• 제목/요약/키워드: Number concentration

검색결과 3,994건 처리시간 0.03초

Flow of casson nanofluid along permeable exponentially stretching cylinder: Variation of mass concentration profile

  • Iqbal, Waheed;Jalil, Mudassar;Khadimallah, Mohamed A.;Hussain, Muzamal;Naeem, Muhammad N.;Naim, Abdullah F. Al;Mahmoud, S.R.;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • 제38권1호
    • /
    • pp.33-45
    • /
    • 2021
  • The Runge-Kutta method of 6th-order has been employed in this paper to analyze the flow of Casson nanofluid along permeable exponentially stretching cylinder. The modeled PDEs are changed into nonlinear ODEs through appropriate nonlinear transformations. The aim of the paper is to investigate the effects of different parameters such as Casson fluid parameter, slip parameter, suction parameter, Prandtl number, Lewis number, Brownian motion parameter, and thermophoresis parameter, with the variation of mass concentration profile. Numerical results are attained using a renowned numerical scheme shooting technique and for the authenticity of present methodlogy, the results are verified with earlier open text.

연직풍에 따른 해양성 에어러솔 수 농도 변동에 관한 연구 (The Fluctuation of Marine Aerosol Number Concentrations Related with Vertical Winds)

  • 박성화;장상민;정운선;정종훈;이동인
    • 한국지구과학회지
    • /
    • 제33권3호
    • /
    • pp.259-268
    • /
    • 2012
  • 해양에서 발달하는 강수시스템의 연직풍에 따라 변동하는 해양성 에어러솔의 입경별 특성을 알아보기 위하여 마라도에서 남서쪽으로 419 km 지점에 위치한 이어도 해양종합과학기지에서 2009년 6월 8일부터 22일까지 에어러솔수 농도와 연직풍 관측을 실시하였다. 에어러솔 수 농도와 연직풍은 레이저입자계수기와 초음파 3차원 풍향 풍속계를 이용하였으며, 지상일기도, NCEP/NCAR 재분석자료, 라디오존데 자료를 이용하여 종관상태를 분석하였다. 그 결과, 전체적으로 1.0 ${\mu}m$ 이상의 크기의 에어러솔 수 농도 분포가 강수 중에 크게 변동하였으며, 하강류에서 상승류로 연직풍이 변함에 따라 크게 증가하였다. 강수 중에는 큰 입자(1.0 ${\mu}m$ 이상)의 에어러솔 수 농도가 약 5배 증가하였고, 이때 상승류가 약 0.4 $ms^{-1}$로 나타났다. 또한 축적모드(1.0 ${\mu}m$ 미만)와 큰 입자(1.0 ${\mu}m$ 이상)의 에어러솔 수 농도는 강수 중과 비교하여 약 45%와 92%가 제거되었다. 이는 독립된 해양지역에서의 큰 입자(1.0 ${\mu}m$ 이상) 에어러솔 수 농도 증가는 수평풍 보다는 상승류에 의해 크게 영향을 받고, 강수에 의한 세정효과도 나타났다. 따라서 해양경계층 내 에어러솔의 생성 및 발달 메커니즘에 상승류의 영향이 크게 기인함을 알 수 있었다.

소형 직화식 커피 로스터 이용 시 발생하는 미세먼지 특성 연구 (Characteristics of Particulate Matter Generated during the Operation of a Small Directly Fired Coffee Roaster)

