• Title/Summary/Keyword: Occlusal Stress

Search Result 184, Processing Time 0.034 seconds

Finite Element Analysis of Stress Distribution on Telescopic System for Mandibular Implant Supported Overdenture (이중관 구조 하악 임플랜트 피개의치의 응력 분포에 관한 유한요소법적 분석)

  • Oh, Jung-Ran;Woo, Yi-Hyung;Lee, Sung-Bok;Bak, Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.359-371
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the stress distribution in mandibular implant overdentures with telescopic crowns compared to bar attachment. Material and methods: Three-dimensional finite element models consisting of the mandibular bone, 4 implants, and primary bar-splinted superstructure or secondary splinted superstructure with telescopic crowns were created. Vertical and oblique loads were directed onto the occlusal areas of the superstructures to simulate the maximal intercuspal contacts and working contacts such as group function occlusion. Maximum stress and stress distribution were analysed in mandibular bone, implant abutments, and superstructures. Results: 1. In comparison of von Mises stress on mandibular bone, telescopic overdenture had a little lower stress values in vertical load and working side load except oblique load. In the mandible, the telescopic overdenture distributed more uniform stress than the bar overdenture. 2. In comparison of von Mises stress on implant abutments, telescopic overdenture had much lower stress values in all load conditions. In implant abutments, the telescopic overdenture distributed stress similar to the bar overdenture. Stress was concentrated on the distal surfaces of the posterior implant abutments in both mandibular overdentures. 3. In comparison of von Mises stress on superstructures, the telescopic overdenture had much more stress values in all load conditions. However, the telescopic overdenture distributed more uniform stress on superstructure than the bar overdenture. In the bar overdenture, stress was concentrated on each cental area of bar structures and connected area between implant abutments and bar structures. Conclusion: In the results of this study, the telescopic overdenture had lower stress values than the bar overdenture in mandibular bone and implant abutments, but more stress values in superstructures. However, if optimal material was selected in making superstructures, the telescopic overdenture was compared to the bar overdenture in stress distribution.

Stress distribution in bone surrounding maxillary molar implants under different crown-to-fixture ratio: A 3D FEM analysis (치관/고정체 비에 따른 상악 구치부 임플란트 주변골의 응력 분포에 대한 3차원 유한요소법적 분석)

  • Park, Jong-Chan;Shin, Sang-Wan;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.479-489
    • /
    • 2008
  • Statement of the problem: Under anatomical limitations on maxillary posterior region, a poor crown-to root ratio acting on dental implants can result in undesirable stress in surrounding bone, which in turn can cause bone defects and eventual failure of implants. Purpose: The purpose is to compare stress distribution due to different crown-root ratio and effect of splinting between natural teeth and implants in maxillary molar area under different loads. Material and methods: Analysis of stress arising supporting bone of the natural teeth and the implant was made with 3-dimensional finite element method. The model simulated naturel teeth was made with 2nd premolar and 1st molar in the maxillary molar region (Model T). The model simulated implants placed on same positions with two parallel implants of Straumann Dental Implant cemented abutment (Model I). Each model was designed in different crown-root ratio (0.7:1, 1:1, 1.25:1) and set cement type gold crown to make it non-splinted or splinted. After that, 300 N force was loaded to each model in five ways (Load 1: middle of occlusal table, Load 2: middle of buccal cusp, Load 3: middle of lingual cusp, Load 4: horizontal load to buccal cusp of anterior abutment only, Load 5: horizontal load to middle of buccal cusp of each abutment), and stress distribution was analyzed. Results and conclusion: On all occasions, stress was concentrated at the cervical region of the implant. Under load 1, 2 and 3, stress was not increased even when crown-root ratio increases, but under load 4 and 5, when crown-root ratio increases, stress also increased. There was difference in stress values between natural teeth and implants when crown-root ratio gradually increases; In case of natural teeth, splinting decreased stress under vertical and horizontal loads. In case of implants, splinting decreased stress under vertical loads 1,2 and 3, but increased maximal stress under loads 2 and 3. Under horizontal loads, splinting decreased stress, however the effect of splinting decreased under load 5 than load 4. Furthermore, the stress was increased, when crown-root ratio is 1.25:1. Clinical implications: This limited finite element study suggests that the stress on supporting bone may be increased under non-axial loads and poor crown-root ratio. Under poor crown-root ratio, excessive stress was generated at the cervical region of the implant, and decreased splinting effect for stress distribution, which can be related to clinical failure.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF $BR{\AA}NEMARK\;NOVUM^{(R)}$ IMMEDIATE IMPLANT PROSTHODONTIC PROTOCOL ($Br{\aa}nemark\;Novum^{(R)}$ 즉시 임플랜트 보철 수복 방법에 관한 삼차원 유한요소 분석적 연구)

