• Title/Summary/Keyword: Nuclear Counting

Search Result 192, Processing Time 0.034 seconds

이성체쌍의 열중성자포획단면적비 측정

  • Park, Hy-Eil;Kim, Heon-Jun;Lee, Chul
    • Nuclear Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.340-344
    • /
    • 1972
  • Isomeric ratios were measured for the capture of thermal neutron by $^{79}$ Br, $^{80}$ Se, $^{103}$ Rh, $^{115}$ In and $^{133}$ Cs as well as those of epi-cadmium neutron by $^{79}$ Br, $^{80}$ Se and $^{l33}$Cs. The measurements were performed by analysing decay curves obtained by ${\gamma}$-ray spectrometry after irradiation. The counting efficiency curve was determined by using the calibrated standard sources with overall uncertainties of about 1%. Isomeric ratios, given in $\sigma$ high spin/($\sigma$ high spin + $\sigma$ low spin), of $^{80, 80m}$Br, $^{81,81m}$Se, $^{014, 104m}$Rh, $^{116,116m}$In and $^{134, 134m}$Cs produced by thermal neutron activation were found to be 0.21$\pm$0.01, 0.14$\pm$0.02, 0.12$\pm$0.02, 0.69$\pm$0.07 and 0.058$\pm$0.004, respectively, Those values of $^{80, 80m}$Br, $^{81,81m}$Se, and $^{134, 134m}$Cs Produced by epi-cadmium neutron were found to be 0.19$\pm$0.02, 0.29$\pm$0.02 and 0.074$\pm$0.011, respectively. The experimental values obtained were compared with the theoretical values deduced from the statistical model. There were the general agreements between the theory and the experiment.t.

  • PDF

Diagnostic Significance of the Blood Disappearance Rate of $^{131}I$-Rose Bengal and of $^{198}Au$ colloid in Hepatobiliary Diseases (간담도질환(肝膽道疾患)에 있어서 $^{131}I$-Rose Bengal 및 $^{198}Au$ 교질(膠質)의 혈중소실율(血中消失率)의 진단적(診斷的) 의의(意義)에 관(關)한 연구(硏究))

  • Chun, Young-Kyoon;Koh, Chang-Soon;Hahn, Shim-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.5 no.2
    • /
    • pp.7-18
    • /
    • 1971
  • The liver function test was performed by means of two radioisotope tracer techniques in 20 normal subjects and in 63 patients with hepatobiliary diseases. The blood disappearance rates of $^{131}I$-rose bengal and of $^{198}Au$ colloid were determined by external counting method. The hepatocellular function and the hepatic blood flow were estimated from the observed data and the results were compared with those of the conventional liver function tests. The results obtained were as follows: 1. The mean blood disappearance half time of $^{131}I$-rose bengal was $6.6{\pm}0.63$ minutes in normal control, $17.7{\pm}6.93$ in cirrhosis of the liver, $16.6{\pm}4.80$ in acute hepatitis, and $14.7{\pm}3.46$ in obstructive jaundice. It was markedly prolonged in the hepatobiliary diseases as compared with the normal control, but there was no significant difference among the hepatobiliary diseases. 2. The mean blood disappearance half time of $^{198}Au$ colloid was $4.0{\pm}0.66$ minutes in normal control, $9.8{\pm}3.42$ in cirrhosis of the liver, $4.4{\pm}0.82$ in acute hepatitis, and $5.0{\pm}1.42$ in obstructive jaundice. The difference between cirrhosis of the liver and normal control Was statistically significant. However, there was no definite difference among acute hepatitis, obstructive jaundice, and normal control. The mean blood disappearance rate constant (K value) was $0.177{\pm}0.028/minute$ in normal control. In cirrhosis of the liver, it was markedly decreased which was suggestive of the reduced hepatic blood flow. 3. The ratio of $^{131}I$-rose bengal blood disappearance half time to $^{198}Au$ colloid disappearance half time was $1.68{\pm}0.20$ in normal control, $1.82{\pm}0.31$ in cirrhosis of the liver, $3.80{\pm}0.82$ in acute hepatitis, and $3.01{\pm}0.54$ in obstructive jaundice. The ratios in acute hepatitis and obstructive jaundice were remarkably higher than those in normal control and cirrhosis of the liver. 4. There was a significant correlation between the blood disappearance half time of $^{131}I$-rose bengal and that of $^{198}Au$ colloid in cirrhosis of the liver. 5. In cirrhosis of the liver, the blood disappearance half times of $^{131}I$-rose bengal and of $^{198}Au$ colloid were inversely correlated to the serum albumin level. In acute hepatitis, there was a good positive correlation between the blood disappearance half time of $^{131}I$-rose bengal and the serum transaminase activities. In obstructive jaundice, the blood disappearance half time of $^{131}I$-rose bengal was correlated to the serum bilirubin level.

