• Title/Summary/Keyword: Number of rows

Search Result 241, Processing Time 0.025 seconds

New records of two soil and one marine ciliate species (Ciliophora: Intramacronucleata) from Korea

  • Park, Mi-Hyun;Min, Gi-Sik
    • Journal of Species Research
    • /
    • v.6 no.spc
    • /
    • pp.67-70
    • /
    • 2017
  • Three ciliate species, Australocirrus australis (Foissner, 1995) Kumar and Foissner, 2015, Rimaleptus longitrichus ($Vd^{\prime}a{\check{c}}n{\acute{y}}$ and Foissner, 2008) $Vd^{\prime}a{\check{c}}n{\acute{y}}$ and Foissner, 2012, and Frontonia subtropica Pan et al., 2013, that were previously unreported in Korea were collected from terrestrial and marine habitats in Korea. Using live observation and protargol impregnation, the three species were identified using a combination of the following characteristics: Australocirrus australis, the distance between the anterior pretransverse cirrus and the anteriormost transverse cirrus (0.6-2.1% of body length) and the arrangement of the transverse cirri (oblique row); Rimaleptus longitrichus, the arrange of contractile vacuoles and longitudinal ciliary rows anteriorly spaced; Frontonia subtropica, number of somatic kineties (approximately 115 rows) and vestibular kineties (5 rows).

Heat Transfer Coefficients of Individual Rows for Fin-and-Tube Heat Exchangers (휜-관 열교환기의 열별 열전달 계수 측정)

  • Shin, T.R.;Lee, E.R.;Kim, N.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1034-1039
    • /
    • 2004
  • The row-by-row heat transfer characteristics of fin-and-tube heat exchangers having wavy fins were experimentally investigated. Three samples having different rows (one, two and three) were tested. Results show that the heat transfer coefficient is strongly dependent on the tube row. The heat transfer coefficient of the first row is larger than those of second or third rows. However, the difference decreases as the Reynolds number increases. The heat transfer coefficients of the second and the third row are approximately the same, probably due to increased mixing of bulk flow by wavy channels. Although samples have different tube row, the heat transfer coefficients of same row are approximately the same.

  • PDF

Reconfiguration method for array structures using spare element lines (여분소자 라인을 이용한 배열구조의 재구성 방법)

  • 김형석;최상방
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.2
    • /
    • pp.50-60
    • /
    • 1997
  • Reconfiguration of a memory array using spare rows and columns has been known to be a useful technique to improve the yield. When the numbers of spare rows and scolumns are limited, respectively, the repair problem is known to be NP-complete. In this paper, we propose the reconfiguration algorithm for an array of memory cells using faulty cel clustering, which removes rows and columns algrithm is the simplest reconfiguration method with the time complexity of $O(n^2)$, where n is the number of faulty cells, however the repair rate is very low. Whereas the exhaustive search algorithm has a high repair rate, but the time complexity is $O(2^n)$. The proposed algorithm provides the same repair rate as the exhaustive search algorithm for almost all cases and runs as fast as the greedy method. It has the time complexity of $O(n^3)$ in the worst case. We show that the propsed algorithm provides more efficient solutions than other algorithms using simulations.

  • PDF

EVALUATION OF PEDESTRIAN SIGNAL TIMING AT SIGNALIZED INTERSECTION (신호횡단보도 보행등 녹색신호시간에 관한 연구)

  • 장덕명;박종주
    • Journal of Korean Society of Transportation
    • /
    • v.12 no.1
    • /
    • pp.55-73
    • /
    • 1994
  • The objective of this research is to evaluate the pedestrian signal time involving green and flashing green times. The minimum pedestrian green indication should give time for pedestrian to start crossing safely, and the flashing green indication should give time to complete the crossing. An average pedestrian crossing speed of 1.1(m/s) was estimated by analyzing the field data which was slower than the 1.2(m/s) currently used. Furthermore, the study proposed that design speed for the flashing green time should be slow speed for considerations pedestrian safety, not the average speed. The 0.78-1.01(m/s) of pedestrian speed was estimated at the elementary school areas that indicated 0.2(m/s) slower than the other areas. The pedestrian starting time (perception/reaction time) and time headway from front to back of herd was estimated to determine minimum pedestrian green time. the pedestrian starting time was estimated to determine minimum pedestrian green time. The pedestrian starting time was ranged 2.52-4.29 seconds. The time interval between the pedestrian rows was found to be 1.25-1.86 seconds, which declines as the pedestrian rows increases, The equation to calculate the pedestrian signal, which declines as the pedestrian rows increases. The equation to calculate the pedestrian signal time is proposed using the pedestrian starting time, the time interval between the pedestrian rows, and pedestrian crossing speed given area types (commercial, business, mixed, and elementary school areas), number of both-directional pedestrians for a cycle, crosswalk length and width.

