• Title/Summary/Keyword: Observers

Search Result 644, Processing Time 0.027 seconds

The comparison of cephalometric measurements between measuring methods in digital and conventional lateral cephalometric radiograph (디지털 및 일반 측방두부규격방사선사진에서 측정 방법에 따른 계측치의 비교)

  • Kim Mi-Ja;Huh Kyung-Hoe;Yi Won-Jin;Heo Min-Suk;Lee Sam-Sun;Lee Jin-Koo;Ahn Byoung-Keun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.35 no.1
    • /
    • pp.15-23
    • /
    • 2005
  • Purpose : To compare cephalometric measurement between measuring methods in digital and conventional lateral cephalometric radiograph. Materials and Methods : Twenty digital and conventional lateral cephalometric radiographs were selected. In digital group, cephalometric measurements were performed manually using hardcopies and automatically using $V-Ceph^{TM}$ program on the monitor. In conventional group, the same measurements were performed manually on conventional films, and for automatic measurement conventional films were digitized by scanner. All measurements were performed twice by 4 observers, and 24 cephalometric variables were calculated and the time spent for each measurement was recorded. The differences in measurements data and the time spent for each measurement were compared within each group. Intra-observer and inter-observer comparisons were performed. Results : In both groups, no statistically significant difference between manual and automatic measurements was observed and most of the variables didn't show statistically significant differences between methods. The observer with less experience tended to show statistically significant differences of measurements between methods, and differences from other observers. The differences of measurements between methods in digital group were lesser than those of conventional group with statistical significance in 8 variables out of 24. With automatic method and in digital group, the spent time was shorter. Conclusion : With direct digital radiograph, automatic method using manually idenitified landmarks can be preferable in cephalometric analysis. (Korean J Oral Maxillofac Radiol 2005; 35 : 15-23)

  • PDF

Characteristics of Visual Attention for the Different Type of Material Finishing in Cafe Space Using by Eye-tracking (시선추적을 이용한 카페 공간 마감재 차이의 시각주의력 특성)

  • Choi, Jin-Kyung;Kim, Ju-Yeon
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • This study aims to investigate whether there is intensionally changing eye - gaze on the cafe space images with floor finishing materials. In the Yarbus' experiment, he argued that changing information that an observer is asked to obtain from an image changes pattern of eye movements. Based on the scan path evidence, this research have questions as (1) the difference of visual attention on finishing floor material stimulus, (2) visual attention of initial activity time and type of movement paths on AOIs, and (3) visual relation floor area with another AOIs. Eye movements were recorded with the SMI REDn Scientific, which sampled eye position at 30Hz and lasted 2 minutes(120s). Although viewing was binocular, only the right eye was tracked. Of the 66 observers(mean age 22 years, standard deviation: ${\pm}1.82$) who participated in the experiment done by the four point calibration and validation procedures at the beginning tasks. Analyzing qualitative data from the number of fixation and duration on AOIs divided into four parts (AOI I-Floor, AOI II-Wall, AOI III-Ceiling, and AOI IV-Counter) in the stimulus. The results from this experiment analyzed as follows. First, it was significant in the difference of the average number of AOIs fixation times observed for the spatial image using the wood tile flooring material and the polishing tile. The wood tile flooring of stimulus had higher fixation number on AOI-II, AOI-III, and AOI-IV than the polishing tile. On seeing AOI-I was higher attention in the polishing tile stimulus. Second, the observers examined AOI-II intensively in both stimuli. However, the visual intensity was also followed by on the AOI-IV and AOI-I in the wood tile flooring stimulus, and on AOI-I, AO-IV in the polishing tile. Third, visual attention data on each AOIs have divided into the time range of "5 sec" for both images. In the wood tile stimulus, the horizontal movement path followed by AOI-II, AOI-IV, and AOI-II. In the polished tile stimulus, the movement path followed by moving vertically to AOI-II, AOI-I, and AOI-II. This study approached meaningfully and found out the characteristics of visual attention, according to the different intentions of visual attention, the relationship pathways of visual mechanism appeared and also activated by eye-tracking experiments.

