• Title/Summary/Keyword: OSS

Search Result 229, Processing Time 0.027 seconds

The Analysis of surface free energy of RDX/EVA from contact angle measurements (접촉각 측정에 의한 RDX/EVA의 표면 에너지 해석)

  • 심정섭;김현수;이근득
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.219-230
    • /
    • 2000
  • Plastic bonded explosive(PBX) is mainly composed of the nitramine explosives, RDX, HMX, and polymer binders. When the adhesion between nitramine crystals and binder is not particularly strong and can be failed under stress, dewetting occurs rather suddenly and this leads to a significant drop in tensile strength of explosives. Mechnical property of plastic bonded explosive depends on the surface characteristics of filler and binder. In order to design for better adhesion, an understanding of the surface properties of explosive and binder is essential. In this study, 2 kinds of RDX and 4 kinds of ethylene vinyl acetate copolymers are selected, since they are widely used in many plastic bonded explosives. The technical objective of this investigation is to calculate for the surface free energy of RDX and EVA using theory of Fowkes, van Oss, Neumann approaches and Kaelble equation and to predict the interaction between filler and binder from their surface free energies.

  • PDF

Posbist Reliability Analysis of Typical Systems

  • Huang, Hong-Zhong;Tong, X.;He, L.P.
    • International Journal of Reliability and Applications
    • /
    • v.8 no.2
    • /
    • pp.137-151
    • /
    • 2007
  • Posbist reliability of typical systems is preliminarily discussed in Cai (1991). In this paper, we focus on the posbist reliability analysis of some typical systems in depth. First, the lifetime of the system is dealt as a fuzzy variable defined on the possibility space (U, ${\phi}$, $P_{oss}$) and the universe of discourse is expanded from (0, $+{\infty}$) to ($-{\infty},\;+{\infty}$). Then, a concrete possibility distribution function of the fuzzy variable is given, i.e., a Gaussian fuzzy variable. Finally, posbist reliability of typical systems (series, parallel, series-parallel, parallel-series, cold redundant system) is deduced. The expansion makes the proofs of some theorems straightforward and allows us to easily obtain the posbist reliability of typical systems. To illustrate the method a numerical example is given.

  • PDF

Methodological Study for Recycle of Chemical Mechanical Polishing Slurry (슬러리 Modification 에 대한 연구)

  • Park, Sung-Woo;Seo, Yong-Jin;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.567-568
    • /
    • 2006
  • To investigate the recycle possibility of slurry for the oxide-chemical mechanical polishing (oxide-CMP) application, three kinds of retreated methods were introduced as follows: First, the effects on the addition of silica abrasives and the diluted silica slurry (DSS) on CMP performances were investigated. Second, the characteristics of mixed abrasive slurry (MAS) using non-annealed and annealed alumina ($Al_2O_3$) powder as an abrasive added within DSS were evaluated to achieve the improvement of removal rates (RRs) and within-wafer non-uniformity (WIWNU%). Third, the oxide-CMP wastewater was examined in order to evaluate the possible ways of reusing it. And then, we have discussed the CMP characteristics of silica slurry retreated by mixing of original slurry and used slurry (MOS).

  • PDF

A Study on the Utilization of the selection indicator for the introduction of reliable OSS(Open Source Software) (신뢰성 있는 공개SW 도입을 위한 선정지표 활용방안에 관한 연구)

  • Cho, Dong-Hyung;Park, Sung-Ho;Kim, Tae-Yeol;Yang, Yu-Kil
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.722-725
    • /
    • 2012
  • 최근 이슈가 되고 있는 클라우드 컴퓨팅, 빅데이터, 모바일 등 다양한 분야에서 공개SW 기반 시스템을 도입하여 적용하는 사례가 증가하고 있으나, 수많은 공개SW 중 신뢰성 있는 솔루션을 선택하는 것은 많은 시간과 비용이 발생한다. 이에 공개SW 도입 시 고려해야하는 항목을 도출하여 선정지표를 개발하였으며, 실제 공개SW 도입을 위한 조사 및 선정 단계에서 선정지표를 활용하여 업무 적합성, 성숙도 등을 고려한 최적의 공개SW 선정할 수 있는 기준을 제공하고자한다. 또한 선정지표를 활용하여 WEB, WAS, DB 등 공개SW 솔루션에 대한 평가 사례를 살펴보고, 향후 선정지표를 활용할 수 있는 방안을 제안한다.

Fisher Information and the Kullback-Leibler Distance in Concomitants of Generalized Order Statistics Under Iterated FGM family

  • Barakat, Haroon Mohammed;Husseiny, Islam Abdullah
    • Kyungpook Mathematical Journal
    • /
    • v.62 no.2
    • /
    • pp.389-405
    • /
    • 2022
  • We study the Fisher Information (FI) of m-generalized order statistics (m-GOSs) and their concomitants about the shape-parameter vector of the Iterated Farlie-Gumbel-Morgenstern (IFGM) bivariate distribution. We carry out a computational study and show how the FI matrix (FIM) helps in finding information contained in singly or multiply censored bivariate samples from the IFGM. We also run numerical computations about the FIM for the sub-models of order statistics (OSs) and sequential order statistics (SOSs). We evaluate FI about the mean and the shape-parameter of exponential and power distributions, respectively. Finally, we investigate the Kullback-Leibler distance in concomitants of m-GOSs.

