• Title/Summary/Keyword: Nuclear medicine study

Search Result 2,892, Processing Time 0.03 seconds

Study of hepatoprotective effect of Haegan-jeon through activation of nuclear factor erythroid 2-related factor 2 and optimization of herbal composition based on molecular mechanism (Nuclear factor erythroid 2-related factor 2 활성화를 통한 해간전(解肝煎)의 간세포 보호 효능 및 분자기전을 활용한 해간전(解肝煎) 구성 약물의 최적화 연구)

  • Kim, Jae Kwang;Jung, Ji Yun;Park, Sang Mi;Park, Chung A;Ku, Sae Kwang;Byun, Sung Hui;Cho, Il Je;Kim, Sang Chan
    • Herbal Formula Science
    • /
    • v.26 no.3
    • /
    • pp.207-221
    • /
    • 2018
  • Objectives : Present study investigated hepatoprotective effect of Haegan-jeon extract (HE) and tried to elucidate molecular mechanism involved. According to molecular mechanism, present study optimized herbal composition of HE (op-HE) and compared in vitro and in vivo hepatoprotective effects of op-HE to HE. Methods : For in vitro experiments, HepG2 cells were exposed to arachidonic acid (AA, $10{\mu}M$) and iron ($5{\mu}M$) for inducing oxidative stress. Cell viability, GSH contents, $H_2O_2$ production, mitochondrial membrane potential, immunoblot and reporter gene assay were performed to investigate cytoprotective effects and responsible molecular mechanisms. For in vivo experiments, hepatoprotective effect of HE and op-HE were assessed on $CCl_4-induced$ liver injury mice model. Results : HE pretreatment prevented AA+iron-mediated hepatocytes apoptosis. In addition, AA+iron-induced mitochondrial dysfunction, $H_2O_2$ production, glutathione depletion were reduced by HE pretreatment. In addition, nuclear factor erythroid 2-related factor 2 (Nrf2) phosphorylation, antioxidant response element (ARE)-driven reporter gene activity, and antioxidant genes expression were increased by HE. Based on reporter gene and MTT assays, we found that op-HE consisting three medicinal herbs also significantly increased transactivation of Nrf2 and reduced the AA+iron-mediated cytotoxicity. Moreover, in $CCl_4-induced$ liver injury mice model, HE-op had an ability to ameliorate $CCl_4-mediated$ increases in serum alanine transferase and aspartate aminotransferase activity, hepatic degeneration, inflammatory cell infiltration, and collagen deposition. Hepatoprotective effects of op-HE were comparable to those of HE. Conclusions : Present study suggests that op-HE as well as HE exhibit hepatoprotective effect against oxidative stress-mediated liver injury via Nrf2 activation.

Crossed Cerebellar Hyperperfusion on Ictal Tc-99m HMPAO Brain SPECT: Clinical Significance for Differentiation of Mesial or Lateral Temporal Lobe Epilepsy and Related Factors for Development (발작기 Tc-99m HMPAO 뇌 SPECT에 나타난 교차소뇌과혈류: 내외측 측두엽간질의 감별에 대한 임상적 의의와 발생에 영향을 주는 요인)

  • Park, Soon-Ah;Lee, Dong-Soo;Kim, Seok-Ki;Lee, Sang-Gun;Jang, Myoung-Jin;Sohn, Myung-Hee;Lim, Seok-Tae;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.312-321
    • /
    • 2000
  • Purpose: The aim of this study was to determine whether crossed cerebellar hyperperfusion (CCH) was helpful in discriminating mesial from lateral temporal lobe epilepsy (TLE) and what other factors were related in the development of CCH on ictal brain SPECT. Materials and Methods: We conducted retrospective analysis in 59 patients with TLE (M:41, F:18; $27.4{\pm}7.8$ years old; mesial TLE: 51, lateral TLE: 8), which was confirmed by invasive EEG and surgical outcome (Engel class I, II). All the patients underwent ictal Tc-99m HMPAO brain SPECT and their injection time from ictal EEG onset on video EEG monitoring ranged from 11 sec to 75 sec ($32.6{\pm}19.5sec$) in 39 patients. Multiple factors including age, TLE subtype (mesial TLE or lateral TLE), propagation pattern (hyperperfusion localized to temporal lobes, spread to adjacent lobes or contralateral hemisphere) and injection time were evaluated for their relationship with CCH using multiple logistic regression analysis Results: CCH was observed in 18 among 59 patients. CCH developed in 29% (15/51) of mesial TLE patients and 38% (3/8) of lateral TLE patients. CCH was associated with propagation pattern; no CCH (0/13) in patients with hyperperfusion localized to temporal lobe, 30% (7/23) in patients with propagation to adjacent lobes, 48% (11/23) to contralateral hemisphere. Multiple logistic regression analysis revealed that propagation pattern (p=0.01) and age (p=0.02) were related to the development of CCH. Conclusion: Crossed cerebellar hyperperfusion in ictal brain SPECT did not help differentiate mesial from lateral temporal lobe epilepsy. Crossed cerebellar hyperperfusion was associated with propagation pattern of temporal lobe epilepsy and age.