A Study on Kindergarten's Meal Service Program and Children's Food Intake (유아 교육기관의 급식 운영실태와 유아의 식사 섭취량 조사)

  • Lee Youngmee;Oh Yu-Jin
    • Journal of Nutrition and Health
    • /
    • v.38 no.3
    • /
    • pp.232-241
    • /
    • 2005
  • Today, the role of kindergarten is more important as nutrition provider through snack and meal services. Desirable kinds and amounts of food items at school lunch menu were important factors of nutrients intakes in children. This study was performed to assess the kindergarten's meal service program (snack and lunch) and the consumption amount of lunch according to each dishes. Twenty four institutions that cared over one hundred children were observed at Seoul and Kyunggido area. Well-trained observers checked meal and snack serving activity and foodservice facilities by formal checklist. And using the weighing method assessed the consumption levels of food items at lunch. During 3 days, 30 children in each kindergarten were selected randomly according to age, observers measured serving and residual weight of each food. The data was compiles by performing ANOVA-test using SPSS WIN 10.0. The result were as follows: 1) Foodservice facilities in kindergarten was limited to provide qualified foodservice. $91.7\%$ of institution had kitchen, $41.7\%$ had dinning. The kitchen equipment possession rate was $12.5\%$ (oven), $30.8\%$ (heating cabinet), $58.3\%$ (refrigerator). The rate of using document about foodservice was used $83.3\%$ (menu list), $41.7\%$ (daily foodservice record), $25\%$ (standard recipe). $41.7\%$ of institution employed licensed dietitian. Only $41.7\%$ of subjects preserved meal after daily meal service. 2) Meal serving size was decided by teacher, $54.5\%$ at snack and $43\%$ at lunch and pre-divided individual portion type was $36.4\%$ at snack and $28.6\%$ at lunch. The rate of cleaning activity before meal was $72.2\%$ at snack, $90.5\%$ at lunch. And nutrition or sanitation education activity was more performed at lunch time, for examples brushing teeth activity was $12.5\%$ at snack $85.7\%$ at lunch. 3) The consumption amounts of plain cooked rice was $112.7{\pm}26.1{\cal}g$, cooked rice and cereal was $93.06{\pm}27.97{\cal}g$, curry rice was $208.35{\pm}64.84{\cal}g$ and the consumption amounts of these main dishes was significantly different by age (p < 0.001). The consumption amounts of soup was very different according to children's preference. The consumption amounts of seaweed soup was $120.18{\pm}82.13{\cal}g$, wild sesame and bean-paste soup was $40.64{\pm}23.16{\cal}g$. The consumption range of kimchis was from $6{\cal}g\;to\;13{\cal}g$, jorim (braised food) was from $3{\cal}g\;to\;25{\cal}g$, fried food (include stir fried, deep fat fried, pan fried) was from $14.5{\cal}g\;to\;22{\cal}g$, vegetable dish was from $3{\cal}g\;to\;16{\cal}g$. These consumption amount of each dishes was not reached recommended portion size of nutritionally planning menu by nutritionist.

Accuracy and reliability of 2-dimensional photography versus 3-dimensional soft tissue imaging

  • Ayaz, Irem;Shaheen, Eman;Aly, Medhat;Shujaat, Sohaib;Gallo, Giulia;Coucke, Wim;Politis, Constantinus;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • Purpose: This study was conducted to objectively and subjectively compare the accuracy and reliability of 2-dimensional(2D) photography and 3-dimensional(3D) soft tissue imaging. Materials and Methods: Facial images of 50 volunteers(25 males, 25 females) were captured with a Nikon D800 2D camera (Nikon Corporation, Tokyo, Japan), 3D stereophotogrammetry (SPG), and laser scanning (LS). All subjects were imaged in a relaxed, closed-mouth position with a normal smile. The 2D images were then exported to Mirror® Software (Canfield Scientific, Inc, NJ, USA) and the 3D images into Proplan CMF® software (version 2.1, Materialise HQ, Leuven, Belgium) for further evaluation. For an objective evaluation, 2 observers identified soft tissue landmarks and performed linear measurements on subjects' faces (direct measurements) and both linear and angular measurements on all images(indirect measurements). For a qualitative analysis, 10 dental observers and an expert in facial imaging (subjective gold standard) completed a questionnaire regarding facial characteristics. The reliability of the quantitative data was evaluated using intraclass correlation coefficients, whereas the Fleiss kappa was calculated for qualitative data. Results: Linear and angular measurements carried out on 2D and 3D images showed excellent inter-observer and intra-observer reliability. The 2D photographs displayed the highest combined total error for linear measurements. SPG performed better than LS, with borderline significance (P=0.052). The qualitative assessment showed no significant differences among the 2D and 3D imaging modalities. Conclusion: SPG was found to a reliable and accurate tool for the morphological evaluation of soft tissue in comparison to 2D imaging and laser scanning.

