• 제목/요약/키워드: OTF

검색결과 108건 처리시간 0.022초

회절 역문제로 유도한 변조된 Gauss 동함수에 대한 결상계의 OTF (A modulated Gaussian pupil derived from diffraction inverse problem approach and the characteristics of the OTF of the system)

  • 송영란;이민희;이상수
    • 한국광학회지
    • /
    • 제8권2호
    • /
    • pp.95-98
    • /
    • 1997
  • Gauss 초기함수 $e^{-\sigma}$$^{2}$$x^{2}$/에 $e^{-q{\omega}}$$_{0}$ vertical bar x vertical bar를 곱하여 선폭을 더욱 예리하게 하여 역문제(Inverse Problem)로 동함수를 구하고 다시 유한구경에서 결상하는 광파의 회절강도 분포를 구하였다. 이 광학계의 OTF를 구하고 이 값을 변조하지 않은 Gauss 동함수의 (OTF)$_{1.0}$ 의 값과 비교한 결과 변조된 Gauss 동함수의 OTF가 (OTF)$_{1.0}$ 보다 같거나 작음을 보였다. 회절 역문제취급에서 Gauss함수의 선폭을 무조건 예리하게 한다하여 OTF가 향상되지 않는다는 사실을 증명하였다.

  • PDF

Improvement of Functional Properties of Ovotransferrin by Phosphorylation through Dry-heating in the Presence of Pyrophosphate

  • Hayashi, Yoko;Li, Can-Peng;Enomoto, Hirofumi;Ibrahim, Hisham R.;Sugimoto, Yasushi;Aoki, Takayoshi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제21권4호
    • /
    • pp.596-602
    • /
    • 2008
  • Ovotransferrin (OTf) was phosphorylated by dry-heating in the presence of pyrophosphate at pH 4.0 and $85^{\circ}C$ for 1 and 5 d, and the functional properties of phosphorylated OTf (PP-OTf) were investigated. The phosphorus content of OTf increased to 0.91% as a result of phosphorylation and the electrophoretic mobility of PP-OTf also increased. Although the solubility of dry-heated OTf slightly decreased, the decrease was reduced by phosphorylation. The stability against heat-induced insolubilization of OTf was somewhat improved by phosphorylation, but more than 70% of PP-OTf was insolubilized when it was heated at $70^{\circ}C$ for 10 min at pH 7.0. However, heat-induced insolubilization of PP-OTf was reduced when it was heated in the presence of phosphorylated ovalbumin. This may explain the excellent stability of phosphorylated egg white protein against heat-induced insolubilization which was reported previously. The emulsifying property of OTf was also somewhat improved by phosphorylation. The calcium phosphate-solubilizing ability of PP-OTf was enhanced. Although the degree of phosphorylation of OTf by dry-heating in the presence of pyrophosphate was similar to that of ovalbumin, the improvement of properties of PP-OTf was considerably different from those of phosphorylated ovalbumin.

광학설계제원으로부터의 OTF 수치계산 S/W 개발 (Development of Numerical Calculation Software for OTF from Lens Design Data)

  • 이종웅
    • 한국광학회지
    • /
    • 제4권4호
    • /
    • pp.381-389
    • /
    • 1993
  • 광학설계제원으로부터 회저로광학적인 방법으로 OTF를 계산하는 S/W를 개발하고 계산정밀도를 검증 하였다. 개발된 S/W를 이용하여 OTF측정용 표준렌즈에 대한 MTF를 계산하여 본 결과 다른 S/W에서의 계산치 및 실험을 통한 측정치와 잘 일치하고 있음을 확인할 수 있었다.

  • PDF

비축상 OTF의 정밀측정 (Precision Measurement of Off-AXIS OTF)

  • 조현모;이윤우;이회윤;이인원
    • 한국광학회지
    • /
    • 제2권3호
    • /
    • pp.121-126
    • /
    • 1991
  • 칼날주사형 OTF 측정장치를 개선하여 비축상 OTF 측정 정확도를 향상시켰으며 SIRA 연구팀이 개발한 50mm 평면-볼록형 표준렌즈를 사용하여 OTF 측정장치의 성능을 평가하였다. 공간 주파수 0~100 cm / mm 영역에서 표준렌즈의 MTF 측정값은 극소수의 공간 주파수를 제외하고 축상에서 $\pm$0.02, 비축상에서 $\pm$0.03 이내에서 SIRA 측정값과 일치하였으며 PTF 측정값은 SIRA 측정값과 $\pm$$5^{\circ}$이내에서 일치하였다.

