Transactions of the Korean Society of Mechanical Engineers B (대한기계학회논문집B)
- Volume 22 Issue 9
- /
- Pages.1195-1207
- /
- 1998
- /
- 1226-4881(pISSN)
- /
- 2288-5324(eISSN)
DOI QR Code
Bulk Flow Pulsations and Film Cooling from Two Rows of Staggered Holes : Effect of Blowing Ratios
주유동의 맥동과 엇갈린 2열 분사홀로부터의 막냉각 : 분사비의 영향
- Received : 1997.03.26
- Published : 1998.09.01
Abstract
Periodic pulsations in the static pressure near turbine surfaces as blade rows move relative to each other is one of the important sources of turbine unsteadiness. The present experiment aims to investigate the effect of the static pressure pulsations on the interaction of film coolant flows from two rows of staggered holes with mainstream and its effect on film cooling heat transfer. Potential flow pulsations are generated by the rotating shutter mechanism installed downstream of the test section, The free-stream Strouhal number based on the boundary layer thickness is in the range of 0.033 - 0.33, and the amplitude of about 10-20%. Measured are time-averaged and phase-averaged velocity variations, pressure variations and temperature distributions of the flow field. Experimental conditions are identified by boundary layer measurements. Injectant behavior is characterized by the measurements of unsteady pressure in the plenum chamber and free-stream static pressure. The film cooling effectiveness is evaluated from the insulated wall temperature measurement. It has been found that bulk flow pulsation provides very large diffusion of the injectants and the effectiveness is significantly reduced by the flow pulsations.