• 제목/요약/키워드: Nuclear and radiation

Search Result 2,727, Processing Time 0.033 seconds

Field Application of Phased Array Ultrasonic Testing for Structural Weld Overlay on Dissimilar Welds of Pressurizer Nozzles (가압기 노즐 이종금속 용접부의 구조적 오버레이 용접부에 대한 위상배열 초음파기법의 현장 적용)

  • Kim, Jin-Hoi;Kim, Yongsik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.4
    • /
    • pp.268-274
    • /
    • 2015
  • Weld overlay was first used in power plants in the US in the early 1980s as an interim method of repairing the welds of flawed piping joints. Weld overlaid piping joints in nuclear power plants must be examined periodically using ultrasonic examination technology. Portable phased array ultrasonic technology has recently become available. Currently, the application of preemptive weld overlays as a mitigation technique and/as a method to improve the examination surface condition for more complex configurations is becoming more common. These complex geometries may require several focused conventional transducers for adequate inspection of the overlay, the original weld, and the base material. Alternatively, Phased array ultrasonic probes can be used to generate several inspection angles simultaneously at various focal depths to provide better and faster coverage than that possible by conventional methods. Thus, this technology can increase the speed of examinations, save costs, and reduce radiation exposure. In this paper, we explain the general sequence of the inspection of weld overlay and the results of signal analysis for some PAUT (phased array ultrasonic testing) signals detected in on-site inspections.

Sequence Divergence and Phylogenetic Investigation of the Nymphalidae (Lepidoptera: Papilionoidea) Occurring in South Korea

  • Wan, Xinlong;Kim, Min Jee;Cho, Youngho;Jun, Jumin;Jeong, Heon Cheon;Lee, Kwang Youll;Kim, Iksoo
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.26 no.2
    • /
    • pp.95-112
    • /
    • 2013
  • As a first step toward understanding the divergence and relationships of the Nymphalidae (Lepidoptera: Papilionoidea) occurring in South Korea, cytochrome oxidase subunit I (COI), 16S ribosomal RNA (16S rRNA), and elongation factor-$1{\alpha}$ (EF-$1{\alpha}$) that comprise 3,501-3,716 bp were either sequenced (55 species) or the sequences were obtained from GenBank (23 species). The concatenated sequence divergence of six nymphalid subfamilies ranked in the following order: Danainae (10.3%), Satyrinae (9.5%), Limenitidinae (8.0%), Apaturinae (7.0%), Nymphalinae (6.7%), and Heliconiinae (6.2%). As has been reported in previous large scale international studies, the subfamilial relationships of (((((Limenitidinae + Heliconiinae) + (Nymphalinae + Apaturinae)) + Satyrinae) + Libytheinae) + Danainae) were also confirmed, except for the switched positions between Danainae and Libytheinae, and supported all subfamilies and tribe monophylies. Unlikely consistent phylogenetic relationships among genera within the majority of tribes in Nymphalidae, a conflicting relationship within the subfamily Apaturinae was obvious, presenting Apatura as sister to either Mimathyma or (Mimathyma + (Sephisa + (Hestina + Sasakia))), and both of these relationships are unconventional. Within the subfamily Limenitidinae, the genus Neptis was consistently revealed as a paraphyletic with respect to the genus Aldania, requiring further taxonomic investigation of the genus. Although limited, current sequence information and phylogenetic relationships are expected to be helpful for further studies.

Safety Assessment on the Incineration Disposal of Regulation Exempt Waste by RESRAD Code (RESRAD 코드를 활용한 규제해제 폐기물 소각처분에 대한 안정성 평가)

  • Kim, Hui-Gyeong;Han, Sang-Wook;Park, Su-Ri;Kim, Byung-Jick
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.67-73
    • /
    • 2018
  • In this paper, risk assessment was conducted to verify self - disposal requirements by landfill for exempted incineration ash by using Resrad Ver.6.5 computer code. The result of risk assessment by landfill for the incineration by-product is that individual dose is $6.91{\times}10^{-2}{\mu}Sv\;y-1$ and collective dose is $3.475{\times}10^{-7}man-Sv\;y-1$. It proved that the result meets reference dose of individual dose $10{\mu}Sv\;y-1$ and collective dose 1 man-Sv y-1 for general public. According to the current 'Nuclear Safety Commission Notice [No. 2014-3]', it states that the exempted wastes can be disposed of by incineration, landfill and recycling. However, most of recently documents and papers related to exempted wastes are disposed of by landfill and recyling and it could not confirm the case of exempt by incineration. If the national consensus is derived and treating the waste by using process of incineration is activated, it could be considered to treat low level of radiation wastewater and activated carbon excluded from exempted waste because of nuclide $^3H$ and $^{14}C$.

