• 제목/요약/키워드: Number of rows

검색결과 241건 처리시간 0.021초

2열 핀-관 열 교환기의 열별 전열성능 측정 (Heat Transfer Performance of Individual Rows in Fin-Tube Heat Exchangers)

  • 권영철;정지환;장근선;홍기수;진심원
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.280-286
    • /
    • 2004
  • An experimental study is peformed to examine the heat transfer performance of individual rows of fin-tube heat exchangers. The heat transfer performance is measured using an air-enthalpy type calorimeter. The examined heat exchangers consist of 7mm tube and fin patterns of them are slit and louver types. Equivalent fin spacings are 18 fins per inch(fpi) for all samples, and the number of tube rows are two. In order to confirm that thermal boundary condition on fins of each row are the same, physically separated between two rows as well as connected heat exchangers are used. The frontal air velocity is varied from 0.7 to 2.5㎧. Heat transfer performance for each row is measured. It is observed that the heat transfer coefficient of the second row is smaller than that of the first row at low Reynolds number while larger at high Reynolds number.

핀-관 열교환기에서 개별 열의 열전달 효과 (Heat Transfer Performance of Individual Rows in Fin-Tube Heat Exchangers)

  • 정지환;장근선;이현우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.238-244
    • /
    • 2003
  • An experimental study was performed to examine the heat transfer performance of individual rows of fin-tube heat exchangers. The heat transfer performance was measured using air-enthalpy type calorimeter. The examined heat exchangers consists of $7{\Phi}$ tube and fin patterns of them are slit and louver types. Equivalent fin spacing are 18 FPI for all samples, and the number of tube rows were 2. In order to confirm that thermal boundary condition on fins of each row are the same, physically separated between two rows as well as connected heat exchangers were used. The frontal air velocity varied from 0.7 to 2.5 m/s. Heat transfer performance for each row are measured. It was observed that the heat transfer coefficient of the 2nd row were smaller than that of the 1st row at low Reynolds number while larger at high Reynolds number.

  • PDF

벼 주연효과의 품종간 차이와 그 생장해석 (Varietal Difference and Growth Analysis of Border Effect in Rice Plant)

  • 김광호;양충환
    • 한국작물학회지
    • /
    • 제29권4호
    • /
    • pp.321-327
    • /
    • 1984
  • 벼 재배시에 나타나는 주연효과의 품종간 차이와 생장해석을 통한 주연효과의 원인을 알고져 3품종을 공시하여 시험한 결과를 요약하면 다음과 같다. 1. 논의 외연 1∼2 열에 심겨진 벼의 수량은 내부열에 비하여 평균 30% 정도 많았는데 주연효과는 품종에 따라서 최대 35%, 최소 21%이었다. 2. 주연효과에 의한 수량증가는 논의 외부 1∼2열에서만 나타났으나 한강찰벼는 외연으로부터 4열까지도 주연효과가 나타났다. 30 주연효과는 주당수수와 수당입수에서 현저하게 나타났다. 4. 수건물중과 엽면적은 이앙후 30∼60일경부터 외열과 내열간에 차이가 나타났는데 조생종은 중만생종보다 주연효과에 의한 건물중과 엽면적의 차이가 빨리 나타났다. 5. 개체군생장속도, 상대생장율, 순동화율 및 엽면적비 등에 있어서도 주연효과를 나타내는 시기가 많았다.

  • PDF

핀-관 열교환기의 열별 열전달 특성 (Heat Transfer Characteristics of Individual Rows for Fin-and-Tube Heat Exchangers)

