• Title/Summary/Keyword: Occlusal pressure

Search Result 36, Processing Time 0.021 seconds

An investigation into the effect of denture adhesives on incisal bite force of complete denture wearers using pressure transducers - a clinical study

  • Kalra, Pawan;Nadiger, Ramesh;Shah, Farhan Khalid
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.97-102
    • /
    • 2012
  • Study was conducted to determine and assess the effect of different type of denture adhesives on the incisal bite force of complete denture wearers until the dislodgement of upper denture, using pressure transducer. MATERIALS AND METHODS. 30 patients out of 100 were included in the study. Based on the Kapur's method of scoring denture retention and stability, these patients were divided into 3 groups-Group A - Clinically good dentures; Group B - Clinically fair dentures; and Group C - Clinically poor dentures. A custom made occlusal force meter was constructed based on the load cell type of pressure transducers. Different adhesives (powder, paste and adhesive strips) were used in the study. Complete denture wearers were asked to bite on the load cell and the readings of incisal bite force were recorded. The readings of incisal bite force were subjected to statistical analysis using Repeated measures ANOVA followed by post-hoc bonferroni test. RESULTS. The result suggests that denture adhesives improved the incisal bite force of complete denture wearers significantly The incisal bite force (in kg) in Group A without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 2.48 (${\pm}0.16$), 3.43 (${\pm}0.11$), 6.01 (${\pm}0.11$), 3.22 (${\pm}0.09$) respectively. The incisal bite force (in kg) in Group B without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 1.87 (${\pm}0.18$), 3.35 (${\pm}0.14$), 5.34 (${\pm}0.18$), 3.21 (${\pm}0.12$) respectively. The incisal bite force (in kg) in Group C without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 1.00 (${\pm}0.17$), 3.07 (${\pm}0.14$), 4.37 (${\pm}0.26$), 2.99 (${\pm}0.14$) respectively. CONCLUSION. Within the limitations of the study, it was concluded that the use of denture adhesive was found to be significantly effective in improving the incisal bite force of complete dentures until the dislodgement of upper denture. Fittydent paste adhesive was found to be more effective than the powder and strips adhesives. The improvement in incisal bite force was found to be higher in Group C in comparison to that of Group A and Group B.

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO THE DIFFERENT FIXTURE LOCATIONS AND ANGULATIONS (임플랜트 지지 보철물에서 고정체의 식립위치와 각도에 따른 삼차원 유한요소법적 응력분석에 관한 연구)

  • Park Won-Hee;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.61-77
    • /
    • 2005
  • Statement of problem. The implant prosthesis has been utilized in various clinical cases thanks to its increase in scientific effective application. The relevant implant therapy should have the high success rate in osseointegration, and the implant prosthesis should last for a long period of time without failure. Resorption of the peri-implant alveolar bone is the most frequent and serious problem in implant prosthesis. Excessive concentration of stress from the occlusal force and biopressure around the implant has been known to be the main cause of the bone destruction. Therefore, to decide the location and angulation of the implant is one of the major considering factors for the stress around the implant fixture to be dispersed in the limit of bio-capacity of load support for the successful and long-lasting clinical result. Yet, the detailed mechanism of this phenomenon is not well understood. To some extent, this is related to the paucity of basic science research. Purpose. The purpose of this study is to perform the stress analysis of the implant prosthesis in the partially edentulous mandible according to the different nature locations and angulations using three dimensional finite element method. Material and methods, Three 3.75mm standard implants were placed in the area of first and second bicuspids, and first molar in the mandible Thereafter, implant prostheses were fabricated using UCLA abutments. Five experimental groups were designed as follows : 1) straight placement of three implants, 2) 5$^{\circ}$ buccal and lingual angulation of straightly aligned three implants, 3) 10$^{\circ}$ buccal and lingual angulation of straightly aligned three implants. 4) lingual offset placement of three implants, and 5) buccal offset placement of three implants. Average occlusal force with a variation of perpendicular and 30$^{\circ}$ angulation was applied on the buccal cusp of each implant prosthesis, followed by the measurement of alteration and amount of stress on each configurational implant part and peri-implant bio-structures. The results of this study are extracted from the comparison between the distribution of Von mises stress and the maximum Von mises stress using three dimensional finite element stress analysis for each experimental group. Conclusion. The conclusions were as follows : 1. Providing angulations of the fixture did not help in stress dispersion in the restoration of partially edentulous mandible. 2. It is beneficial to place the fixture in a straight vertical direction, since bio-pressure in the peri-implant bone increases when the fixture is implanted in an angle. 3. It is important to select an appropriate prosthodontic material that prevents fractures, since the bio-pressure is concentrated on the prosthodontic structures when the fixture is implanted in an angle. 4. Offset placement of the fixtures is effective in stress dispersion in the restoration of partially edentulous mandible.

