• Title/Summary/Keyword: Nuclear Energy

Search Result 7,857, Processing Time 0.037 seconds

Digital n-γ Pulse Shape Discrimination in Organic Scintillators with a High-Speed Digitizer

  • Kim, Chanho;Yeom, Jung-Yeol;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.53-63
    • /
    • 2019
  • Background: As neutron fields are always accompanied by gamma rays, it is essential to distinguish neutrons from gamma rays in the detection of neutrons. Neutrons and gamma rays can be separated by pulse shape discrimination (PSD) methods. Recently, we performed characterization of a stilbene scintillator detector and an EJ-301 liquid scintillator detector with a high-speed digitizer DT5730 and investigated optimized PSD variables for both detectors. This study is for providing a basis for developing fast neutron/gamma-ray dual-particle imager. Materials and Methods: We conducted PSD experiments using stilbene scintillator and EJ-301 liquid scintillator and evaluated neutron and gamma ray discriminability of each PSD method with a $^{137}Cs$ gamma source and a $^{252}Cf$ neutron source. We implemented digital signal processing techniques to apply two PSD methods - the charge comparison (CC) method and the constant time discrimination (CTD) method - to distinguish neutrons from gamma rays. We tried to find optimized PSD variables giving the best discriminability in a given experimental condition. Results and Discussion: For the stilbene scintillator detector, the charge comparison method and the constant time discrimination method both delivered the PSD FOM values of 1.7. For the EJ-301 liquid scintillator detector, both PSD methods delivered the PSD FOM values of 1.79. With the same PSD variables, PSD performance was excellent in $300{\pm}100keVee$, $500{\pm}100keVee$, and $700{\pm}100keVee$ energy regions. This result shows that we can achieve an effective discrimination of neutrons from gamma rays using these scintillator detector systems. Conclusion: We applied both PSD methods to a stilbene and a liquid scintillator and optimized the PSD performance represented by FOM values. We observed a good separation performance of both scintillators combined with a high-speed digitizer and digital PSD. These results will provide reference values for the dual-particle imager we are developing, which can image both fast neutrons and gamma rays simultaneously.

Stress Singularity Behaviour in the Frictional Complete Contact Problem of Three Bodies (세 물체 간 마찰 완전 접촉 문제의 응력 특이성 거동)

  • Kim, Hyung-Kyu
    • Tribology and Lubricants
    • /
    • v.35 no.4
    • /
    • pp.229-236
    • /
    • 2019
  • This study investigates the stress singularity that occurs at the contact edge of three bodies in a frictional complete contact. We use the asymptotic analysis method, wherein we constitute an eigenvalue problem and observe the eigenvalue behavior, which we use to obtain the order of the stress singularity. For the present geometry of three bodies in contact, a contact between a cracked indenter and half plane is considered. This is a typical geometry of the PCMI problem of a nuclear fuel rod. Thus, this paper, specifically presents the characteristics of the PCMI problem from the perspective of stress singularity. Consequently, it is noted that the behavior of the stress singularity varies with the difference in the crack angle, coefficient of friction, and material dissimilarity, as is observed in a frictional complete contact of two bodies. In addition, we find that the stress singularity changes essentially linearly with respect to the coefficient of friction, regardless of the variation in the crack angle and material dissimilarity. Concurrently, we find the order of singularity to be 0.5 at a certain coefficient of friction, irrespective of the crack angle, which we also observe in the crack problem of a homogeneous and isotropic body. The order of singularity can also exceed 0.5 in the frictional complete contact problem of three bodies. This implies that the propensity for failure when three bodies are in frictional complete contact can be even worse than that in case of a failure induced by a crack.