  • 김내현;신태룡;한성필
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.149-155
    • /
    • 2007
  • The row-by-row heat transfer characteristics of fin-and-tube heat exchangers were experimentally investigated. Three wavy fin samples having different rows (one, two and three) and one plain fin sample (three row) were tested for $600{\leq}Re_{D}{\leq}4,000$. The heat transfer data were obtained for individual rows, and the corresponding heat transfer coefficients were reduced from the data. Results showed that the heat transfer coefficients were strongly dependent on the tube row. The heat transfer coefficient decreased as the tube row increased. However, the row effect was different depending on the fin shape. For the wavy fin, the row effect significantly decreased as the Reynolds number increased, yielding approximately the same heat transfer coefficients at $Re_{D}{\approx}2,500$. For the plain fin, however, the row effect lasted for the whole Reynolds number range. The increased mixing of bulk flow by wavy channels appears to induce high heat transfer coefficient (accordingly diminishing row effect) at downstream rows. The heat transfer coefficients of individual rows were higher for heat exchangers having larger tube rows.

Description of Two Oxytrichid Ciliates (Ciliophora: Sporadotrichida: Oxytrichidae) Newly Reported from Korea

  • Kwon, Choon-Bong;Shin, Mann-Kyoon
    • Animal Systematics, Evolution and Diversity
    • /
    • 제26권3호
    • /
    • pp.307-316
    • /
    • 2010
  • To investigate the Korean ciliate fauna, two oxytrichid ciliates, Laurentiella strenua (Dingfelder, 1962) and Notohymena australis (Foissner and O'Donoghue, 1990) were collected from the Taehwa River in Ulsan, South Korea. These two ciliates are reported for the first time in Korea. Descriptions were based on the observation of live and silver stained specimens. Diagnoses of these species are as follows: Laurentiella strenua: body is approximately $320{\times}170\;{\mu}m$ in size, an inverted triangular shape. Cytoplasmic globules are present in both anterior and posterior margins, transparent and sized $10-15\;{\mu}m$ in live specimens. Adoral zone of membranelles is covering about 50% of body length. Frontoventral-transverse cirri are arranged diagonally into 5 rows. Transverse cirri are arranged almost longitudinally and varied 4-6 in number. Dorsal kineties are 11 rows with multiple fragmentations. Macronuclei are 4-5 in number. Notohymena australis: body is approximately $170{\times}50\;{\mu}m$ in live specimens, slender and long ellipsoidal shape. Yellowish green cortical granules are present as pairs or rows which composed of 3-6 granules. Adoral zone of membranelles is covering about 36% of the body length, composed of 39-50 adoral membranelles. Dorsal kineties is 6 rows. Macronuclei are 2 in number.

태양전지 모듈 구조와 바이패싱 동작 포인트의 관계 분석 (The study on the relationship between structure of PV module and bypassing point)

  • 지양근;공지현;강기환;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.70-70
    • /
    • 2010
  • Until recently. the study about bypass diode has been limited to theoretical study. but, in this paper, We study on the relationship between structure of PV module and Bypassing point by simulation software(Pspice). We expected the design on the PV module has an effect on bypassing point. So, we designated the two kind of experiment with PV modules. One of the experiment is on the relationship between the number of rows and Bypassing point on the PV modules, the other experiment is on the relationship between the number of groups(two columns) on the PV modules.(around 50Wp, 100Wp, 150Wp, 200WP) As the result, the more increase the number of rows, bypassing point is faster. And the more increase the number of groups in more than 3 groups, bypassing point is faster more than case of increasing the rows.

  • PDF

Morphological redescriptions of three Cyrtohymena ciliates (Ciliophora: Sporadotrichida: Oxytrichidae) new to Korea

  • Kim, Yeon Uk;Lee, Jung Mi;Kwon, Choon Bong;Shin, Mann Kyoon
    • Journal of Species Research
    • /
    • 제1권1호
    • /
    • pp.78-86
    • /
    • 2012
  • Three ciliate species of genus Cyrtohymena, C. australis Foissner, 1995, C. citrina (Berger & Foissner, 1987) and C. muscorum (Kahl, 1932) new to Korea, were collected from semi-terrestrial habitats. The description was based on the observation of live and silver stained specimens. Diagnostic characteristics of these species are as follows. C. autralis: size about $275{\times}100{\mu}m$ in live specimens. Cortical granules yellowish. 18-31 right and 31-40 left marginal cirri in number. Dorsal kineties eight rows. C. citrina: size about $180{\times}50{\mu}m$ in live specimens. Cortical granules yellowish. 26-32 right and 23-27 left marginal cirri in number. Dorsal kineties five to six rows. C. muscorum: size about $180{\times}60{\mu}m$ in live specimens. Cortical granules reddish. 31-34 right and 33-36 left marginal cirri in number. Dorsal kineties six rows. Three species of Cyrtohymena have been added to Korean ciliate fauna from this study. Including previous one species of C. quadrinucleata, four species of this genus in total have been recorded so far in this country.

