• Title/Summary/Keyword: Nuclear safety related

Search Result 519, Processing Time 0.023 seconds

Antecedents of self-reported safety behaviors among commissioning workers in nuclear power plants: The roles of demographics, personality traits and safety attitudes

  • Tao, Da;Liu, Zhaopeng;Diao, Xiaofeng;Tan, Haibo;Qu, Xingda;Zhang, Tingru
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1454-1463
    • /
    • 2021
  • Demographics, personality traits and attitudes are related to safety behaviors in varied workplaces, but their roles in nuclear power plants (NPPs) have not been fully understood. This study was conducted to explore the roles of a set of demographic, personality and attitudinal factors on self-reported safety behaviors (including safety participation and human errors) among NPP commissioning workers. Survey data were collected from 157 Chinese commissioning workers. Results showed that age and work experience were significantly associated with human errors, but not with safety participation. Neuroticism and conscientiousness were significantly related to human errors, while neuroticism, conscientiousness and agreeableness were significantly related to safety participation. Attitude towards questioning was observed as an antecedent of safety participation, and functioned as a mediating variable in the relation between conscientiousness and safety behaviors. The findings provide evidence-based implications on the design of diverse interventions and strategies for the promotion of safety behaviors in NPPs.

Development of classification criteria for non-reactor nuclear facilities in Korea

  • Dong-Jin Kim;Byung-Sik Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.792-799
    • /
    • 2023
  • Non-reactor nuclear facilities are increasing remarkably in Korea combined with advanced technologies such as life and space engineering, and the diversification of the nuclear industry. However, the absence of a basic classification guideline related to the design of non-reactor nuclear facilities has created confusion whenever related projects are carried out. In this paper, related domestic and international technical guidelines are reviewed to present the classification criteria of non-reactor nuclear facilities in Korea. Based on these criteria, the classification of structures, systems and components (SSCs) for safety controls is presented. Using the presented classification criteria, classification of a hot cell facility, a representative non-reactor nuclear facility, was performed. As a result of the classification, the hot cell facility is classified as the hazard category 3, accordingly, the safety class was classified as non-nuclear safety, the seismic category as non-seismic (RW-IIb), and the quality class as manufacturers' standards (S).

Finite element analysis of high-density polyethylene pipe in pipe gallery of nuclear power plants

  • Shi, Jianfeng;Hu, Anqi;Yu, Fa;Cui, Ying;Yang, Ruobing;Zheng, Jinyang
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.1004-1012
    • /
    • 2021
  • High density polyethylene (HDPE) pipe has many advantages over metallic pipe, and has been used in non-safety related application for years in some nuclear power plants (NPPs). Recently, HDPE pipe was introduced into safety related applications. The main difference between safety-related and non-safety-related pipes in NPPs is the design method of extra loadings such as gravity, temperature, and earthquake. In this paper, the mechanical behavior of HDPE pipe under various loads in pipe gallery was studied by finite element analysis (FEA). Stress concentrations were found at the fusion regions on inner surface of mitered elbows of HDPE pipe system. The effects of various factors were analyzed, and the influence of various loads on the damage of HDPE pipe system were evaluated. The results of this paper provide a reference for the design of nuclear safety-related Class 3 HDPE pipe. In addition, as the HDPE pipes analyzed in this paper were suspended in pipe gallery, it can also serve as a supplementary reference for current ASME standard on Class 3 HDPE pipe, which only covers the application for buried pipe application.

Beyond design basis seismic evaluation of underground liquid storage tanks in existing nuclear power plants using simple method

  • Wang, Shen
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2147-2155
    • /
    • 2022
  • Nuclear safety-related underground liquid storage tanks, such as those used to store fuel for emergency diesel generators, are critical components for safety of hundreds of existing nuclear power plants (NPP) worldwide. Since most of those NPP will continue to operate for decades, a beyond design base (BDB) seismic screening of safety-related underground tanks in those NPP is beneficial and essential to public safety. The analytical methodology for buried tank subjected to seismic effect, including a BDB seismic evaluation, needs to consider both soil-structure and fluid-structure interaction effects. Comprehensive analysis of such a soil-structure-fluid system is costly and time consuming, often subjected to availability of state-of-art finite element tools. Simple, but practically and reasonably accurate techniques for seismic evaluation of underground liquid storage tanks have not been established. In this study, a mechanics based solution is proposed for the evaluation of a cylindrical underground liquid storage tank using hand calculation methods. For validation, a practical example of two underground diesel fuel tanks in an existing nuclear power plant is presented and application of the proposed method is confirmed by using published results of the computer-aided System for Analysis of Soil Structural Interaction (SASSI). The proposed approach provides an easy to use tool for BDB seismic assessment prior to making decision of applying more costly technique by owner of the nuclear facility.