  • PDF

Fishtail Edge를 이용한 OTF 측정장치의 자동화 (Automation of an OTF measurement system using a fishtail edge)

  • 김태희;최옥식;조현모;이윤우;이인원
    • 한국광학회지
    • /
    • 제8권1호
    • /
    • pp.7-13
    • /
    • 1997
  • 기존에 제작된 칼날주사형 OTF 측정장치의 물체부와 상분석부를 개선하여 측정을 자동화함으로써 MTF 측정 정확도를 향상시켰다. 여러 가지 크기를 갖는 핀홀과 슬릿들을 물체로 사용하였고, fishtail edge를 상분석부의 수평방향에 45.deg로 부착시킴으로써 radial과 tangential 방향의 MTF를 동시에 측정할 수 있도록 하였다. 또한 상분석부의 스텝핑 모터 구동장치와 측정 컴퓨터 프로그램을 개선하였고, SIRA 그룹의 50nm 표준렌즈를 사용하여 OTF 측정장치의 측정 정확도를 평가하였다.

  • PDF

Improved immune-enhancing activity of egg white protein ovotransferrin after enzyme hydrolysis

  • Lee, Jae Hoon;Kim, Hyeon Joong;Ahn, Dong Uk;Paik, Hyun-Dong
    • Journal of Animal Science and Technology
    • /
    • 제63권5호
    • /
    • pp.1159-1168
    • /
    • 2021
  • Ovotransferrin (OTF), an egg protein known as transferrin family protein, possess strong antimicrobial and antioxidant activity. This is because OTF has two iron binding sites, so it has a strong metal chelating ability. The present study aimed to evaluate the improved immune-enhancing activities of OTF hydrolysates produced using bromelain, pancreatin, and papain. The effects of OTF hydrolysates on the production and secretion of pro-inflammatory mediators in RAW 264.7 macrophages were confirmed. The production of nitric oxide (NO) was evaluated using Griess reagent and the expression of inducible nitric oxide synthase (iNOS) were evaluated using quantitative real-time polymerase chain reaction (PCR). And the production of pro-inflammatory cytokines (tumor necrosis factor [TNF]-α and interleukin [IL]-6) and the phagocytic activity of macrophages were evaluated using an ELISA assay and neutral red uptake assay, respectively. All OTF hydrolysates enhanced NO production by increasing iNOS mRNA expression. Treating RAW 264.7 macrophages with OTF hydrolysates increased the production of pro-inflammatory cytokines and the phagocytic activity. The production of NO and pro-inflammatory cytokines induced by OTF hydrolysates was inhibited by the addition of specific mitogen-activated protein kinase (MAPK) inhibitors. In conclusion, results indicated that all OTF hydrolysates activated RAW 264.7 macrophages by activating MAPK signaling pathway.

In Vitro Immune-Enhancing Activity of Ovotransferrin from Egg White via MAPK Signaling Pathways in RAW 264.7 Macrophages

