• Title/Summary/Keyword: Observed frequency

Search Result 4,526, Processing Time 0.036 seconds

The Ultrasonographic Images of Normal Uterus in Korean Native Cow (한우 정상 자궁의 초음파적 관찰)

  • Park, Chul-Ho;Kim, Jae-Hong;Mun, Byeong-Gwon;Kim, Hee-Su;Kim, Bang-Sil;Lee, Ju-Hwan;Park, In-Chul;Kim, Jong-Taek;Suh, Guk-Hyun;Oh, Ki-Seok;Son, Chang-Ho
    • Journal of Embryo Transfer
    • /
    • v.24 no.3
    • /
    • pp.159-167
    • /
    • 2009
  • Ultrasonographic examination was performed to observe the ultrasonographic image of Korean native cows' normal uterus in condition of in vitro and in vivo. The experiment was done 28 slaughtered cows' uterus using immersed in water in vitro, and 41 healthy breeding cows taken rectal ultrasonography in vivo. Ultrasonographic examination of uterine was taken on the reference of cross section of intercornual ligaments' cranial. Each uterus on the experiments was compared by estrous cycle and ultrasonographic frequency. The uterine structure using ultrasonography was 5 layers of uterine horn in vivo as well as in vitro. Uterine horn was observed to be distinguished from inside to outside as endometrium to inner echogenic layer, circular muscle layer to slightly echogenic elliptical layer, stratum vasculare to central echogenic layer, longitudinal muscle layer to slightly echogenic arched layer, and perimetrium to outer echogenic layer, respectively. According to the observation of uterus related to estrous cycle and ultrasonographic examination, uterine endometrium in vitro was constantly founded irrespective of estrous cycle and ultrasonographic frequency. On the low frequency, endometrium and circular muscle layer in estrus were prone to distinguished than in diestrus. On the high frequency, endometrium and circular muscle layer were always distinguished regardless of estrous cycle. In vivo, uterine endometrium and circular muscle layer were observed regardless of estrus and ultrasonographic frequency. On the low frequency, stratum vasculare and longitudinal muscle layer were not likely to be distinguished in diestrus, but estrus. On the high frequency, stratum vasculare and longitudinal muscle layer were observed regardless of estrous cycle. Also, every uterine structure was easily distinguished on high frequency than low frequency owing to precision of distinction in layers. The difference of results followed by the experiments conditions between in vitro and in vivo was that uterine endometrium and circular muscle layer in diestrus in vitro were difficult to be distinguished and uterine lumen was observed during whole estrous cycle. In vivo, It was founded that the distinction of stratum vasculare and logitudinal muscle layer in diestrus was complicated and uterine lumen was observed during only estrus. In view of the result so far achieved, normal uterine structure divided in 5 layers on ultrasonography was accorded with microscopic organization, uterine structure was likely to be observed during estrus than diestrus, high frequency checkup than low frequency, and uterine endometrium, circular muscle, stratum vasculare was easily observed regardless of estrous cycle and ultrasonographic frequency.

Frequency Response of the electrode for Indirect-contact ECG (간접접촉 심전도 측정용 전극의 주파수 특성)

  • Lim, Yong-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.249-253
    • /
    • 2008
  • The indirect-contact ECG (IDC-ECG) was introduced by a prior study for daily non-intrusive measurements. To improve the signal quality and to extend the application area of IDC-ECG, close study of the frequency characteristics of the IDC-ECG is necessary. In this study, the frequency response of the active electrode for several sample clothes was measured under conditions of actual IDC-ECG measurement with human body. Higher gain in low frequency range than expected by prior study was observed. In addition to it, wide variation in gain according to the cloth type in the low frequency range was observed. Variation in gain caused by moisture variation in the clothes was also observed. This study shows that the parallel R-C connection is proper for electrode model and the resistive factor is influenced by moisture in the clothes. This study is the first that provides the frequency response of the electrode in the actual indirect-contact ECG measurement and it is expected that the results will be helpful to improve the indirect-contact ECG method.