  • PDF

Effect of Medical Symbols on Memory Focusing on fMRI Empirical Studies (의료 심볼이 기억에 미치는 영향)

  • Myung-Chul, Park;Jae-Sang, You;Dong-Hyun, Oh;Yong-Gwon, Kim;Seok-Hwan, Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.99-106
    • /
    • 2023
  • This study measured the signal intensity (SI) of the hippocampus in relation to memory via fMRI analysis of 3 types of radiology symbols, 3 types of nuclear medicine symbols, and 3 types of oncology symbols among the most commonly employed medical symbols in hospitals. The following are the conclusions of the study. result of analyzing the SI values for symbol 1, symbol 2, and symbol 3 of the radiology, nuclear medicine, and oncology departments, symbol 3 had the highest SI value (1.72 ± 0.56) in radiology, symbol 2 had the highest SI value (1.69 ± 0.64) in nuclear medicine, and symbol 2 had the highest SI value (1.64 ± 0.63) in oncology. The overall mean of radiology, nuclear medicine, and oncology symbols was 1.62 ± 0.60 for nuclear medicine, 1.61 ± 0.59 for oncology, and 1.49 ± 0.49 for radiology. According to the overall SI measurement results, symbol 3 in radiology, symbol 2 in nuclear medicine, and symbol 2 in oncology were confirmed to have high SI values. If symbols with high SI values are used in a hospital, it is believed to be beneficial for navigating in any hospital.

Synthesis and in vitro evaluation of 99mTc-labeled tetraiodothyroacetic acid for tumor angiogenesis imaging

  • Kim, Hyunjung;Koo, Hyun-Jung;Choe, Yearn Seong
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.1
    • /
    • pp.3-9
    • /
    • 2020
  • Tetraiodothyroacetic acid (tetrac) is a derivative of thyroid hormone T4 and causes anti-angiogenesis by blocking T4 binding to integrin αvβ3. In this study, we synthesized [99mTc]Tc-Cys-Asp-Gly(CDG)-tetrac and evaluated it in vitro as a tumor angiogenesis imaging ligand. The CDG was conjugated to tetrac as a chelator for technetium-99m labeling. The cold vial containing CDG-tetrac, sodium glucoheptonate, and reducing agent was completed under nitrogen-filled atmospheric glove bag. [99mTc]Tc-CDG-tetrac was synthesized in quantitative yield by heating the cold vial with [99mTc]TcO4- at 100℃ for 30 min. In vitro serum stability of [99mTc]Tc-CDG-tetrac was measured by incubating the radioligand in 50% fetal bovine serum at 37℃ and analyzing the incubation mixture by radio-TLC, which showed high stability over 6 h (≥ 98%). Cell binding study was carried out by incubating [99mTc]Tc-CDG-tetrac with human umbilical vein endothelial (HUVE) cells at 37℃ for 6 h. The cell binding of the radioligand increased from 100% at 0.5 h to 293.7% at 6 h in a time-dependent manner. For blocking study, the cells were incubated with the radioligand in the presence of either tetrac (20 μM) or cRGDyK (20 μM) at 37℃ for 4 h. The results demonstrated that the cell binding of the radioligand was inhibited by tetrac (19.1%) or cRGDyK (35.6%), indicating specific binding of the radioligand to integrin αvβ3. Thus, this study suggests that [99mTc]Tc-CDG-tetrac may be a potential radioligand for tumor angiogenesis imaging.