Stereoscopic Depth from 3D Contents with Various Disparity (화면 시차로부터 지각되는 3D 컨텐츠의 입체시 깊이)

  • Kham, Keetaek
    • Journal of Broadcast Engineering
    • /
    • v.21 no.1
    • /
    • pp.76-86
    • /
    • 2016
  • This study was investigated whether the perceived depth was changed depending on the measurement methods. In the method of direct comparison, virtual object with one of the various binocular disparities was presented in the frontal space with LEDs which were used for depth estimation for a binocular stimulus, while in the method of indirect comparison, visual object was presented in the frontal space but the LEDs were placed rightward at the angle of 45 degree from the mid-sagittal line. In these experimental setup, the depth of binocular stimulus was directly matched that of LED in direct comparison condition. In indirect comparison condition, however, observer estimated the depth of binocular stimulus, turned one's head rightward to the array of LEDs and turned on the LED which was supposed to be the same depth as binocular stimulus. Additionally, it was investigated whether the perceived depth was different depending on observer's stereo acuity. The results showed that perceived depths measured in the direct comparison were more similar to the depth predicted from geometry than those in the indirect comparison, and that the perceived depths from observers with high stereo acuity were similar to the predicted depth from geometry those from observers with low stereo acuity. These results indicated that stereoscopic depths of the binocular stimuli would vivid and compelling when binocular stimuli was simultaneously presented with real objects in the same visual space, like a mixed reality.

A Visualization Method of High Definition Weather Radar Information for various GIS Platforms (다양한 GIS 플랫폼을 위한 고해상도 기상레이더 정보 시각화 기법)

  • Jang, Bong-Joo;Lim, Sanghun;Lee, Suk-Hwan;Moon, Kwang-Seok;Chandrasekar, V.;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.11
    • /
    • pp.1239-1249
    • /
    • 2013
  • According to development of weather radar, researches about observation, analysis or forecast of weather phenomena such as tornado, flash-flood etc. were encouraged by reducing frequency interferences, transmission noises, attenuations of radar signal. In contrast, there is a growing interest in the visualization and expression methods for weather radar data but weather radar manufacturers or the organs of government for weather are just busy interpreting expressed weather images projected on GIS. We propose an effective high definition weather radar information visualization method able to apply various GIS platforms to observe and take actions against rapid local weather changes effectively. In this paper, first we change information acquired from weather radar to raster or vector type high definition data structures using specific algorithms. And then, we quadrate our processed raster/vector type weather data with various GIS platforms accurately to make observers can recognize and check weather situations over exact geographical positions and elevations intuitively. Experimental results verify that our method make observers can recognize and analyze weather changes, tornados, local downpours or flash floods accurately by analyzing high definition weather radar data combined with GIS platform including detailed target locations and elevations.

Observer Variation Factor on Advanced Method for Accurate, Robust, and Efficient Spectral Fitting of java Based Magnetic Resonance User Interface for MRS data analysis (java Based Magnetic Resonance User Interface의 Advanced Method for Accurate, Robust, and Efficient Spectral Fitting 분석방법의 관찰자 변동 요소)