Safety Review Experience of Computerized Logic System for YGN 3 and 4

  • Yun, Won-Young;Kim, Dae-Il;Koh, Jong-Soo;Kim, Bok-Ryul;Oh, Sung-Hun;Lim, Jang-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.602-607
    • /
    • 1995
  • This article presents safety review experience of microprocessor-based Interposing Logic System(ILS) of Engineering Safety Feature Actuation System(ESFAS). The ILS is the first application of computerized logic design to safety system in Korean nuclear power plants without verification of the system reliability by proven technology concept. As a result of evaluation for the ILS, Korea Institute of Nuclear Safety(KINS) concluded that the microprocessor-based ILS is not acceptable in some features detailed enough to defend against software common mode failures(CMF). Therefore, we required licensee to install hardwired interlock signal configuration and a Hardwired Backup Panel to control safety-related equipment. We believe that the microprocessor-based ILS with the hardwired backup panel and inter-connection of interlock signal by hardwired configuration will improve the plant safety.

  • PDF

A Study on the Problems and Improvement of the Safety Management Law of Nuclear Facilities -Focused on Safety Management of Aquatic Products- (원자력시설 안전관리 법제의 문제점과 개선방안 연구 -수산물의 안전관리를 중심으로-)

  • Lee, Woo-Do
    • The Journal of Fisheries Business Administration
    • /
    • v.50 no.2
    • /
    • pp.23-40
    • /
    • 2019
  • The main purpose of this study is to analyze and examine the problems of the law systems of the safety and maintenance of nuclear facilities and to propose the improvements with respect to the related problems especialy focused on safety management of aquatic products. Therefore, the results of the paper would be helpful to build an effective management law system of safety and maintenance of nuclear facilities and fisheries products. The research methods are longitudinal and horizontal studies. This study compares domestic policies with foreign policies of nuclear plants and aquatic products. Using the above methods, examining the current system of nuclear-related laws and regulations, we have found that there exist 13 Acts including "Nuclear Safety Act", etc. Safety laws related on nuclear facilities have seven Acts including "Nuclear Safety Act", "the Act on Physical Protection and Radiological Emergency", "Radioactive waste control Act", "Act on Protective Action Guidelines against Radiation in the Natural Environment", "Special Act on Assistance to the locations of facilities for disposal low and intermediate level radioactive waste", "Korea Institute of Nuclear Safety Act". "Act on Establishment and Operation of the Nuclear Safety and Security Commission". The seven laws are composed of 119 legislations. They have 112 lower statute of eight Presidential Decrees, six Primeministrial Decrees and Ministrial Decrees, 92 administrative rules (orders), 6 legislations of local self-government aself-governing body. The concluded proposals of this paper are as follows. Firstly, we propose that the relationship between the special law and general law should be re-established. Secondly, the terms with respect to law system of safety and maintenance of nuclear plants should be redefined and specified. Thirdly, it is advisable to re-examine and re-establish the Law System for Safety and Maintenance of Nuclear Facilities. and environmental rights like the French Nuclear Safety Legislation. Lastly, inadequate legislation on the aquatic pollution damage should be re-established. It is necessary to ensure sufficient transparency as well as environmental considerations in the policy decisions of the Korean government and legislation of the National Assembly. It is necessary to further study the possibilities of accepting the implications of the French legal system as a legal system in Korea. In conclusion, the safety management of nuclear facilities is not only focused on the secondary industry and the tertiary industry centering on power generation and supply, but also on the primary industry, which is the food of the people. It is necessary to prevent damage to be foreseen. Therefore, it is judged that there should be no harm to the people caused by contaminated marine products even if the "Food Safety Law for Prevention of Radiation Pollution Damage" is enacted.

Geological Safety Evaluation and Monitoring of Nuclear Facility Sites in South Korea

  • Lee, Hyunwoo;Woo, Hyeon Dong;Chun, Hyun Ju;Im, Chang-Bock
    • The Journal of Engineering Geology
    • /
    • v.24 no.4
    • /
    • pp.609-613
    • /
    • 2014
  • The Korean Peninsula, located at the southeastern tip of the Eurasian Plate, is known to be tectonically stable, and no critical evidence has yet been found that would override the safety design of nuclear facilities in South Korea. Because a nuclear power plant, like other major social overhead capital facilities, could cause great damage to both the environment and society through an unexpected tectonic event, even one of extremely low probability, like the Fukushima accident, a defense-in-depth safety approach is required in geological and geotechnical site safety evaluation for nuclear projects. This paper introduces the regulatory procedures that are in place to confirm nuclear site safety and site monitoring (e.g., earthquakes and groundwater) systems applied to nuclear facilities in order to reduce inherent uncertainties within the site safety review of geological and seismological issues related with a NPP project.

Survivability assessment of Viton in safety-related equipment under simulated severe accident environments

  • Ryu, Kyungha;Song, Inyoung;Lee, Taehyun;Lee, Sanghyuk;Kim, Youngjoong;Kim, Ji Hyun
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.683-689
    • /
    • 2018
  • To evaluate equipment survivability of the polymer Viton, used in sealing materials, the effects of its thermal degradation were investigated in severe accident (SA) environment in a nuclear power plant. Viton specimens were prepared and thermally degraded at different SA temperature profiles. Changes in mechanical properties at different temperature profiles in different SA states were investigated. The thermal lag analysis was performed at calculated convective heat transfer conditions to predict the exposure temperature of the polymer inside the safety-related equipment. The polymer that was thermally degraded at postaccident states exhibited the highest change in its mechanical properties, such as tensile strength and elongation.