC were relatively higher and $H_2S$ concentration especially in mc was more than five times higher than other areas. As a result of regression analysis using SAS, intensity of odor unit was highly related to concentrations of $H_2S$, TMA, styrene and n-valeraldehyde in SIC, $H_2S$, acetaldehyde, and butyraldehyde in BPIC and $NH_3$ in BIC.

Development of an Ensemble-Based Multi-Region Integrated Odor Concentration Prediction Model (앙상블 기반의 악취 농도 다지역 통합 예측 모델 개발)

  • Seong-Ju Cho;Woo-seok Choi;Sang-hyun Choi
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.3
    • /
    • pp.383-400
    • /
    • 2023
  • Air pollution-related diseases are escalating worldwide, with the World Health Organization (WHO) estimating approximately 7 million annual deaths in 2022. The rapid expansion of industrial facilities, increased emissions from various sources, and uncontrolled release of odorous substances have brought air pollution to the forefront of societal concerns. In South Korea, odor is categorized as an independent environmental pollutant, alongside air and water pollution, directly impacting the health of local residents by causing discomfort and aversion. However, the current odor management system in Korea remains inadequate, necessitating improvements. This study aims to enhance the odor management system by analyzing 1,010,749 data points collected from odor sensors located in Osong, Chungcheongbuk-do, using an Ensemble-Based Multi-Region Integrated Odor Concentration Prediction Model. The research results demonstrate that the model based on the XGBoost algorithm exhibited superior performance, with an RMSE of 0.0096, significantly outperforming the single-region model (0.0146) with a 51.9% reduction in mean error size. This underscores the potential for increasing data volume, improving accuracy, and enabling odor prediction in diverse regions using a unified model through the standardization of odor concentration data collected from various regions.

Improvement of the Ventilation Equipment in a Waste Bunker For a Municipal Waste Incinerator (자원회수시설용 폐기물 벙커의 환기설비설계 개선에 관한 연구)

  • Lee, Tae-Gu;Moon, Jung-Hwan;Hur, Jin-Huek;Lee, Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.51-59
    • /
    • 2007
  • The waste bunker usually consists of waste entrance zone and waste pit. In this paper, the distributions of air flow, $NH_3$ concentration and $H_2S$ concentration in a waste bunker were investigated to prevent an odor generated in a waste pit from dispersing to the waste entrance zone by numerical method. Four cases were considered such that 1) the waste incinerators is operated, 2) the waste incinerators is stopped, 3) the waste incinerator is operated and the direction of a supply diffuser is $45^{\circ}$ upward, 4) the waste incinerator is stopped and the direction of a supply diffuser is $45^{\circ}$ upward. In case of 1), the fresh air from the waste entrance zone is exhausted smoothly to the main exhaust grill of the waste pit. It means that an odor dispersion to the waste entrance zone will not occur. However in case of 2), the induction of fresh air is so small and the supply air with an odor in waste pit can flow to the waste entrance zone. Therefore, an odor will be dispersed to the waste entrance zone. This paper shows the solution that the supply diffuser with the direction of $45^{\circ}$ upward is chosen. As a result in case of 3) and 4), an odor dispersion to the waste entrance zone does not occurred and on odor is exhausted smoothly to the auxiliary exhaust grill.

The Characteristic and Management of Odor Emitted from Foodwaste Treatment Facility (음식물류폐기물 처리시설에서의 악취발생 특성 및 관리방안)

