• 제목/요약/키워드: OMAT

검색결과 34건 처리시간 0.017초

REFLECTANCE-COLOR TRENDS ON THE LUNAR MARE SURFACE

  • Kim, Sungsoo S.;Sim, Chae Kyung
    • 천문학회지
    • /
    • 제55권3호
    • /
    • pp.75-86
    • /
    • 2022
  • The lunar surface progressively darkens and reddens as a result of sputtering from solar wind particles and bombardment of micrometeoroids. The extent of exposure to these space weathering agents is frequently calculated as the location in a diagram of reflectance at 750 nm vs. 950 nm/750 nm color (R-C). Sim & Kim (2018) examined the R-C trends of pixels within ~3,500 craters, and revealed that the length (L) and skewness (s) of R-C trends can be employed as a secondary age or maturity indicator. We broaden this research to general lunar surface areas (3,400 tiles of 0.25° × 0.25° size) in 218 mare basalt units, whose ages have been derived from the size-frequency distribution analysis by Hiesinger et al. (2011). We discover that L and s rise with age until ~3.2 Gyr and reduce rather rapidly afterward, while the optical maturity, OMAT, reduces monotonically with time. We show that in some situations, when not only OMAT but also L and s are incorporated in the estimation utilizing 750 & 950 nm photometry, the age estimation becomes considerably more reliable. We also observed that OMAT and the lunar cratering chronology function (cumulative number of craters larger than a certain diameter as a function of time) have a relatively linear relationship.

Reflectance-Color Trends on the Lunar Mare Surface

  • 김성수;심채경
    • 천문학회보
    • /
    • 제46권2호
    • /
    • pp.48.2-48.2
    • /
    • 2021
  • The lunar surface progressively darkens and reddens as a result of sputtering from solar wind particles and bombardment of micrometeoroids. The extent of exposure to these space weathering agents is frequently calculated as the location in a diagram of reflectance at 750 nm vs. 950 nm/750 nm color (R-C). Sim & Kim (2018) examined the R-C trends of pixels within ~3,500 craters, and revealed that the length (L) and skewness (s) of R-C trends can be employed as a secondary age or maturity indicator. We broaden this research to general lunar surface areas (3,400 tiles of 0.25° × 0.25° size) in 218 mare basalt units, whose ages have been derived from the size-frequency distribution analysis by Hiesinger et al. (2011). We discover that L and s rise with age until ~3.2 Gyr and reduce rather rapidly afterward, while the optical maturity, OMAT, reduces monotonically with time. We show that in some situations, when not only OMAT but also L and s are incorporated in the estimation utilizing 750 & 950 nm photometry, the age estimation becomes considerably more reliable. We also observed that OMAT and the lunar cratering chronology function (cumulative number of craters larger than a certain diameter as a function of time) have a relatively linear relationship.

  • PDF

Maturity of the Crater Rim Walls as a function of the Crater Size

  • SIM, Chae Kyung;Kim, Sungsoo S.;Jeong, Minsup
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.45.3-46
    • /
    • 2015
  • Space weathering agents such as micrometeoroids and solar wind particles continuously age the uppermost regolith of the lunar surface by comminuting as well as darkening and reddening. Among several maturity indices, we investigate median grain size () and optical maturity (OMAT) of the crater rim walls. Crater rim wall is the most immature place among the impact crater features because the vertical mixing process by mass-movement can enhance the gardening of regolith and the supply of immature materials in the deeper layer to the surface. More than 140 simple and complex craters were considered. Both and OMAT values of the inner rim wall initially increase as the crater size increases until ~10-20 km, then decrease. This transition crater size happens to correspond to the transition diameter from simple to complex craters. For larger craters, i.e., complex craters, it is clear that the inner rim wall of the craters formed in recent eras tend to remain fresh and become mature along with time. For the simple crater case, smaller craters are more mature, which is opposite to the case of complex craters. This is thought to be because smaller craters become flattened more quickly, thus have smaller vertical mixing in the regolith due to mass-movement. We will also discuss on the maturity indices of the crater rim walls at high latitudes as a function of the position angle to see the latitude dependence of the space weathering process.

