• 제목/요약/키워드: Number concentration

검색결과 4,000건 처리시간 0.031초

도계처리 단계별 도체와 처리수의 세균오염 및 염소처리 효과 (Efficacy of Chlorine for Reducing Bacterial Populations and Bacteriological Contamination on Carcass and Treatment Water at Different Stage of Poultry Processing)

  • 이철현;변유성;황보원;조광제;강호조
    • 한국동물위생학회지
    • /
    • 제20권2호
    • /
    • pp.169-175
    • /
    • 1997
  • This study was carried out to assess the effect of the chlorine treatment into water for processing chicken products in each stage of slaughtering, with a special viewpoint related with reducing the viable number of microorganisms by which the water and the chicken body were contaminated. The mean bacterial number on chicken samples after picking process was log5.37$\pm$0.20~5.84$\pm$0.160CFU/$\textrm{cm}^2$. When assessed by standard plate count method, it was the higher one than any other processing stage in which eviscerating, pinning, packaging, and chilling was followed in order of the mean bacterial number. The coliform bacterial numbers on carcasses after sampling from different processing stages were log2.11$\pm$0.63~2.88$\pm$0.25MPN/$\textrm{cm}^2, which show almost similar numbers in each processing stage. But, after chilling process the number was decreased slightly. The bacterial counts in the water for scalding and chilling showed log3.43 $\pm$ 0.59~5.06$\pm$0.21 and log4.30$\pm$0.21~6.62$\pm$0.33CFU/$m\ell$, respectively. In the coliform counts for the water taken out from the 2nd chilling tank, the number was log1.97$\pm$0.35~2.91$\pm$0.22MPN/$m\ell$ which showed higher than those of the 1st and the 3rd chilling tank water. The effect of chlorination in reducing the bacterial numbers was accepted at the residual chlorine concentration of 1$m\ell$/$\ell$by showing the reduction from $10^8$ to $10^4$CFU level and the numbers were decreased less than 10CFU at the concentration of 5mg/$\ell$, when assessed by viable cell counts. In conclusion, these results suggested that chlorination In chilling water with final concentration of 5mg/$\ell$was strongly recommended to reduce the bacterial numbers on final chicken products.

  • PDF

대나무류 3종 소다-안트라퀴논 펄프 내 존재하는 hexeneuronic acid가 카파 값에 미치는 영향 (Impact of hexeneuronic acid on kappa number determination in 3 different bamboo soda-anthraquinone(AQ) pulps)

  • 송우용;이규성;이숙경;신수정
    • 펄프종이기술
    • /
    • 제48권3호
    • /
    • pp.73-79
    • /
    • 2016
  • Hexeneuronic acid in soda-anthraquinone(AQ) pulps from Moso bamboo(Phyllostachys pubescebs), Timber bamboo(Phyllostachys bambusoides) and Henon bamboo(Phyllostachys nigra var. henonis) was investigated with mercuric chloride hydrolysis and UV spectroscopic quantification. Concentration of hexeneuronic acid in bamboo pulps was $36.6-45.4{\mu}mol/g$, which contributed to 3.1-3.9 value increase of kappa number. Lower concentration of 4-O-methylglucuronic acid in bamboo xylan contributed to lower hexeneruonic acid content in bamboo pulps than those of hardwood(yellow poplar or eucalyptus) but higher than softwood(red pine).

태양열 집광 흡수기내의 종횡비가 공간내의 열전달에 미치는 영향 (Study on the Heat Transfer into by Space by the Aspect Ratio of Solar Concentration Absorber.)

  • 이용훈;이중섭;배강열;정효민;정한식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.199-204
    • /
    • 2001
  • This paper showed the study on the heat transfer into space by the aspect ratio of solar concentration absorber, and the purpose of this study is to obtain the optimum aspect ratio and tilt angle. The boundary conditions of a numerical model were assumed as follows : (1) The heat source is located at the center of absorber. (2) The bottom was is opened and adiabatic. (3) The top, right and left walls are cooled wall. The parameters for the study are the tilt angles and the aspect ratio. The velocity vectors and isotherms were dense at wall side and the heat source. The mean Nusselt number had a maximum value at Ar=1:1 and $\theta=0^{\circ}$ and showed a low value as the tilt angles were increased.