Enhancing Kernel Module Security Using WebAssembly (웹어셈블리를 활용한 커널 모듈 보안성 강화)

  • Hajeong Lim;Hojoon Lee
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.2
    • /
    • pp.337-344
    • /
    • 2023
  • Modern OSs, including Linux, show high scalability by adopting a monolithic kernel design, but have weak security because they share all memory space. This study presents a kernel module that are isolated inside the kernel using WebAssembly. WebAssembly provides a high-performance virtual machine by defining a low-level instruction set while guaranteeing memory safety. In this paper, the WebAssembly execution environment is implemented inside the kernel, allowing developers to control the operation of kernel modules and achieving higher security.

PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY FIXED PROSTHESES WITH RIGID OF NONRIGID CONNECTION BETWEEN NATURAL TOOTH AND OSSEOINTEGRATED IMPLANT (골육착성 보철 치료시 임플랜트와 자연 지대치와의 연결 방법에 따른 관탄성 응력 분석)

  • Kim, Young-Il;Chung, Chae-Heon;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.271-300
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of connection modality between implant and tooth in the superstrcture. This investigation evaluated the stress patterns in a photoelastic model produced by three different types of dental implants such as Branemark, Steri-Oss, IMZ and resin tooth using the techniques of quasi three dimensional photoelasticity. The teeth-supported bridge had a first molar pontic supported by second premolar and second molar as a control group. The implant and toothsupported bridge had a first molar pontic supported by second premolar and implant posterior retainer as an experimental group. Prostheses were mechanically connected to an adjacent second premolar by the rigid of nonrigid connection, Nonrigid connection used an attachment placed between the tooth-supported and fixture-supported component. The female(keyway) of attachment was placed on the distal end of the retainer supported by the tooth ; the male(Key) of attachment connected to the osseointegrated bridge was engaged into the keyway. All prostheses were casted in the same nonprecious alloy and were cemented and screwed on their respective abutments and implants. 16㎏ of vertical loads on central fossae of second premolar, first molar pontic, implant of second molar were applied respectively and 6.5㎏ of inclined load on middle buccal surface of first molar pontic was applied. The results were as follows : 1. Under the vertical load on the central fossa of first mloar pontic, the stress developed at the apex of tooth of implat was more uniformly distributed in the case of nonrigid connection than in the case of rigid connection. 2. Under the vertical load on the central fossa of first molar pontic, the stress developed around the cervical area of tooth of implant was larger in the case of rigid connection than in the case of nonrigid connection because the bending moment was more occured in the case of rigid connection than in the case of nonrigid connection. 3. Stress was more restricted to the loaded side of nonrigid connection than to that of rigid connection 4. Under the inclined load. The set screw loosening of implant was more easily occured in the case of nonrigid connection than in the case of rigid connection due to torque moment. 5. In the case of Branemark implant, the stress concentration in second premolar was larger and the stress developed around the cervical area of implant was lower than any other cases under the vertical load, because Branemark implant with the flexible gold screw was showed in incline toward second premolar by a bending moment. 6. The stress developed around the apex of tooth or implant was more uniformly distributed in the case of Steri-Oss implant with stiff screw than in the case of Branemark implant under the vertical load. But, the stress developed around the cervical area of the Steri-Oss implant was larger than that of any other implants because bending moment was occured by vertical migration of second premolar. 7. The stress distribution in the case of IMZ implant was similar to the case of natural teeth under small vertical load. But, the residual stress around the implant was showed to occurdue to deformation of IMC and sinking of screw under larger vertical load.

  • PDF

The effect of calcium metaphosphate bone graft materials on bone regeneration (생분해성 Calcium Metaphosphate골이식재의 골조직재생효과에 관한 연구)

