• 제목/요약/키워드: Occupancy

검색결과 897건 처리시간 0.025초

아파트 단위 평면 변화과정에 관한 연구-안방 및 거실 중심으로- (A Study on the Change of Unit Floor Plan of Apartment House in Korea-Focused on Interior Image Preference using Computer Simulation-)

  • 김경순
    • 한국실내디자인학회논문집
    • /
    • 제12호
    • /
    • pp.50-56
    • /
    • 1997
  • In the past thirty years, apartment house has been greatly developed and the housing supply has improved some degree. However, the fact is that interior space planning of apartment house still has a lot of problems. The purpose of this study is to research the change of interior room. The 160 examples of unit floor plan(40-85m2 i.e. 12.1py-25.7py) were selected and classified according to master bedroom type and living room area when was constructed by the city of Seoul and KNHC from 1970 to 1990. And then, the change of each area, size and ratio were analyzed and researched. The result of this research can be summarized as follows: 1. Size of unit floor plan was on the increase from 16.02py to 17.86py. 2. 2 bedroom type, master bedroom showed a rise of size and occupancy ratio. Living room grew larger than 1982-1991 for size and occupancy ratio. 3. 3 bedroom type, master bedroom was increased in size and occupancy ratio was reduced to 19.99%. Size of living room became broader than master bedroom and occupancy ratio(1972-1981) increased over 1982-1991. Through this analysis and research, this study is to provide the basic data for actural design process and to suggest future trend of apartment house.

  • PDF

재실감지 센서와 스마트 플러그를 이용한 에너지 절약 시스템 (Energy Saving System using Occupancy Sensors and Smart Plugs)

  • 정경권;서춘원
    • 전자공학회논문지
    • /
    • 제52권10호
    • /
    • pp.161-167
    • /
    • 2015
  • 본 논문에서는 첨단 주택에서 가전기기 에너지 절약을 위한 재실 기반 에너지 절약 시스템을 제안하였다. 제안된 시스템은 센싱 시스템과 홈 게이트웨이 시스템으로 구성된다. 센싱 시스템은 사람의 움직임을 감지하는 PIR 센서를 장착한 무선 센싱 노드와 CT센서를 이용하여 전류 사용량을 측정하고 무선으로 전달하는 스마트 플러그로 구성된다. 스마트 플러그를 이용하여 가전기기의 전류 소모량을 측정하고, 방과 문에 설치한 재실 감지 센서를 이용하여 거주자의 재실 유무를 확인하였다. 제안한 시스템은 부재 공간의 불필요한 전기 에너지 사용량을 스위치를 끔으로서 절약한다. 실험 결과 재실 기반으로 전기 에너지를 절약한다면 약 34%를 절약할 수 있음을 확인하였다.

거실내 가구사용 실태연구$^{\circled{a}}$ (A Survey on Furniture Usage in Living room)

  • 이명옥
    • 한국주거학회논문집
    • /
    • 제3권1호
    • /
    • pp.57-67
    • /
    • 1992
  • Field survey were made. and the numbers of samples are 294 houses(3-ways;66-95.7m2, 99-128.7m2) and more than 132m')in Daegu.The major findings are as follows:1) The space evaluation of the living room is changed by the furniture occupancy rate and is different of the arrangement types.2) The space evaluation of the living room is much affected by the type of furniture which lie in near wall arrangement in 66-95.7m2, the proportion of the wall occupancy in 99-128.7m2, the proportion of the space occupancy in more of 132m2.3) In the living room an appropriate quantity of furniture is classified into 3 types of the occupying proportion.As the floor occupancy proportion supporting furniture is 13-22%, wall furniture is 10-l7f% and total furniture which combined both the supporting furniture and the wall furniture is 23-36%. Second. The proportion occupying the wall is 6-11% for the supporting furniture, 14-27% for the wall furniture, and 24-32% for the total furniture. Finally the proportion occupying the space is 12-9% for the supporting, 6-llftfer the wall furniture, and 12-l9ft for the total furniture.