  • PDF

Optical properties study of magnetic anomaly regions at Mare Crisium

  • Lee, Jung-Kyu;Lee, Hyojeong;Baek, Seul-Min;Kim, Khan-Hyuck;Jin, Ho;Hemingway, Doug;Garrick-Bethell, Ian
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.99.1-99.1
    • /
    • 2014
  • 달은 global magnetic fields가 존재하지 않으나, 달 표면에 국지적으로 자기장이 존재하며 이러한 현상의 원인은 계속 연구중이다. 달의 자기이상 현상이 나타나는 지역 중 광학적으로 밝고 어두운 패턴이 관측되는 지역을 Swirl이라한다. Mare Crisium ($17.18^{\circ}N$, $59.1^{\circ}E$)은 표면에 2개의 자기이상 지역과 광학적으로 밝은 지역들이 존재하지만, Swirl로 잘 알려진 Reiner Gamma와 같은 지역의 광학적 밝기와 패턴의 차이가 있다. 이를 위해 본 연구에서는 Lunar Prospector (LP) 위성의 magnetometer (MAG) 자료를 이용하여 자기장 분포에 관한 연구 및 Clementine 위성의 UV/VIS 영상자료를 이용하여 광학적 특성 연구를 진행하였다. LP의 MAG 자료는 Mare Cirisium지역의 22.3 km 고도에서 관측된 744개의 자료를 활용하였으며, Clementine의 영상자료는 750 nm, 950 nm의 반사도에 따른 Optical Maturity (OMAT)를 활용하였다. Mare Crisium의 북쪽지역은 자기이상 현상과 OMAT의 고유특성이 동시에 나타나며 이는 swirl과 유사하다. 특히, Mare Cirisum서쪽에 있는 Proclus crater 잔해 일부가 Mare Crisium의 북쪽지역까지 퍼져있어 이와 관련하여 자기장 존재여부에 따른 광학적 특성의 차이점을 조사하였다. 본 논문에서는 Mare Crisium 지역의 Swirl 진위여부를 추론하며, 본 논문에서 이용한 방법의 유용성에 대하여 검증하고자 한다.

  • PDF

횡방향 자기장이 고에너지 전자선의 선량분포에 미치는 영향 (Effect of Transverse Magnetic Field on Dose Distribution of High Energy Electron Beam)

  • 오영기;김기환;신교철;김진기;김정기;정동혁;조문준;김준상;윤선민;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제18권4호
    • /
    • pp.209-213
    • /
    • 2007
  • 20 MeV 전자선의 팬텀 내에서의 선량분포에 대한 횡방향 자기장 효과를 조사하기 위하여 전자석을 제작하여 자기장 인가 여부에 따른 등선량곡선 및 깊이선량율을 X-OMAT 필름으로 측정하였다. 1.5 Tesla의 자기장중심을 팬텀 표면으로부터 7.5 cm 깊이에 위치시킨 경우 팬텀 표면으로부터 4.5 cm 깊이에서 약 30%의 선량증가를 보이는 등 이론적으로 알려진 결과들과 잘 부합하고 있음을 확인하였다.

  • PDF

Regional Differences of Proteins Expressing in Adipose Depots Isolated from Cows, Steers and Bulls as Identified by a Proteomic Approach

  • Cho, Jin Hyoung;Jeong, Jin Young;Lee, Ra Ham;Park, Mi Na;Kim, Seok-Ho;Park, Seon-Min;Shin, Jae-Cheon;Jeon, Young-Joo;Shim, Jung-Hyun;Choi, Nag-Jin;Seo, Kang Seok;Cho, Young Sik;Kim, MinSeok S.;Ko, Sungho;Seo, Jae-Min;Lee, Seung-Youp;Chae, Jung-Il;Lee, Hyun-Jeong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제29권8호
    • /
    • pp.1197-1206
    • /
    • 2016
  • Adipose tissue in the loin muscle area of beef cattle as a marbling factor is directly associated with beef quality. To elucidate whether properties of proteins involved in depot specific adipose tissue were sex-dependent, we analyzed protein expression of intramuscular adipose tissue (IMAT) and omental adipose tissue (OMAT) from Hanwoo cows, steers, and bulls of Korean native beef cattle by liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based proteomic analysis, quantitative polymerase chain reaction (PCR) and western blot analysis. Two different adipose depots (i.e. intramuscular and omental) were collected from cows (n = 7), steers (n = 7), or bulls (n = 7). LC-MS/MS revealed a total of 55 and 35 proteins in IMAT and OMAT, respectively. Of the 55 proteins identified, 44, 40, and 42 proteins were confirmed to be differentially expressed in IMAT of cows, steers, and bulls, respectively. In OMAT of cows, steers, and bulls, 33, 33, and 22 were confirmed to be differentially expressed, respectively. Tropomyosin (TPM) 1, TPM 2, and TPM3 were subjected to verification by quantitative PCR and western blot analysis in IMAT and OMAT of Hanwoo cows, steers, and bulls as key factors closely associated with muscle development. Both mRNA levels and protein levels of TPM1, TPM2, and TPM3 in IMAT were lower in bulls compared to in cows or steers suggesting that they were positively correlated with marbling score and quality grade. Our results may aid the regulation of marbling development and improvement of meat quality grades in beef cattle.

