• 제목/요약/키워드: OR1200

검색결과 309건 처리시간 0.028초

Effects of Microstructure on Thermoelectric Properties of $FeSi_2$

  • Park, Joon-Young;Song, Tae-Ho;Lee, Hong-Lim;Pai, Chul-Hoon
    • The Korean Journal of Ceramics
    • /
    • 제2권1호
    • /
    • pp.11-18
    • /
    • 1996
  • The variation of electrical conductively and Seebeck coefficient of FeSi2 according to the density of the specimen has been observed over the temperature range 50 to $700^{\circ}C$. A conventional pressureless sintering method with various sintering time (0, 0.5, 1, 5h) at $1190^{\circ}C$ and/or various sintering temperatures(1160, 1175, 1190, $1200^{\circ}C$) for 2 h was carried out to prepare $FeSi_2$ specimens having various densities. The relationship between the electrical conductivity and Seebeck coefficient was investigated after two steps of annealing (at $865^{\circ}C$ and then $800^{\circ}C$ for total 160h) and thermoelectric measurement. The electrical conductivity for the specimens showed a typical tendency of semiconductor, the average activation energy of which in the intrinsic region (above $300^{\circ}C$) was observed approximately as 0.452 eV, and increased slightly with density. On the other hand, the specimen of the lower density showed the higher value of Seebeck coefficient in the intrinsic region. As the temperature fell into the non-degenerate region, the highly densified specimen which had relatively little residual metal phase showed the higher value of Seeback coefficient. The power factor of all specimens showed the optimum value at $200^{\circ}C$. However, the power factor of the specimen of the lower density increased again from $400^{\circ}C$ and that of the higher dense specimen increased from $500^{\circ}C$. The power factor was more affected by Seebeck coefficient than electrical conductivity over all temperature range.

  • PDF

국내 쯔쯔가무시증의 감염자 분포와 유병자수 추정 (Estimation of infection distribution and prevalence number of Tsutsugamushi fever in Korea)

  • 이정희;;박정수
    • Journal of the Korean Data and Information Science Society
    • /
    • 제20권1호
    • /
    • pp.149-158
    • /
    • 2009
  • 쯔쯔가무시증은 가을철 유행성 출혈열 중 80%이상을 차지하는 질병으로 1주에서 2주의 잠복기를 가지는 것으로 알려져 있다. 우리는 그 잠복기간의 확률분포가 감마분포라 가정하고 후향연산식을 이용하여, ${\hat{\mu}}=309.92$$, ${\hat{\sigma}}=14.154$인 정규분포를 따르는 감염자 분포를 추정하였다. 감염자는 10월에 집중적으로 분포하는 것으로 나타났다. 이러한 감염자 분포형태는 발병자 수가 11월동안 급격하게 증가하는 것에 기인한다. 본 연구에서 추정한 감염확률에 의해 미래의 유병자수를 계산한 결과 최대 1200명이었고 이는 매년 증가하는 발병자 수의 경향을 반영하지 못한 한계가 있다. 또한 우리는 전염병 모형으로 잘 알려져 있고 전염발전 단계간의 상호작용을 고려하는 SIRS 모형을 적용해 보았다. 모수는 초기값으로부터 잘 근사되어 수렴하는 값으로 추정하였다.

  • PDF

선도화합물 탐색을 위한 고효율가상탐색 프로그램 개발 (Developing Virtual Screening Program for Lead Identification)

