• 제목/요약/키워드: OLTC transformer

검색결과 11건 처리시간 0.03초

OLTC를 고려한 고온 초전도 변압기의 설계 (Design of an HTS Transformer with OLTC)

  • 최지훈;이승욱;박명진;주형길;한진호;한송엽;최경달
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.67-71
    • /
    • 2007
  • HTS transformers which have been developed until now had only fundamental structures. Among the auxiliary functions of conventional transformers, voltage regulating is the most important one. For the voltage regulation, conventional transformers are equipped with on load tap changers (OLTCS). In this paper, we describe the possibility of the HTS transformer with OLTC. For the case study, we designed a single phase 33 MVA HTS transformer with OLTC. It is one of three individual HTS transformers which composes a 3 phase, 100 MVA transformer. It is expected to substitute for a 3 phase, 60 MVA conventional transformer in Korea. The parameters of an HTS transformer are varied due to the gap length between primary and secondary windings. The length was decided for the transformer to have the impedance of 12 %. Its size was limited to the one of the conventional transformer. The characteristics of the HTS transformer were analyzed in both case of having OLTC and not.

OLTC를 고려한 33 MVA 초전도 변압기 설계 (Design of a 33 MVA HTS Transformer with OLTC)

  • 최지훈;이승욱;박명진;김우석;최경달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.885-886
    • /
    • 2006
  • We have proposed a 100 MVA, 3 phases, 154 kV class HTS transformer which will substitute for 60 MVA conventional transformer. In this paper, we designed conceptually the structure of the superconducting windings of a single phase 33 MVA transformer. The power transformer of 154 kV class has a tertiary winding besides primary and secondary windings. So the HTS transformer should have the 3rd superconducting winding, it makes the cost of the HTS transformer high and the efficiency low. Further more we considered On Load Tap Changer (OLTC) in HTS power transformer. OLTC equipment is required for fitting to a power transformer by which the voltage ratio between the windings can be varied while the transformer is on load. We analyzed the electrical characteristics of the HTS transformer such as magnetic stress and AC loss.

  • PDF

자동 탭 절환 내장형 주상변압기 개발에 관한 연구 (Development Pole Transformer with Automatic Tap Changer)

  • 남궁원;이성우;장문종
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.108-113
    • /
    • 2013
  • Change of supply voltage, customer load, output of distributed generation, etc cause voltage change in distribution system. OLTC and SVR are usually used to supply normal voltage at customer. But usage of these devices is inefficient and uneconomical in certain circumstances. To solve this problem, new pole transformer which has automatic tap changer is developed. The transformer changes tap when voltage changes. And it has latch switch and reactor for supplying power without outage. To verify normal operation of tap changer, test is conducted. SVR and 50kVA load is used for test.

OLTC를 활용한 도시철도 최대전력 감축에 관한 연구 (The study on Reduction of Demand Power in Urban Railway using OLTC)

  • 김한수
    • 한국전자통신학회논문지
    • /
    • 제11권10호
    • /
    • pp.963-968
    • /
    • 2016
  • 논문에서는 도시철도의 변전소의 최대수요전력을 줄이기 위한 새로운 방법으로 OLTC(:On Load Tap Changer)를 갖는 변압기의 사용을 제안한다. 국내의 대부분의 도시철도는 전동차에 필요한 전력을 다이오드 방식으로 정류하며 DC 1500[V]로 공급한다. 변전소가 병렬로 연결되어 있기 때문에 수전전압이 상승하면 정류기 전압도 상승하게 되고 변전소의 최대전력도 증가하게 된다. 시뮬레이션 결과를 통해 본 논문에서 제안하는 방법이 최대수요전력의 증가를 상당히 제한할 수 있음을 보인다.

마이크로 프로세서를 이용한 탭 절환용 전압조절기의 연구개발 (Research and Development of AVR(Automatic Voltage Regulator) for OLTC(On Load Tap Changer) Using Microprocessor)

  • 김영남;민병권;윤재학;신현주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.710-713
    • /
    • 1992
  • An AVR for OLTC controls motor tap in transformer in order to supply constant power source. Recently for society which is higher informative and more automatic, in our research, the digital AVR for OLTC is developed that can perform more functions and higher functions ( mesurement, display, protection, control ) using microprocessor in a different control method than the conventional AVR. The experiment result is also present.