Frequency Related Information and Syllable Structure Constraints on Sino-Korean (한국 한자음의 빈도 관련 정보 및 음절 구조 제약)

  • Shin, Ji-Young
    • Phonetics and Speech Sciences
    • /
    • v.1 no.2
    • /
    • pp.129-140
    • /
    • 2009
  • The purpose of the present study is to investigate frequency related information and syllable structure constraints on Sino-Korean. Previous studies on Sino-Korean have mostly investigated the historical change of sounds and reviewed archaic features of Chinese language in Sino-Korean. Unfortunately, there is little study on the sounds of contemporary Sino-Korean in terms of syllable structure constraints. For the purpose of the present study, sounds of 7,742 Chinese characters used in Sino-Korean (7,795 syllables) were investigated and syllable matrices made based on the results of frequency related information. As a result, 483 syllable types were observed and the most frequently observed syllables were as follows: /ku/ (103) > /ki/ (100) > /ju/ (87) > /pi/ (86). Only 16 out of 19 consonants are used for Sino-Korean. /$t^{\ast}$/ and /$p^{\ast}$/ are never used in Sino-Korean and /kh, $s^{\ast}$, $k^{\ast}$/ occur only a few times (3, 2, 1 respectively). /k/ (17.5%) shows the highest frequency and /n, ${\eta}$, 1, tc, m/ occupied the next rankings. Among 20 vowel types, /a/ showed the highest frequency and /o, u, i, $j{\Lambda}$, ${\Lambda}$/ occupied the next rankings. Based on the syllable matrices, gaps were observed and classified into accidental or systematic ones. Onset and nucleus, nucleus and coda, onset and coda, and other syllable structure constraints of Sino-Korean were listed.

  • PDF

Ratio of predicted and observed natural frequency of finite sand stratum

  • Prathap Kumar, M.T.;Ramesh, H.N.;Raghavendra Rao, M.V.;Raghunandan, M.E.
    • Geomechanics and Engineering
    • /
    • v.1 no.3
    • /
    • pp.219-239
    • /
    • 2009
  • Vertical vibration tests were conducted using model footings of different size and mass resting on the surface of finite sand layer with different height to width ratios and underlain by either rigid concrete base or natural red-earth base. A comparative study of the ratio of predicted and observed natural frequency ratio of the finite sand stratum was made using the calculated values of equivalent stiffness suggested by Gazetas (1983) and Baidya and Muralikrishna (2001). Comparison of results between model footings resting on finite sand stratum underlain by the rigid concrete base and the natural red-earth base showed that, the presence of a finite base of higher rigidity increases the resonant frequency significantly. With increase in H/B ratio beyond 2.0, the influence of both the rigid concrete and natural red-earth base decreases. Increase in the contact area of the footing increases the resonant frequency of the model footings resting on finite sand stratum underlain by both the types of finite bases. Both the predicted and the observed resonant frequency ratio decreases with increase in force rating and height to width ratio for a given series of model footing.

A study on bulk deposition flux of dustfall and insoluble components by the wind intensity in Busan, Korea (바람의 강도에 따른 강하먼지와 불용성 성분의 조성특성)

  • 황용식;김유근;박종길;문덕환
    • Journal of Environmental Science International
    • /
    • v.11 no.7
    • /
    • pp.651-662
    • /
    • 2002
  • Weather elements were observed by the AWS (Automatic Weather System) and dustfall particles were collected by the modified American dust jar (wide inlet bottle type) at 4 sampling sites in Busan area from March. 1999 to February, 2000. Thirteen chemical species (Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Ni, Pb, Si, and Zn) were analyzed by AAS and ICP. The purposes of this study were to estimate qualitatively various bulk deposition flux of dustfall and insoluble components by applying regional and seasonal wind intensity. Frequency of wind speed were found in order of low(1-3m/s), very low(<1m/s), medium(3-8m/s) and high(>8m/s), and annual mean had higher range at low(1-3m/s) for 56.3%. Strong negative linear correlation were observed between dustfall and wind direction (northeastern and eastern), but strong positive linear correlation were observed between dustfall and wind direction (western and northwestern) at industrial, commercial and coastal zone(p<0.05). While a negative correlation were observed between wind speed frequency of very low(<1 m/s) and dustfall, and positive correlation were observed between wind speed frequency of low(1-3m/s) and dustfall in coastal zone(p<0.05). The correlation coefficient was observed 0.556 between wind speed frequency of low(1-3m/s) and Ni by commercial zone(p<0.05). The correlation coeffcient show well-defined insoluble trace metals (Al, Ca, Cr, Cu, Fe, Pb, and Zn) and wind speed frequency of low(1-3m/s) at coastal zone, which was found significant difference(p<0.01).

THE COMPLEX PERMEABILITY AND MATCHING FREQUENCY OF FERRITE MICROWAVE ABSORBER

  • Shin, Jae-Young;Oh, Jae-Hee
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.800-804
    • /
    • 1995
  • The complex permeability dispersions and the microwave absorbing phenomena are investigated in ferrite microwave absorber. The complex permeability of NiZn ferrite, NiZnCo ferrite, and Y-type hexagonal ferrite were measured in 200MHz-14GHz range. Two types of resonances, the domain wall and the spin rotational resonance, were observed. With a ferrite particle with a diameter of about $1\;\mu\textrm{m}$, only spin rotational resonance were observed. The theoretical matching frequency is determined by plotting the measured complex permeability locus on the impedance matching solution map. One or two impedance matching phenomena are observed in the ferrite absorbers according to their complex permeability loci on the impedance matching solution map. The first matching frequency, found in the ferrite-rubber composites, which was higher than that of spin rotational resonance, increased with spin rotational resonance frequency.