  • Nam, Ky-Youb;Cho, Yong-Kee;Lee, Chang-Joon;Shin, Jae-Hong;Choi, Jung-Won;Gil, Joon-Min;Park, Hark-Soo;Hwang, Il-Sun;No, Kyoung-Tai
    • 한국생물정보학회:학술대회논문집
    • /
    • 한국생물정보시스템생물학회 2004년도 The 3rd Annual Conference for The Korean Society for Bioinformatics Association of Asian Societies for Bioinformatics 2004 Symposium
    • /
    • pp.181-190
    • /
    • 2004
  • The docking and in silico ligand screening procedures can select small sets of lead -like candidates from large libraries of either commercially or synthetically available compounds; however, the vast number of such molecules make the potential size of this task enormous. To accelerate the discovery of drugs to inhibit several targets, we have exploited massively distributed computing to screen compound libraries virtually. The Korea@HOME project was launched in Feb. 2002, and one year later, more than 1200 PC's have been recruited. This has created a 31 -gigaflop machine that has already provided more than 1400 hours of CPU time. It has all owed databases of millions of compounds to be screened against protein targets in a matter of days. Now, the virtual screening software suitable for distributed environments is developed by BMD. It has been evaluated in terms of the accuracy of the scoring function and the search algorithm for the correct binding mode.

  • PDF

Mn-Al계 합금의 열처리에 따른 미세조직 변화와 지기적 특성(제1보) -Mn-Al-Cu 합금을 중심으로- (The Magnetic Characteristics and Microstructure of Mn-A1 System Alloys(1st Report) -Focused on the Mn-A1 Alloys-)

  • 방만규;양현수;곽창섭
    • 한국정밀공학회지
    • /
    • 제5권4호
    • /
    • pp.48-58
    • /
    • 1988
  • This study was undertaken to observe the formation behavior of ferro- magnetic phase in Mn-Al-Cu Alloys. The alloy selected for this investigation was 70% Mn-29% Al-1% Cu. This pre-allyed pig was prepared to the cylinderical castings using an Induction furnace after homogenizing at $1100^{\circ}C$ for 2hr, the specimens were cooled by cooling methods. Subwequent isothermal heat treatments were followed at $550^{\circ}C$ for various periods of time at predetermined(1-1000min). The formation behavior of ferromagnetic phase was investigated by measurements of magnetic properties of the specimens at each stage of heat treatment, and optical microscopic esamination and X-Ray diffraction analyses were also employed. By this basic experimental results, the conclusions are as follows 1) In order to obtain much amount of ferromagnetic phase, the optimum average cooling rate was about 7.35-$16.4^{\circ}C$/sec($1100^{\circ}C$-$600^{\circ}C$). 2) We verified the decomposition of {\tau} phase to {\beta} -Mn and {\gamma} , as the specimens were homogenized at $1100^{\circ}C$ for 12hr, then heat-treased at $550^{\circ}C$ for 1-1000min. 3) A condition of optimum heat treatments in Mn-Al-Cu permanent mag-netic alloys showed that after homogenizing at $1100^{\circ}C$ for 2hr, the speciments were cooled in air or furnace(A) and subsequent heat treatments at $550^{\circ}C$ for 1-30min. The maximum magnetic properties were measured as follows: Air cooling; Br=1200(Gause), bHc=100(oe), (BH)max=0.07(MGOe) Furnace cooling(A);Br=950(Gauss), bhe=80(Oe), (BH)max=0.05(MGOe)

  • PDF

Change in Kinetics and Kinematics during 1-Footed Drop Landing with an Increase in Upper Body Weight

  • Lee, Jin-Taek;David, O'Sullivan
    • 한국운동역학회지
    • /
    • 제21권1호
    • /
    • pp.1-7
    • /
    • 2011
  • The purpose of this study was to investigate changes in kinetic and kinematic variables associated with an increase in upper body weight. Eighteen healthy male university students($175.96{\pm}4.19\;cm$, $70.79{\pm}8.26\;kg$) participated. Eight motion analysis cameras(Qualysis Oqus 500) and 2 force AMTI platforms(Advanced Mechanical Technologies Inc. OR6-7, US) were used to record motion and forces during the drop landing at a frequency of 120 Hz and 1200 Hz, respectively. QTM software(Qualisys Track Manager) was used to record the data, and the variables were analyzed with Visual 3D and Matlab 2009. For the drop landing, a box of $4{\times}2{\times}0.46\;m$ was constructed from wood. Knee and ankle maximum flexion angle, knee flexion angle, knee and ankle angle at landing, time for maximum ankle flexion after landing, and time for maximum knee flexion after landing were calculated. There was a significant change in the time for maximum and minimum ground force reaction and the time for maximum dorsal flexion after landing(p<.05) with increasing weight. There was no significant change for the hip, knee, and ankle ROM, whereas there was an increase in the angle ROM as the weight increased, in the order of ankle, knee, and hip ROM. This result shows that the ankle joint ROM increased with increasing weight for shock attenuation during the drop landing. There was a trend for greater ankle ROM than knee ROM, but there was no clear change in the ROM of the hip joint with increasing weight. In conclusion, this study shows the importance of ankle joint flexibility and strength for safe drop landing.