  • PDF

Radioanalytical and Spectroscopic Characterizations of Hydroxo- and Oxalato-Am(III) Complexes (방사분석과 분광학을 이용한 Am(III) 가수분해와 옥살레이트 착물 화학종 연구)

  • Kim, Hee-Kyung;Cho, Hye-Ryun;Jung, Euo Chang;Cha, Wansik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.4
    • /
    • pp.397-410
    • /
    • 2018
  • When considering the long-term safety assessment of spent-nuclear fuel management, americium is one of the most radio-toxic actinides. Although spectroscopic methods are widely used for the study of actinide chemistry, application of those methods to americium chemistry has been limited. Herein, we purified $^{241}Am$ to obtain a highly pure stock solution required for spectroscopic studies. Quantitative and qualitative analyses of purified $^{241}Am$ were carried out using liquid scintillation counting, and gamma and alpha radiation spectrometry. Highly sensitive absorption spectrometry coupled with a liquid waveguide capillary cell and time-resolved laser fluorescence spectroscopy were employed for the study of Am(III) hydrolysis and oxalate (Ox) complexation. $Am^{3+}$ ions under acidic conditions exhibit maximum absorbance at 503 nm, with a molar absorption coefficient of $424{\pm}8cm^{-1}{\cdot}M^{-1}$. $Am(OH)_3(s)$ colloidal particles formed under near neutral pH conditions were identified by monitoring the absorbance at around 506-507 nm. The formation of ${Am(Ox)_3}^{3-}$ was detected by red-shifts of the absorption and luminescence spectra of 4 and 5 nm, respectively. In addition, considerable enhancements of the luminescence intensities were observed. The luminescence lifetime of ${Am(Ox)_3}^{3-}$ increased from 23 to 56 ns, which indicates that approximately six water molecules are replaced by carboxylate ligands in the inner-sphere of the Am(III). These results suggest that ${Am(Ox)_3}^{3-}$ is formed through the bidentate coordination of the oxalate ligands.

Assessment of natural radioactivity in soil and olive mill pomace utilizing nal (TI) gamma-ray spectrometry and low background alpha/beta counting system