고선량율 원격강내조사의 코발트-60 이동선원에 의한 선량특성 (Dose Characteristics by the Co-60 Source Oscillations in High Dose Rate After Loading Irradiations)

  • 최태진;김옥배;노홍균
    • 한국의학물리학회지:의학물리
    • /
    • 제1권1호
    • /
    • pp.51-60
    • /
    • 1990
  • Dose distributions around Co- 60 moving source in high dose rate remote afterloading unit, Buchler 3K unit, were experimented with X-omat V films and calculations. In our experiments, film dosimetries have achieved to evaluated the axial dose distributions for source oscillations were 0, 3.5, 5.0 and 6.0 cm in periodically, In results, the dose distributions in axial of source movement showed apparently higher than in transverse direction caused by source locations, dwelling time and air gap in the applicator. In the calculations, the dose rate was derived by using the inverse square law, filteration corrections and Meisberger constant for scatter corrections as source movings. In our experiments and calculations, the average dose uncertainties were showed -2.1$\pm$1.9% in fixed sourdce, -2.9$\pm$1.8%, -7.4$\pm$6.1% and -6.7$\pm$4.6% at 3.5 cm, 5.0 cm and 6.0 cm source oscillations, but the calculations have showed very close to experimental dose rate within 4 cm distance from source.

  • PDF

구동 팬톰 시스템을 통한 내부 장기 움직임의 선량 평가

  • 김재균;김윤종;이동한;이동훈;김미숙;조철구;류성렬;양광모;유형준;지영훈
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2005년도 제30회 춘계학술대회
    • /
    • pp.64-67
    • /
    • 2005
  • 본 연구의 목적은 호흡 운동에 영향을 받는 내부 장기의 움직임을 정량적으로 분석하고, 그 결과를 토대로 움직이는 내부 장기의 선량 분포를 측정하고 평가하는 것이다. 그리고 이전에 보고된 논문에서 개발된 움직임 감소 장치의 사용 유무에 따른 내부 장기의 선량 분포 또한 분석하는 것이다. 이를 위하여 1차원적으로 움직이는 구동 팬톰 시스템을 개발하였고, 6MV X-ray에서 Kodak X-omat V 필름을 사용하여 움직이는 내부 장기의 선량분포를 실험적으로 측정하였다. 이 결과로부터 호흡 운동으로 인한 움직이는 내부 장기 및 종양에 조사되는 선량의 부정확도를 평가할 수 있었고, 움직임 감소 장치를 사용했을 때 선량의 부정확도가 감소함을 확인할 수 있었다.