Effects of Bombycis Corpus on Male Osteoporosis (백강잠(白殭蠶)이 남성 골다공증에 미치는 영향)

  • Kim, Ho Hyun;Ahn, Sang Hyun;Park, Sun Young
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.56-62
    • /
    • 2019
  • To investigate the effect of Bombycis Corpus on male osteoporosis, we performed Dual Energy X-Ray Absorptiometry(DEXA) and histochemical methods. The animals were used ICR-based male mice of 8 weeks and 50 weeks, respectively. ICR male mice at 8 weeks were used in the control group, and ICR male mice at 50 weeks were used in aging group and Bombycis Corpus group(BC group). In the aging group, 0.5 ml of distilled water was administered once a day for 6 months. In BC group, Bombycis Corpus(0.78g/kg) was dissolved in distilled water for 6 months once a day. As a result, Bombycis Corpus decreased bone loss, increased bone density by reducing the loss of bone matrix in the femur due to aging, and increased osteoblast - induced osteopontin(OPN) and osteocalcin(OPC) positivite reaction. In addition, administration of Bombycis Corpus decreased Reaction of activation of nuclear factor kappa B ligand(RANKL) positive reaction, increased osteoprotegerin(OPG) positive reaction, and decreased matrix metalloproteinase-3(MMP-3) and 8-hydroxy-2'-deoxyguanosine(8-OHdG) positivite reaction. Taken together, Bombycis Corpus increases the activity of osteoblasts, inhibits osteoclast function, promotes osteoblast function, inhibits bone tissue degradation, and inhibits bone loss due to oxidative stress. It was observed that Bombycis Corpus reduced bone loss and increased bone density caused by aging to improve male osteoporosis. Therefore, Bombycis Corpus may be used as a preventive and therapeutic agent for male osteoporosis.

Increase of Cardiometabolic Biomarkers Among Vehicle Inspectors Exposed to PM0.25 and Compositions

  • Ramdhan, Doni Hikmat;Kurniasari, Fitri;Tejamaya, Mila;Fitri, Aidila;Indriani, Aisyah;Kusumawardhani, Adinda;Santoso, Muhayatun
    • Safety and Health at Work
    • /
    • v.12 no.1
    • /
    • pp.114-118
    • /
    • 2021
  • Background: Exposure to particulate matter (PM) emitted from vehicle exhaust might disrupt systemic function and elevate the risk of cardiovascular disease. In this study, we examined the changes of cardiometabolic biomarkers among vehicle inspectors exposed daily to PM0.25 and components. Methods: This cross-sectional study was conducted at two vehicle inspection centers, Pulogadung and Ujung Menteng, located in East Jakarta, Indonesia. The exposed respondents were 43 workers from vehicle inspection centers, and the unexposed group consisted of 22 staff officers working in the same locations. Vehicle exhaust particulate matter was measured for eight hours using a Leland Legacy personal pump attached to a Sioutas Cascade Impactor. The used filters were 25 and 37-mm quartz filters. The particulate matter concentration was analyzed using a gravimetric method, whereas trace elements were analyzed using energy dispersive X-ray fluorescence. An EEL Smoke Stain Reflectometer analyzed black carbon. Results: The personal exposure concentrations of PM0.25 were 10.4-fold higher than those in unexposed groups. Calcium and sulfur were the major components in the obtained dust, and their levels were 3.3- and 7.2-fold higher, respectively, in the exposed group. Based on an independent-samples t-test, high-density lipoprotein, triglyceride, HbA1c, total immunoglobulin E, high-sensitivity C-reactive protein, tumor necrosis factor-alpha, and nitric oxide levels were significantly different between the groups. Conclusions: In summary, it was suggested that PM0.25 exposure from vehicle exhaust might affect cardiometabolic biomarkers change.

A Study on Water-Proof Characteristics of a Stainless Steel Mesh by Electrochemical Etching Process (전기화학 에칭 공정을 이용한 스테인리스 스틸 메쉬의 방수 특성 연구)

  • Lee, Chan;Kim, Ji Min;Kim, Hyungmo
    • Tribology and Lubricants
    • /
    • v.37 no.5
    • /
    • pp.189-194
    • /
    • 2021
  • A straightforward, yet effective surface modification method of stainless steel mesh and its interesting anti-wetting characteristics are reported in this study. The stainless steel mesh is electrochemically etched, and the specimen has both micro and nano-scale structures on its surface. This process transforms the two types of mesh specimens known as the regular and dense specimens into hydrophobic specimens without applying any hydrophobic chemical coating process. The fundamental wettability of the modified mesh is analyzed through a dedicatedly designed experiment to investigate the waterproof characteristics, for instance, the penetration threshold. The waterproof characteristics are evaluated in a manner that the modified mesh resists as high as approximately 2.7 times the pressure compared with the bare mesh, i.e., the non-modified mesh. The results show that the penetration threshold depends primarily on the advancing contact angles, and the penetration stop behaviors are affected by the contact angle hysteresis on the surfaces. The findings further confirm that the inexpensive waterproof meshes created using the proposed straightforward electrochemical etching process are effective and can be adapted along with appropriate designs for various practical applications, such as underwater devices, passive valves, and transducers. In general, , additional chemical coatings are applied using hydrophobic materials on the surfaces for the applications that require water-repelling capabilities. Although these chemical coatings can often cause aging, the process proposed in this study is not only cost-effective, but also durable implying that it does not lose its waterproof properties over time.

