• Title/Summary/Keyword: Oblique condition

Search Result 149, Processing Time 0.03 seconds

The Effects of Different Surface Level on Muscle activity of the Upper Body and Exercise Intensity during Mountain Climbing Exercise (지면에서의 마운틴 클라이밍 운동 시 상체의 위치 변화가 운동 강도와 근활성도에 미치는 영향)

  • Park, Jun-Ho;Jung, Jae-Hu;Kim, Jong-Geun;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.1
    • /
    • pp.72-78
    • /
    • 2021
  • Objective: The purpose of this study was to investigate relations and effectiveness about mountain climbling exercise with different level of support surfaces by analyzing heart rate and EMG data. A total of 10 male college students with no musculoskeltal disorder were recruited for this study. Method: The biomechanical analysis was performed using heart rate monitor (Polar V800, Polar Electro Oy, Finland), step-box, exercise mat, and EMG device (QEMG8, Laxtha Inc. Korea, sampling frequency = 1,024 Hz, gain = 1,000, input impedance > 1012 Ω, CMRR > 100 dB). In this research, step-box were used to create different surface levels on the upper body (flat surface, 10% of subject's height, 20% of subject's height, and 30% of subject's hight). Based on these different conditions, data was collected by performing mountain climbing exercise during 30 seconds. Subjects were given 5 minutes of break to prevent muscular fatigue after each exercise. For each dependent variable, a one-way analysis of variance with repeated measures was conducted to find significant differences and Bonferroni post-hoc test was performed. Results: The results of this study showed that exercise intensity was reduced statistically as increased surface level on the upper body. Muscle activity of the upper rectus abdominis and biceps femoris for 30% of surface level was significantly higher than the corresponding values for flat surface. However, the opposite was found in the rectus femoris. In general, muscle activity of the lower rectus abdominis, erector spinae, external oblique abdominis, and gluteus maximus increased when surface level increased, but the differences were not significant. Conclusion: As a result, the increase in surface level of the body would change muscle activity of the upper body, indicating that different surface level of the upper body may cause significant effect on particular muscles to be more active during mountain climbing exercise. Based on results of this study, it is suggested to set up an appropriate surface level to target particular muscle to expect an effective training. It is also important to set adequate surface levels to create an effective training condition for preventing exercise injuries.

Fracture Resistance of Incisal Tooth Fragment reattached with different Materials and Preparation (레진재료와 치아형성 방법에 따른 파절편 재부착치아의 파절저항성)

  • Kim, Jongsung;Kim, Gimin;Lee, Jaesik;Kim, Hyunjung;Nam, Soonhyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.104-112
    • /
    • 2022
  • The purpose of this study is to analyze the fracture resistance of reattached tooth according to the resin materials and tooth preparation type under physiological conditions. Uncomplicated crown fracture in the oblique direction was reproduced on the extracted 64 anterior teeth. Depending on the composite resin material, reattachment was performed using a flowable resin and a packable resin. Depending on retentive forms, reattachment was performed using simple reattachment, 1.0 mm × 1.0 mm labial chamfer bevel, 1.0 mm × 1.0 mm lingual chamfer bevel and 1.0 mm × 1.0 mm circumferential bevel. A load was applied to the palatal surface of the tooth using a universal testing machine at an angle of 125 degree, which is the interincisal angle of normal children. Under the masticatory pressure condition, fracture resistance of lingual chamfer groups was 28.28 ± 7.41 MPa and 27.54 ± 4.45 MPa, which was significantly higher than those of simple reattachment groups, 17.21 ± 5.87 MPa and 20.10 ± 6.00 MPa, in both flowable and packable resin groups. When considering the lingual force similar to masticatory pressure, the fragment retention was significantly improved when the lingual chamfer was formed compared to the simple reattachment. Clinicians may consider the design of the lingual chamfer in order to improve fracture resistance to masticatory pressure during fragment reattachment.