  • PDF

가스분석을 이용한 전력용 변압기 이상진단 연구 (A Study of the Preventive Diagnostic Algorithm of Gas Analysis in Oil for Power Transformer)

  • 최인혁;권동진;정길조;유연표;선종호;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1676-1678
    • /
    • 2001
  • In general, power demand is on an increasing trend as industries have made rapid strides. Power transformer is the most important equipment in substation for this reason. Transformer trobles go with blackout, expensive repair costs and huge economic losses. Therefore it is important to find the quick detection of incipient fault for the least losses. There have been gas, partial discharge, temperature, OLTC, fan and pump diagnosis for preventive techniques by present. Specially gas analysis has been adapted for a long time and proved as confident method. In this paper, we analysed the fault causes of used power transformer. The insulation faults was occupied 40% of inquired 152 faults from 1991 to 2000. This study presents the developed algorithm and expert system for finding abnormal status within transformer. We used the Element Expert tool developed Neuron DATA Inc.

  • PDF

Coordinated Voltage and Reactive Power Control Strategy with Distributed Generator for Improving the Operational Efficiency

  • Jeong, Ki-Seok;Lee, Hyun-Chul;Baek, Young-Sik;Park, Ji-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1261-1268
    • /
    • 2013
  • This study proposes a voltage and reactive coordinative control strategy with distributed generator (DG) in a distribution power system. The aim is to determine the optimum dispatch schedules for an on-load tap changer (OLTC), distributed generator settings and all shunt capacitor switching on the load and DG generation profile in a day. The proposed method minimizes the real power losses and improves the voltage profile using squared deviations of bus voltages. The results indicate that the proposed method reduces the real losses and voltage fluctuations and improve receiving power factor. This paper proposes coordinated voltage and reactive power control methods that adjust optimal control values of capacitor banks, OLTC, and the AVR of DGs by using a voltage sensitivity factor (VSF) and dynamic programming (DP) with branch-and-bound (B&B) method. To avoid the computational burden, we try to limit the possible states to 24 stages by using a flexible searching space at each stage. Finally, we will show the effectiveness of the proposed method by using operational cost of real power losses and voltage deviation factor as evaluation index for a whole day in a power system with distributed generators.

변압기 부분방전과 노이즈에 의한 초음파 신호 분석 (Analysis of the Ultrasonic Signals by the Partial Discharge and Noises from the Transformer)

  • 권동진;정길조;진상범;곽희로
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권8호
    • /
    • pp.354-360
    • /
    • 2002
  • The partial discharge detecting method using the ultrasonic technique has been investigated to monitor the insulation ageing of a transformer. However, the result of the studies on the ultrasonic technique for detecting of partial discharge in the operating transformer is not enough yet to utilize. This paper presents the analysis of the ultrasonic signals due to the partial discharge in a model transformer and the corona in air at a shielded high voltage room. In addition, the ultrasonic signals due to the vibration from the core, operation of the cooling pump, the fan and the OLTC at the 345㎸ power transformer, were analyzed and corona noise from overhead transmission line in 345㎸ substation were measured to remove the electrical and mechanical noises from the transformer. Furthermore, ultrasonic signal due to the partial discharge in the 154㎸ power transformer with in $C_2$$H_2$ gas warning condition was measured. The inside of the transformer was examined with care. which confirms the existence of the partial discharge source.

노이즈 제거 알고리즘을 적용한 변압기 초음파 상시 측정장치 개발 (Development of the On-line Ultrasonic Detecter for Transformer Applied Noise Rejection Algorithm)

  • 권동진;진상범;곽희로
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.80-91
    • /
    • 2002
  • 운전중인 변압기 내부의 부분방전에 의한 초음파 신호를 상시 감시하기 위한 초음파 상시 측정장치를 개발하였다. 초음파 상시 측정장치는 변압기 외부에서 발생하는 전기적 및 기계적인 노이즈를 제거하고 변압기 내부의 부분방전에 의한 초음파 신호만을 측정하기 위하여 50~300[KHz] 주파수 대역만 집중 측정하도록 협대역 필터를 설계하였으며, 초음파 센서는 60[dB] 증폭도의 프리앰프 내장형으로 개발하였다. 부분방전에 의한 초음파 신호와 특성이 유사한 부하시 탭 절환장치의 동작에 의한 초음파 신호를 제거하기 위하여, 초음파 신호의 지속시간으로 판별하는 초음파 신호판별 알고리즘을 개발하였다. 본 연구에서 개발한 초음파 상시 측정장치는 실험실의 모의 변압기와 현장에서 운전중인 변압기에서 부분방전에 의한 초음파 신호를 측정하여 신뢰성을 확인하였다.