• Title/Summary/Keyword: OP18

Search Result 121, Processing Time 0.026 seconds

Quality changes of dried persimmon based on storage conditions (농가별 저장조건에 따른 건시의 품질 특성 변화)

  • Choi, Ji-Young;Jo, Jeong-Seok;Lee, Hyeon-Jeong;Woo, Jin-Ho;Heo, Su-Hyeon;Bae, Su-In;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.25 no.1
    • /
    • pp.44-51
    • /
    • 2018
  • The purpose of this study is to present the results as basic data for establishing proper storage conditions and distribution conditions of actual farms at point of increasing concern about hygiene and palatabiltiy of consumers to food. In this study, three farmhouses of dried persimmons prepared using different storage conditions were selected in Sangju (Korea). The dried persimmons were stored for 90 days. Changes in temperature and humidity were measured with a temperature and humidity recorder under each storage condition, and physicochemical analysis and sensory evaluation were performed. The average temperatures of farmhouse A, B and C were approximately $-22--23^{\circ}C$, $-19--18^{\circ}C$ and $-25^{\circ}C$ respectively. The humidities of A, B and C were 62-63%, 59-60%, and 66-67%, respectively, and the moisture contents of all farmhouses increased during the storage period, with farmhouse B showing the most rapid increase. Free sugars increased, except for those from farmhouse C. Persimmons from farmhouse B showed the greatest changes in chewiness and hardness. The values of $a^*$ and $b^*$ were significantly decreased in persimmons from farmhouse B, and the color difference value of farmhouse B was dramatically increased. Sensory evaluation showed that the color preference tended to decrease compared with the initial value. Only farmhouse B showed decreased overall acceptability. Moreover, farmhouse B had the highest storage temperature and lowest humidity. Therefore, our results showed that storage at a low temperature and high humidity was important for manufacturing high-quality dried persimmons.

The Spectrum of CT Findings of COVID-19 Pneumonia: Acute Alveolar Insult and Organizing Pneumonia as Different Phases of Lung Injury and Repair (COVID-19 폐렴의 다양한 CT 영상 소견: 급성 폐포 손상과 기질화 폐렴)

  • Yun Su Kim;Ung Rae Kang;Young Hwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.359-370
    • /
    • 2021
  • Purpose To analyze the findings and serial changes in chest CT lesions in 123 symptomatic patients with coronavirus disease 2019 (COVID-19). Materials and Methods From February 19 to April 7, 2020, a total of 123 confirmed COVID-19 patients (male, 44; female, 79; mean age, 59.2 ± 18.6) were enrolled in this retrospective study. A total of 234 CT scans were reviewed for the following patterns: acute alveolar insult (AAI) patterns: ground-glass opacity (GGO), crazy-paving appearance, mixed pattern, and consolidation; organizing pneumonia (OP) patterns: perilobular patterns, band opacity, curvilinear opacity, reversed halo opacity, and small nodular consolidation; resolving patterns: pure GGO, remnant curvilinear, small nodular consolidation, and serial changes of lung abnormalities. We compared the proportions of AAI pattern, OP pattern, or resolving pattern with time progression and analyzed the association between the patterns and disease severity using Pearson chi-square and Fisher's exact test. Results Predominant CT patterns were AAI pattern (87%) in the early hospital period group (0-10 days, after the onset of symptoms), OP pattern (45.7%) in the later hospital period group (after 10 days), and resolving pattern in discharge and follow-up group (47.2% and 84.8%, respectively). The difference in the proportions of predominant CT patterns with time progression was statistically significant (p < 0.001, Pearson's chi-square test). No statistically significant association was observed between the patterns and disease severity (p = 0.055, Fisher's exact test). No fibrous changes in the lesions were observed on follow-up CT scans. Conclusion The serial CT scans of COVID-19 patients showed the spectrum of COVID pneumonia CT manifestations as different phases of lung injury and repair.

Biogeographical Distribution and Diversity of Bacterial Communities in Surface Sediments of the South China Sea

  • Li, Tao;Wang, Peng
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.5
    • /
    • pp.602-613
    • /
    • 2013
  • This paper aims at an investigation of the features of bacterial communities in surface sediments of the South China Sea (SCS). In particular, biogeographical distribution patterns and the phylogenetic diversity of bacteria found in sediments collected from a coral reef platform, a continental slope, and a deep-sea basin were determined. Bacterial diversity was measured by an observation of 16S rRNA genes, and 18 phylogenetic groups were identified in the bacterial clone library. Planctomycetes, Deltaproteobacteria, candidate division OP11, and Alphaproteobacteria made up the majority of the bacteria in the samples, with their mean bacterial clones being 16%, 15%, 12%, and 9%, respectively. By comparison, the bacterial communities found in the SCS surface sediments were significantly different from other previously observed deep-sea bacterial communities. This research also emphasizes the fact that geographical factors have an impact on the biogeographical distribution patterns of bacterial communities. For instance, canonical correspondence analyses illustrated that the percentage of sand weight and water depth are important factors affecting the bacterial community composition. Therefore, this study highlights the importance of adequately determining the relationship between geographical factors and the distribution of bacteria in the world's seas and oceans.

