• 제목/요약/키워드: Nutrient Removal Treatment

검색결과 209건 처리시간 0.021초

Denaturing Gradient Gel Electrophoresis Analysis of Bacterial Populations in 5-Stage Biological Nutrient Removal Process with Step Feed System for Wastewater Treatment

  • Lee, Soo-Youn;Kim, Hyeon-Guk;Park, Jong-Bok;Park, Yong-Keun
    • Journal of Microbiology
    • /
    • 제42권1호
    • /
    • pp.1-8
    • /
    • 2004
  • Changes in the bacterial populations of a 5-stage biological nutrient removal (BNR) process, with a step feed system for wastewater treatment, were monitored by denaturing gradient gel electrophoresis (DGGE) of PCR-amplified 16S ribosomal DNA fragments. DGGE analysis indicated seasonal community changes were observed, however, community profiles of the total bacteria of each reactor showed only minor differences in the samples obtained from the same season. The number of major bands was higher in the summer samples, and decreased during the winter period, indicating that the microbial community structure became simpler at low temperatures. Since the nitrogen and phosphate removal efficiencies were highly maintained throughout the winter operation period, the bacteria which still remaining in the winter sample can be considered important, playing a key role in the present 5-stage BNR sludge. The prominent DGGE bands were excised, and sequenced to gain insight into the identities of the predominant bacterial populations present, and most were found to not be closely related to previously characterized bacteria. These data suggest the importance of culture-independent methods for the quality control of wastewater treatment.

Parametric study of brewery wastewater effluent treatment using Chlorella vulgaris microalgae

  • Choi, Hee-Jeong
    • Environmental Engineering Research
    • /
    • 제21권4호
    • /
    • pp.401-408
    • /
    • 2016
  • The aim of this study was to evaluate the biomass and lipid production of Chlorella vulgaris and its nutrient removal capability for treatment of brewery wastewater effluent. The results indicate that the maximum biochemical oxygen demand (BOD) (91.43%) and chemical oxygen demand (COD) (83.11%) were removed by C. vulgaris with aeration in the absence of light. A maximum of 0.917 g/L of dry biomass was obtained with aeration in the dark conditions, which also demonstrated the highest amount of unsaturated fatty acids at 83.22%. However, the removal of total nitrogen (TN) and total phosphorus (TP) with these aeration and light conditions was 9.7% and 11.86% greater than that of other conditions. The removal of BOD and COD and the production of biomass and lipids with aeration in the dark and the TN and TP removal with aeration and light were more effective than other conditions in the brewery wastewater effluent in the presence of C. vulgaris.

습지의 수환경과 영양물질에 미치는 침수식물의 영향 (Effects of Submerged Plants on Water Environment and Nutrient Reduction in a Wetland)

  • 이용민;이석모;성기준
    • 한국물환경학회지
    • /
    • 제26권1호
    • /
    • pp.19-27
    • /
    • 2010
  • Submerged plants whose most of vegetative mass are below the water surface can have great effects on wetland biogeochemistry and water purification through their photosynthesis and nutrient uptake processes. In this study, change of dissolved oxygen concentration and pH as well as nutrient removal capacity of the submerged plant dominant wetland were investigated using wetland mesocosm experiments. Obvious periodic DO and pH fluctuation was observed due to photosynthetic activities of the submerged plants. It implies that the submerged plants can provide periodic or sequential changes of oxic and anoxic conditions that affect nitrification and denitrification processes and contribute permanent nitrogen removal in the wetland system. The pH changes in the wetland mesocosm suggested that submerged plant could also play an important role as a temporary $CO_2$ storage. Higher nutrient removal efficiency was observed in the submerged plant dominant wetland mesocosm. The removal efficiencies under experimental conditions were 38.89, 84.70, 91.21, 70.76, 75.30% of TN, DIN, $NH_4-N$, TP, $PO_4-P$ in the wetland mesocosm, while those were 26.11, 57.34, 63.87, 28.19, 55.15% in the control treatment, respectively.