  • PDF

DC 코로나 방전이 적용된 에틸렌 정상 확산 화염의 Soot 배출 저감 (Reduction of Soot Emitted from a $C_2$$H_4$ Normal Diffusion Flame with Application of DC Corona Discharge)

  • 이재복;황정호
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.496-506
    • /
    • 2001
  • The effect of corona discharge on soot emission was experimentally investigated. Size and number concentrations of soot aggregates were measured and compared for various voltages. Regardless of the polarity of the applied voltage, the flame length decreased and the tip of flame spreaded with increasing voltage. For the experimental conditions selected, the flame was blown off toward the ground electrode by corona ionic wind. When the negative applied voltage was greater than 3kV(for electrode spacing = 3.5cm), soot particles in inception or growth region were affected by the corona discharge, resulting in the reduction of number concentration. The results show that the ionic wind favored soot oxidation and increased flame temperature. Number concentration and primary particle size greatly increased, when the corona electrodes were located the region of soot nucleation or growth(close to burner mouth).

Effects of ring number and baffled-ring distances on ultrafiltration in the tubular membrane inserted concentrically with a ring rod

  • Yeh, Ho-Ming;Ho, Chii-Dong;Li, Cha-Hsin
    • Membrane and Water Treatment
    • /
    • 제3권1호
    • /
    • pp.51-62
    • /
    • 2012
  • The permeate flux declination along an ultrafilter membrane is due mainly to the concentration-polarization resistance increment and the decline in transmembrane pressure. It was found in previous works that the concentration polarization resistance could be reduced in a ring-rod tubular membrane ultrafilter using the turbulent behavior. In the present study, the performance was further improved by properly and gradually decreasing the baffled-ring distance along the cross-flow channel coupled with properly adjusting the number of baffled rings. This theoretical analysis is based on the mass and momentum balances as well as the application of the resistance-in-series model. The correlation predictions are confirmed with the experimental results for dextran T500 aqueous solution ultrafiltration.

종횡비에 따른 태양열 집광흡수기의 열전달특성 (Heat Transfer Charaeteristic of Solar Concentration Absorber by the Aspect Ratio)

  • 이용훈;이중섭;배강열;정효민;정한식
    • 동력기계공학회지
    • /
    • 제6권1호
    • /
    • pp.43-49
    • /
    • 2002
  • This paper showed the study on the heat transfer into space by the aspect ratio of solar concentration absorber, and the purpose of this study was to obtain the optimum aspect ratio and tilt angle. The boundary conditions of a numerical model are assumed as follows : (1) The heat source is located at the center of absorber. (2) The bottom wall is opened and adiabatic. (3) The top, right and left walls are cooled wall. The parameters for the study are the tilt angles and the aspect ratio. The velocity vectors and isotherms were dense at wall side and the heat source. The mean Nusselt number had a maximum value at Ar=1:1 and ${\theta}=0^{\circ}$ and showed a low value as the tilt angles were increased.

  • PDF

서울시 지역별 $SO_2$ 오염도 분석에 관한 연구 (A Study on the Analysis of $SO_2$ Concentration in the Metro Seoul)

  • 송동웅;김원만
    • 한국대기환경학회지
    • /
    • 제7권1호
    • /
    • pp.23-30
    • /
    • 1991
  • The major purpose of this study is to delineate and assess the regional $SO_2$ levels in Seoul. This study is based on 1988 year-round data from 20 air quality continuous monitoring stations in Seoul. Statistical analyses were attempted, statistical parameters such as average concentration, standard deviation, maximum concentration, minimum concentration and monthly highest concentration were included in the analyses. In addition, Larsen's averaging time analysis was evaluated in terms of 24-hr concentration. The $SO_2$ levels in 1988 were that most stations except Daechidong, Sinlimdong, Jamsil 2, Bangidong violate the long-term standard (annual average 0.05 ppm) and the percentage of number of days within a year in which the 24-hr average concentration observed exceeds short-term standard (0.15 ppm) are; 37% at Deungchondong, 30% at Sinseoldong, mor than 20% at Ssangmundong, Myunmogdong and Oryudong.