CEPHALOMETRIC ANALYSIS OF MAXILLOFACIAL NORMALS IN KOREAN ADULTS (한국 성인 정상교합자의 악안면 정상치에 관한 두부방사선 계측학적 연구)

  • Lee, Won You;Sohn, Byung Hwa
    • The korean journal of orthodontics
    • /
    • v.14 no.1
    • /
    • pp.135-149
    • /
    • 1984
  • This study was performed to aid for the case analysis and diagnosis of the maxillofacial deformities. A cephalometric analysis was made from 101 subjects over 18 years old, that consisted of 46 males and 55 females with normal occlusion, acceptable profile. The results o f this study were obtained as follows: 1. The tables of normals in adult male and female were made. 2. The angles of SNO were $65.5^{\circ}$ in male and $65.3^{\circ}$ in female and the horizontal linear measurements from 0 to NA(O-NA) were 9.0 mm in male and 8.9 mm in female. 3. The cranial base angles (SN-FH) were $8.2^{\circ}$in male and $10.3^{\circ}$ in female and the mandibular plane angles (OP-HP) were $28.1^{\circ}$ in male and $26.2^{\circ}$ in female. 4. The correlation of (O-NA) to S-O/S-A and S-O/S-N were higher than SNO, and the correlation of (N-A) to SNA and (N-B) were high.

  • PDF

A 10-bit 100Msample/s Pipeline ADC with 70dBc SFDR (SFDR 70dBc의 성능을 제공하는 10비트 100MS/s 파이프라인 ADC 설계)

  • Yeo, Seon-Mi;Moon, Young-Joo;Park, Kyong-Tae;Roh, Hyoung-Hwan;Park, Jun-Seok;Oh, Ha-Ryoung;Seong, Yeong-Rak;Jung, Myeong-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1444-1445
    • /
    • 2008
  • 최근 Wireless Local Area Network(WLAN), Wide-band Code Division Multiple Access(WCDMA), CDMA2000, Bluetooth 등 다양한 모바일 통신 시스템에 대한 수요가 증가하고 있다. 이와 같은 모바일 통신 시스템에는 70dB이상의 SFDR(Spurious Free Dynamic Range)을 가진 ADC(Analog-to-Digital Converter)가 사용된다. 본 논문에서는 모바일 통신 시스템을 위한 SFDR 70dBc의 성능을 제공하는 10비트, 100Msps 파이프라인 ADC를 제안한다. 제안한 ADC는 요구되는 해상도 및 속도 사양을 만족시키기 위해 3단 파이프라인 구조를 채택하였으며, 입력단 SHA(Sample and Hold)회로에는 Nyquist 입력에서도 10비트 이상의 정확도로 신호를 샘플링하기 위해 부트스트래핑 기법 기반의 샘플링 스위치를 적용하였다. residue amplifier 회로에는 전력을 줄이기 위해 8배 residue amplifier 대신 3개의 2배 ressidue amplifier를 사용하였다. ADC의 높은 사양을 만족시키기 위해서는 높은 이득을 가지는 op-amp가 필수적이다. 제안한 ADC 는 0.18um CMOS 공정으로 설계되었으며, 100Msps의 동작 속도에서 70dBc 수준의 SFDR과 60dB 수준의 SNDR(Signal to Noise and Distortion Ratio)을 보여준다.

  • PDF

Left ventricular aneurysm (Two cases report) (좌심실에 발생한 진성심실류 (2례 보고))

  • 이철세
    • Journal of Chest Surgery
    • /
    • v.16 no.2
    • /
    • pp.175-183
    • /
    • 1983
  • Ventricular aneurysm which was first described by John Hunter on 18th century, has been experienced by many surgeons after successful using of cardiopulmonary bypass by Cooley on 1958. According to Gorlin, the definition of ventricular aneyrysm is portion of the ventricle which is not motile at systole (akinesis) or which has paradoxical dilatation at systole(dyskinesis). The ventricular aneurysm is classified to anatomical and functional. The anatomical ventricular aneurysm is devided into true or false again. Average age incidence is ranged from 49 to 60 and male predominance is reported. The cause is ischemic coronary artery disease in almost cases but hypertropoc cardiomyopathy, congenital abscence of myocardium, complication after mitral valvular replacement and trauma may also cause the ventricular aneurysm. Angina pectoris and congestive heart failure are most common clinical manifestations Ventricular tachycardia and systemic embolization are also complained. Using cardiopulmonary bypass, aneurysmectomy alone or combination with coronary artery revasculization are currently done for surgical treatment with steady improvenment of mortality. The first patient was 33 years old man who had true type of ventricular aneurysm on inferior wall the left ventricle near apex with protruded huge organized thrombus. The thromboembolic phenomenon was noted on both lower extremities. Under cardiopulmonary bypass, aneurysmectomy and thrombectomy were done. The aneurysmal orifice was repaired with Teflon buttless suture. The second patient was 30 years old female who had large true type of ventricular aneurysm on inferior wall of the left ventricle. Under cardiopulmonary bypass, aneurysmectomy with repair of aneurysmmal orifice defect by means of double layered Dacron patch was done with reinforce by outer silastic sheet covering. She was discharged from hospoital at post op. 15th day uneventfully.