  • PDF

First Record of Two Urostyloid Ciliates (Spirotrichea: Urostylida: Urostyloidea) from Brackish Water in Korea

  • Choi, Jung-Min;Kim, Ji-Hye;Shin, Mann-Kyoon
    • Animal Systematics, Evolution and Diversity
    • /
    • v.27 no.3
    • /
    • pp.228-238
    • /
    • 2011
  • Two urostyloid ciliates, collected from brackish water in Korea, were identified as Diaxonella pseudorubra pseudorubra (Kaltenbach, 1960) Berger, 2006 and Pseudokeronopsis flava (Cohn, 1866) Wirnsberger, Larsen and Uhlig, 1987. The description was based on living, protargol impregnated specimens. These species are described as follows: Diaxonella pseudorubra pseudorubra: body size in vivo $145-230{\times}40-60\;{\mu}m$, elongated ellipsoidal in shape. Cytoplasm reddish and flexible. Adoral zone of membranelles occupied 30-40% of the body; composed of 33-44 membranelles; 1-3 frontoterminal cirri, 1-4 frontal row cirri, 4-6 buccal cirri, 6-10 transverse cirri. Midventral rows composed of 14-24 cirri, four left marginal rows, one right marginal row. Two kinds of cortical granules; the larger one is yellowish and the smaller one is reddish. Pseudokeronopsis flava: body size in vivo $150-210{\times}30-45\;{\mu}m$, elongated ellipsoidal shape. Cytoplasm yellowish and flexible. Adoral zone of membranelles occupied 25-30% of body; composed of 44-58 membranelles in number. Frontal cirri forming bicorona composed of 5-7 cirral pairs, 2-3 frontoterminal cirri, one buccal cirrus, and 2-3 transverse cirri. Midventral rows composed of 18-33 cirri, 34-53 left marginal cirri, and 40-58 right marginal cirri. Two kinds of cortical granules; the larger one is colorless and "blood-cell-shaped," and the smaller one is yellowish. Diaxonella pseudorubra pseudorubra is different from the most similar subspecies, D. pseudorubra pulchra, in cytoplasmic color and number of midventral cirri. Pseudokeronopsis flava is different from its most similar congeners in pigment granular color, number of bicorona, number of midventral cirri, and position of the contractile vacuole.

A Study on the Buckling Characteristics of Spacer Grids in Pressurized Water Reactor Fuel Assembly (경수로용 핵연료집합체 지지격자의 좌굴특성에 관한 연구)

  • Jeon Sang-Youn;Lee Young-Shin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.4 s.70
    • /
    • pp.405-416
    • /
    • 2005
  • This study contains the static buckling tests and static buckling analyses for small size grids and full size grids. The buckling tests and finite element analyses were performed to evaluate the buckling characteristics of the spacer grids in a pressurized water reactor fuel assembly and to evaluate the possibility of the prediction lot the buckling strength of spacer grids. The buckling tests were performed for small size grids and full size grids, and the correlations between buckling strength and the number of straps and the correlations between buckling strength and the number of rows are derived based on the test results. The static buckling analyses were performed to identify the effect of the number of rows and the number of columns on the buckling strength of spacer grid by a finite element method using ANSYS program and the results were compared with the buckling test results.

Morphology and Reproduction of Some Species of Ceramium (Rhodophyta) in Culture (홍조 비단풀속 식물의 실내부양에 따른 형태변화와 생식에 관하여)

  • Suh, Youngbae
    • Journal of Plant Biology
    • /
    • v.27 no.3
    • /
    • pp.163-171
    • /
    • 1984
  • Ceramium kindoi Yendo demonstrates a Polysiphonia type of life history without diviation in unialgal culture. However, cultures of C. paniculatum Okamura and C. aduncum Nakamura from Kangneung shows considerable phenotypic variations in laboratory. In C. paniculatum, the subulate spines disappear, the transverse cell-rows of corticating bands decrease in number, and the growing direction of corticating cells is changed during the culture. In C. aduncum, a species new to Korea, frond apices become slightly incurved in contrast to strongly rolled ones in the field, and the rows of corticating cells decrease in number and height during the culture. These results suggest that some significant taxonomic characters currently used for identification of Ceramium species are reconsidered.