하수처리장의 고도처리 upgrading 설계와 공정 최적화를 위한 다변량 통계분석 (Design of a Wastewater Treatment Plant Upgrading to Advanced Nutrient Removal Treatment Using Modeling Methodology and Multivariate Statistical Analysis for Process Optimization)

  • 김민정;김민한;김용수;유창규
    • Korean Chemical Engineering Research
    • /
    • 제48권5호
    • /
    • pp.589-597
    • /
    • 2010
  • 하수처리 시스템에서의 생물학적 영양염류 기준이 강화됨에 따라, 표준활성슬러지공법으로 운전 중인 하수처리장의 고도처리 공법으로의 개보수 필요성이 증가하고 있다. 그러나 실제 하수처리 시스템에서의 다양한 유입조건 및 운전조건의 복잡한 반응 구성으로 인해 실험을 통하여 개보수된 고도처리공법의 최적조건을 찾는 것은 쉽지 않은 일이며, 이는 많은 시간과 비용을 소모하여 비효율적이다. 따라서 본 연구에서는 활성슬러지공정모델(ASMs)을 기반으로 한 하수처리장의 모델링 및 시뮬레이션 기법을 통하여 하수처리장의 고도처리공법으로의 upgrading 설계를 수행하며, 이를 통계적이며 체계적으로 접근하기 위해 반응표면분석법(Response surface method)을 통한 고도처리공법의 설계 최적화를 수행하였다. 또한 실규모 하수처리장에서의 운전 최적화를 위해서는 하수처리의 동력학적 매개변수에 대한 정확한 분석이 수행되어야 한다. 본 연구에서는 다변량 통계분석 기법인 부분최소승자법(PLS)을 통하여 하수처리 시스템의 동력학적 매개변수 간의 상관관계를 파악하며, 고도처리공법 하수처리장의 운전 결과에 가장 큰 영향을 미치는 매개변수를 도출하였다. 본 연구를 통해 하수처리장의 고도처리공법 upgrading 설계 및 운전 최적화를 위한 방법론을 제시하였으며, 이를 통하여 설계시간 및 경비 절감 등 고도처리공법으로의 고효율적인 개보수가 가능할 것으로 예상된다.

Scenedesmus sp.를 이용한 하수의 영양물질 제거에 관한 연구 (A Study on the Nutrient Removal of Wastewater Using Scenedemus sp.)

  • 이희자
    • 한국환경과학회지
    • /
    • 제8권4호
    • /
    • pp.443-449
    • /
    • 1999
  • This paper describe the working of algal culture system under batch and continuous feeding effluents in biological treatment process. The main objective of this study was the determination of fundamental opeating parameters such as dilution rates, light intensity, biomass concentration, nutrients contents, which engender an effective nutrient and organic waste removal process. The results of this research indicate that the algae system will remove effectively nutrient and organic waste. In batch cultures, 91.8% dissolved orthophosphate and 83.3% ammonia nitrogen were removed from the sewage in ten days. In continuous flow systems, a detention time of 2.5 days was found adequate to remove 91% T-P, 87% T-N and 95% $NH_3-N$. At 22-28$^{\circ}C$, 60 rpm, with an intensity of 3500 Lux, the specific growth rate, k was 0.59/day in batch experiments. The optimal growth temperature and nutrients rate (N/P) were respectively $25^{\circ}C$ and 3~5. With an abundant supply of untrients, it was possible to sustain substantial population densities in the temperature range of 22~28$^{\circ}C$.

  • PDF

수정 DNR 공정을 이용한 하수처리 (Sewage Treatment Using a Modified DNR Process)

  • 최진택;남세용
    • 한국환경보건학회지
    • /
    • 제34권6호
    • /
    • pp.446-451
    • /
    • 2008
  • In this study, the removal characteristics of organic components and nutrients of sewage taken from the Suwon area were investigated in a lab-scale modified DNR (Daewoo Nutrient Removal) process. The modified DNR process consisted of a sludge denitrification tank, an anaerobic tank, an anoxic tank, an aerobic tank, a secondary anoxic tank and a secondary aerobic tank. The proposed process with the average C/N ratio of 3.5 was performed for the sewage treatment. The results were compared with other existing DNR processes. The organic fractions in sewage were analyzed by measuring the oxygen uptake rate. The resulting removal efficiencies of SS, BOD, COD, TN and TP were 93.1%, 95.5%, 86.1%, 67.8% and 80.6%, respectively.