  • Amani Kraishan;Mohammad Abu Shayeb;Hafedh Belmabrouk;Ahmad Ali Husein Qwasmeh;Muzahir Ali Baloch
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1925-1931
    • /
    • 2024
  • The study conducted in the northwest region of Jordan aimed to assess the levels of natural radioactivity in soil and olive mill pomace (OMP) samples. The researchers used Nal (TI) gamma-ray spectrometry to measure the activity concentrations of 226Ra, 232Th, 40K, and 137Cs in the samples. The average activity concentrations of 226Ra, 232Th, 40K, and 137Cs in the soil samples were found to be 18.624 ± 5.82, 12.276 ± 5.728, 518.33 ± 212.57, and 0.140 ± 0.09 (Bq, kg-1), respectively. In the OMP samples, the average activity concentrations of 226Ra, 232Th, and 40K were 7.272 ± 4.386, 3.454 ± 1.503, and 169.997 ± 81.873 (Bq kg-1), respectively, and no 137Cs was detected. The study also investigated fundamental parameters associated with radon, specifically the radon emanation coefficient (RnEC) and radon mass exhalation rate (Ex). The RnEC values ranged from 0.621 to 0.78 (Bq kg-1), with an average value of 0.71 ± 0.06 (Bq kg-1). The estimated Ex from the soil samples ranged from 65.83 to 124.86 (mBq kg-1h-1), with an average value of 99.74 ± 21.73 (mBq kg-1h-1). Regarding radiological hazards, the study examined various parameters, including radium equivalent activity, external and internal hazard indices, gamma and alpha indices, absorbed gamma dose rate, and excess lifetime cancer risk. All of these assessed values were found to be below the worldwide recommended limits for radiological safety. Additionally, the study analyzed the concentrations of gross alpha and gross beta radioactivities in soil and OMP samples. The soil samples had an average gross alpha activity of 4.642 ± 1.04 (Bq kg-1) and an average gross beta activity of 48.13 ± 14.50 (Bq kg-1). The OMP samples showed an average gross alpha activity of 0.32 ± 0.27 (Bq kg-1) and an average gross beta activity of 59.19 ± 12.94 (Bq kg-1). Overall, the obtained results are crucial for evaluating the radiological risks associated with natural radioactivity in the northwest region of Jordan. The findings establish baseline data for comparison and reference for radioactivity levels in the environment.

Detection of HCV-RNA by Reverse Transcription Polymerase Chain Reaction Using Biotinylated and Radioiodinated Primers (역전사 중합효소 연쇄반응(RT-PCR)에 의한 HCV-RNA의 검출 : Biotin 및 방사성옥소 표지 Primer로 구성된 Kit의 이용)

  • Ryu, Jin-Sook;Moon, Dae-Hyuk;Cheon, Jun-Hong;Chung, Yoon-Young;Park, Hung-Dong;Chung, Young-Hwa;Lee, Young-Sang
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.220-226
    • /
    • 1994
  • This study was performed to evaluate the clinical applicability of the reverse transcription polymerase chain reaction (RT-PCR ) kit of HCV-RNA using biotinylated and radioiodinated primers. Study subjects were 118 patients with positive anti-HCV. HCV-RNA in patient's serum was extracted by guanidium thiocyanate method. After first amplification, the product was reamplified by primers labelled with biotin and I-125. The final amplification product was defected by counting the radioactivity after incubation in avidin coated tubes. In 51 samples, the test was repeated for evaluation of reproducibility. This new method was also compared with conventional RT-PCR methods in 34 samples from patients with chronic liver disease. The results were as follows ; 1) HCV-RNA was positive in 85(97%)of 88 patients with chronic liver disease, and in 23 (73%) of 30 patients with normal liver function. 2) In comparison with conventional method, HCV-RNA was detected in 32(94%) of 34 patients with new method, whereas in 27(79%) of the same group with conventional method. 3) Repeated test with new method in 52 samples demonstrated 82% of concordant result. In conclusion, new method with biotinylated and radioiodinated primers was more sensitive than conventional method. However, great care must be taken for quality control because there were considerable interassay variation and possiblity of false positivity and false negativity.

  • PDF

Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease (관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jeong-Sun;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.354-361
    • /
    • 2008
  • Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : $63{\pm}11$ years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/89% vs MPS: 65%/82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability.