Study on Confirmation of Solid-Meal Lag Phase of Gastric Emptying (고형음식물 위배출시 초기 정체기의 존재에 대한 연구)

  • Lee, Ji-Young;Lee, Kyoung-Soo;Kim, Chang-Guhn;Juhng, Seon-Kwan;Won, Jong-Jin;Nah, Yong-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.207-210
    • /
    • 1991
  • The purpose of this study was to examine the existence of a lag phase of gastric emptying of solid meals. We studied solid phase gastric emptying in 26 normal subject using continuous data aquisition for 30 minutes. Each ingested a 300 g meal containing $^{99m}Tc-labeled$ scrambled egg (solid 150g, milk 150 ml). Lag phase was determined by 1) inspection of the gastric emptying curve 2) time to a 2% decrease in stomach activity 3) the time of visual appearance of duodenal activity on computer image We concluded that solid meal lag phase exist.

  • PDF

Fusion of Gamma and Realistic Imaging (감마영상과 실사영상의 Fusion)

  • Kim, Yun-Cheol;Yu, Yeon-Uk;Seo, Young-Deok;Moon, Jong-Woon;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.78-82
    • /
    • 2010
  • Purpose: Recently, South Korea has seen a rapidly increased incidence of both breast and thyroid cancers. As a result, the I-131 scan and lymphoscintigraphy have been performed more frequently. Although this type of diagnostic imaging is prominent in that visualizes pathological conditions, which is similar to previous nuclear diagnostic imaging techniques, there is not much anatomical information obtained. Accordingly, it has been used in different ways to help find anatomical locations by transmission scan, however the results were unsatisfactory. Therefore, this study aims to realize an imaging technique which shows more anatomical information through the fusion of gamma and realistic imaging. Materials and Methods: We analyzed the data from patients who were examined by the lymphoscintigraphy and I-131 additional scan by Symbia Gamma camera (SIEMENS) in the nuclear medicine department of the National Cancer Center from April to July of 2009. First, we scanned the same location in patients by using a miniature camera (R-2000) in hyVISION. Afterwards, we scanned by gamma camera. The data we obtained was evaluated based on the scanning that measures an agreement of gamma and realistic imaging by the Gamma Ray Tool fusion program. Results: The amount of radiation technicians and patients were exposed was generated during the production process of flood source and applied transmission scan. During this time, the radiation exposure dose of technicians was an average of 14.1743 ${\mu}Sv$, while the radiation exposure dose of patients averaged 0.9037 ${\mu}Sv$. We also confirmed this to matching gamma and realistic markers in fusion imaging. Conclusion: Therefore, we found that we could provide imaging with more anatomical information to clinical doctors by fusion of system of gamma and realistic imaging. This has allowed us to perform an easier method in which to reduce the work process. In addition, we found that the radiation exposure can be reduced from the flood source. Eventually, we hope that this will be applicable in other nuclear medicine studies. Therefore, in order to respect the privacy of patients, this procedure will be performed only after the patient has agreed to the procedure after being given a detailed explanation about the process itself and its advantages.

  • PDF

Nucleophilic Fluorination Reactions in Novel Reaction Media for $^{18}F$-Fluorine Labeling Method ($^{18}F$-플루오린 표지를 위한 신개념 반응용매에서 친핵성 불소화 반응)

