• Title/Summary/Keyword: OOK Receiver

Search Result 31, Processing Time 0.037 seconds

Design of Multipath Adaptive BISMO-Algorithm in the Underwater Communication (수중 통신시 다중경로 적응 BISMO (Bi-Switch Modulation)알고리즘 설계)

  • Im, Byung-Ook;Shim, Tae-Bo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.7
    • /
    • pp.342-349
    • /
    • 2008
  • Multipath makes clear message transfer difficult in the underwater communication. To solve this problem, we propose a new method producing proper MFSP (Modulation Frequency Shift Period) which could be obtained by calculating time delay caused by different path from a transmitter to a receiver. At the transmitter end, messages were divided according to the size of the MFSP and transmitted accordingly alternating Frequency. At the receiver end, the received messages were demodulated in order to recover the original message by the adaptive BISMO algorithm which is constructed at the algorithm design stage. Adaptive MFSP and estimated BER (Bit Error Rate) were calculated through simulation test.

Wireless Bio-Signal Sensing System Using a Circular Polarized Antenna

  • Kwon Young-Bae;Park Jung-Min;Choe Jung-Hwan;Park Seong-Ook;Ishida Osami
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.3
    • /
    • pp.132-139
    • /
    • 2005
  • Wireless bio-signal sensing system, which is based on the principle of Doppler radar, can measure a respiration and heart rates with a periodic movement of skin and muscle near the heart. Though the sensing monostatic system using a circulator has been studied, this bistatic system can be improved by using a circular polarized antenna which has a high isolation between transmitter and receiver. In this paper, we measured the bio-signal without the direct contact with the person. The design of each system and experimental results are discussed.

Noninvasive Life Signal Detecting Systems and Their Analyses

  • Park, Jung-Min;Park, Dong-Hyuk;Park, Seong-Ook
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.1
    • /
    • pp.45-49
    • /
    • 2003
  • Wireless life signal detecting system is implemented with using the mechanism of Doppler Effect. This system can measure the respiration and heart rates with the periodic movement of skin and muscle near the heart. The system is consisted of antenna, RF transmitter, receiver, and display part. We did use two operating frequencies at 1.9 ㎓ and 10 ㎓. Firstly, the link budget about detecting system is analyzed and the signal detected from the system is compared with electrocardiogram(ECG) of monitor which is using for patient monitoring in hospital. Secondly, the detection of vital sign is also performed according to the different distances, and including behind the wall.

Design and Implementation of Multi-Gigabit Packet Receiver Algorithms based on ECMA Standard (ECMA 표준에 기반한 Multi-Gigabit Packet 수신기 알고리듬 설계 및 구현)

  • Lee, Yong-Wook;Lee, Ji-Yeon;Oh, Wang-Rok
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.119-120
    • /
    • 2008
  • 본 논문에서는 ECMA 표준에 기반한 multi-gigabit packet 수신기를 위한 프레임 검출 방안을 제안한다. ECMA 표준은 60 GHz 대역에서 multi-gigabit 전송률을 달성하기 위하여 버스트 (burst) 송수신 방식을 사용하며 프리앰볼 (preamble)과 데이터 (data)로 이루어진 프레임 (frame)을 통하여 데이터 송수신이 이루어진다. 본 논문에서는 ECMA 표준 중 DBPSK (Differential Binary Phase Shift Keying)와 DQPSK (Differential Quadrature Phase Shift Keying) 그리고 OOK (On-Off Keying) 변조 방식을 지원하는 multi-gigabit 송수신 시스템을 위한 프레임 검출기를 설계하였다. 설계된 프레임 검출기는 동일한 구조 및 동작 방식을 통하여 고려한 모든 변조 방식들을 지원할 수 있을 뿐만 아니라 하드웨어 구현 복잡도가 낮은 장점을 지닌다.

  • PDF

Color Clustered Multiple-input Multiple-output Visible Light Communication

  • Han, Phyu Phyu;Sewaiwar, Atul;Tiwari, Samart V.;Chung, Yeon-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.74-79
    • /
    • 2015
  • A novel color clustered optical RGB multiple-input multiple-output (MIMO) system is presented. As visible light can be divided into three primary regions of red, green and blue, data can be modulated and transmitted separately using these three color clusters. Each color cluster comprised of 30 RGB LEDs is modulated using on-off-keying (OOK), and selection combining is performed at the receiver, producing a diversity effect within that color cluster. The simulations demonstrate that the proposed RGB MIMO VLC system provides high performance via a relatively simple design of MIMO. Moreover, the proposed system ensures sufficient illumination from LEDs and offers extended distance if more LEDs are applied.

A Non-coherent UWB Direct Chaotic Ranging System for Precision Location and Positioning

  • Yang, Wan-Cheol;Lee, Sang-Yub;Lee, Kwang-Du;Kim, Ki-Hwan;Yang, Chang-Soo;Kim, Hak-Sun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.311-315
    • /
    • 2006
  • Precision location and positioning of Asset within a network is an attractive feature with various applications, especially in indoor environments. Such a demand is met by the standard task group, IEEE 802.15.4a. Several methods, that is, pulse, chirp and chaotic communications have been proposed so far to satisfy the requirements of the standard. Among them, ultra wideband direct chaotic communications has advantageous features such as low hardware complexity, low cost, lower power consumption and flexible frequency band plan. In this paper, the feasibility of the ranging system using non-coherent chaotic transceiver is investigated by designing and implementing the system and the performance is proved by conducting location experiments in real indoor environments.