  • Yoo, Seung-Sung;Kim, Young-Doo;Lee, Jun-Yeon;Cha, Young-Seop;Kim, Eun-Sook;Jeon, Jae-Sik;Sunwoo, Young;Eom, Seok-Won;Chae, Young-Zoo
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.3
    • /
    • pp.353-365
    • /
    • 2012
  • This study is understanding characteristics and analyzing contributions of the odor causing compounds of complex-odor & major specified odor materials, and contribution analysis, caused pre-treatment facilities(input and storage) and post-treatment facilities(heating and drying). The target of this study is feeds-production-facilities, located in Seoul. The averaged complex-odor compounds on the boundary line is 21 times higher, and it is 15 times higher than emission standards. In cracking&collection(pre-treatment facilities), the concentration of compounds is 4,881 times, 2,080 times in drying, and 1,442 times in putting&storing facilities. Ammonia occupies the largest portion of the results of monitoring specified odor compounds in input&storage facilities, followed Acetaldehyde > Hydrogen sulfide > Methyl mercaptan. In cracking&collection, Ammonia also occupies most of odor compounds, followed Methyl mercaptan > Acetaldehyde > Dimethyl disulfide > Dimethyl sulfide > Hydrogen sulfide. Acetaldehyde > Methyl mercaptan in drying facilities. On the boundary line, however, the concentration of specified odor compounds stays below emission standards. The result of contribution analysis is that methyl mercaptan has the highest contribution in input & storage, as well as cracking&collection facilities, followed Acetaldehyde > Hydrogen sulfide > Dimethyl sulfide > Dimethyl disulfide. In the drying facilities, the contribution shows Methyl mercaptan > Acetaldehyde > i-Valeraldehyde and Butyraldehyde. Therefore, to decrease odor in foodwaste treatment facilities, proper prevention facilities need to be installed and operated, according to characteristics of individual odor compounds, based on monitored data.

Optimization of Odor Concentration by Operation of Small Station Odorizer (공급기지 부취설비 운영에 의한 천연가스 부취 농도 최적화)

  • Lee Seung-Ho;Song Taek-Yong;Baek Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.3 s.15
    • /
    • pp.36-44
    • /
    • 2001
  • In case of low odor level, accident probabilities are very high Otherwise, when the odorant concentration is too high, the deterioration of pipeline and governor facilities and the environmental problems may occur. Odorants fade in the pipeline and other equipment due to physical and chemical adsorption and reactions with odorant and materials. So, it is very important to maintain odorant concentration properly In this study, the current status of odorization technologies has been reviewed. And the characteristics of small odorant system have been analyzed. In case that the small odorant system Is introduced in our country, this paper is proposed the feasible management plan and showed feasibility results through the analysis of current available technology.

  • PDF

Aqeous Neutralizer as Reactive Solvents for Odorous Ammonia Removal

  • Park, Young-G.
    • Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.119-124
    • /
    • 2008
  • Ammonia is an inorganic compound that may cause severe odor problem. In this study the effectiveness of applying natural neutralizer to destroy and remove the odor-causing compound from gas streams was studied. Experimental result evaluated with a bench-scale apparatus via the neutralization of gas phase. This indicates that the natural neutralization depends on the gas concentration, gas residence time, temperature and pH. Removal efficiency of ammonia from gas stream was achieved by 95% using theconvection in the packed bed. This study proved the chemical neutralization technology was effective for controlling inorganic odor-causing compound.

The investigation of combined ventilation-biofilter systems using recycled treated wastewater on odor reduction efficiency

  • Febrisiantosa, Andi;Choi, Hong L.;Renggaman, Anriansyah;Sudiarto, Sartika I.A.;Lee, Joonhee
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.7
    • /
    • pp.1209-1216
    • /
    • 2020
  • Objective: The present study aimed to evaluate the performance of odor abatement by using two different ventilation-biofilter systems with recycled stablized swine wastewater. Methods: The performance of odor removal efficiency was evaluated using two different ventilation-biofilter-recycled wastewater arrangements. A recirculating air-flow ventilation system connected to a vertical biofilter (M1) and a plug-flow ventilation system connected to a horizontal biofilter (M2) were installed. Water dripping over the surface of the biofilter was recycled at a flow rate of 0.83 L/h in summer and 0.58 L/h in winter to reduce odorous compounds and particulate matter (PM). The experiments were performed for 64 days with M1 and M2 to investigate how these two ventilation-biofilter systems influenced the reduction of odor compounds in the model houses. Odorous compounds, NH3 and volatile organic compounds (VOCs) were analyzed, and microclimatic variables such as temperature, humidity, and PM were monitored. Results: Ammonia concentration inside M1 was about 41% higher on average than that in M2. PM and total suspended particles (TSPs) inside M1 were about 62.2% and 69.9%, respectively, higher than those in M2. TSPs in the model house were positively correlated with the concentration of NH3 and VOCs. Conclusion: M2 emitted lower concentration of odorous compounds than M1. Moreover, M2 could maintain the optimum temperature condition for a swine house during the cooler season. The plug-flow ventilation-horizontal biofilter system could be used for pig houses to minimize air pollution produced by swine farming activities and maintain optimum microclimate conditions for pigs.