MONITORING OF GAMMA-RAY BRIGHT AGN: THE MULTI-FREQUENCY POLARIZATION OF THE FLARING BLAZAR 3C 279

  • KANG, SINCHEOL;LEE, SANG-SUNG;BYUN, DO-YOUNG
    • 천문학회지
    • /
    • 제48권5호
    • /
    • pp.257-265
    • /
    • 2015
  • We present results of long-term multi-wavelength polarization observations of the powerful blazar 3C 279 after its γ-ray flare on 2013 December 20. We followed up this flare with single-dish polarization observations using two 21-m telescopes of the Korean VLBI Network. Observations carried out weekly from 2013 December 25 to 2015 January 11, at 22 GHz, 43 GHz, 86 GHz simultaneously, as part of the Monitoring Of GAmma-ray Bright AGN (MOGABA) program. We measured 3C 279 total flux densities of 22–34 Jy at 22 GHz, 15–28 Jy (43 GHz), and 10–21 Jy (86 GHz), showing mild variability of ≤ 50 % over the period of our observations. The spectral index between 22 GHz and 86 GHz ranged from −0.13 to −0.36. Linear polarization angles were 27°–38°, 30°–42°, and 33°–50° at 22 GHz, 43 GHz, and 86 GHz, respectively. The degree of linear polarization was in the range of 6–12 %, and slightly decreased with time at all frequencies. We investigated Faraday rotation and depolarization of the polarized emission at 22–86 GHz, and found Faraday rotation measures (RM) of −300 to −1200 rad m−2 between 22 GHz and 43 GHz, and −800 to −5100 rad m−2 between 43 GHz and 86 GHz. The RM values follow a power law with a mean power law index a of 2.2, implying that the polarized emission at these frequencies travels through a Faraday screen in or near the jet. We conclude that the regions emitting polarized radio emission may be different from the region responsible for the 2013 December γ-ray flare and are maintained by the dominant magnetic field perpendicular to the direction of the radio jet at milliarcsecond scales.

BaO 과잉량에 따른 BaTiO3의 전기전도도 (Electrical Conductivity Revisited in Excess BaO into BaTiO3)

  • 여홍구;국민호;김명호;송태권;배동식;박태곤;이순일
    • 한국세라믹학회지
    • /
    • 제42권5호
    • /
    • pp.308-313
    • /
    • 2005
  • In this study the electrical conductivity of excess BaO in $BaTiO_3$ was measured to investigate the relationship between defects and solubility in the temperature range of $900^{\circ}C$ to $1300^{\circ}C$ under various oxygen partial pressure. First of all, quenched $BaTiO_3$ powders of various Ba/Ti ratios were analysed by X-ray diffraction to confirm whether second phase is formed or not. As the results, we observed the solubility of BaO in the temperature range of $1200^{\circ}C$ to $1400^{\circ}C$, and it was also found that the conductivity minima move to lower $PO_2$ with increasing excess BaO within solubility limit.