Hippocampal Sclerosis: Correlation of MR Imaging Findings with Surgical Outcome

  • Yoon Hee Kim;Kee-Hyun Chang;Sun-Won Park;Young Whan Koh;Sang Hyun Lee;In Kyu Yu;Moon Hee Han;Sang Kun Lee;Chun-Kee Chung
    • Korean Journal of Radiology
    • /
    • v.2 no.2
    • /
    • pp.63-67
    • /
    • 2001
  • Objective: Atrophy and a high T2 signal of the hippocampus are known to be the principal MR imaging findings of hippocampal sclerosis. The purpose of this study was to determine whether or not individual MRI findings correlate with surgical outcome in patients with this condition. Materials and Methods: Preoperative MR imaging findings in 57 consecutive patients with pathologically-proven hippocampal sclerosis who underwent anterior temporal lobectomy and were followed-up for 24 months or more were retrospectively reviewed, and the results were compared with the postsurgical outcome (Engel classification). The MR images included routine sagittal T1-weighted and axial T2-weighted spin-echo images, and oblique coronal T1-weighted 3D gradient-echo and T2-weighted 2D fast spin-echo images obtained on either a 1.5 T or 1.0 T unit. The images were visually evaluated by two neuroradiologists blinded to the outcome; their focus was the presence or absence of atrophy and a high T2 hippocampal signal. Results: Hippocampal atrophy was seen in 96% of cases (55/57) [100% (53/53) of the good outcome group (Engel class I and II), and 50% (2/4) of the poor outcome group (class III and IV)]. A high T2 hippocampal signal was seen in 61% of cases (35/57) [62% (33/53) of the good outcome group and 50% (2/4) of the poor outcome group]. All 35 patients with a high T2 signal had hippocampal atrophy. 'Normal' hippocampus, as revealed by MR imaging, occurred in 4% of patients (2/57), both of whom showed a poor outcome (Engel class III). The presence or absence of hippocampal atrophy correlated well with surgical outcome (p<0.01). High T2 signal intensity did not, however, significantly correlate with surgical outcome (p>0.05). Conclusion: Compared with a high T2 hippocampal signal, hippocampal atrophy is more common and correlates better with surgical outcome. For the prediction of this, it thus appears to be the more useful indicator.

  • PDF

The Effect of Partially Used High Energy Photon on Intensity-modulated Radiation Therapy Plan for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 부분적 고에너지 광자선 사용에 따른 치료계획 평가)

  • Chang, Nam Joon;Seok, Jin Yong;Won, Hui Su;Hong, Joo Wan;Choi, Ji Hun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: A selection of proper energy in treatment planning is very important because of having different dose distribution in body as photon energy. In generally, the low energy photon has been used in intensity-modulated radiation therapy (IMRT) for head and neck (H&N) cancer. The aim of this study was to evaluate the effect of partially used high energy photon at posterior oblique fields on IMRT plan for H&N cancer. Materials and Methods: The study was carried out on 10 patients (nasopharyngeal cancer 5, tonsilar cancer 5) treated with IMRT in Seoul National University Bundang Hospital. CT images were acquired 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). Two plans were generated under same planing objectives, dose volume constraints, and eight fields setting: (1) The low energy plan (LEP) created using 6 MV beam alone, (2) the partially used high energy plan (PHEP) created partially using 15 MV beam at two posterior oblique fields with deeper penetration depths, while 6 MV beam was used at the rest of fields. The plans for LEP and PHEP were compared in terms of coverage, conformity index (CI) and homogeneity index (HI) for planning target volume (PTV). For organs at risk (OARs), $D_{mean}$ and $D_{50%}$ were analyzed on both parotid glands and $D_{max}$, $D_{1%}$ for spinal cord were analyzed. Integral dose (ID) and total monitor unit (MU) were compared as addition parameters. For the comparing dose to normal tissue of posterior neck, the posterior-normal tissue volume (P-NTV) was set on the patients respectively. The $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ for P-NTV were evaluated by using dose volume histogram (DVH). Results: The dose distributions were similar with regard to coverage, CI and HI for PTV between the LEP and PHEP. No evident difference was observed in the spinal cord. However, the $D_{mean}$, $D_{50%}$ for both parotid gland were slightly reduced by 0.6%, 0.7% in PHEP. The ID was reduced by 1.1% in PHEP, and total MU for PHEP was 1.8% lower than that for LEP. In the P-NTV, the $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ of the PHEP were 1.6%, 1.8% and 2.9% lower than those of LEP. Conclusion: Dose to some OARs and a normal tissue, total monitor unit were reduced in IMRT plan with partially used high energy photon. Although these reduction are unclear how have a clinical benefit to patient, application of the partially used high energy photon could improve the overall plan quality of IMRT for head and neck cancer.