  • PDF

High Time-resolution Characterization of PM2.5 Sulfate Measured in a Japanese Urban Site

  • Ma, Chang-Jin;Kang, Gong-Unn;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • 제9권4호
    • /
    • pp.280-287
    • /
    • 2015
  • The high time-resolution monitoring data are essential to estimate rapid changes in chemical compositions, concentrations, formation mechanisms, and likely sources of atmospheric particulate matter (PM). In this study, $PM_{2.5}$ sulfate, $PM_{2.5}$, $PM_{10}$, and the number concentration of size-resolved PMs were monitored in Fukuoka, Japan by good time-resolved methods during the springtime. The highest monthly average $PM_{2.5}$ sulfate was found in May ($8.85{\mu}g\;m^{-3}$), followed by April ($8.36{\mu}g\;m^{-3}$), March ($8.13{\mu}g\;m^{-3}$), and June ($7.22{\mu}g\;m^{-3}$). The cases exceed the Japanese central government's safety standard for $PM_{2.5}$ ($35{\mu}g\;m^{-3}$) reached 10.11% during four months campaign. The fraction of $PM_{2.5}$ sulfate to $PM_{2.5}$ varied from 12.05% to 68.11% with average value of 35.49% throughout the entire period of monitoring. This high proportion of sulfate in $PM_{2.5}$ is an obvious characteristic of the ambient $PM_{2.5}$ in Fukuoka during the springtime. However, the average fraction of $PM_{2.5}$ sulfate to $PM_{2.5}$ in three rain events occurred during our intensive campaign fell right down to 15.53%. Unusually high $PM_{2.5}$ sulfate (> $30{\mu}g\;m^{-3}$) marked on three days were probably affected by the air parcels coming from the Chinese continent, the natural sulfur in the remote marine atmosphere, and a large number of ships sailing on the nearby sea. The theoretical number concentration of $(NH_4)_2SO_4$ in $PM_{0.5-0.3}$ was originally calculated and then compared to $PM_{2.5}$ sulfate. A close resemblance between the diurnal variations of the theoretically calculated number concentration of $(NH_4)_2SO_4$ in $PM_{0.5-0.3}$ and $PM_{2.5}$ sulfate concentration indicates that the secondary formed $(NH_4)_2SO_4$ was the primary form of sulfate in $PM_{2.5}$ during our monitoring period.