In Vitro Experiment to Evaluate 137Cs Dissolution in the Digestion Process of Mushrooms

  • Nishiono, Kanoko;Yamanishi, Hirokuni
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.4
    • /
    • pp.154-162
    • /
    • 2020
  • Background: Several studies have reported that wild mushrooms contain high amounts of radioactive cesium (137Cs). After the Fukushima Daiichi Nuclear Power Plant Accident, a significantly high concentration of 137Cs has been detected in wild mushrooms, and their consumption may be the cause of the chronic internal exposure of local consumers to radioactivity. Therefore, an accurate evaluation of the internal radioactivity resulting from mushroom ingestion is needed. Materials and Methods: The 137Cs elution rate through the cooking and digestion stages was evaluated using in vitro experiments. The edible mushroom Pleurotus djamor was taken as a sample for the experiments. The mushrooms were cultivated onto solid media containing 137Cs. We evaluated the internal dose based on the actual conditions using the elution rate data. For various cooking methods, the results were compared with those of other wild edible mushrooms. Results and Discussion: From the elution experiment through cooking, we proved that 25%-55% of the 137Cs in the mushrooms was released during soaking, boiling, or frying. The results of a simulated digestion experiment after cooking revealed that almost all the 137Cs in the ingested mushrooms eluted in the digestive juice, regardless of the cooking method. The committed effective dose was reduced by 20%-75% when considering the dissolution through the cooking process. Conclusion: We found that cooking lowers 137Cs concentration in mushrooms, therefore reducing the amount of radioactivity intake. Besides, since there were differences between mushroom types, we demonstrated that the internal exposure dose should be evaluated in detail considering the release of 137Cs during the cooking stages.

High-Performance Compton SPECT Using Both Photoelectric and Compton Scattering Events

  • Lee, Taewoong;Kim, Younghak;Lee, Wonho
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1393-1398
    • /
    • 2018
  • In conventional single-photon emission computed tomography (SPECT), only the photoelectric events in the detectors are used for image reconstruction. However, if the $^{131}I$ isotope, which emits high-energy radiations (364, 637, and 723 keV), is used in nuclear medicine, both photoelectric and Compton scattering events can be used for image reconstruction. The purpose of our work is to perform simulations for Compton SPECT by using the Geant4 application for tomographic emission (GATE). The performance of Compton SPECT is evaluated and compared with that of conventional SPECT. The Compton SPECT unit has an area of $12cm{\times}12cm$ with four gantry heads. Each head is composed of a 2-cm tungsten collimator and a $40{\times}40$ array of CdZnTe (CZT) crystals with a $3{\times}3mm^2$ area and a 6-mm thickness. Compton SPECT can use not only the photoelectric effect but also the Compton scattering effect for image reconstruction. The correct sequential order of the interactions used for image reconstruction is determined using the angular resolution measurement (ARM) method and the energies deposited in each detector. In all the results of simulations using spherical volume sources of various diameters, the reconstructed images of Compton SPECT show higher signal-to-noise ratios (SNRs) without degradation of the image resolution when compared to those of conventional SPECT because the effective count for image reconstruction is higher. For a Derenzo-like phantom, the reconstructed images for different modalities are compared by visual inspection and by using their projected histograms in the X-direction of the reconstructed images.