A Study on the Surface Roughness Behavior of Reactor Vessel Stud Holes in APR1400 Nuclear Power Plants (APR1400 원자로 용기 스터드 홀의 표면거칠기 거동에 관한 연구)

  • Kim, Dong Il;Kim, Chang Hun;Moon, Young Jun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.62-70
    • /
    • 2019
  • The APR1400 reactor may be operated for a long time under high temperature and pressure conditions, causing damage to the stud holes and causing stud bolts and holes to stick. The present practice is to manually remove the anti-sticking agent and foreign matter remaining in the APR1400 reactor stud hole and to visually check the surface condition of the thread to check the damage status of the threads. In the case of the APR1400 reactor stud holes, manually cleaning the threads increases the risk of radiation exposure and operator's fatigue. To avoid this, the autonomous mobile robot is used to automatically clean the reactor stud holes. The purpose of this study is to optimize the cleaning performance of the mobile robot by looking at the behavior of the surface roughness of the stud surface cleaned by the brush attached to the mobile robot due to changes in brush material, thickness of wire, and rotation speed. A microscopic approach to the surface roughness of the flank is needed to investigate the effects of the newly proposed brush of the autonomous mobile robot on the thread holes. According to this experiment, it is reasonable to use STS brush rather than Carbon one. Optimal operating conditions are derived and the safety of APR1400 reactor stud holes maintenance can be improved.

Current Status and Future Perspective of PET (PET 이용 현황 및 전망)

  • Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) defecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3,015 and 4,414 in 1996,1997,1998,1999 and 2000, respectively. The application in cardiac disorders is minimal, and among various neuropsychiatric diseases, patients with epilepsy or dementia can benefit from PET studios. Recently, we investigated brain mapping and neuroreceptor works. PET is not a key application for evaluation of the cardiac patients in Korea because of the relatively low incidence of cardiac disease and less costly procedures such as SPECT can now be performed. The changes in the application of PET studios indicate that, initially, brain PET occupied almost 60% in 1995, followed by a gradual decrease in brain application. However, overall PET use in the diagnosis and management of patients with cancer was up to 63% in 2000. The current medicare coverage policy in the USA is very important because reimbursement policy is critical for the promotion of PET. In May 1995, the Health Care Financing Administration (HCFA) began covering the PET perfusion study using Rubidium-82, evaluation of a solitary pulmonary nodule and pathologically proven non-small cell lung cancer. As of July 1999, Medicare's coverage policy expanded to include additional indications: evaluation of recurrent colorectal cancer with a rising CEA level, staging of lymphoma and detection of recurrent or metastatic melanoma. In December of 2001, National Coverage decided to expand Medicare reimbursement for broad use in 6 cancers: lung, colorecctal, lymphoma, melanoma, head and neck, and esophageal cancers; for determining revascularization in heart diseases; and for identifying epilepsy patients. In addition, PET coverage is expected to further expand to diseases affecting women, such as breast, ovarian, uterine and vaginal cancers as well as diseases like prostate cancer and Alzheimer's disease.

Comparative study of 82Sr separation/purification methods used at Brookhaven National Laboratory and ARRONAX

  • Ha, Yeong Su;Yoon, Sang-Pil;Kim, Han-Sung;Kim, Kye-Ryung
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.2
    • /
    • pp.71-78
    • /
    • 2019
  • Nuclear imaging is one of the most powerful measures for non-invasive diagnosis of myocardial vascular disease. Radionuclide such as 13N, 15O, 201Tl and 82Rb is used for the measurement of cardiac blood flow. 13N, 15O and 201Tl are produced in cyclotrons while 82Rb is obtained from generator. Rubidium (Rb), an alkali ion, behaves biologically like potassium, and accumulates in myocardial tissue. Rb has rapid blood clearance profile which allows the use of 82Rb with a short physical half-life of 75 s for non-invasive evaluation of regional myocardial perfusion. There are several advantages of 82Rb over other radioisotopes. An ultra-short half-life significantly reduces the exposure of patients to radiation and allows to repeat injections for studying the effects of medical intervention. As a positron emitter, 82Rb allows positron emission tomography (PET) imaging which have shown superior diagnostic performances. 82Rb can be produced from generator by decay of its parent 82Sr. However, the preparation of 82Sr is difficult, because appropriate purity is required to meet the specification of the product. Recently reported procedure from ARRONAX research institute showed that a Chelex-100 resin is sufficient for this purpose and additional column is not necessary. Whereas Brookhaven National Laboratory (BNL) procedure contains three ion exchange resin separation, including Chelex-100 resin. Currently, since 82Sr production site is non-existent in Korea, Korea Atomic Energy Research Institute (KAERI) has plan to produce 82Sr within specifications. We compared 82Sr purification procedures reported from ARRONAX and BNL to investigate the most suitable procedure for our conditions.