히이트 파이프용 열교환기의 에너지 회수효과 해석 해법 (An Analytical Method on the Effective Energy Recovery for Heat Exchanger with Heat Pipes)

  • 장영석;서해성;이영수;전철호
    • 태양에너지
    • /
    • 제9권2호
    • /
    • pp.31-41
    • /
    • 1989
  • The purpose of this research is to study the utility of prediction program like a F.E.M. analysis for energy recovery of heat exchanger with heat pipe which uses arbitrary groove wick. The program is based on the utility by the experimental and applytical method of the single heat pipe. It is also expanded and applied in the prediction program of the heat exchanger. The results are as follows; 1) The effective thermal conductivity of the groove wick with arbitrary shape is counted by the thermal resistance change. 2) The more the number of rows, the more the effect energy recovery changing by the number of rows, the bigger the free velocity, the smaller the effect of energy recovery. 3) The effect of energy recovery increases according to the value of the rate of mass flow (Me/Mc) and also number of rows. 4) The comparison between calculated and data shows good agreement within 2.5% error, therefore the F.E.M. analysis of the study is useful to predict the performance of heat pipe-heat exchanger.

  • PDF

웨이브 및 웨이브-슬릿 열전달촉진 휜-관 열교환기의 공기측 압력강하 및 열전달 특성에 관한 실험 (Experimental study of air side pressure drop and heat transfer characteristics of wave and wave-slit fin-tube heat exchangers)

  • 윤백;길용현;박현연;유국철;김영생
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.589-599
    • /
    • 1998
  • Air side heat transfer and pressure drop for fin-tube heat exchanger with wave and wave-slit fins were measured for various fin spacings and number of tube rows. Outer diameter of the tube including fin collar is 10.07mm, and experiments were done with dry surface condition. Longitudinal and transverse tube spacings of the heat exchangers are 21.65mm and 25mm respectively, and wave depth of the wave fin is 2mm. Experiments were conducted for 1, 2 and 3 rows and 3 different fin spacings, 1.3, 1.5 and 1.7mm. An attempt was made to demonstrate advantage of the enhanced fins over the plane fin by introducing the concept of fan power, Effect of the number of tube rows on heat transfer was discussed in connection with general mechanisms of heat transfer enhancement for fin-tube heat exchanger. Also the effect of hydrophilic coating was investigated. Lastly, correlations for Colburn j-factor and friction factor were developed.

  • PDF

열전달 촉진 핀-관 열교환기의 공기측 압력강화 및 열전달 특성에 관한 실험 (Experimental Study of Air Side Pressure Drop and Heat Transfer Characteristics of Enhanced Fin-Tube Heat Exchangers)

  • 윤백;길용현;박현연;김영생
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1555-1563
    • /
    • 1998
  • Heat transfer and pressure drop for ${\phi}10.07$ dry surface fin-tube heat exchanger with wave and wave-slit fins were measured for different fin spacings and number of tube rows. Longitudinal and transverse tube spacings of the heat exchangers are 21.65mm and 25mm respectively, and wave depth of wave fin is 1.5mm. The experiments were performed for 4 different fin spacings, 1.3, 1.5, 1.7 and 2.0mm, and the number of tube rows were 1,2 and 3 rows. The present results were compared with the previous results for the wave depth of 2mm. Also hydrophilic coated and bare fins were tested. Correlations for Colburn j-factor and friction factor were developed.