  • Lee, Jae Hoon;Ahn, Dong Uk;Paik, Hyun-Dong
    • 한국축산식품학회지
    • /
    • 제38권6호
    • /
    • pp.1226-1236
    • /
    • 2018
  • Ovotransferrin (OTF) is a well-known protein of the transferrin family with strong iron chelating activity, resulting in its antimicrobial activity. Furthermore, OTF is known to have antioxidant, anticancer, and antihypertensive activities. However, there have been few studies about the immune-enhancing activity of OTF. In current study, we investigated the immune-enhancing activity of OTF using the murine macrophage cells in vitro. The effect of OTF on production of pro-inflammatory mediators and cytokines were determined using Griess assay and quantitative real-time PCR. Using Neutral Red uptake assay, we confirmed the effect of OTF on phagocytic activity of macrophages. Ovotransferrin significantly increased the production of nitric oxide (NO) and secretion of inducible nitric oxide synthase (iNOS) mRNA with no cytotoxic activity. Ovotransferrin (2 mg/mL) stimulated NO production up to $31.9{\pm}3.5{\mu}M$. Ovotransferrin significantly increased the mRNA expression levels of pro-inflammatory cytokines which are tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$), Interleukin-$1{\beta}$ (IL-$1{\beta}$), and IL-6: OTF (2 mg/mL) treatment increased the secretion of mRNA for TNF-${\alpha}$, IL-$1{\beta}$, and IL-6 by 22.20-, 37.91-, and 6.17-fold of the negative control, respectively. The phagocytic activity of macrophages was also increased by OTF treatment significantly compared with negative control. Also, OTF treatment increased phosphorylation level of MAPK signaling pathways. These results indicated that OTF has immune-enhancing activity by activating RAW 264.7 macrophages via MAPK pathways.

카메라 렌즈 평가용으로 제작된 nodal slide식 실시간 OTF 측정 장치 (Real-time epical transfer function measuring system with on- and off-axis nodal slide bench type for evaluating the camera lens)

  • 이지영;송종섭;조재흥;장수;임천석;이윤우;이인원
    • 한국광학회지
    • /
    • 제13권2호
    • /
    • pp.92-97
    • /
    • 2002
  • 초측정 할 수 있는 nodal slide식 실시간 OTF 측정 장치를 제작하였다. 비축 물체를 측정하기 위하여 nodal slide와 T-bar를 사용하고, 실시간 측정을 위하여 화소 간격이 가로 9.9$\mu\textrm{m}$와 세로 9.6$\mu\textrm{m}$인 2차원 CCD(charge coupled device)를 사용하며, 초점 길이 300mm의 시준 렌즈를 사용하여 장치를 소형화하였다. 그리고 F/8, 초점 길이 50 mm인 SIRA사의 표준 렌즈를 이용하여 측정 장치의 정확도를 평가하고 보정하였다. 본 장치의 신뢰도를 위하여 시야각이 10.6$^{\circ}$이고, 초점 길이가 25.0mm인 CCTV & VIDEO 렌즈(JAPAN, AVENIR-SE 2514)의 MTF를 측정하여 카메라 벤취(bench)형 OTF측정 장치로부터 구한 MTF 값들과 상호 비교한 결과 대부분의 공간주파수에서 4% 이내로 일치하였다.

디지털 카메라 평가용 OTF 측정 장치 개발 (Development of OTF measurement system for evaluation of digital camera)

  • 송종섭;이윤우;조현모;조재흥;장수;박상기;김영준;민운식
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 제11회 정기총회 및 00년 동계학술발표회 논문집
    • /
    • pp.202-203
    • /
    • 2000
  • 광학 렌즈계의 성능 평가를 위한 OTF(Optical Transfer Function) 측정 방법은 Hopkins$^{(1)}$ 에 의해 기본 이론이 확립된 이래 세계 각국에서 활발하게 연구되어 왔으며, 가장 합리적이고 신뢰도가 높은 평가방법으로 인정되고 있다. OTF 측정 방법은 간섭계를 이용하는 측정 방법$^{(2)}$ 과 광학계에 의해 맺혀진 상을 주사 해석하는 방법$^{(3)}$ 으로 대별될 수 있으며, 세계적으로 20여가지 이상의 측정 장치가 개발되었다. 현재 세계 각국은 다양한 형태의 OTF 측정 장치를 보유하고 있으며, OTF의 정확도를 비교 검토하는 연구가 활발해져서 측정 표준을 확립하였고,$^{(4)}$ 국제적인 측정 비교 오차를 0.02 이하로 줄일 수 있게 되었다.$^{(5)}$ 특히 선진국에서는 측정 장치들 간의 상호 비교를 위해 표준 렌즈를 설계, 제작하였고, 이러한 표준 렌즈를 적절한 측정 조건하에서 측정 오차의 원인과 측정 정확도를 평가하는데 사용하였다. (중략)

  • PDF