  • PDF

경남지역의 전면 3칸형 아파트의 공간이용행태 및 거주후 평가에 관한 연구 -전용면적 $85\textrm{m}^2$를 전후하여- (Post Occupancy Evaluations and Spatial Behavioral Patterns of Three Bay Unit Plans in Kyungnam Aren - focusing on $85\textrm{m}^2$ apartment units size -)

  • 김상희;안주영
    • 한국주거학회논문집
    • /
    • 제13권4호
    • /
    • pp.1-10
    • /
    • 2002
  • The purpose of this study was to contribute to planning and developing various new apartment unit plans of the future through examining the differences on the spatial behavioral patterns and the post-occupancy evaluation between DK-front type and DK-rear type. 245 households which were included 79 DK-front types and 166 DK-rear types, were collected and analyzed at Masan and Gimhae cities in Kyungnam area. The result is as follows: 1) The analysis of the spatial behavioral patterns revealed that Anbang was the room for the couple independent from guests and children. Living room was the family's room for every activity, used more frequently DK-front types than DK-rear types. The family lift cycles of households, the visual unification between Living room and DK, the closed figures of DK in DK-front types have been influenced for the activities of Living room. 2) In the post-occupancy evaluation, DK-front types were positive in the lighting of DK area and its connection with Living room, while negative in the proximity from entrance to DK, cooking convenience, and the proximity between rooms. It was explained clearly through the reasons of the rejection of DK-front types from now.

Occupancy 센서와 도플러 Radar를 이용한 침상 모니터링 시스템 (Bed Side Monitoring System using Occupancy Sensor and Doppler Radar)

  • 강병욱;유선국
    • 한국멀티미디어학회논문지
    • /
    • 제21권3호
    • /
    • pp.382-390
    • /
    • 2018
  • A major accident occurring on the bed is falls that occur during at times when the care of nurses or protectors is inadequate, which is fatal to patients or the elderly. In particular, Enuresis or sleepiness caused by sleep apnea increases the risk of falls. Therefore, it is very important to detect falls and sleep apnea of patients without infringing privacy in the bed to patient's safety and accident prevention. In this paper, we reviewed the technologies developed for bed monitoring and implemented a non-intrusive monitoring system. The Occupancy Sensor allows the temperature of the bed and surrounding area to be extracted to enable track of the patient's motion. The Doppler Radar detects the patient's movements at normal times and the respiration state when patients have no movement during sleeping. It is specially designed for real-time monitoring of falling and respiration during sleeping through contactless multi-sensing while solving patient's privacy problems.

노인요양시설 입소자의 장기요양등급 개선과 서비스 질 관련요인 (The Related Factors with Improvement of Long-term Care Need of Residents and Quality of Service in Long-term Care Facility)

  • 진영란;최경원
    • 보건의료산업학회지
    • /
    • 제8권1호
    • /
    • pp.51-64
    • /
    • 2014
  • The purpose of this study was to investigate the relationship among staffing, occupancy rate, upward level change of long-term care need, and evaluation grade of facility. Data were obtained from National Health Insurance Corporation Database. Occupancy rate and evaluation grade were highest in National/public operating facilities, while they were worst in individual operating facilities. The percents of A or B grade in evaluation grade (by newly enforced law) is highest in National/public operating facilities. Multiple regression analysis showed that upward level change of care needs was very weakly associated with the number of doctors. Evaluation grade showed a weak and significant association with occupancy ratey(by old-version law)(r=.20, p<.01), upward level change of care need in group home(r=.23, p<.01) Staffing in facility did not show significantly consistent association with upward level change of care needs, evaluation grade, and occupancy rate.

대학병원 수익성에 영향을 미치는 요인 분석 (The determinants of the Profitability of University Hospitals in Korea)

  • 양종현;장동민;서창진
    • 한국병원경영학회지
    • /
    • 제15권4호
    • /
    • pp.43-62
    • /
    • 2010
  • This study provides an evidence on the determinants of the profitability of university hospital by analyzing university hospital-level data set of hospital performance during the year 2007 (32 university hospitals in total). For the study, a multiple regression model is employed in which profitability index obtained from the DEA computations, operating margin to total asset and gross revenue are used as the dependent variables, and a number of hospital operating characteristics are chosen as the independent variables such as ownership type, location, bed size, period of establishment, bed occupancy rate, admission ratio of outpatients, patients per medical specialist, personnel cost per patient, liabilities to total assets, current ratio, fixed ratio, total asset turnover, medical assistance rate and public indicator. First, the results indicate that the bed occupancy rate and liabilities to total assets are positively and significantly associated with operating margin to total asset. Second, number of beds, the bed occupancy rate and number of patients per medical specialist are positively and significantly associated with operating margin to gross revenue. Third, the bed occupancy rate, number of patients per medical specialist, liabilities to total assets, total asset turnover are positively and significantly associated with profitability index revealed from DEA.