  • Kim, Dong-Wook;Jeong, Hwan-Jeong;Lim, Seok-Tae;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.91-99
    • /
    • 2009
  • Noninvasive imaging of molecular and biological processes in living subjects with positron emission tomography(PET) provides exciting opportunities to monitor metabolism and detect diseases in humans. Measuring these processes with PET requires the preparation of specific molecular imaging probes labeled with $^{18}F$-fluorine. In this review we describe recent methods and novel trends for the introduction of $^{18}F$-fluorine into molecules which in turn are intended to serve as imaging agents for PET study. Nucleophilic $^{18}F$-fluorination of some halo- and mesyloxyalkanes to the corresponding $^{18}F$-fluoroalkanes with $^{18}F$-fluoride obtained from an $^{18}O(p,n)^{18}F$ reaction, using novel reaction media system such as an ionic liquidor tert-alcohol, has been studied as a new method for $^{18}F$-fluorine labeling. Ionic liquid method is rapid and particularly convenient because $^{18}F$-fluoride in $H_2O$ can be added directly to the reaction media, obviating the careful drying that is typically required for currently used radiofluorination methods. The nonpolar protic tert-alcohol enhances the nucleophilicity of the fluoride ion dramatically in the absence of any kind of catalyst, greatly increasing the rate of the nucleophilic fluorination and reducing formation of byproducts compared with conventional methods using dipolar aprotic solvents. The great efficacy of this method is a particular advantage in labeling radiopharmaceuticals with $^{18}F$-fluorine for PETimaging, and it is illustrated by the synthesis of $^{18}F$-fluoride radiolabeled molecular imaging probes, such as $^{18}F$-FDG, $^{18}F$-FLT, $^{18}F$-FP-CIT, and $^{18}F$-FMISO, in high yield and purity and in shorter times compared to conventional syntheses.

Rapid Preparation and Quality Control of $^{99m}Tc$-ECD, $MAG_3$ and MIBI using Microwave Heating and Sep-Pak Cartridges (마이크로웨이브와 Sep-Pak 카트리지를 이용한 $^{99m}Tc$-ECD, $MAG_3$, MIBI의 신속한 제조 및 정도관리)

  • Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.430-438
    • /
    • 1999
  • Purpose: We evaluated a rapid preparation procedures for the labeling and quality control of $^{99m}Tc$-ECD, $MAG_3$, and MIBI using microwave heating and Sep-Pak cartridges. Materials and Methods: $^{99m}Tc$ labeling of ECD, $MAG_3$, and MIBI kit preparation was performed according to the package inserts with microwave heating modification. Heating time was 10-15 sec, and heating was performed with 3 mm plastic bottle with screw cap to prevent radiation contamination. Labeling efficiency was obtained with $C_{18}$ or Alumina N Sep-Pak cartridges. Results: The radiochemical purity of $93{\sim}96%$ for $^{99m}Tc$-ECD and $95{\sim}99%$ for $^{99m}Tc$-MIBI was obtained using Alumina N Sep-Pak cartridge. The optimum irradiation time of microwave method for 3 ml $^{99m}Tc$-labeled radiopharmaceutical solution was 10 sec for $^{99m}Tc$-ECD and $^{99m}Tc$-MIBI, and 15 sec for $^{99m}Tc-MAG_3$. The results of quality control data with Sep-Pak cartridges were well correlated with TLC method. The total preparation time of these radiopharmcaeuticals was $5{\sim}6min$ including quality control procedure. Conclusion: This study demonstrates that radiopharmaceuticals preparation by microwave heating and quality control by Sep-Pak cartridges can be efficiently utilized as an alternative to the recommended method by manufacturer's manual.

  • PDF

Development of Adaptive Spatial Filter to Improve Noise Characteristics of PET Images (PET 영상의 잡음개선을 위한 적응적 공간 필터 개발)

  • Woo, S. K.;Choi, Y.;Im, K. C.;Song, T. Y.;Jung, J. H.;Lee, K. H.;Kim, S. E.;Choe, Y. S.;Park, C. C.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.253-261
    • /
    • 2002
  • A spatially adaptive falter was formulated to imrove PET image qualify and the Performance of the filter was evaluated using simulation and phantom and human PET studies. In the proposed filter. if a pixel was identified as the edge Pixel, the Pixel value was Preserved. Otherwise a Pixel was replaced by the mean of the pixel values weighted by 2:7: 2. A Pixel was identified as the edge Pixel. if it satisfies the following conditions : the number of ADs (absolute difference between center and neighborhood pixels) which is smaller than THl (($pix_max{\times}0.1/log_2(NPM)$, NPM : mean of 6 neighborhood pixels excluding minimum and maximum) is 8-k and the number of ADs which is lager than TH2 ($NPM{\times}0.1$) is k. where k : 2, 3, …, 6. The results of this study demonstrate the superior performance of the Proposed titter compared to Gaussian fitter, weight median filter and subset averaged median filter. The proposed tittering method is simple but effective in increasing uniformity and contrast with minimal degradation of spatial resolution of PET images and thus. is expected to Provide improved diagnositc quality PET images .