Comparison of the Diagnostic Performance of $^{14}C$-urea Breath Test According to Counting Method for the Diagnosis of Helicobacter pylori Infection (Helicobacter pylori 감염 진단 시 $^{14}C$-요소호기검사의 계수측정 방법에 따른 진단성능 비교)

  • Kim, Min-Woo;Lim, Seok-Tae;Lee, Seung-Ok;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.21-25
    • /
    • 2005
  • Purpose: $^{14}C$-urea breath test (UBT) is a non-invasive and reliable method for the diagnosis of Helicobacter pylori (HP) infection. In this study, we evaluated the diagnostic performance of a new and rapid $^{14}C$-UBT (Heliprobe method), which was equipped with $Geiger-M\ddot{u}ller$ counter and compared the results with those obtained by using the conventional method. Materials and Methods: Forty-nine patients with dyspepsia underwent gastroduodenoscopy and $^{14}C$-UBT. A 37 KBq $^{14}C$-urea capsule was administered to patients and breath samples were collected. In Heliprobe method, patients exhaled into a Hellprobe BreathCard for 10 min. And then the activities of the BreathCard were countered using Heliprobe analyzer. In the conventional method, results were countered using liquid scintillation counter. During gastroduodenoscopy, 18 of 49 patients were underwent biopsies. According to these histologic results, we evaluated the diagnostic performance of two different methods and compared them. Also we evaluated the concordant and disconcordant rates between them. Results: In all 49 patients, concordant rate of both conventional and Heliprobe methods was 98% (48/49) and the discordant rate was 2% (1/49). Thirteen of 18 patients to whom biopsies were applied, were found to be HP positive on histologic results. And both Heliprobe method and conventional method classified 13 of 13 HP-positive patients and 5 of 5 HP-negative patients correctly (sensitivity 100%, specificity 100%, accuracy 100%). Conclusion: The Heliprobe method demonstrated the same diagnostic performance compared with the conventional method and was a simpler and more rapid technique.

Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image (PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가)

  • Park, Sun-Myung;Lee, Hyuk;Hong, Gun-Chul;Chung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.41-46
    • /
    • 2011
  • Purpose: The result of exam using an imaging device is very closely related with the image quality. Moreover, this image quality can be changed according to the condition of image acquisition and evaluation method. In this study, we evaluated the image quality according to the difference of pre-set method in PET/CT image. Materials & Methods: PET/CT Discovery STe16 (GE Healthcare, Milwaukee, USA), Chest PET phantom (Experiment 1) and 94 NEMA phantom (Experiment 2) were used. Phantom were filled with $^{18}F$-FDG maintaining hot sphere and background ratio to 4:1. In the case of experiment 1, we set the radio activity concentration on 3.5, 6.0, 8.6 kBq/mL. In the case of experiment 2, we set the radio activity concentration on 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL. All experiments were performed with the time-set method for 2 minutes 30 seconds per frame and the count-set method with one hundred million counts in 3D mode after CT transmission scan. For the evaluation of the image quality, we compared each results by using the NECR and SNR. Results: In the experiment 1, both the NECR and SNR were increased as radioactivity concentration getting increased. The NECR was shown as 53.7, 66.9, 91.4. and SNR was shown as 7.9, 10.0, 11.7. Both the NECR and SNR were increased in time-set method. But the count-set method's pattern was not similar with the time-set method. The NECR was shown as 53.8, 69.1, 97.8, and SNR was shown as 14.1, 14.7 14.4. The SNR was not increased in count-set method. In experiment 2, results of both the NECR and SNR were shown as 45.1, 70.6, 95.3, 115.6, 134.6, 162.2 and 7.1, 8.8, 10.6, 11.5, 12.7, 14.0. These results were shown similar patten with the experiment 1. Moreover, when the count-set method was applied, the NECR was shown as 42.1, 67.3, 92.1, 112.2, 130.7, 158.7, and SNR was shown as 15.2, 15.9, 15.6, 15.4, 15.5, 14.9. The NECR was increased but SNR was not shown same pattern. Conclusion: Increment of administered radioactivity improves the quality of image unconcerned with the pre-set method. However, NECR was not influenced by increment of total acquisition counts through simple increasing scan duration without increment of administered activity. In case of count-set method, the SNR was shown similar value despite of increment of radioactivity. So, the administered activity is more important than the scan duration. And we have to consider that evaluation of image quality using only SNR may not be appropriate.