  • 유다은;김승원
    • 한국산업보건학회지
    • /
    • 제30권2호
    • /
    • pp.236-248
    • /
    • 2020
  • Objectives: The purpose of this study was to evaluate the concentrations of particulate matter generated during coffee roasting and to study various factors affecting the concentrations. Methods: Differences in concentration levels were investigated based on various factors to understand the emission rates of particulate matter over time and to compare the mass and number concentrations according to their size. Sampling was performed in closed laboratories without the operation of air conditioning or ventilation. Optical Particle Sizer(OPS) was used as a measuring device. An OPS measures using a light-scattering method. Sampling was performed for sixty minutes at one-minute intervals. The background concentration was measured for about 30 minutes before starting of coffee roasting. The concentrations of particulate matter generated during coffee roasting were monitored until roasted coffee beans were removed from the roaster and cooled down. Several factors affecting the concentrations of particulate matter were investigated, which includes the origins of green beans, the roasting level, and the input amount of green beans. Results: The results of this study may be summarized as follows: 1) There was no difference in particulate matter concentration levels by the origin of the green beans, but a statistically significant difference in concentration levels by roasting level and the input amount of green beans; The higher the roasting level, the higher was the particulate matter concentration. The more green beans we put in the roaster, the higher were the concentrations; 2) The PM10 mass concentrations increased over time. The average concentration after roasting was higher than the average concentration during roasting; 3) In the distribution of mass and number concentration by particle diameter, the majority of particles was below 2.5 ㎛. Conclusions: Persons who work in roastery cafes can be exposed to high concentrations of particulate matter. Therefore, personal exposure and risk assessment should be conducted for roastery cafe workers.

Numerical Study of Entropy Generation with Nonlinear Thermal Radiation on Magnetohydrodynamics non-Newtonian Nanofluid Through a Porous Shrinking Sheet

  • Bhatti, M.M.;Abbas, T.;Rashidi, M.M.
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.468-475
    • /
    • 2016
  • In this article, entropy generation on MHD Williamson nanofluid over a porous shrinking sheet has been analyzed. Nonlinear thermal radiation and chemical reaction effects are also taken into account with the help of energy and concentration equation. The fluid is electrically conducting by an external applied magnetic field while the induced magnetic field is assumed to be negligible due to small magnetic Reynolds number. The governing equations are first converted into the dimensionless expression with the help of similarity transformation variables. The solution of the highly nonlinear coupled ordinary differential equation has been obtained with the combination of Successive linearization method (SLM) and Chebyshev spectral collocation method. Influence of all the emerging parameters on entropy profile, temperature profile and concentration profile are plotted and discussed. Nusselt number and Sherwood number are also computed and analyzed. It is observed that entropy profile increases for all the physical parameters. Moreover, it is found that when the fluid depicts non-Newtonian (Williamson fluid) behavior then it causes reduction in the velocity of fluid, however, non-Newtonian behavior enhances the temperature and nanoparticle concentration profile.

지역별 미세먼지 농도의 알레르기비염 외래이용에 대한 영향 분석 (Analysis on the Effects of Particular Matter Distribution on the Number of Outpatient Visits for Allergic Rhinitis)

  • 박주현;박영용;이은주;이광수
    • 보건행정학회지
    • /
    • 제30권1호
    • /
    • pp.50-61
    • /
    • 2020
  • Background: This study aims to analyze the effects of air pollutants, such as particular matter, to the number of outpatient visits for allergic rhinitis in eup, myeon, and dong administrative boundaries. Methods: Dependent variable was the number of outpatient visits for allergic rhinitis per 10,000 people by region. Independent variables were air pollutants such as PM10, PM2.5, SO2, O3, CO2, NO2, and temperature that estimated by using Kriging analysis in all eup, myeon, and dong boundaries. Panel analysis was applied for the analysis to prove the relation between outpatient visits and the concentration of air pollutants. Results: Analysis results showed that particular matter concentration varied by regions and season. Panel analysis showed that outpatient visits for allergic rhinitis had positive relationships with PM10, PM2.5, SO2, O3, and CO2 in all panel models. Conclusion: Regional variation of particular matter concentration should be considered in establishing regional policies for allergic rhinitis.