  • PDF

Characteristics of Auditory Stereocilia in the Apical Turn of the Echolocating Bats by Scanning Electron Microscopy

  • Kim, Jinyong;Jung, Yongwook
    • Applied Microscopy
    • /
    • v.44 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • The auditory system of the Korean greater horseshoe bat (Rhinolophus ferrumequinum korai, RFK) is adapted to its own echolocation signal, which consist of constant frequency (CF) element and frequency modulated (FM) element. In contrast, the Japanese long-fingered bat (Miniopterus schreibersii fuliginosus, MSF) emits FM signals. In the present study, the characteristics of stereocilia in RFK (a CF/FM bat) and MSF (a FM bat) were studied in the apical turn of the cochlea where the lower frequencies are transduced. Stereocilia lengths and numbers were quantitatively measured in RFK by scanning electron microscopy and compared with those of MSF. Each inner hair cells (IHCs) of RFK possessed three rows of stereocilia, whereas MSF possessed five rows of stereocilia. Gradients in stereocilia lengths and numbers of stereocilia of the IHCs of RFK were found to be less pronounced and fewer, respectively, than those of MSF. Each outer hair cells (OHCs) possessed three rows of stereocilia in both species. OHCs stereocilia in RFK that distinguished it from MSF were a shorter length and a greater number of stereocilia. These features suggest that the apical cochleas of RFK are adapted for the processing of higher frequency echolocation calls rather than that of MSF.

Soybean Growth and Yield as Affected by Spacing of Drainage Furrows in Paddy Field

  • Cho, Jin-Woong;Lee, Jung-June;Oh, Young-Jin;So, Jung-D.;Won, Jun-Yeon;Kim, Chang-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.1
    • /
    • pp.26-31
    • /
    • 2006
  • This study was conducted to determine the optimum number of inter-rows according to distance of drainage furrow (DF) for running-off excessive-water stress (EWS) in paddy field. The most soil water potential was shown in high ridge (distance of DF by 70 cm) cultivation and the soil water potential showed increasing tendency in over four inter-rows cultivation by DF. The growth of soybean reduced by extended inter-row and its reducing level was high, especially, over four inter-rows (DF distance by 2.8 m) because of EWS. The photosynthetic rate decreased in the more extensive field by distance of DF at V5 and R2 stages, especially, in over four interrows cultivation. Also, root activity decreased at wider DF. The yield was reduced with wider distance of DF more extensively, the highest yield of 270 g per $m^2$ at the every row, but yield showed decreasing tendency at over the $4^{th}$ row (2.8 m) cultivation. Soybean cultivation in paddy field could be founded with DF of every other or $4^{th}$ row.

Bulk Flow Pulsations and Film Cooling from Two Rows of Staggered Holes : Effect of Blowing Ratios (주유동의 맥동과 엇갈린 2열 분사홀로부터의 막냉각 : 분사비의 영향)

  • Sohn, Dong Kee;Lee, Joon Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.9
    • /
    • pp.1195-1207
    • /
    • 1998
  • Periodic pulsations in the static pressure near turbine surfaces as blade rows move relative to each other is one of the important sources of turbine unsteadiness. The present experiment aims to investigate the effect of the static pressure pulsations on the interaction of film coolant flows from two rows of staggered holes with mainstream and its effect on film cooling heat transfer. Potential flow pulsations are generated by the rotating shutter mechanism installed downstream of the test section, The free-stream Strouhal number based on the boundary layer thickness is in the range of 0.033 - 0.33, and the amplitude of about 10-20%. Measured are time-averaged and phase-averaged velocity variations, pressure variations and temperature distributions of the flow field. Experimental conditions are identified by boundary layer measurements. Injectant behavior is characterized by the measurements of unsteady pressure in the plenum chamber and free-stream static pressure. The film cooling effectiveness is evaluated from the insulated wall temperature measurement. It has been found that bulk flow pulsation provides very large diffusion of the injectants and the effectiveness is significantly reduced by the flow pulsations.