  • PDF

Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • 홍동기;이우석;권경태;박광호;김정만
    • 대한방사선치료학회지
    • /
    • 제16권2호
    • /
    • pp.43-61
    • /
    • 2004
  • 목적 : 환자의 치료에 있어서 정확한 장비의 설치와 성능 평가는 치료의 질을 향상시키는데 중요한 요소라고 할 수 있으며 사용자가 장비의 특성과 사용 방법을 숙달하고 업무를 수행하는 것이 매우 중요하다고 생각한다. 그러므로 방사선 치료기를 설치하고 방사선 치료를 하기 전에 사용자가 직접 장비의 설치와 성능 평가에 참여하고 특성을 파악하여 이해하는 것이 필요하다. 본 연구에서는 CAP의 과정과 성능 평가결과를 소개하고자 한다. 대상 및 방법 : 선형가속기 21EX(varian, USA)를 대상으로 설치 시부터 성능 검사까지 전 과정을 평가하였고 성능평가는 크게 radiation survey, mechanical test, radiation isocenter test, beam performance, dosimetry, enhanced dynamic wedge로 구분하여 X-omat film(kodark), 선량 측정 장비(multidata, densitometer, electrometa)를 이용하여 실시하였다. 또한 선형가속기에 부착된 MLC(millenium, 120leaf)와 EPID(portal vision)의 성능 평가는 별도로 실시하였다. 결과 : Survey meter를 이용하여 측정한 leakage는 허용 범위 이하의 선량이 검출되었고 mechanical test에서 collimator, gantey, couch rotation은 1mm 이하였고 육안으로 평가한 angle은 digital이 ${\pm}1^{\circ}$이내에 mechanical은 ${\pm}5^{\circ}$이내였다. 또한 light field와 cross-hair의 직선성 검사도 1mm이내로 평가되었다. (A)symmetrical jaw field는 upper/lower 모두 ${\pm}0.5mm$이내였다. X-omat film을 이용한 radiation isocenter test는 1mm 이하였고 light field와 radiation field 의 일치성 검사는 ${\pm}1mm$ 이내였으며 선량 측정 장비를 이용하여 측정한 $\%DD$는 photon energy는 모두 ${\pm}1\%$ 이내로 electron energy는 $90\%,\;80\%,\;50\%,\;30\%$를 측정한 결과 허용 범위 내에서 평가되었다. photon 과 electron energy의 flateness는 각각 $2.3\%$(기준 $3\%$)이내, $3\%$(기준 $4.5\%$)이내이고 symmetry는 $0.45\%$(기준 $2\%$), $0.3\%$(기준 $2\%$)이내에서 평가 할 수 있었다. 그리고 dosimetry test는 sort term, MU setting, rep rate, dose rate accuracy를 photon과 electron energy 별로 MU와 gantry angle을 바꿔가면서 측정한 결과 허용범위 오차이내에 포함되는 것을 확인 할 수 있었다. EPID(portal vision)의 Exact-Arm의 기계적인 검사는 vertical, lateral, longitudinal은 허용범위 내에서 동작했으며 명암과 해상도 검사도 05.mm의 니크롬선이 선명하게 나타났으며 phantom의 음영도 뚜렷하게 나타났다. Multileaf collimator(MLC)검사는 leaf이 isocenter의 중심에 정확하게 배열되었으며 재현성 검사도 정상적으로 동작하였다. 결론 : Clinac 21EX 장치의 customer acceptance를 통해서 향후의 환자의 치료를 하는데 있어 장치의 안정성을 확인 할 수 있었으며 치료 전의 선형가속기와 주변장치의 특성을 파악 할 수 있어서 장비 사용에 있어서 어려움을 감소시킬 수 있으리라고 생각된다. 또한 사용자가 적극적으로 참여함으로써 앞으로 환자를 치료하는데 있어서도 많은 도움이 되리라 생각한다.

  • PDF

INDEPENDENT JAW를 이용한 인접한 HALF BEAM 조사야 경계에서 조작방법과 조작자에 따른 선량오차의 경향

  • 서정민;박용철;주상규
    • 대한방사선치료학회지
    • /
    • 제13권1호
    • /
    • pp.126-129
    • /
    • 2001
  • I. 목적 : Half beam을 이용하여 인접한 조사면 치료시, 경계부위에서 발생할 수 있는 Jaw Position에 의한 기하학적 오차는 정확한 선량전달에 문제를 일으킨다. 이에 본 저자는 QA용 필름을 이용하여 조사면 setting 방법과 조작자간의 오차를 분석하고 이를 최소화할 수 있는 방법을 찾고자 한다. II. 대상 및 방법 : 본 실험은 6MV선(CL2100C, Varian, USA)을 대상으로 하였으며, 폴리스틸렌팬톰($25{\times}25cm2$)을 SSD 100 cm으로 고정한 후, 측정용 필름(X-omat V2, Kodak, USA)을 5 cm 깊이에 위치 시켜 조사면의 중심에서 경계를 이루는 비대칭 조사면 ($0/7.5{\times}15,7.5/0{\times}15 cm$)을 쌍으로 조사하였다. 조사된 필름은 자동현상기를 이용하여 현상한 후 농도계(Densitometer, Multidata, USA)를 이용하여 중심축상에서의 농도분포를 측정하여 인접한 조사면에서의 오차를 분석하였다. 조작방법과 조작자간의 오차를 분석하기 위하여 5명의 방사선사를 대상으로 auto및 manual set-up을 실시하였고 각 방법의 평균 오차를 분석하기 위해 5회 반복하였다. III. 결과 : 필름 농도곡선을 이용하여 두 조사면이 만나는 경계에서의 오차를 분석한 결과, remote console set-up의 경우 주변 조사면에 비해 $-0.16{\pm}3.44\%$, pendant방식에서는 $+5.04{\pm}4.37\%$로 나타났고, 조작자간의 유의성이 관찰되었다. IV. 결론 : 비대칭 조사면을 이용한 근접 조사면의 치료시 pendant 방식보다 remote console 방식에서 오차가 적 게 나타나므로 Auto set-up 기능의 이용은 치료시에 조사면 경계에서의 선량 오차를 최소한으로 줄이는데 도움이 될 것으로 생각된다. 또한 manual 방식으로 set-up 시 오차의 편차가 크게 나타나므로 치료시에 세심한 주의가 필요할 것으로 사료된다.

  • PDF