Dietary iodine intake and the association with subclinical thyroid dysfunction in male workers (직장인 남성에서 식이 요오드섭취량과 불현성 갑상선기능이상과의 연관성)

  • Kim, Eun-Hye;Choi, Tae-in;Park, Yoo-Kyoung
    • Journal of Nutrition and Health
    • /
    • v.45 no.3
    • /
    • pp.218-228
    • /
    • 2012
  • The prevalence rate of thyroid dysfunction (hypothyroidism and hyperthyroidism) has increased within the Korean population and seems to be affected by iodine dietary habits. Some studies reported that the prevalence of thyroid dysfunction increase both in the area of iodine deficiency and excess. In this study, we tried to discover the difference in iodine intake, anthropometric measurements, and blood parameters between male subjects with or without subclinical thyroid dysfunction. A total of 5,249 subjects (Euthyroid: 4706, SubHypo: 454, SubHyper: 89) were used in this study. There were no significant differences in BMI, body fat, visceral fat, waist circumference, SBP, DBP, total cholesterol, HDL-cholesterol, LDL-cholesterol, TG, fasting serum glucose, HbA1c, alcohol intake, however significant differences were noticed in both age and smoking status. Through a food frequency questionnaire (FFQ), iodine intake per day was estimated. The average iodine intake was similar (SubHypo $392.9{\pm}279.0{\mu}g$, Euthyroid $376.5{\pm}281.7{\mu}g$, SubHyper $357.3{\pm}253.8 {\mu}g$) among groups. The main source of iodine intake was eggs (52.8%, 54.2%, 52.4%) followed by milk (16.3%, 15.8%, 17.8%), then sea mustard & sea tangle (12.4%, 11.9%, 11.6%). The prevalence of subclinical hypothyroidism and subclinical hyperthyroidism was higher in subjects whose intake was higher than the recommended nutrient intake (RNI). These results suggest that the excess consumption of iodine intake may act as one of the risk factors regarding thyroid dysfunction in Korea. Therefore, an adequate amount of iodine intake is necessary in order to prevent subclinical thyroid dysfunction and clinical thyroid dysfunction.

Factors affecting the Intention of transfering of Radiology Technologists to Different Institutions (방사선사의 전직의사와 관련된 요인분석)

  • Kim, Chang-Ho;Yu, Seung-Hum;Lee, Sun-Hee;Sohn, Tae-Yong
    • Korea Journal of Hospital Management
    • /
    • v.1 no.1
    • /
    • pp.37-55
    • /
    • 1996
  • This study attempts to analyze the factors affecting the intention of transferring to another hospitals among radiology technologists. 344 cases were reviewed in 5 university hospitals and 1 general hospital. Self-administered questionaire were given to study the socioeconomic characteristics, working conditions, job satisfaction level, and the reasons for transfer among the technologists. The major findings were as follows : 1. Job position and hospital characteristics had a statistically significant relationship with the intention of transferring to another hospital. 2. Those who were not satisfied with their salaries and promotional opportunity showed a higher tendency towards to transfer. 3. Those who were less satisfied with the opportunity for developing the personal ability and had the negative attitude on their job showed a higher tendency to transfer. 4. Those who did not sustain good relationship with their superiors and co-workers scored high on the tendency to transfer. 5. In the result of mutiple regression, recognition of radiation hazard, job satisfaction, satisfaction with salary levels, job attitude were significantly related to transfer. The above indicate that besides economic incentives, job satisfaction and organizational culture to promote their ability and form a good relationship with organization members were very important to decrease the intention of transfer. Since these results represent only 6 hospitals from a limited area, more hospitals nationwide, especially small and medium-sized institutions where there is a high turnover rate of employment, need to be examined in order to investigate the various factors that affect the intention of transferring.

  • PDF

Application of MARSSIM for Final Status Survey of the Decommissioning Project (해체사업의 최종현황조사를 위한 MARSSIM 적용)

  • Hong, Sang-Bum;Lee, Ki-Won;Park, Jin-Ho;Chung, Un-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.2
    • /
    • pp.107-111
    • /
    • 2011
  • The release of a site and building from regulatory control is the final stage of the decommissioning process. The MARSSIM (Multi-Agency Radiation Survey and Site Investigation Manual) provides overall framework for conducting data collection for a final status survey to demonstrate compliance with site closure requirements. The KAERI carried out establishing a final status survey by using the guidance provided in the MARSSIM for of a site and building of the Korea Research Reactor. The release criteria for a site and building were set up based on these results of the site specific release levels which were calculated by using RESRAD and RESRAD-Build codes. The survey design for a site and building was classified by using the survey dataset and potential contamination. The number of samples in each survey unit was calculated by through a statistical test using the collected data from a scoping and characterization survey. The results of the final status survey were satisfied the release criteria based on an evaluation of the measured data.

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.