  • PDF

Ultra-Low Power MICS RF Transceiver Design for Wireless Sensor Network (WSN 을 위한 초저전력 MICS RF 송수신기 기술 개요 및 설계 기법)

  • Gyu-won Kim;Yu-jung Kim;Junghwan Han
    • Transactions on Semiconductor Engineering
    • /
    • v.2 no.1
    • /
    • pp.9-16
    • /
    • 2024
  • This paper discusses the design of bio-implanted ultra-low-power MICS RF transceivers for wireless sensor networks. The 400 MHz MICS standard was considered for the implementation of the WBAN wireless sensor system, indirectly minimizing radio propagation losses in the human body and the inference with surrounding networks. This paper includes link budget, various transmission and reception architectures for a system design and ultra-low power transceiver circuit techniques for the implementation of RF transceivers that meet MICS standards.

Development of Polarization-Controllable Active Phased Array Antenna for Receiving Satellite Broadcasting (편파가변 위성 방송 수신용 능동 위상 배열 안테나 개발)

  • Choi, Jin-Young;Lee, Ho-Seon;Kong, Tong-Ook;Chun, Jong-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.5
    • /
    • pp.325-335
    • /
    • 2018
  • We herein present a study on the active phased array antenna for receiving satellite broadcasting that can electrically align its polarization to that of target transmitters in its moving condition or in the Skew angle arrangement of the broadcasting satellite receiver. Hence, we have developed an active phased array structure composed of the self-developed Vivaldi antenna and multifunction core (MFC) chip, receiving RF front end module, and control units. In particular, the new Vivaldi antenna designed in the Ku-band of 10.7 - 14.5 GHz to receive one desired polarization mode such as the horizontal or vertical by means of an MFC chip and other control units that can control the amplitude and phase of each antenna element. The test results verified that cross-polarization property is 20 dB or higher and the primary beam can be scanned clearly at approximately ${\pm}60^{\circ}$.

Shore-to-sea Maritime Visible Light Communication using Color Clustered MIMO (컬러 클러스터 MIMO 기술을 적용한 해상 가시광 통신 시스템)

  • Kim, Hyeong-ji;Chung, Yeon-ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.8
    • /
    • pp.1773-1779
    • /
    • 2015
  • Shore-to-sea visible light communication using color clustered multiple-input and multiple-output (MIMO) is presented. The proposed maritime visible light communication (MVLC) offers a low-cost, high-speed wireless link for shore-to-sea maritime communications. Each color cluster is comprised of 50 red, green and blue (RGB) light emitting diodes (LEDs) and is modulated using on-off-keying (OOK). Selection combining is performed at the receiver, producing diversity effect within that color cluster. In this paper, we employ sea states (wave height, wind speed, etc.) data from both Pierson-Moskowitz and JONSWAP spectrum models under atmospheric turbulence conditions. Based on the simulation model, the maritime link quality is analysed in terms of coverage distance and bit error rate performance. The results show that the proposed system provides an efficient MVLC, while satisfying International Association of Lighthouse Authorities (IALA) requirements for maritime buoyage system and also offering sufficient illumination from high power LEDs.

Utility of FDG PET-CT Scans on Nodal Staging of Squamous Cell Carcinoma in the Oral Cavity and Oropharynx (구강 및 구인두 편평상피암종의 림프절 전이에 대한 PET-CT 영상의 유용성)

  • Joo, Young-Hoon;Sun, Dong-Il;Park, Jun-Ook;Yoo, Ie-Ryung;Kim, Min-Sik
    • Korean Journal of Head & Neck Oncology
    • /
    • v.26 no.1
    • /
    • pp.14-18
    • /
    • 2010
  • Objectives : We evaluated the use of FDG PET/CT for the identification of cervical nodal metastases of SCC of the oral cavity and oropharynx with histological correlation. Material and Methods : We reviewed 46 medical records, from January 2004 to July 2007, of patients who underwent FDG PET/CT and CT/MRI for SCC of the oral cavity and oropharynx before surgery. We recorded the lymph node metastases according to the neck level affected and the system used for the imaging-based nodal classification. Results : The FDG PET/CT had a sensitivity of 75.6% and a specificity of 96.7% ; it had a higher sensitivity than the CT/MRI for identification of cervical metastases on the side of the neck(26/28 vs. 20/28, p=0.031) and at each of the cervical levels(34/45 vs. 26/45, p=0.008). There was a significant difference in the $SUV_{max}$ between the benign and malignant cervical lymph nodes($3.31{\pm}3.23$ vs. $4.22{\pm}2.57$, p=0.028). The receiver-operating-characteristic (ROC) curve analysis for differentiating the benign from the malignant cervical lymph nodes, showed that the area under the curve(AUC) of the FDG PET/CT was 0.775. The cut-off value for the $SUV_{max}$ was 2.23 based on the ROC curve. There was a significant correlation between the $SUV_{max}$ and the size of the cervical lymph nodes(Spearman r=0.353, p=0.048). Conclusion : FDG PET/CT images were more accurate than the CT/MRI images. In addition, the $SUV_{max}$ cut-off values were important for evaluating cervical the cervical nodes in the patients with SCC of the oral cavity and oropharynx.