A Finite Element Analysis of Incisors with Different Material Combinations of a Post and a Core (기둥(Post)과 핵(Core)의 이종재료 조합에 의한 치아의 유한요소해석)

  • Kang, Min-Kyu;Tak, Seung-Min;Lee, Seok-Soon;Seo, Min-Seock;Kim, Hyo-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.4
    • /
    • pp.474-481
    • /
    • 2011
  • The purpose of this study was to investigate the effect of rigidity of post core systems on stress distribution by the finite element stress analysis method. Three-dimensional finite element models simulating an endodontically treated maxillary central incisor restored with a zirconia crown were prepared. Each model contained cortical bone, trabecular bone, periodontal ligament, 4mm apical root canal filling, and post-and-core. A 50N static occlusal load was applied to the palatal surface of the crown with a $60^{\circ}$ angle to the long axis of the tooth. And three parallel type post (zirconia, glass fiber and stainless steel) and two core (Paracore and Tetric ceram) materials were evaluated, respectively. The differences in stress transfer characteristics of the models were analyzed. von Mises stresses were chosen for presentation of results and maximum displacement and hydrostatic pressure were also calculated. For the Result of the research, the model applied glass fiber to post material has lowest von Mises stress and it is suitable for material of post core systems.

Full mouth rehabilitation of an asthma patient with severe tooth wear and occlusion disharmony (심한 마모 및 교합 부조화를 가진 천식 환자의 전악 수복 증례)

  • Jo, Yu-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.22 no.4
    • /
    • pp.225-230
    • /
    • 2022
  • Objectives: Patients with excessive tooth wear should first be diagnosed for the etiology of the tooth wear. Causes of tooth wear include bruxism, clenching, and taking medications for systemic diseases. After identifying the cause of tooth attrition, the final prosthesis should be restored with an appropriate vertical dimension. Methods: A 79-year-old man with worn out teeth desired a whole dental treatment. He was on medications for high blood pressure and asthma. The treatment proceeded with a consultation with a medical doctor. The medications for asthma evoked multiple teeth wear and a loss of the vertical dimension. After recovery of 3 mm of vertical dimension, 2 months of evaluation was followed by an interim prosthesis. Results: The increased vertical dimension caused no problem in function and esthetics, and the final restoration was performed with a full monolithic zirconia crown. Group function, adequate anterior guidance, and the occlusal plane were determined. Conclusions: After the final restoration, the patient was both esthetically and functionally satisfied, and a night guard splint was delivered to prevent prosthesis fracture. The patient was informed about the potential tooth wear associated with asthma drugs and educated to visit the clinic regularly.