개인하수처리시설 처리수의 수질 개선을 위한 응집보조제로서의 천연제올라이트 적용에 관한 연구 (A Study on the Application of Natural Zeolite as Coagulant Aid for Effluent Quality Improvement in Private Sewage Treatment Facility)

  • 최정수;주현종
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.121-128
    • /
    • 2012
  • The purpose of this study is to solve the problem of nutrient removal due to rapid hydraulic retention time (HRT) variation in small size private sewage treatment facility and to have better effluent quality by using natural zeolite as a coagulant aid. The experiments were conducted by applying different conditions of HRT, coagulant, and zeolite dosages. As an experimental result, $TBOD_{5}$, TSS, and TP removal efficiencies were 64.9%, 94.5%, and 98.8% at co-injection with zeolite. Overall removal efficiencies of $TBOD_{5}$, TSS, and TP have improved 15.7, 28.7, 6.1%, respectively. This result shows that zeolite addition could improve flocculation, increase setting velocity, and thus have better treatment. Therefore the use of zeolite as a coagulant aid can be useful in small size private sewage treatment facility, where especially extra nutrient removal is required to meet the legal standard for discharge.

A Study on Inactivation of Pathogenic Bacteria for Nutrient Solution Recycling Using Advanced Oxidation Processes

  • Jang, Gwan-Soon;Nam, Yi
    • 한국토양비료학회지
    • /
    • 제50권5호
    • /
    • pp.489-496
    • /
    • 2017
  • This study was conducted to test the applicability of hydroxy radical reactor system, which applied advanced oxidation processes, to sterilize pathogenic bacteria for nutrient solution recycling in closed hydroponics. Removal efficiency was tested on 25 L of nutrient solution maxed with 10 mL culture solution of bacteria, E. coli, and R. solanacearum in a pilot tank. The testing conditions included various levels of hydroxy radicals resulting from air flow rates of 40, 80, and $120L\;min^{-1}$, and 12 hours processing time. The removal of bacteria, E. coli, and R. solanacearum by hydroxy radical in nutrient solution was significantly increased with an increase in the flow rate of the air from $40L\;min^{-1}$ to $120L\;min^{-1}$. The optimum removal efficiency was achieved at an air flow rate of $120L\;min^{-1}$ for 2 hours treatment. There were no significant differences in removal efficiency among bacteria, E. coli, and R. solanacearum for tested level and time of hydroxy radical. These results verified the efficiency of hydroxy radical in removing the pathogenic bacteria and the applicability of hydroxy radical reactor system in the field.

BNR에 의한 하수의 고도처리에 미치는 NH3 스트리핑 전처리의 영향 (Effect of Pre-NH3 Stripping on the Advanced Sewerage Treatment by BNR)

  • 서정범;안광호
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.846-850
    • /
    • 2006
  • The biological nutrient removal from domestic wastewater with low C/N ratio is difficult. Therefore, this study was performed to increase influent C/N ratio by ammonia stripping without required carbon source and for improving treatment efficiencies of sewerage by the combination process of ammonia stripping and BNR (StripBNR). The results of this study were summarized as follows. BOD removal efficiencies of BNR and StripBNR were 95.3% and 93.2%, respectively. T-N and T-P removal efficiencies of BNR were 53.3% and 40.8%, respectively. T-N and T-P removal efficiencies of StripBNR were 72.8% and 62.9%, respectively. Concentrations of $NH_3-N$, $NO_2-N$ and $NO_3-N$ at BNR effluent were 0.03 mg/L, 0.08 mg/L and 9.12 mg/L, respectively. On the other hands, concentrations of $NH_3-N$, $NO_2-N$ and $NO_3-N$ at StripBNR effluent were 5.79 mg/L, 0.01 mg/L and 0.14 mg/L, respectively. Consequently, influent C/N ratio of BNR process was increased by ammonia stripping. Removal efficiency of T-N and T-P was improved about 20% by the process of StripBNR.

하수종말처리장 방류수와 비점오염원 처리를 위한 주암호 인공습지 2년 운영 사례 (Case Study: Operation of the Juam Constructed Wetland for Effluent from a Sewage Treatment Plant and Diffuse Pollution for Two Years)

  • 정용준
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.1031-1037
    • /
    • 2006
  • In order to improve water quality of the Juam Lake, a constructed wetland was implemented and operated for 2 years with the effluent of sewage treatment plant and diffuse pollutant discharged from agricultural area. During the summer season, average removal efficiencies for BOD and SS were 15.8% and 39.4%, respectively. Due to the mixed effect of vegetation, soil microbes and sediments, the higher nutrient removal efficiencies were obtained: average T-N and T-P removal efficiencies were 64.2% and 71.7%, respectively. The concentration of sediment was increased initially, and maintained constant throughout monitoring period. The highest nitrogen and phosphorus uptake were observed in Phragmites japonica. The nitrogen uptake was estimated as 0.235 DW mg/g while phosphorus uptake was estimated as 2.059 DW mg/g.