다층 다단 다공성 플레이트 시스템의 집진 특성 (Collection Characteristics of Multi-layer Multi-stage Porous Plate System)

  • 김일규;여석준
    • 동력기계공학회지
    • /
    • 제14권5호
    • /
    • pp.10-16
    • /
    • 2010
  • The main object of this study is to investigate the collection characteristics of multi-layer multi-stage porous plate system experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as inlet velocity, tube diameter, inlet concentration, and stage number, etc. In results, the pressure drop becomes 22 to $115mmH_2O$ with increment of stage number (1 to 5) of porous plate system at tube velocity 15 m/s and tube diameter ${\Phi}8$. In case of fly ash and 5 stage, the collection efficiency becomes 90.5 to 95.7% increasing the tube velocity 12 to 15 m/s at inlet concentration $3g/m^3$ and tube diameter ${\Phi}8$. Additionally, it is estimated that the collection efficiencies of 5 stage are 94.3, 95.6 and 99.1% for fly ash, steel dust and based power, respectively (${\Phi}8$ tube, $V_t$ = 12m/s, inlet concentration $3g/m^3$).

대기 모형에서의 벌크형 미세구름물리 모수화 방안 (Bulk-Type Cloud Microphysics Parameterization in Atmospheric Models)

  • 임교선
    • 대기
    • /
    • 제29권2호
    • /
    • pp.227-239
    • /
    • 2019
  • This paper reviews various bulk-type cloud microphysics parameterizations (BCMPs). BCMP, predicting the moments of size distribution of hydrometeors, parameterizes the grid-resolved cloud and precipitation processes in atmospheric models. The generalized gamma distribution is mainly applied to represent the hydrometeors size distribution in BCMPs. BCMP can be divided in three different methods such as single-moment, double-moment, and triple-moment approaches depending on the number of prognostic variables. Single-moment approach only predicts the hydrometeors mixing ratio. Double-moment approach predicts not only the hydrometeors mixing ratio but also the hydrometeors number concentration. Triple-moment approach predicts the dispersion parameter of hydrometeors size distribution through the prognostic reflectivity, together with the number concentrations and mixing ratios of hydrometeors. Triple-moment approach is the most time expensive method because it has the most number of prognostic variables. However, this approach can allow more flexibility in representing hydrometeors size distribution relative to single-moment and double-moment approaches. At the early stage of the development of BMCPs, warm rain processes were only included. Ice-phase categories such as cloud ice, snow, graupel, and hail were included in BCMPs with prescribed properties for densities and sedimentation velocities of ice-phase hydrometeors since 1980s. Recently, to avoid fixed properties for ice-phase hydrometeors and ad-hoc category conversion, the new approach was proposed in which rimed ice and deposition ice mixing ratios are predicted with total ice number concentration and volume.

Effect of Niacin Supplementation on Rumen Metabolites in Murrah Buffaloes (Bubalus bubalis)

  • Kumar, Ravindra;Dass, R.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권1호
    • /
    • pp.38-41
    • /
    • 2005
  • An experiment was conducted on 3 male rumen fistulated adult buffaloes fed on wheaten straw and concentrate mixture in a Latin square design to study the impact of niacin supplementation on rumen metabolites. Three animals were fed wheaten straw+concentrate mixture (group I, control), wheaten straw+concentrate mixture+100 ppm niacin (group II), and wheaten straw +concentrate mixture+200 ppm niacin (group III). After 21 days feeding, rumen liquor was drawn for 3 consecutive days at different time intervals (0, 2, 4, 6 and 8 h) to study the various rumen metabolites i.e., rumen pH, ammonia-N, total-N, trichloroacetic acid precipitable-N, non-protein nitrogen, total volatile fatty acids, their fractions and number of protozoa. Mean pH values in strained rumen liquor (SRL) of animals in 3 groups were 6.64, 6.71 and 6.67, indicating no statistically significant difference. Results revealed a significant (p<0.01) increase in TVFA concentration among the supplemented groups (group II and III) in comparison to control group. Mean TVFA concentration (meq/dl) was 9.75, 10.97 and 11.44 in 3 groups respectively. The highest concentration of TVFA was observed at 4 h and minimum at 0 h in all the 3 groups. The percentage of acetic, propionic, butyric and isobutyric acid was statistically similar among the three groups. The mean ammonia-N concentration (mg/dl SRL) was significantly (p<0.01) lower in group II (16.38) and group III (15.42) than group I (18.14). Ammonia-N concentration was higher (p<0.01) at 4 h as compared to all the time intervals. The mean total-N concentration (mg/dl SRL) was higher (p<0.01) in group II (74.16) and group III (75.47) as compared to group I (62.04). Total-N concentration was higher (p<0.01) at 4 h as compared to other time intervals and lowest value was recorded at 0 h.Concentration of TCA-ppt-N (mg/dl SRL) was significantly (p<0.01) lower in control group as compared to niacin supplemented groups. Mean value of NPN (mg/dl SRL) was significantly (p<0.01) lower in group III (23.21) as compared to group I (25.71), whereas groups I and II, and groups II and III were similar to each other. Total protozoa number (${\times}10^4$/ml SRL) ranged from 18.06 to 27.41 in group I, 20.89 to 38.44 in group II and 27.61 to 39.45 in group III. The mean protozoa number was significantly (p<0.01) higher in SRL of group II (27.60) and III (30.59) as compared to group I (22.48). It can be concluded from the study that supplementation of niacin in the diet of buffaloes had improved the rumen fermentation by decreasing the concentration of ammonia-N and increasing protein synthesis.