  • Kim Woo-Young;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.463-476
    • /
    • 2001
  • Since the treatment of edentulous patients with osseointegrated implant was first introduced more than 30 years ago, implant therapy has become one of the most important dental treatment modalities today. Based on the previous experience and knowledge, $Br{\aa}nemark\;Novum^{(R)}$ protocol was introduced with the concept of simplifying surgical and prosthetic technique and reducing healing time recently. This protocol recommends the installation of three 5mm wide diameter futures in anterior mandible and the prefabricated titanium bars for superstructure fabrication. This study was designed to analyze the stress distribution at fixture and superstructure area according to changes of fixture number, diameter and superstructure materials. Four 3-dimensional finite element models were fabricated. Model 1 - 5 standard fixtures (13mm long and 3.75mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 2- 3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 3-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and resin Model 4-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and porcelain A 150N occlusal force was applied on the 1st molar of each model in 3 directions - vertical($90^{\circ}$), horizontal($0^{\circ}$) and oblique($120^{\circ}$). After analyzing the stresses and displacements, following results were obtained. 1. There were no significant difference in stress distribution among experimental models. 2. Model 2, 3, 4 showed less amount of compressive stress than that of model 1. However, tensile stress was similar. 3. Veneer material with a high modulus of elasticity demonstrated less stress accumulation in the superstructure. Within the limites of this study, $Br{\aa}nemark\;Novum^{(R)}$ protocol demonstrated comparable biomechanical properties to conventional protocol.

  • PDF

FINITE ELEMENT STRESS ANALYSIS OF MAXILLARY TWO IMPLANTS-RETAINED OVERDENTURE ACCORDING TO POSITION OF IMPLANT FIXTURES (상악피개의치를 위한 임플랜트의 위치에 따른 응력분포에 대한 유한요소분석)

  • Ha, Heon-Seok;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.193-200
    • /
    • 2008
  • Statement of problem: There have been a few studies about unsplinted implant retainted maxillary overdenture. Purpose: The purpose of this study was to examine the effect of different position of implant for 2 implants-retained maxillary overdenture. Materials and methods: Three-dimensional finite element models were used to reproduce an edentulous human maxilla with an implant-retained overdenture. Two implants in the canine tooth positions on both side and in the second premolar tooth positions on both side models were examined. Axial loads of 100 N were applied to the occlusal surface at the right first molar tooth positions. Maximum stress at the implant-bone interface and stress at the cortical bone surface just under the loading point were observed. Results and conclusion: Within the limits of this study, maximum stresses were concentrated around implant of canine position at loading side. The second premolar area was thought to be more favorable to distribution of stress on mucosa, alveolar bone and implants than canine area for maxillary overdenture.

A FEASIBILITY STUDY ON THE APPLICATION OF THE KNITTED GLASS FABRIC COMPOSITES TO FIXED PROSTHODONTIC RESTORATION IN DENTISTRY (Knitted Glass Fabric 강화 복합레진을 사용한 고정성 치과보철물에 대한 적용성 평가)

  • Chung Jae-Min;Lee Kyu-Bok;Jo Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.429-440
    • /
    • 2002
  • Current dental restorations present a relatively weak resistance to fracture. Owing to their unique mechanical properties, fibre-reinforced polymers are now being considered. Unidirectional or woven continuous fibres, made of glass, polyethylene, carbon or Kevlar, have been evaluated. This study focused on the use of glass fibre knitted fabrics to reinforce acrylate resins, in order to investigate the possibility to construct single crowns as well as three unit bridges. Some points affecting the final composite system were tested ; 1) static strength, with focus on the stress transfer under a occlusal contact point ; 2) modelling of a three nit bridge ; 3) fatigue strength as a posterior three unit bridge material. The study demonstrated that knitted fabric reinforcements are showing an interesting compromise between stiffness, static strength for single crown. For three unit bridge applications in the posterior arch, however knitted glass fabric reinforcements were not strong enough in fatigue An additional reinforcement in the posterior arch fixed partial denture design was recommended.