  • PDF

재실 기반 가전기기 에너지 모니터링 시스템 설계 (Design of Occupancy-Based Appliance Energy Monitoring System)

  • 이민구;박용국;정경권;유준재
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.835-838
    • /
    • 2011
  • 본 논문에서는 주택내 가전기기의 에너지 절약을 위해 재실 기반 스마트 플러그 시스템을 제안하였다. 스마트 플러그를 이용하여 가전기기별 실시간으로 소모되는 전류를 측정하고, 방문에 재실감지 센서를 부착하여 거주자의 공간 사용을 확인한다. 제안한 시스템은 사람이 없는 공간에서 불필요하게 동작되는 가전기기의 전원 공급을 차단하여 에너지를 절약한다. 실험을 통해 가전기기의 전류 사용량을 측정하고, 다수개의 재실 감지 센서를 통해 재실 유무를 확인하였다.

  • PDF

POST-OCCUPANCY EVALUATION (POE) AFTER THE EXPANSION OF AN APARTMENT PARKING LOT

  • Park, Jin-Gu;Oh, Kyung-Taek;Ryu, Gyu-Seok;Jung, In-Su;Lee, Chan-Sik
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.1559-1563
    • /
    • 2009
  • Despite the serious lack of parking lots, studies on parking lot expansion are insufficient; research on users' satisfaction following parking lot expansion is practically nonexistent. Therefore, this study sought to provide basic data for the parking lot expansion of old apartments by comparatively analyzing users' satisfaction before and after the parking lot expansion through a questionnaire survey that targeted residents benefiting from the expanded parking lot. Results revealed a low post-occupancy satisfaction with the parking lot expansion despite the parking lot expansion and improvement of the parking lot environment. This was because the parking lot was not expanded up to the second basement floor due to the lack of appropriate parking space. Other factors included the construction cost burden and lack of connectivity of the basement parking lot with elevators. The results actually raise the need for the establishment of an optimally suitable expansion plan and development of method and technology requiring lower cost and shorter construction period in the design and construction processes for parking lot expansion. Through post-occupancy evaluation (POE) after parking lot expansion, this study quantitatively identified the problems associated with the parking lots of old apartments and ensuing expansion effects. The findings in this study can be used as basic data to seek a suitable diagnosis and evaluation method for the parking lots of old apartments.

  • PDF

주거건물의 냉방 부하 패턴에 따른 구체축열시스템 운전 방안 (Operating Mode of Thermally Activated Building System (TABS) for Residential Buildings According to their Cooling Load Profile)

  • 박상훈;여명석;유미혜;이유지;정웅준;김광우
    • 한국주거학회논문집
    • /
    • 제23권2호
    • /
    • pp.99-106
    • /
    • 2012
  • Compared to Packaged Terminal Air Conditioning Systems, Radiant Cooling Systems have the advantage of energy saving and thermal comfort. Thermally Activated Building System (TABS) is one of the radiant heating and cooling systems. The main difference between TABS and other radiant systems lies in the usage of the time-lag effect of storing heat energy in the concrete. Current energy usage in summer time is concentrated within a specific time by using Packaged Terminal Air-Conditioner (PTAC). Due to the time-lag effect of TABS, energy usage can be distributed to other time zones. To maximize this effect, it is important to determine the appropriate operating mode, which for TABS is dependent upon the cooling load generated by the occupancy schedule. In this study, occupancy schedules are determined for various residential types. The operating modes of TABS for these residential types are estimated by using a dynamic computational simulation method. The results indicate that the operating modes of TABS can be determined by residential type and occupancy schedule. The load handled ratio by TABS is set up differently according to the cooling load profile obtained from residential type and occupancy schedule. By using TABS, energy consumption could be reduced by 20% compared to PTAC.