도시·환경분석을 위한 센서스와 수치지도의 통합에 관한 연구 (A Study of the Census, Digital Maps, and GIS Applications of the Census Data for Urban and Environmental Analysis)

  • 구자문
    • 한국지리정보학회지
    • /
    • 제1권1호
    • /
    • pp.39-51
    • /
    • 1998
  • 본 연구의 목적은 센서스자료를 수치지도와 결합하여 도시 환경분석에 활용하기 위하여 이들의 보완 및 활용에 대한 기초연구를 수행하는데 있다. 센서스자료의 보완을 위하여 가구소득과 주택가격을 조사항목에 첨가할 것과 미국의 PUMS와 같은 1~5%의 표본조사를 제안하였으며, 센서스 최소분석단위를 현재의 읍 면 동 단위에서 이를 5~10지역 정도로 세분화한 인구 5,000명 정도를 기준으로한 센서스트랙을 제안하였다. 수치지도의 빠른 제작과 원활한 활용을 위해서는 지자체들이 1:1000 혹은 1:1200 축척 수치지도들을 자체 제작하려고 노력하는 대신에 국립지리원 제작의 1:5000 축척의 수치지도를 기본도로 활용하여 재정상의 부담을 줄이면서 빠르게 TIGER File화 할 것을 제안하였다.

체외 충격파를 이용한 만성 근위부 족저 근막염의 치료 (Extracorporeal Shock Wave Therapy (ESWT) in Patients with Chronic Proximal Plantar Fasciitis)

  • 김병수;이근배;최진;박유복;백룡빈
    • 대한족부족관절학회지
    • /
    • 제10권2호
    • /
    • pp.163-167
    • /
    • 2006
  • Purpose: To evaluate the results of extracorporeal shock wave therapy (ESWT) for patients with chronic proximal plantar fascitis. Materials and Methods: Between April 2005 and April 2006, 35 cases (24 patients) who were followed more than 6 months were evaluated. By $EvoTron^{(R)}$, 2 sessions of ESWT (Group 1: 1200 and Group 2: 1500 shock waves / session of $0.12\;mJ/mm^2$) were performed at 2 weeks interval. The mean age was 40.0 (range, 15-59) years. 13 patients were male and 11 patients were female. Visual analogue scale (VAS) on daily activity and a 100-point scoring system including 70 points for pain and 30 points for function were used. The clinical outcomes were rated as follows: excellent, no pain on daily activity; good, less than 50% of previous VAS; fair, 50-75% of previous VAS; or poor, more than 75% of previous VAS. Excellent and good were graded as satisfactory results. We compare clinical results between groups and evaluate the relationships between clinical results and duration of symptom, fascial thickening and previous steroid injection were evaluated. Results: Overall satisfactory rate were 71.4%. There was no significant difference of clinical results between groups. And there were no significant difference between clinical results and duration of symtom, preoperative fascial thickening and previous steroid injection. Conclusions: ESWT for recalcitrant chronic proximal plantar fascitis is useful treatment method with high patient satisfaction and pain relief, but more long-term study must be needed.

  • PDF

광섬유격자센서와 회전광학커플러를 사용한 새로운 회전축의 토크 측정방법 (Torque Measurement of Rotating Shaft Using Fiber Bragg Grating Sensors and Rotary Optical Coupler)

  • 이종민;황요하
    • 한국소음진동공학회논문집
    • /
    • 제17권12호
    • /
    • pp.1195-1200
    • /
    • 2007
  • Torque of a rotating shaft has been mostly measured by strain gages combined with either a slip ring or telemetry. However, these methods have severe inherent problems like low S/N ratio, high cost, limited number of channels and difficult installation. In this paper, a new method using FBG(fiber bragg grating) sensors and a rotary optical coupler for online non-contact torque monitoring is suggested. FBG sensor can measure both strain and temperature, and has much batter characteristics than those of a strain gage. A rotary optical coupler is a optical connecting device between a rotating shaft and stationary side without any physical contact. It has been devised for transmitting light between a rotating optical fiber and a stationary optical fiber. The proposed method uses this rotary optical coupler to connect FBG sensors on the rotating shaft to instruments at stationary side. And a reference FBG sensor is also applied to compensate the insertion loss change of the rotary optical coupler due to rotation. Three FBG sensors have been fabricated in a single optical fiber. Two FBG sensors are attached on the shaft surface to measure torque and one sensor is installed at the shaft center to compensate the insertion loss change. The torque of a rotating shaft has been successfully measured by the suggested method proving its superior performance potential.