  • Lee, Suk-Jun;Yu, Seung-Man
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.143-148
    • /
    • 2016
  • The purpose of this study was examined the measurement error factor on AMARES of jMRUI method for magnetic resonance spectroscopy (MRS) quantitative analysis by skilled and unskilled observer method and identified the reason of independent observers. The Point-resolved spectroscopy sequence was used to acquired magnetic resonance spectroscopy data of 10 weeks male Sprague-Dawley rat liver. The methylene protons ($(-CH_{2-})n$) of 1.3 ppm and water proton ($H_2O$) of 4.7 ppm ratio was calculated by LCModel software for using the reference data. The seven unskilled observers were calculated total lipid (methylene/water) using the jMRUI AMARES technique twice every 1 week, and we conducted interclass correlation coefficient (ICC) statistical analysis by SPSS software. The inter-observer reliability (ICC) of Cronbach's alpha value was less than 0.1. The average value of seven observer's total lipid ($0.096{\pm}0.038$) was 50% higher than LCModel reference value. The jMRUI AMARES analysis method is need to minimize the presence of the residual metabolite by identified metabolite MRS profile in order to obtain the same results as the LCModel.

A comparative study on the accuracy of digital subtraction radiography according to the aquisition methods of reconstructed images (재구성영상 형성방법에 따른 디지털영상공제술의 정확성 비교연구)

  • Huh Young-June;Jeon In-Seong;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;Kim Jong-Dae
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.107-111
    • /
    • 2002
  • Purpose : To compare the accuracy of digital subtraction images acquired by two different methods different in positioning four reference points for geometrical standardization. Materials and Methods : A total of 36 digital radiographic images of 6 volunteers were taken at the areas of the incisor, premolar, and molar of both the maxilla and mandible using the Digora system. Each image was moved 4 mm vertically and horizontally. Four oral and maxillofacial radiologists performed digital subtraction radiography between the paired images before and after movement using Emago (Oral Diagnostic Systems, Amsterdam, The Netherlands) and Sunny (Biomedisys Co., Seoul, Korea). The standard deviation of the internal gray value in Region of Interest (ROI) was statistically analyzed between the two programs using the paired t-test. Results : The standard deviation of pixel gray values from the digital subtraction images using the Sunny program were lower than that of the Emago program (p<0.05). All observers showed significant differences between each other when the Sunny program was used (p<0.05), but one observer showed a significantly higher score than other observers when they used Emago (p<0.05). The standard deviations of premolar area from both Sunny and Emago programs were significantly higher than those of anterior and molar regions (p<0.05). Conclusion: The subtracted images using the Sunny program were more accurate and sensitive than those taken using the Emago program.

  • PDF

Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

  • Pittayapat, Pisha;Jacobs, Reinhilde;Odri, Guillaume A.;Vasconcelos, Karla De Faria;Willems, Guy;Olszewski, Raphael
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.15-22
    • /
    • 2015
  • Purpose: This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Materials and Methods: Thirty-two cone-beam computed tomographic scans (3D Accuitomo$^{(R)}$ 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim$^{(R)}$ software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). Results: The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from $0.43{\pm}0.34mm$ to $0.51{\pm}0.46mm$. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. Conclusion: A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.

The Influence of Sensory Interference Arising from View-Height Differences on Visual Short-Term Memory Performance (조망 높이의 차이가 초래한 감각적 간섭이 시각단기기억 수행에 미치는 영향)

  • Ka, Yaguem;Hyun, Joo-Seok
    • Science of Emotion and Sensibility
    • /
    • v.23 no.1
    • /
    • pp.17-28
    • /
    • 2020
  • Lowering observers' view-height may increase the amount of occlusion across objects in a visual scene and prevent the accurate identification of the objects in the scene. Based on this possibility, memory stimuli in relation to their expected views from different heights were displayed in this study. Thereafter, visual short-term memory (VSTM) performance for the stimuli was measured. In Experiment 1, the memory stimuli were presented on a grid-background drawn according to linear perspectives, which varied across observers' three different view-heights (high, middle, and low). This allowed the participants to remember both the color and position of each memory stimulus. The results revealed that testing participants' VSTM performance for the stimuli under a different memory load of two set-sizes (3 vs. 6) demonstrated an evident drop of performance in the lowest view-height condition. In Experiment 2, the performance for six stimuli with or without the grid-background was tested. A similar pattern of performance drop in the lowest condition as in Experiment 1 was found. These results indicated that different view-heights of an observer can change the amount of occlusion across objects in the visual field, and the sensory interference driven by the occlusion may further influence VSTM performance for those objects.