Ultrafine Particle Events in the Ambient Atmosphere in Korea

  • Maskey, Shila;Kim, Jae-Seok;Cho, Hee-Joo;Park, Kihong
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권4호
    • /
    • pp.288-303
    • /
    • 2012
  • In this study, real time measurements of particle number size distribution in urban Gwangju, coastal Taean, and industrial Yeosu in Korea were conducted in 2008 to understand the occurrence of ultrafine particle (UFP) (<100 nm) events, the variation of its concentration among different sampling sites, and UFP formation pathways. Also, to investigate seasonal and long-term variation of the UFP number concentration, data were collected for the period of 5 years (2007, 2008, 2010, 2011, and 2012) in urban Gwangju. Photochemical and combustion events were found to be responsible for the formation of UFP in the urban Gwangju site, whereas only photochemical event led to the formation of UFP in the coastal Taean site. The highest UFP concentration was found in industrial Yeosu (the average UFP number fractions were 79, 59 and 58% in Yeosu, Gwangju, and Taean, respectively), suggesting that high amount of gas pollutants (e.g., $NO_2$, $SO_2$, and volatile organic carbon (VOC)) emitted from industries and their photochemical reaction contributed for the elevated UFP concentration in the industrial Yeosu site. The UFP fraction also showed a seasonal variation with the peak value in spring (61.5, 54.5, 50.5, and 40.7% in spring, fall, summer, and winter, respectively) at urban Gwangju. Annual average UFP number concentrations in urban Gwangju were $5.53{\times}10^3\;cm^{-3}$, $4.68{\times}10^3\;cm^{-3}$, $5.32{\times}10^3\;cm^{-3}$, $3.99{\times}10^3\;cm^{-3}$, and $2.16{\times}10^3\;cm^{-3}$ in the year 2007, 2008, 2010, 2011, and 2012, respectively. Comparison of the annual average UFP number concentration with urban sites in other countries showed that the UFP concentrations of the Korean sites were lower than those in other urban cities, probably due to lower source strength in the current site. TEM/EDS analysis for the size-selected UFPs showed that the UFPs were classified into various types having different chemical species. Carbonaceous particles were observed in both combustion (soot and organics) and photochemical events (sulfate and organics). In the photochemical event, an internal mixture of organic species and ammonium sulfate/bisulfate was identified. Also, internal mixtures of aged Na-rich and organic species, aged Ca-rich particles, and doughnut shaped K-containing particles with elemental composition of a strong C with minor O, S, and K-likely to be originated from biomass burning nearby agricultural area, were observed. In addition, fly ash particles were also observed in the combustion event, not in the photochemical event.

타코나이트 광산 공정에서의 실시간 질량측정기기와 실시간 수농도의 환산에 의한 질량농도와의 연관성 (Relationships between a Calculated Mass Concentration and a Measured Concentration of PM2.5 and Respirable Particle Matter Sampling Direct-Reading Instruments in Taconite Mines)

  • 정은교;장재길;송세욱;김정호
    • 한국산업보건학회지
    • /
    • 제24권1호
    • /
    • pp.65-73
    • /
    • 2014
  • Objectives: The purposes of this study are to investigate workers' exposures to respirable particles generated in taconite mines and to compare two metric methods for mass concentrations using direct-reading instruments. Methods: Air monitorings were conducted at six mines where subjects have been exposed primarily to particulate matters in crushing, concentrating, and pelletizing processes. Air samples were collected during 4 hours of the entire work shift for similarly exposure groups(SEGs) of nine jobs(N=37). Following instruments were employed to evaluate the workplace: a nanoparticle aerosol monitor(particle size range; 10-1000 nm, unit: ${\mu}m^2/cc$, Model 9000, TSI Inc.); DustTrak air monitors($PM_{10}$, $PM_{2.5}$, unit: $mg/m^3$, Model 8520, TSI Inc.); a condensation particle counter(size range; 20-1000 nm, unit: #/cc, P-Trak 8525, TSI Inc.); and an optical particle counter(particle number by size range $0.3-25{\mu}m$, unit: #/cc, Aerotrak 9306, TSI Inc.). Results: The highest airborne concentration among SEGs was for furnace operator followed by pelletizing maintenance workers in number of particle and surface area, but not in mass concentrations. The geometric means of $PM_{2.5}$ by the DustTrak and the Ptrak/Aerotrak were $0.04{\mu}m$(GSD 2.52) and $0.07{\mu}m$(GSD 2.60), respectively. Also, the geometric means of RPM by the DustTrak and the Ptrak/Aerotrak were $0.16{\mu}m$(GSD 2.24) and $0.32{\mu}m$(GSD 3.24), respectively. The Pearson correlation coefficient for DustTrak $PM_{2.5}$ and Ptrak/Aerotrak $PM_{2.5}$ was 0.56, and that of DustTrak RPM and Ptrak/Aerotrak RPM was 0.65, indicating a moderate positive association between the two sampling methods. Surface area and number concentration were highly correlated($R^2$ = 0.80), while $PM_{2.5}$ and RPM were also statistically correlated each other($R^2$ = 0.79). Conclusions: The results suggest that it is possible to measure airborne particulates by mass concentrations or particle number concentrations using real-time instruments instead of using the DustTrak Aerosol monitor that monitor mass concentrations only.