• Title/Summary/Keyword: OLTC

Search Result 33, Processing Time 0.028 seconds

Design of an HTS Transformer with OLTC (OLTC를 고려한 고온 초전도 변압기의 설계)

  • Choi, J.H.;Lee, S.W.;Park, M.J.;Joo, H.G.;Han, J.H.;Hahn, S.Y.;Choi, K.D.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.67-71
    • /
    • 2007
  • HTS transformers which have been developed until now had only fundamental structures. Among the auxiliary functions of conventional transformers, voltage regulating is the most important one. For the voltage regulation, conventional transformers are equipped with on load tap changers (OLTCS). In this paper, we describe the possibility of the HTS transformer with OLTC. For the case study, we designed a single phase 33 MVA HTS transformer with OLTC. It is one of three individual HTS transformers which composes a 3 phase, 100 MVA transformer. It is expected to substitute for a 3 phase, 60 MVA conventional transformer in Korea. The parameters of an HTS transformer are varied due to the gap length between primary and secondary windings. The length was decided for the transformer to have the impedance of 12 %. Its size was limited to the one of the conventional transformer. The characteristics of the HTS transformer were analyzed in both case of having OLTC and not.

On-line coordination control of OLTC and Switched Shunt for enhancement of stability using local data in substation (변전소내 지역정보를 이용하여 안정도 향상을 위한 실시간 OLTC 및 커패시터 협조제어 알고리즘)

  • Kang, Sang-Gyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.7
    • /
    • pp.119-125
    • /
    • 2012
  • This paper suggest the on-line coordination control between on-load tap changers and Switched Shunts for ensuring the voltage stability using local data obtained from one substation. Inappropriate control of on-load tap changers that are able to maintain voltage profile might cause unintended result that is harmful to system stability, especially voltage stability. This paper utilizes Z-index that could inform the whole system condition from only one substation data. Simulation is performed using the HYPERSIM that is a digital simulator and matlab simulink to confirm the proposed algorithm.

The study on Reduction of Demand Power in Urban Railway using OLTC (OLTC를 활용한 도시철도 최대전력 감축에 관한 연구)

  • Kim, Han-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.10
    • /
    • pp.963-968
    • /
    • 2016
  • This paper proposes a new method reducing the maximum demand power of substations at urban railway by using transformer with OLTC(:On Load Tap Changer). Most of the domestic urban railway is rectified by a diode scheme, and supplies the electric vehicles in dc 1500[v]. Because the substations are connected in parallel, if an input voltage of a substation is increased, then the voltage of rectifiers is also increased, and which leads to an increase in the maximum demand of the substation. Simulation results show that increment of maximum demand power can significantly be limited using the method proposed in this paper.

Design of a 33 MVA HTS Transformer with OLTC (OLTC를 고려한 33 MVA 초전도 변압기 설계)

  • Choi, J.H.;Lee, S.W.;Park, M.J.;Kim, W.S.;Choi, K.D.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.885-886
    • /
    • 2006
  • We have proposed a 100 MVA, 3 phases, 154 kV class HTS transformer which will substitute for 60 MVA conventional transformer. In this paper, we designed conceptually the structure of the superconducting windings of a single phase 33 MVA transformer. The power transformer of 154 kV class has a tertiary winding besides primary and secondary windings. So the HTS transformer should have the 3rd superconducting winding, it makes the cost of the HTS transformer high and the efficiency low. Further more we considered On Load Tap Changer (OLTC) in HTS power transformer. OLTC equipment is required for fitting to a power transformer by which the voltage ratio between the windings can be varied while the transformer is on load. We analyzed the electrical characteristics of the HTS transformer such as magnetic stress and AC loss.

  • PDF

A study on voltage control system for 154kV substation (154kV 변전소 전압제어시스템에 대한 연구)

  • Jung, Kwang-Ho;Choi, Seung-Il;Song, Jae-Won;Kim, Jong-Woo;Yun, Byung-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.121-123
    • /
    • 2007
  • 본 논문에서는 Shunt capacitor와 OLTC가 함께 설치된 154kV 변전소에서 송출전압을 고려한 두 기기의 협조제어 시스템에 대해 연구하고자 한다. Shunt Capacitor는 전압제어뿐 아니라 외란이 발생할 경우 안정도 제어에 매우 유용한 중요 기기이다. 그러나 비상시 안정도 제어에 참여하기 위해서는 평상운전 시 적정한 운전여유를 확보하고 있어야 한다. 또한 Shunt capacitor와 OLTC의 특성과 상호작용을 고찰하여 Shunt Capacitor의 무효전력 보상 여유를 유지하고 전압의 변동을 방지하면 OLTC의 탭동작을 최소화하여 고장의 요소를 방지하는 협조제어를 제안한다.

  • PDF

Research and Development of AVR(Automatic Voltage Regulator) for OLTC(On Load Tap Changer) Using Microprocessor (마이크로 프로세서를 이용한 탭 절환용 전압조절기의 연구개발)

  • Kim, Y.N.;Min, B.G.;Yun, J.H.;Shin, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.710-713
    • /
    • 1992
  • An AVR for OLTC controls motor tap in transformer in order to supply constant power source. Recently for society which is higher informative and more automatic, in our research, the digital AVR for OLTC is developed that can perform more functions and higher functions ( mesurement, display, protection, control ) using microprocessor in a different control method than the conventional AVR. The experiment result is also present.