  • PDF

Genotype and Allele Frequency of the Short Tandem Repeat F13A01 Locus by Polymerase Chain Reaction in Korean (한국인에서 중합효소반응을 이용한 short tandem repeat 유전좌위 F13A01 유전자형 및 대립유전자 빈도)

  • Young-Su Lee;Chang-Lyuk Yoon
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.317-329
    • /
    • 1996
  • Allelic frequency and genotype distribution of short tandem repeat(STR) F13A01 locus was analysed by polymerase chain reaction, polyacrylamide gel electrophoresis and silver staining from human genomic deoxyribonucleic acid(DNA) was extracted from 205 unrelated Korean to be applied to forensic identification and parentage testing as a database. The results were as follows : 1. 5 alleles and 11 genotypes of F13A01 locus were detected and heterozygosity value was 62.0% and the observed each alleles and allelic frequency was 3.2(0.363), 4(0.105), 5(0.063), 6(0.466), 16(0.002). 2. The allelic diversity value was 0.639 and the power of discrimination was 0.804.3. Compared with observed number of alleles and allele frequency in ethnic difference, result was appeared to be similar to that of Japanese and Asians, while was appeared to be much different to that of Blacks and Caucasians in the observed number of alleles and frequency of allele 3.2, 5, 7. From the above result of this investigation, the allelic frequency of STR F13A01 locus in the Korean was considerd to be useful for individual identification and parentage testing as a database.

  • PDF

Mechanical and Structural Behaviors of HfN Thin Films Fabricated by Direct Current and Mid-frequency Magnetron Sputtering

  • Sung-Yong Chun
    • Corrosion Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.30-35
    • /
    • 2023
  • Hafnium nitride (HfN) thin films were fabricated by mid-frequency magnetron sputtering (mfMS) and direct current magnetron sputtering (dcMS) and their mechanical and structural properties were compared. In particular, changes in the HfN film properties were observed by changing the pulse frequency of mfMS between 5 kHz, 15 kHz, and 30 kHz. The crystalline structure, microstructure, 3D morphology, and mechanical properties of the HfN films were compared by x-ray diffraction, field-emission scanning electron microscopy, atomic force microscopy, and nanoindentation tester, respectively. HfN film deposited by mfMS showed a smoother and denser microstructure as the frequency increased, whereas the film deposited by dcMS showed a rough and sloppy microstructure. A single δ-HfN phase was observed in the HfN film made by mfMS with a pulse frequency of 30 kHz, but mixed δ-HfN and HfN0·4 phases were observed in the HfN film made by dcMS. The mechanical properties of HfN film made by mfMS were improved compared to film made by dcMS.

신.구 두 고사 평가치 변환에 의한 진분포와 모수 추정에 관한 연구

  • Hong Seok Gang
    • The Mathematical Education
    • /
    • v.29 no.2
    • /
    • pp.79-93
    • /
    • 1990
  • In this thesis the following studies have been tried: 1. To estimate reliability and validity of the items of scholastic achievment tests that had been tested by the evaluation service centers. 2. To smooth the sample frequency distribution of observed scores and to estimate the frequency distribution of observed scores approximating to the Negative Hypergeometric Distribution.

  • PDF

Determination of Polarization Resistance by Harmonic Current Measurements (조화 전류 측정에 의한 분극 저항 평가)

  • Kim, Jong Jip;Yu, Mi Young
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.247-256
    • /
    • 2012
  • Harmonic current was measured for a dummy cell with various values of resistance, and the procedure developed through the measurements was applied to the investigation of effects of the amplitude of applied frequency and applied potential on the harmonic current of a stainless steel and a carbon steel in chloride containing solutions. From the measurements of harmonic current in the dummy cell, the optimum values of applied frequency and applied potential in harmonic current measurements were found to be 1 mHz and 20 mV (or lower), respectively. Increase in harmonic current with applied frequency was observed in the case where the level of harmonic current is low as in a stainless steel. Decrease in polarization resistance was also noted in this corrosion system with either increasing applied frequency or decreasing applied potential. However, no obvious effects of applied frequency was observed on harmonic current and polarization resistance in a carbon steel in which the level of harmonic current is high.