커먼레일 디젤엔진의 운전조건이 나노크기 입자상 물질 배출특성에 미치는 영향에 관한 실험적 연구 (Experimental Investigation of Nano-sized Particulate Matter Emission Characteristics under Engine Operating Conditions from Common Rail Diesel Engine)

  • 이형민;명차리;박심수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.508-514
    • /
    • 2010
  • 본 논문은 커먼레일 디젤엔진의 정속운전시 배출되는 나노크기의 입자상 물질을 분석하는데 초점을 두었다. 디젤산화촉매 후단에서 나노입자상 물질의 개수농도 저감수준은 크지 않았으나 매연여과장치 후단에서 분석한 결과 1,000배 정도 저감되는 결과를 확인하였다. 고속 고부하 조건에서는 매연여과장치의 자연재생 효과로 인해 입자상 물질은 증가하였다. 연료분사시기를 BTDC $6^{\circ}CA$ 에서 ATDC $4^{\circ}CA$까지 지각시킨 결과 입자상 물질의 개수농도는 감소하였지만 최지각 조건인 ATDC $9^{\circ}CA$에서는 증가하는 결과를 확인하였다. EGR 적용시 핵화모드 입자상 물질은 저감되는 경향을 보였으며 축적모든 입자는 증가하였다.

서울시 노원구 도로상 극미세입자 오염도 공간분포 특징 (Characteristics of spatial distribution of ultrafine particle number concentration on the roads of Nowon-gu, Seoul)

  • 이승복;이동훈;이승재;진현철;배귀남
    • 한국입자에어로졸학회지
    • /
    • 제7권1호
    • /
    • pp.21-30
    • /
    • 2011
  • The spatial distributions of air pollutants, in particular, ultrafine particles near traffic congestion roads at urban areas need to reduce human exposure levels for protecting public health. In this study, the number concentrations of ultrafine particles larger than 5 nm were measured every second during driving on the major roads of Nowon-gu, Seoul for 1.6 h using a mobile emission laboratory on October 5, 2010. The ultrafine particle number concentrations ranged from 7,009 to $265,600particles/cm^3$ with an average of $55,570particles/cm^3$, and these levels were comparable to concentrations of ultrafine particles larger than 3 or 7 nm on the arterial roads at urban areas in Los Angeles, USA and Zurich, Switzerland. It was frequently observed that the ultrafine particle number increased rapidly when vehicle speed was accelerated and it decreased sharply when vehicle speed was decelerated. The high peak events of ultrafine particle concentration larger than $200,000particles/cm^3$ were observed seven times during the measurement period. From the three repeated measurements during the short period of 50 min, it was concluded that the ultrafine particle number concentration on the road was significantly time-dependent. This on-road measurement approach can be utilized to manage vehicle-related air pollution in urban.