  • PDF

EMTP Simulation for the Dynamic Analysis of a STATCOM-Shunts-OLTC Coordination in Substation (변전소 조상 설비간의 협조 제어를 위한 EMTP 과도해석모형 개발)

  • Jeong, Ki-Seok;Baek, Young-Sik;Park, Ji-Ho;Chang, Byung-Hoon;Lee, Hyun-Chul;Lee, Geun-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.237_238
    • /
    • 2009
  • This paper proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC. Voltage/Reactive power control has various difficult aspects to control because of analysis and system dynamics error. This coordinative control method suggests practical algorithm regarding system voltage and reactive power status which is easy to implement in substation basis. In normal status, STATCOM-Shunts-OLTC are in operation. The proposed algorithm is tested and verified in EMTP/RV. And this is expected to be applied to control multiple reactive power devices combined with SCADA/EMS system.

  • PDF

Coordinated Voltage and Reactive Power Control Strategy with Distributed Generator for Improving the Operational Efficiency

  • Jeong, Ki-Seok;Lee, Hyun-Chul;Baek, Young-Sik;Park, Ji-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1261-1268
    • /
    • 2013
  • This study proposes a voltage and reactive coordinative control strategy with distributed generator (DG) in a distribution power system. The aim is to determine the optimum dispatch schedules for an on-load tap changer (OLTC), distributed generator settings and all shunt capacitor switching on the load and DG generation profile in a day. The proposed method minimizes the real power losses and improves the voltage profile using squared deviations of bus voltages. The results indicate that the proposed method reduces the real losses and voltage fluctuations and improve receiving power factor. This paper proposes coordinated voltage and reactive power control methods that adjust optimal control values of capacitor banks, OLTC, and the AVR of DGs by using a voltage sensitivity factor (VSF) and dynamic programming (DP) with branch-and-bound (B&B) method. To avoid the computational burden, we try to limit the possible states to 24 stages by using a flexible searching space at each stage. Finally, we will show the effectiveness of the proposed method by using operational cost of real power losses and voltage deviation factor as evaluation index for a whole day in a power system with distributed generators.

THE DIAGNOSTIC EFFECT OF THE SIMULTANEOUS MULTIFILM INDIVIDUALIZED LATERAL TOMOGRAPHY IN THE DIAGNOSIS OF THE TEMPOROMANDIBULAR DISORDERS (악관절장애진단에 있어서 동시다층개별화측방단층촬영의 진단효과)

  • Lee Woo-Shik;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.235-248
    • /
    • 1991
  • This study was designed to evaluate the diagnostic effect of the simulatneous multifilm individualized lateral tomography in the diagnosis of the temporomandibular disorders. The subjects consisted of 29 patients with symptoms of the temporomandibular disorders. The panoramic view, oblique lateral transcranial radiograph (OLTC) (Hirozontal angulation 0°, Vertical angulation 29°), submentovertex view, and simultaneous multifilm individualized lateral tomographs (SMFI) in centric occlusion (2.5㎜ thickness difference, 5 layers) were taken for the patients. This study compared the findings from each radiographs in the determining of mandibular condylar position with dual linear measurement of the subjective closest posterior and subjective closest anterior interarticular space and in the determining of bony changes on the studied 30 temporomandibular joints (TMJ) with symptoms of the temporomandibular disorders. The results were as follows: 1. The distribution of condylar position of OLTC and 5 layers of SMFI depended on the radiographs (p<0.05). The condylar position and the distribution of condylar position of OLTC were more similar to lateral sections of the SMFI than mesial sections, and in the distribution of the condylar position of SMFI, the more lateral sections of SMFI, the more concentric 2. positions. There were 10 cases in which all layers showed the same condylar position as that of OLTC. There were 3 cases in which no layers showed the same condylar position as that of OLTC. 3. In the SMFI of 30 Temporomandibular joints studied, there is 13 cases in which all five layers represented the same condylar position in the same TMJ and 11 cases in which 4 layers represented the same condylar position in the same TMJ and 6 cases in which 3 layers represented the same condylar position in the same TMJ. So at least 3 layers of SMFI represented same condylar position in the same TMJ. 4. The bony changes were not detected in conventional radiographs on the temporomandibular joint and the bony changes were not detected in simultaneous multifilm individualized lateral tomographs. The bony changes were detected in conventional radiographs on the temporomandibular joint and the bony changes were detected in simultaneous multifilm individualized lateral tomographs. SMFI provided a meams for a three dimensional visualization of the shape, the position and the extent of bony changes of TMJ.

  • PDF

A Study on Local Coordinative Reactive Power Control between STATCOM and Other Reactive Power Controllers for Voltage Stability Improvement at Substation (변전소 전압안정화를 위한 STATCOM과 기존 조상 설비간의 지역 무효전력 협조제어에 관한 연구)

  • Jeong, Ki-Seok;Chang, Byun-Hoon;Lee, Hyun-Chul;Lee, Geun-Joon;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.525-530
    • /
    • 2010
  • Installation of FACTS(Flexible AC Transmission System) device can maximize utilization of existing power facilities and reliability of power system. STATCOM has excellent characteristics in operating cost, maintaining facilities, loss and so on. However, STATCOM has a disadvantage of facility cost over capacity. So it is effective to coordinate STATCOM and existing external bank(capacitor and reactor) and OLTC(On Load Tap Changer). This paper mainly proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC for voltage stability improvement. The proposed coordinative control method is developed for the STATCOM of Mi-gum substation and the simulation results of EMTP/RV model show the effectiveness of the proposed method.