  • Chae, Han-seung;Lee, Yong-Moo;Yang, Seung-Min;Chun, Sung-Soo;Kim, Suk-Young;Ku, Young;Choung, Chong-Pyoung;Han, Soo-Boo;Choi, Sang-Mook;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.1
    • /
    • pp.13-26
    • /
    • 2003
  • Periodontal regeneration therapy with bone-substituting materials has gained favorable clinical efficacy by enhancing osseous regeneration in periodontal bony defect. As bone-substituting materials, bone powder, calcium phosphate ceramic, modified forms of hydroxyapatite, and hard tissue replacement polymer have demonstrated their periodontal bony regenerative potency. Bone-substituting materials should fulfill several requirements such as biocompatibility, osteogenecity, malleability, biodegradability. The purpose of this study was to investigate biocompatibility, osteo-conduction capacity and biodegradability of $Na_2O$, $K_2O$ added calcium metaphosphate(CMP). Beta CMP was obtained by thermal treatment of anhydrous $Ca_2(H_2PO_4)_2$. $Na_2O$ and $K_2O$ were added to CMP. The change of weight of pure CMP, $Na_2O$-CMP, and $K_2O$-CMP in Tris-buffer solution and simulated body fluid for 30 days was measured. Twenty four Newzealand white rabbits were used in negative control, positive control(Bio-Oss), pure CMP group, 5% $Na_2$-CMP group, 10% $Na_2O$-CMP goup, and 5% $K_2O$-CMP group. In each group, graft materials were placed in right and left parietal bone defects(diameter 10mm) of rabbit. The animals were sacrificed at 3 months and 6 months after implantation of the graft materials. Degree of biodegradability of $K_2O$ or $Na_2O$ added CMP was greater than that of pure CMP in experimental condition. All experimental sites were healed with no clinical evidence of inflammatory response to all CMP implants. Histologic observations revealed that all CMP grafts were very biocompatible and osseous conductive, and that in $K_2O$-CMP or $Na_2O$-CMP implanted sites, there was biodegradable pattern, and that in site of new bone formation, there was no significant difference between all CMP group and DPBB(Bio-Oss) group. From this result, it was suggested that all experimental CMP group graft materials were able to use as an available bone substitution.

Evaluation of bone substitutes for treatment of peri-implant bone defects: biomechanical, histological, and immunohistochemical analyses in the rabbit tibia

  • dos Santos, Pamela Leticia;de Molon, Rafael Scaf;Queiroz, Thallita Pereira;Okamoto, Roberta;de Souza Faloni, Ana Paula;Gulinelli, Jessica Lemos;Luvizuto, Eloa Rodrigues;Garcia, Idelmo Rangel Junior
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.3
    • /
    • pp.176-196
    • /
    • 2016
  • Purpose: We sought to evaluate the effectiveness of bone substitutes in circumferential periimplant defects created in the rabbit tibia. Methods: Thirty rabbits received 45 implants in their left and right tibia. A circumferential bone defect (6.1 mm in diameter/4 mm depth) was created in each rabbit tibia using a trephine bur. A dental implant ($4.1mm{\times}8.5mm$) was installed after the creation of the defect, providing a 2-mm gap. The bone defect gaps between the implant and the bone were randomly filled according to the following groups: blood clot (CO), particulate Bio-Oss$^{(R)}$ (BI), and Bio-Oss$^{(R)}$ Collagen (BC). Ten animals were euthanized after periods of 15, 30, and 60 days. Biomechanical analysis by means of the removal torque of the implants, as well as histologic and immunohistochemical analyses for protein expression of osteocalcin (OC), Runx2, OPG, RANKL, and TRAP were evaluated. Results: For biomechanics, BC showed a better biological response ($61.00{\pm}15.28Ncm$) than CO ($31.60{\pm}14.38Ncm$) at 30 days. Immunohistochemical analysis showed significantly different OC expression in CO and BC at 15 days, and also between the CO and BI groups, and between the CO and BC groups at 60 days. After 15 days, Runx2 expression was significantly different in the BI group compared to the CO and BC groups. RANKL expression was significantly different in the BI and CO groups and between the BI and BC groups at 15 days, and also between the BI and CO groups at 60 days. OPG expression was significantly higher at 60 days postoperatively in the BI group than the CO group. Conclusions: Collectively, our data indicate that, compared to CO and BI, BC offered better bone healing, which was characterized by greater RUNX2, OC, and OPG immunolabeling, and required greater reversal torque for implant removal. Indeed, along with BI, BC presents promising biomechanical and biological properties supporting its possible use in osteoconductive grafts for filling peri-implant gaps.

A Comparative Study on Automated Container Terminal according to Stevedoring System (자동화 컨테이너 터미널의 하역 시스템에 따른 경제성 비교)

  • Cho, Sungwoo;Won, Seunghwan;Choi, Sanghei
    • Journal of Korea Port Economic Association
    • /
    • v.30 no.3
    • /
    • pp.121-140
    • /
    • 2014
  • The purpose of this study is to identify economic benefits for analyzing the future port and propose an appropriate estimation model. This research has conducted the empirical analysis in order to examine the developed research model. First of all, several existing economic benefits are reviewed and the list of benefits, are able to quantify and characterizable, is selected for the next step. We test the application possibility of the proposed model applying for the three suggestions(AS/RS, OSS, Sky Rail) which are based on "Development of Smart Green Container Terminal Technology." The results of this paper are as follows: Firstly, all of the alternatives are proved economic validation because the values of B/C analysis are over 1.0. Secondly, sensitive analysis is attempted to test unforeseeable circumstances based on the cost increases. The result of the test is identified economic validation as well. Lastly, we convince that the proposed research model in this study is particularly applicable to future container terminal so-called "eco-friendly and fully automated container terminal with high productivity."