An Optimal Restoration Method of Noncarious Cervical Lesions Using Three-Dimensional Finite Element Analysis (3차원 유한요소해석을 이용한 비우식성 치아의 수복 방법)

  • Woo, Sung-Gwan;Kim, Kwang-Hoon;Park, Jeong-Kil;Hur, Bock;Son, Kwon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.7 s.196
    • /
    • pp.112-119
    • /
    • 2007
  • Cavities of Class V are caused by heavy occlusal loads due to bruxism and clenching habit. It is general to restore abfraction lesions with dental filler materials to reduce stress concentration. A material should be selected from various dental products based on long term clinical experiences or personal preference concerning filler methods. A quantitative criterion is necessary to make an evaluation of the results as dentists decide treatment methods and dental materials relying on their clinical experiences. The purpose of this study is to find an optimal restoration method and material for noncarious cervical lesions using the finite element method. An objective function was defined to minimize the sum of tensile and compressive stresses. Several models with different combinations of resins were suggested and compared in terms of the values of objective function. An optimal solution was to fill TetricFlow inside the lesion and Z100 in the remaining region with a thickness ratio of 0.125.

The relationship between dental occlusion and temporomandibular joint disorder (교합과 측두하악장애의 연관성에 관한 문헌고찰)

  • Chae-Rin Kim;Woohyung Jang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.107-113
    • /
    • 2024
  • Temporomandibular disorder is a disease caused by various factors such as trauma, mental stress, occlusal factors, and parafunctional habits. Among them, many scholars have been interested in the relationship between occlusion and temporomandibular disorder for a long time and have conducted numerous studies, but controversy over this relationship continues to this day. Based on previous studies, this review clearly establishes the relationship on occlusion and temporomandibular disorders and presents the direction for follow-up research by summarizing the limitations of current studies.

Photoelastic evaluation of Maxillary Posterior Crossbite Appliance (Maxillary Posterior Crossbite Appliance의 적용시 응력 분포에 관한 광탄성법적 연구)

  • Jang, Sung-Ho;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.31 no.6 s.89
    • /
    • pp.549-558
    • /
    • 2001
  • This study was undertaken to demonstrate the forces in the maxillary alveolar bone generated by the activation of the maxillary posterior crossbite appliance In the treatment of posterior buccal crossbite caused by buccal ectopic eruption of the maxillary second molar. A photoelastic model was fabricated using a Photoelastic material (PL-3) to simulate alveolar bone and ivory-colored resin teeth. The model was observed throughout the anterior and posterior view in a circular polariscope and recorded photographically before and after activation of the maxillary posterior crossbite appliance. The following conclusions were reached from this investigation : 1. When the traction force was applied on the palatal surface of the second molar, stresses were concentrated at the buccal and palatal root apices and alveolar crest area. The axis of rotation of palatal root was at the root apex and that of the buccal root was at the root li4 area. In this result, palatal tipping and rotating force were generated. 2. When the traction force was applied on the buccal surface of the second molar, more stresses than loading on the palatal surface were observed in the palatal and buccal root apices. Furthermore, the heavier stresses creating an intrusive force and controlled tipping force were recorded below the buccal and palatal root apices below the palatal root surface. In addition, the axis of rotation of palatal root disappeared whereas the rotation axis of the buccal root moved to the root apex from the apical 1/4 area. 3. When the traction force was simultaneously applied on the maxillary right and left second molars, the stress intensity around the maxillary first molar root area was greater than the stress generated by the only buccal traction of the maxillary right or left second molar. As in above mentioned results, we should realize that force application on the palatal surface of second molars with the maxillary posterior crossbite appliance Produced rotation of the second molar and palatal traction, which nay cause occlusal Interference. That is to say, we have to escape the rotation and uncontrolled tipping creating occlusal interference when correcting buccal posterior crossbite. For this purpose, we recommend buccal traction rather than palatal traction force on the second molar.