  • PDF

The Study on the Correlation of the Ejection Fraction of Multi Gated Blood Pool Scan and Echocardiography According to the Condition of Cardiac Function (심장기능상태의 분류에 따른 게이트심장혈액풀 검사와 심장초음파의 심박출계수 상관관계에 관한 고찰)

  • Lee, Dong Hun;Park, Jang Won;Nam, Ki Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.57-61
    • /
    • 2015
  • Purpose We considered the correlation of Ejection Fraction (EF) which was analyzed by Multi Gated Blood Pool Scan (MUGA) and Echocardiography (ECHO) for the patients who were classified according to the condition of cardiac function. Materials and Methods We analyzed the patients (female 60) who were diagnosed with breast cancer and were examined by both MUGA and ECHO. The 30 patients (age: $58.27{\pm}13.48$) who were analyzed into less than 50% to 70% of EF were categorized as normal group and the other 30 patients (age: $53.70{\pm}8.45$) who were analyzed into less than 50% of EF were categorized as abnormal group. Statistical analysis with SPSS ver. 18 was applied. Results Each of the value of mean and standard deviation of normal group was $66.43{\pm}5.80$ (MUGA), $60.50{\pm}4.93$ (ECHO). There was a significant difference (p<0.001). Each of the value of mean and standard deviation of abnormal group was $41.93{\pm}7.58$ (MUGA), $41.70{\pm}11.49$ (ECHO). There was no significant difference (p>0.001). In the result, all 30 cases of normal group showed the same reading. 8 out of 30 cases in abnormal group showed inconsistency of the reading. Conclusion We could confirm the correlation of the EF in MUGA and ECHO statistically. There was difference between abnormal groups from the result of reading. If we are aware of the result according to the different cardiac function categorization, MUGA and ECHO can be used as even more accurate interchangeable test.

  • PDF

FEM Analysis of the Effects of Mouth guard material properties on the Head and Brain under Mandibular Impact (구강보호장치의 재료적인 특성이 하악골 충격 시악골 및 두부에 미치는 영향에 관한 유한요소분석)

  • Kang, Nam-Hyun;Kim, Hyung-Sub;Woo, Yi-Hyung;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.325-334
    • /
    • 2008
  • Statement of problem & Purpose: The purpose of this study was to investigate the effect of a mouth guard material properties on the skull and brain when they were under impact loads on mandible. Material and methods: Two customized mouth protectors having different material propeerst ieach other were made for a female Korean who had no history of brain trauma, no cerebral diseases, nomal occlusion and natural dentition. The 3D finite element model of human skull and brain scanned by means of computed tomography was constructed. The FEM model of head was composed of 407,825 elements and 82,138 nodes, including skull, brain, maxilla, mandible, articular disc, teeth and mouth guard. The stress concentrations on maxillary teeth, maxilla and skull with two mouth guards were evaluated under oblique impact load of 800N onto mandibular 3 loading points for 0.1sec. And the brain relative displacement was compared in two different mouth guard materials under same condition. Result and Conclusion: The results were as follows; 1. In comparison of von Mises stress on maxillary teeth, a soft mouth guard material had significantly lower stress values on measuring point than a hard mouth protector materials (P < .05). 2. In comparison of von Mises stress on maxilla and skull, A soft mouth protector material had significantly lower stress values on measuring point than a hard mouth protector materials (P < .05). 3. For impact loads on mandible, there were more stress concentrated area on maxilla and skull with hard mouth guard than soft with mouth protector. 4. For impact loads on mandible, brain relative displacement had little relation with mouth guard material properties. In results of this study, soft mouth guard materials were superior to hard mouth guard materials for mandible impact loads for prevention of sports injuries. Although the results of this study were not enough to figure out the roles of needed mouth guard material properties for a human head, we got some knowledge of the pattern about stress concentration and distribution on maxilla and skull for impact loads with soft or hard mouth protector. More studies are needed to substantiate the relationship between the mouth guard materials and sports injuries.

The influence of occlusal loads on stress distribution of cervical composite resin restorations: A three-dimensional finite element study (교합력이 치경부 복합레진 수복물의 응력분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Park, Chan-Seok;Hur, Bock;Kim, Hyeon-Cheol;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.246-257
    • /
    • 2008
  • The purpose of this study was to investigate the influence of various occlusal loading sites and directions on the stress distribution of the cervical composite resin restorations of maxillary second premolar, using 3 dimensional (3D) finite element (FE) analysis. Extracted maxillary second premolar was scanned serially with Micro-CT (SkyScan1072; SkyScan, Aartselaar, Belgium). The 3D images were processed by 3D-DOCTOR (Able Software Co., Lexington, MA, USA). HyperMesh (Altair Engineering. Inc., Troy, USA) and ANSYS (Swanson Analysis Systems. Inc., Houston, USA) was used to mesh and analyze 3D FE model. Notch shaped cavity was filled with hybrid (Z100, 3M Dental Products, St. Paul, MN, USA) or flowable resin (Tetric Flow, Viva dent Ets., FL-9494-Schaan, Liechtenstein) and each restoration was simulated with adhesive layer thickness ($40{\mu}m$). A static load of 200 N was applied on the three points of the buccal incline of the palatal cusp and oriented in $20^{\circ}$ increments, from vertical (long axis of the tooth) to oblique $40^{\circ}$ direction towards the buccal. The maximum principal stresses in the occlusal and cervical cavosurface margin and vertical section of buccal surfaces of notch-shaped class V cavity were analyzed using ANSYS. As the angle of loading direction increased, tensile stress increased. Loading site had little effect on it. Under same loading condition. Tetric Flow showed relatively lower stress than Z100 overall, except both point angles. Loading direction and the elastic modulus of restorative material seem to be important factor on the cervical restoration.

