DOI QR코드

DOI QR Code

A Study on Inactivation of Pathogenic Bacteria for Nutrient Solution Recycling Using Advanced Oxidation Processes

  • Jang, Gwan-Soon (Department of Environmental Health, Daejeon Health Institute of Technology) ;
  • Nam, Yi (National Agricultural Cooperative Federation)
  • Received : 2017.09.25
  • Accepted : 2017.11.06
  • Published : 2017.10.31

Abstract

This study was conducted to test the applicability of hydroxy radical reactor system, which applied advanced oxidation processes, to sterilize pathogenic bacteria for nutrient solution recycling in closed hydroponics. Removal efficiency was tested on 25 L of nutrient solution maxed with 10 mL culture solution of bacteria, E. coli, and R. solanacearum in a pilot tank. The testing conditions included various levels of hydroxy radicals resulting from air flow rates of 40, 80, and $120L\;min^{-1}$, and 12 hours processing time. The removal of bacteria, E. coli, and R. solanacearum by hydroxy radical in nutrient solution was significantly increased with an increase in the flow rate of the air from $40L\;min^{-1}$ to $120L\;min^{-1}$. The optimum removal efficiency was achieved at an air flow rate of $120L\;min^{-1}$ for 2 hours treatment. There were no significant differences in removal efficiency among bacteria, E. coli, and R. solanacearum for tested level and time of hydroxy radical. These results verified the efficiency of hydroxy radical in removing the pathogenic bacteria and the applicability of hydroxy radical reactor system in the field.

Keywords

References

  1. Acher, A., B. Heuer, E. Rubinskaya, and E.E. Fischer. 1997. Use of ultraviolet-disinfected nutrient solutions in green-houses. J. Hortic. Sci. 72:117-123. https://doi.org/10.1080/14620316.1997.11515498
  2. Back, S.E., D.S. Kim, and Y.S. Park. 2012. Inactivation of Ralstonia solanacearum using aquatic plasma process. J. Environ. Sci. Int. 21(7):797-804. https://doi.org/10.5322/JES.2012.21.7.797
  3. Cho, J.Y., S.B. Seok, and C.S. Ju. 2000. Present status and prospect of sterilization of nutrient solution for recycled hydroponics. Korean J. Hortic. Sci. Technol. 18(6):890-899.
  4. Do, J.S., H.J. Chung, and W.S. Bang. 2015. Bacterial effects of pathogenic bacteria on acid treatment combined with red, green, and blue LED light at a low temperature environment. J. Korean Soc. Food Sci. Nutr. 44(11):1725-1732. https://doi.org/10.3746/jkfn.2015.44.11.1725
  5. Guzzella, L., D. Feretti, and S. Monarca. 2002. Advanced oxidation and adsorption technologies for organic micropollutant removal from lake water used as drinking water supply. Water Res. 36(17):4307-4318. https://doi.org/10.1016/S0043-1354(02)00145-8
  6. Kim, D.S. and Y.S. Park. 2011. Optimization of air-plasma and oxygen-plasma process for water treatment using central composite design and reponses surface methodology. J. Environ. Sci. Int. 20(7):907-917. https://doi.org/10.5322/JES.2011.20.7.907
  7. Kim, D.S and Y.S. Park. 2014. A study on the Ralstonia solanacearum inactivation using improved plasma process. J. Environ. Sci. Int. 23(3):369-378. https://doi.org/10.5322/JESI.2014.23.3.369
  8. Kim, H.J., Y.H. Woo, W.S. Kim, and Y.I. Nam. 2000. Problem and optimum control of nutrient solution management in closed hydroponics. Korean J. Hortic. Sci. Technol. 18(6):884-889.
  9. Kim, S.A., S.Y. Ahn, W. Oh, and H.K. Yun. 2012. in vitro test of mycelial growth inhibition of 5 fungi pathogenic to strawberries by ultraviolet-C (UV-C) irradiation. J. Korean Soc. Food Sci. Nutr. 44(3):634-637
  10. Lee, H.C. 2014. Necessity and challenge project of closed-system in the hydroponics. Korean J. Hortic. Sci. Technol. 32:31-32.
  11. Lee, H.J., E.J. Jo, N.H. Kim, Y. Chae, and S.W. Lee. 2011. Disease responses of tomato pure lines against Ralstonia solanacearum strains from Korea and susceptibility at hight temperature. Res. Plant Dis. 17(3):326-333. https://doi.org/10.5423/RPD.2011.17.3.326
  12. Lee. J.S., J.H. Choi, S.T. Seo, K.S. Han, J.H. Park, H.I. Jang. 2005. Control of tomato wilt disease by amending pH of nutrient solution in hydroponic system. Res. Plant Dis. 11(2):193-197. https://doi.org/10.5423/RPD.2005.11.2.193
  13. Lee, M.H., S.E. Kim, S.D. Lee, J.E. Lee, H.S. Kim, S.K. Cho, S.Y. Sim, and Y.S. Kim. 2016. Development of drainage water disinfection system by electric shock in recirculation soilless culture. Protected Horticulture and Plant Factory 25(1):49-56. https://doi.org/10.12791/KSBEC.2016.25.1.49
  14. Mamesh, T., T.O. Kwon, J.C. Jun, S. Balaji, M. Mathrswaran, and I.S. Moon, 2006. Application of several advanced oxidation process for the destruction of terephthalic acid (TPA). J. Hazard Mater 142(1-2):308-314. https://doi.org/10.1016/j.jhazmat.2006.08.023
  15. Ministry of Environment. 2007. Official testing method with respect to water pollution process.
  16. Nam, Y.I. 2004. Present status and further prospects for development of closed hydroponic in Korea. Korea Res. Soc. Protected Hortic. 17(1):1-7.
  17. No, Y.M. 2003. Nutrient solution recycling in closed hydroponics. Kor. Res. Soc. Protected Hort. 16(2):35-42.
  18. Runia, W.T. 1994. Elimination of root-infecting pathogens in recirculation water from closed cultivation with ozone. Act Hortic. 361:388-396
  19. Vogelpohl, A and S.M. Kim. 2004. Advanced oxidation processes (AOPs) in wastewater treatment. J. Indus. Eng. Chem. 10(1):33-40. https://doi.org/10.1021/ie50097a017
  20. Yun, G.G., S.Y. Park, H.J. Kang, K.Y. Lee, and J.S. Cha. 2004. Contamination level of Ralstonia solanacearum in soil of greenhouses cultivating tomato plants in Chungbuk province and characteristics of the isolates. Res. Plant Dis. 10(1):58-62. https://doi.org/10.5423/RPD.2004.10.1.058
  21. Zhang P., F. Liang, G. Yu, G. Chen, and W. Zhu 2003. A comparative study on decomposition of gaseous toluene by $O_3/UV$ and $O_3/TiO_2/UV$. J. Photochem. Photobio. A: Chemistry, 156, pp 189-194. https://doi.org/10.1016/S1010-6030(02)00432-X