Development of X-Ray Array Detector Signal Processing System (X-Ray 어레이 검출 모듈 신호처리 시스템 개발)

  • Lim, Ik-Chan;Park, Jong-Won;Kim, Young-Kil;Sung, So-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1298-1304
    • /
    • 2019
  • Since the 9·11 terror attack in 2001, the Maritime Logistics Security System has been strengthened and required X-ray image for every imported cargos from manufacturing countries to United States. For scanning cargos, the container inspection systems use high energy X-rays for examination of contents of a container to check the nuclear, explosive, dangerous and illegal materials. Nowadays, the X-ray cargo scanners are established and used by global technologies for inspection of suspected cargos in the customs agency but these technologies have not been localized and developed sufficiently. In this paper, we propose the X-ray array detector system which is a core component of the container scanning system. For implementation of X-ray array detector, the analog and digital signal processing units are fabricated with integrated hardware, FPGA logics and GUI software for real-time X-ray images. The implemented system is superior in terms of resolution and power consumption compared to the existing products currently used in ports.

Development of an Objective Judgement Procedure for Determining Involvement of Violation-Type Unsafe Acts caused Industrial Accidents (사고 유발 불안전행동의 위반 여부에 대한 객관적 판단절차 개발)

  • Lim, Hyeon Kyo;Ham, Seung Eon;Bak, Geon Yeong;Lee, Yong Hee
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.2
    • /
    • pp.35-42
    • /
    • 2022
  • When an accident occurs, the associated human activity is typically regarded as a "human error," or a temporal deviation. On the other hand, if the accident results in a serious loss or if it evokes a social issue, the person determined to be responsible may be punished with a "violation" of related laws or regulations. However, as Heinrich stated, it is neither appropriate nor reasonable in terms of probability theory and cognitive science to distinguish whether it is a "human error" or a "violation" with a criterion of resultant accident severity. Nonetheless, some in society get on the social climate to strengthen regulations on workers who have caused accidents, especially violations. This response can present a social issue due to the lack of systematic judgment procedure which distinguishes violations from human errors. The purpose of this study was to develop an objective and systematic procedure to assess whether workers' activities which induced industrial accidents should be categorized as violations rather than human errors. Various analysis techniques for the determination of violation procedure were investigated and compared using an analysis approach method. An appropriate technique was not found, however, for judging the culpability of intentional violations. As an alternative, this study developed the process of creating violations, based on cognitive procedure, as well as the criteria to determine and categorize an activity as a violation. In addition, the developed procedure was applied to cases of industrial accidents and nuclear power plant issues to test its practical applicability. The study demonstrated that the proposed model could be used to determine the existence of a violation even in the case of multiple workers who work simultaneously.

The Short-Chain Fatty Acid Receptor GPR43 Modulates YAP/TAZ via RhoA

  • Park, Bi-Oh;Kim, Seong Heon;Kim, Jong Hwan;Kim, Seon-Young;Park, Byoung Chul;Han, Sang-Bae;Park, Sung Goo;Kim, Jeong-Hoon;Kim, Sunhong
    • Molecules and Cells
    • /
    • v.44 no.7
    • /
    • pp.458-467
    • /
    • 2021
  • GPR43 (also known as FFAR2 or FFA2) is a G-protein-coupled receptor primarily expressed in immune cells, enteroendocrine cells and adipocytes that recognizes short-chain fatty acids, such as acetate, propionate, and butyrate, likely to be implicated in innate immunity and host energy homeostasis. Activated GPR43 suppresses the cAMP level and induces Ca2+ flux via coupling to Gαi and Gαq families, respectively. Additionally, GPR43 is reported to facilitate phosphorylation of ERK through G-protein-dependent pathways and interacts with β-arrestin 2 to inhibit NF-κB signaling. However, other G-protein-dependent and independent signaling pathways involving GPR43 remain to be established. Here, we have demonstrated that GPR43 augments Rho GTPase signaling. Acetate and a synthetic agonist effectively activated RhoA and stabilized YAP/TAZ transcriptional coactivators through interactions of GPR43 with Gαq/11 and Gα12/13. Acetate-induced nuclear accumulation of YAP was blocked by a GPR43-specific inverse agonist. The target genes induced by YAP/TAZ were further regulated by GPR43. Moreover, in THP-1-derived M1-like macrophage cells, the Rho-YAP/TAZ pathway was activated by acetate and a synthetic agonist. Our collective findings suggest that GPR43 acts as a mediator of the Rho-YAP/TAZ pathway.