  • PDF

The influence of occlusal loads on stress distribution of cervical composite resin restorations: A three-dimensional finite element study (교합력이 치경부 복합레진 수복물의 응력분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Park, Chan-Seok;Hur, Bock;Kim, Hyeon-Cheol;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.246-257
    • /
    • 2008
  • The purpose of this study was to investigate the influence of various occlusal loading sites and directions on the stress distribution of the cervical composite resin restorations of maxillary second premolar, using 3 dimensional (3D) finite element (FE) analysis. Extracted maxillary second premolar was scanned serially with Micro-CT (SkyScan1072; SkyScan, Aartselaar, Belgium). The 3D images were processed by 3D-DOCTOR (Able Software Co., Lexington, MA, USA). HyperMesh (Altair Engineering, Inc., Troy, USA) and ANSYS (Swanson Analysis Systems, Inc., Houston, USA) was used to mesh and analyze 3D FE model. Notch shaped cavity was filled with hybrid (Z100, 3M Dental Products, St. Paul, MN, USA) or flowable resin (Tetric Flow, Vivadent Ets., FL-9494-Schaan, Liechtenstein) and each restoration was simulated with adhesive layer thickness ($40{\mu}m$). A static load of 200 N was applied on the three points of the buccal incline of the palatal cusp and oriented in $20^{\circ}$ increments, from vertical (long axis of the tooth) to oblique $40^{\circ}$ direction towards the buccal. The maximum principal stresses in the occlusal and cervical cavosurface margin and vertical section of buccal surfaces of notch-shaped class V cavity were analyzed using ANSYS. As the angle of loading direction increased, tensile stress increased. Loading site had little effect on it. Under same loading condition, Tetric Flow showed relatively lower stress than Z100 overall, except both point angles. Loading direction and the elastic modulus of restorative material seem to be important factor on the cervical restoration.

Midterm Results of Bipolar Hemiarthroplasty for Unstable Intertrochanteric Femoral Fractures Using a Type 3C Cementless Stem (불안정성 대퇴골 전자간 골절에 3C형 무시멘트 대퇴 스템을 이용한 고관절 반치환술의 중기 결과)

  • Chung, Woochull;Cho, Hong Man;Kim, Sun do;Park, Jiyeon;Kwon, Kihyun;Lee, Young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.503-510
    • /
    • 2020
  • Purpose: Bipolar hemiarthroplasty is used as an alternative to open reduction and internal fixation for unstable intertrochanteric fractures in elderly patients. Recent advances in medical systems and technologies have resulted in increased survival rates after intertrochanteric fractures of the femur, requiring selection of the appropriate femoral stems considering the mid- to long-term duration of survival. Hemiarthroplasty was performed for unstable intertrochanteric fractures using a double tapered quadrilateral femoral stem (C2 stem), and the clinical and radiological results were evaluated as a five-year follow-up post-surgery. Materials and Methods: From January 2004 to December 2013, 43 patients (43 hips) who underwent hemiarthroplasty with a C2 stem were enrolled in this study. Their mean age was 78.6 years (range, 70-84 years), and the mean follow-up period was 85.4 months (range, 60-96 months). During the follow-up period, clinical parameters, such as the changes in pain, walking ability, and functional status, were examined. Radiologically, changes in the proximal femur, such as osteoporosis and bone resorption of cortical bone, were noted. Complications that occurred during the follow-up period, such as dislocation and prosthetic features, were also reviewed. Results: Initially, the pain was relieved postoperatively, but it increased four years after surgery. The walking ability was reduced by two steps in nine patients after 60 months, and the Harris hip score was reduced significantly postoperatively after two to three years. Radiologically, cortical osteoporosis occurred in 14 patients. Five patients developed cortical bone resorption. Four of them showed nonunion of the trochanteric fracture fragments, and three of them suffered reverse oblique fractures. Conclusion: Careful selection considering the general health condition and remaining lifespan of the patient would be necessary for primary hip hemiarthroplasty using a 3C type cementless femoral stem for unstable intertrochanteric fractures in elderly patients with osteoporosis.