THE EFFECTS OF THE OCCLUSAL TRAUMA ON THE PERIODONTAL TISSUES (교합외상(咬合外傷)이 치주조직(齒周組織)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Chang, Wan-Shik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.7-11
    • /
    • 1978
  • The author attempted to observe the histological changes of the periodontal structures induced by trauma from occlusion. Eighteen healthy rabbits were devided into two groups; control and experimental group. Three rabbits were kept as control group, while metal crowns were seated on unilateral lower molar teeth of fifteen rabbits were kept as experimental group. And the interocc1usal distance of the incisal edge was kept 1.5mm from begining to the end of the experimental period. Rabbits of each group consisting with three rabbits were killed at the intervals of three days, one week, two weeks, four weeks, eight weeks. The antagonistic teeth of maxilla including periodontal teeth were excised and decalcified for histologic preparation. The results obtained were as follows. 1. Destructions and ulcer formation of the sulcular epithelium and gingival epithelium occurred and persisted from the beginning of the experiment to the four weeks after experiment. The epithelal attachment were proliferated apically. 2. The pressure site were observed at the apical protion, where they showed compression of the periodontal ligament, thrombosis and congestion of blood vessels and hemorrhages. 3. At the pressure site, there appeared osteoclasts and bone resorption from the first week of experiment and it became more prominent at the second week with the extend into the marrow spaces adjacent to the periodontal membrane. 4. The phenomenon of bone apposition and resorption occurred at the fourth week of experiment. The reverse line of bone trabecular were more prominent. And the reactions were ceased at the eighth week of experiment.

  • PDF

Evaluation of suitability and stability in a skeletal Class III complete denture patient with flabby tissue: A case report (Flabby tissue를 동반하는 골격성 Class III 환자의 양악 총의치 수복 및 적합성/안정성 평가 증례)

  • Lee, Junsuk;Hong, Seoungjin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.295-301
    • /
    • 2018
  • To obtain denture retention, support, and stability in Class III edentulous cases with flat alveolar ridges and extensive flabby tissue is very difficult. The patient was a 72-year-old male who wore ill-fitting 20 year old dentures made by non-medical institutions. There was flabby tissue on the maxillary anterior ridge. The patient showed Angle Class III skeletal relationship with severe protruded mandible. First, temporary dentures were fabricated to restore the masticatory function, and final dentures were made through non- pressure impression technique and careful the arrangement of the posterior resin teeth. Improvement of the retention and stability of the denture during the occlusal force application is reported.

Comparative study in marginal accuracy of several all ceramic crowns (전부도재관의 변연 적합도 비교평가)

  • Kim, Jeong-Mi;Jeoung, Su-Ha
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.87-92
    • /
    • 2008
  • Purpose: In this study, we tried to compare marginal accuracy when produce ceramic crown using all ceramic materials and existent metal-ceramic system. Material and methods: All-ceramic systems were E-max (Ivoclar/Vivadent, Lichtenstein), Lava(3M, U.S.A.) and Wol-ceram(Teamziereis, Germany). Metal-ceramic system(PFG) was composed of Au-Pt alloy (Metalor, Switzerlandand) and overlying ceramic(D-sign, Ivoclar/Vivadent, Lichtenstein). We fabricated metal master die with upper diameter of 7.95mm, bottom diameter of 9.00mm, height of 5.00mm, and taper of $6^{\circ}$. All ceramic system used 0.5mm thickness ceramic coping, while metalceramic system used 0.3 thickness metal coping. By adding dentin and enamel ceramics on each coping, a crown with a proximal thickness of 1.0 mm and occlusal thickness of 2.0mm was fabricated. Pressure of 2kg was applied for 10 seconds on each crown with static load compressor. Before and after cementation, we measured the marginal gap at 4 points of each crown using optical microscope. The data was analyzed using a Student's t test and repeated-measures of analyses of variance(ANOVA) followed by a Bonferroni test. A p value<0.05 was considered significant. Results: As experiment results, marginal accuracy of wol-ceram and Lava is no good when compared with marginal accuracy of PFG. But marginal accuracy of E.max is good when compared with PFG. This result showed not significant. The marginal accuracy of E.max is good when compared with marginal accuracy of wol-ceram and Lava. Conclusion: The marginal accuracy of E.max is very good when compared with marginal accuracy of another group.