  • PDF

Control of Odor Emissions Using Biofiltration: A Case Study of Dimethyl Disulfide

  • Kim, Jo-Chun;Bora C. Arpacioglu;Eric R. Allen
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E3
    • /
    • pp.153-163
    • /
    • 2002
  • A laboratory- scale dual-column biofilter system was used to study the biofiltration of dimethyl disulfide (DMDS). The gas flow rate and DMDS concentration to the biofilter were varied to study their effect on the remov-al of dimethyl disulfide. Operating parameters such as pH, temperature, and water content were monitored during the biofilter operation and necessary precautions were taken to keep these parameters within the acceptable limits. It was observed that the removal efficiency of DMDS was optimal at neutral pH values. After five month op-eration, the neutralization of the filter beds with sodium carbonate became necessary for the optimum operation of the biofilters. The microbial population already present in the compost mixtures was found to be adequate in treat-ing DMDS. The compost mixtures were found to be similar in terms of biofiltration efficiency of DMDS. However, pressure drops observed in the first column compost mixture (compost/ peat mulch) was extremely high, making this compost economically not feasible. The second mixture (compost/bark) provided pressure drops within accept-able limits. A minimum residence time of 30 seconds at the optimal operating conditions appeared to be adequate for achieving high removal efficiencies (>90%).

Design of High-Speed Comparators for High-Speed Automatic Test Equipment

  • Yoon, Byunghun;Lim, Shin-Il
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.4
    • /
    • pp.291-296
    • /
    • 2015
  • This paper describes the design of a high-speed comparator for high-speed automatic test equipment (ATE). The normal comparator block, which compares the detected signal from the device under test (DUT) to the reference signal from an internal digital-to-analog converter (DAC), is composed of a rail-to-rail first pre-amplifier, a hysteresis amplifier, and a third pre-amplifier and latch for high-speed operation. The proposed continuous comparator handles high-frequency signals up to 800MHz and a wide range of input signals (0~5V). Also, to compare the differences of both common signals and differential signals between two DUTs, the proposed differential mode comparator exploits one differential difference amplifier (DDA) as a pre-amplifier in the comparator, while a conventional differential comparator uses three op-amps as a pre-amplifier. The chip was implemented with $0.18{\mu}m$ Bipolar CMOS DEMOS (BCDMOS) technology, can compare signal differences of 5mV, and operates in a frequency range up to 800MHz. The chip area is $0.514mm^2$.

Tunable Bandpass 4th Order SC Sigma-delta Modulator with Novel Structure (새로운 구조의 Tunable 4차 SC Bandpass Sigma-Delta 변조기)

  • Kim, Jae-Bung;Yoo, Nam-Hee;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.446-450
    • /
    • 2011
  • Tunable SC(Switched Capacitor) bandpass ${\Sigma}-{\Delta}$(Sigma-Delta) modulator used in wireless system receiver occurs a signal attenuation according to tuning of center frequency in signal bandwidth. In this paper, tunable bandpass 4th order SC bandpass ${\Sigma}-{\Delta}$ modulator with novel structure is proposed for rejection of signal attenuation in signal bandwidth. The existing structure uses a ten variable coefficient values for rejection of signal reduction in the modulator. But the proposed structure only use a two variable coefficient values for rejection of signal attenuation in the modulator. Also, an adder and comparator is replaced with a comparator having 4 inputs in the modulator. Therefore, the existing structure has one more OP-AMP. The purposed modulator was designed in $0.18\;{\mu}m$ CMOS technology. The resolution of the modulator within 310 kHz bandwidth and 40 MHz sampling frequency under 6.67 MHz, 10 MHz and 13.33 MHz intermediate frequency are over 10 bit.

Linearization of CMOS Drive Amplifier with IMD Canceller (IMD 상쇄기를 적용한 CMOS 구동 증폭기 선형화 방법)

  • Kim, Do-Gyun;Hong, Nam-Pyo;Moon, Yon-Tae;Choi, Young-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.999-1003
    • /
    • 2009
  • We have designed and fabricated a linear drive amplifier with a novel intermodulation distortion(IMD) canceller using $0.18{\mu}m$ CMOS process. The drive amplifier with IMD canceller is composed of a cascode main amplifier and an additional common-source IMD canceller. Since the IMD canceller generates IM3($3^{rd}$-order imtermodulation) signal with $180^{\circ}$ phase difference against the IM3 of the cascode main amplifier, the IM3 power is drastically eliminated. As of the measurement results, $OP_{1dB}$, $OIP_3$, and power-add efficiency are 5.5 dBm, 15.5 dBm, and 21%, respectively. Those are 5 dB, 6 dB, and 13.5% enhanced values compared to a conventional cascode drive amplifier. The IMD3 of the drive amplifier with IMD canceller is enhanced more than 10 dB compared to that of the conventional cascode drive amplifier for input power ranges from -22 to -14 dBm.