  • PDF

A PHOTOELASTIC STUDY ON THE STRESS DISTRIBUTION OF THE UPPER ANTERIOR TEETH WHEN RETRACT WITH HIGH PULL J-HOOK HEADGEAR (상악전치의 후방견인시 J-hook headgear의 사용이 응력분포변화에 미치는 영향에 대한 광탄성학적 연구)

  • Lee, You-Jin;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.697-709
    • /
    • 1997
  • This study was designed to investigate the stress intensity and distribution produced by 1mm activation of retraction archwire with $0^{\circ},\;7^{\circ},\;14^{\circ}$ torque and application of high polk J-hook headgear during retraction of four maxillary incisors using the photoelastic stress analysis. The photoelastic model was made with a PL-3 type epoxy resin which was substituted by alveolar bone portion. Each retraction archwire was fabricated from .020' X .025' stainless steel wire which had vertical loops in 7mm height and hooks for high pull J-hook headgear between central and lateral incisors. The high pull J-hook headgear was applied 35 degree backward and upward to occlusal plane with 200gm pet each side The findings of this study were as follows: 1. In case of $0^{\circ}$ torque, the stress was distributed from cervical 1/8 to apex of roots of central and lateral incisors which were the forms of arc mode. When the high pull J-hook headgear was applied, the stress distributed by arc mode was presented from cervical 1/2 to apex of roots of central and lateral incisors. And the stress distributed by following the root surface was presented from alveolar crest to cervical 1/2 of roots of central and lateral incisors. The stress between apecies of central and Lateral incisors was presented also. 2. In case of $7^{\circ}$ torque, the stress distributed by arc mode was presented from cervical 1/2 to apex of roots of central and lateral incisors. And the stress distributed by following the root surface was presented from alveolar crest to cervical 1/2 of roots of central and lateral incisors. When the high pull J-hook headgear was applied, the stress distributed by following the root surface was presented mote apically than without headgear. The stress between apecies of central and lateral incisors was presented also. 3. In case of $14^{\circ}$ torque, the stress distributed by following the root surface was Presented from alveolar crest to apex of roots of central and lateral incisors. When the high pull J-hook headgear was applied, the stress distributed by following the root surface was presented stronger than without headgear The stress between apecies of central and lateral incisors was presented also.

  • PDF

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE IMPLANT FRACTURES

  • Kim Yang-Soo;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.295-313
    • /
    • 2006
  • Statement of problem. Higher fracture rates were reported for Branemark implants placed in the maxilla and for 3.75 mm diameter implants installed in the posterior region. Purpose. The purpose of this study was to investigate the fracture of a fixture by finite element analysis and to compare different diameter of fixtures according to the level of alveolar bone resorption. Material and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for the 3i implant systems. Models were processed by the software programs HyperMesh and ANSA. Three-dimensional finite element models were developed for; (1) a regular titanium implant 3.75 mm in diameter and 13 mm in length (2) a regular titanium implant 4.0 mm in diameter and 13 mm in length (3) a wide titanium implant 5.0 mm in diameter and 13 mm in length each with a cementation type abutment and titanium alloy screw. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized as 650 N, and round and flat type prostheses were 12 mm in diameter, 9 mm in height were loaded to 600 N. Four loading offset points (0, 2, 4, and 6 mm from the center of the implants) were evaluated. To evaluate fixture fracture by alveolar bone resorption, we investigated the stress distribution of the fixtures according to different alveola. bone loss levels (0, 1.5, 3.5, and 5.0 mm of alveolar bone loss). Using these 12 models (four degrees of bone loss and three implant diameters), the effects of load-ing offset, the effect of alveolar bone resorption and the size of fixtures were evaluated. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView programs were used for post processing. Results. The results from our experiment are as follows: 1. Preload maintains implant-abutment joint stability within a limited offset point against occlusal force. 2. Von Mises stress of the implant, abutment screw, abutment, and bone was decreased with in-creasing of the implant diameter. 3. With severe advancing of alveolar bone resorption, fracture of the 3.75 and the 4.0 mm diameter implant was possible. 4. With increasing of bending stress by loading offset, fracture of the abutment screw was possible.