  • PDF

THE COMPARATIVE STUDY OF THERMAL INDUCTIVE EFFECT BETWEEN INTERNAL CONNECTION AND EXTERNAL CONNECTION IMPLANT IN ABUTMENT PREPARATION (구강내에서 임플랜트 지대주 형성 시 내부연결방식과 외부연결방식간의 열전달 효과 비교)

  • Huh, Jung-Bo;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.60-70
    • /
    • 2007
  • Statement of problem: The cement-type abutment would be needed for the reduction of its body in order to correct the axis and to assure occlusal clearance. In the case of intraoral preparation, there is a potential risk that generated heat could be transmitted into the bone-implant interface, where it can cause deterioration of tissues around the implant and failed osseointegration. Purpose: The purpose of this study was to assess the difference of the heat transmitting effect on external and internal connection implant types under various conditions. Material and method: For evaluating the effects of alternating temperature, the thermocoupling wires were attached on 3 areas of the implant fixture surface corresponding to the cervical, middle, and apex. The abutments were removed 1mm in depth horizontally with diamond burs and were polished for 30 seconds at low speed with silicone points using pressure as applied in routine clinical practice. Obtained data were analyzed using Mann-Whitney rank-sum test and Wilcoxon / Kruskal-Wallis Tests. Result: Increased temperature on bone-implant interface was evident without air-water spray coolant both at high speed reduction and low speed polishing (p<.05). But, the difference between connection types was not shown. Conclusion: The reduction procedure of abutment without using proper coolant leads to serious damage of oral tissues around the implant irrespective of external and internal connection type.

Open reduction of mandibular fracture without maxillomandibular fixation: retrospective study (악간고정 없는 하악골 골절의 관혈적 정복술: 후향적 연구)

  • Lee, Chung-Hyun;Kim, Chul-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.4
    • /
    • pp.255-263
    • /
    • 2011
  • Introduction: Maxillomandibular fixation (MMF) is essential before surgery under general anesthesia in maxillofacial trauma patients. MMF is used basically to reconstruct the occlusion and occlusal stability to recover the facial shape and oral functions. The arch bar and wire is a traditional method for MMF, but it can not only bring pressure to the periodontal ligaments and teeth but also cause a penetrating injury to the surgeons. Materials and Methods: In this study, 198 patients with an open reduction using a manual reduction without MMF from September 2005 to May 2010 in Dankook University Dental Hospital were subjected to a follow-up evaluation during the postoperative 4 months periods. This study evaluated the incidence of complications according to the condition of the patient (gender, age), the state of bony union of the fracture sites and a numeric rating scale evaluation for postoperative pain scoring. Results: 1. The complications were classified into major and minor according to the seriousness, and the major complication rate was as low as 2.02%. Only 2 cases of re-operations (1.01%) were encountered. In the classification according to the fracture line, plate fracture was observed in both cases of mandibular symphysis fracture, and angle fractures and loosening of two screws were noted in the case of mandibular angle fracture. 2. The complication rate was similar regardless of gender and age. 3. The degree of bony union was satisfactory, and the complication rate was reduced as the bony union improved. 4. More patients complained of pain as the operation time was increased. Conclusion: The use of MMF is not always necessary if a skilled assistant is provided to help manually reduce the fracture site. Compared to other studies of mandibular fracture surgery using MMF, the complication rate was similar using only manual reduction and the patients' discomfort was reduced without MMF.

Sinking and fit of abutment of locking taper implant system

  • Moon, Seung-Jin;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.97-101
    • /
    • 2009
  • STATEMENT OF PROBLEM. Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE. In this study, Bicon$^{(R)}$ Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS. 10 Bicon$^{(R)}$ implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS. It was evident, that the amount of abutment sinking in Bicon$^{(R)}$ Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at $0.45{\pm}0.09\;mm$. CONCLUSION. Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location.