  • PDF

Recommended Methods for Surface Counting to Determine Sites of Red Cell Destruction - A Report by the Panel on Diagnostic Applications of Radioisotopes in Haematology of the International Committee for Standardization in Hematology

  • The Korea Society of Nuclear Medicine The Korea Society of Nuclear Medicine
    • The Korean Journal of Nuclear Medicine
    • /
    • v.8 no.1_2
    • /
    • pp.57-62
    • /
    • 1974
  • 이 논문(論文)은 1973년(年) ICSH주최로 열린 panel에서 적혈구파괴(赤血球破壞) 장소(場所)를 결정(決定)하기 위한 생체(生體) 체표계측법(醫表計測法)의 표준화(標準化)에 관(關)한 토론(討論) 결과(結果)를 초록(抄錄)한 것이다. 체표계측(體表計測)은 체외(體外)에서 계측기(計測器)를 이용(利用)하여 각(各) 장기(臟器)에서의 방사표지물질(放射標識物質)의 분포(分布) 및 시간경과(時間經過)에 따른 변화(變化)를 측정(測定)하는 것으로서 $^{51}Cr$를 사용(使用)하여 적혈구수명(赤血球壽命)을 측정(測定)할 때 간(肝), 비(脾), 심장(心臟)의 방사능(放射能)을 계측(計測)한다. 이 방법(方法)은 각(各) 장기(臟器)에서의 적혈구파괴(赤血球破壞)의 정도(程度)를 예측할 수 있다. 특(特)히 용혈성(溶血性) 빈혈환자(貧血患者)에서 비장적출(脾臟摘出) 여부를 결정(決定)하는데 도움이 된다. 이 panel에서는 주(主)로 오차(誤差)의 원인(原因)이 되는 여러가지 요인(要因)에 대(對)하여 토론(討論)하였으며 일반적으로 다음과 같은 것에 의견(意見)의 일치(一致)를 보았다. 즉(卽) 비장(脾臟)의 위치(位置)는 $^{99m}Tc$로 비주사(脾走査)를 실시하여 결정(決定)하는것이 좋고, $^{51}Cr$은 체중(體重) 1kg당 $1.5{\mu}Ci$를 사용하여, 계측기(計測器)는 NaI crystal(직경이 5cm이상, 두께가 3.75cm이상)의 scintillation doctor를 사용하고, 계측(計測)은 $^{51}Cr$로 표지(標識)된 적혈구(赤血球) 주입후(注入後) 15분(分) 이후(以後)에 하고 다음날 계측(計測)한 후(後) 2주(週) 동안에 적어도 6번 계측(計測)한다. Data 처리는 excess count법(法)과 비(脾)와 간(肝)의 비(比)로서하는 것이 좋다.定値)에 차이(差異)가 있어 그 결과(結果)의 해석(解釋) 및 비교(比較) 검토(檢討)에 적지않은 난점(難點)이 생겨 표준화(標準化)된 공통적(共通的)인 방법(方法)의 사용(使用)이 중요(重要)하다는 사실(事實)이 인식(認識)되게 되었다. 1966년(年) 호주(濠洲)의 Sydney에서 개최(開催)되었든 제11차(第11次) 국제혈액학회(國際血學會)때 열린 제4차(第4次) International Committee for Standardization in Haematology(ICSH)에서 Diagnostic Applications of Radioisotopes in Haematology에 관(關)한 expert panel을 갖을것을 의결(議決)하여 다음과 같은 12명(名)의 위원(委員)이 결정(決定)되었으며 위원회(委員會)의 의장(議長)에 Dr. Szur, 총무(總務)에 Dr. Glass가 각각(各各) 선임(選任)되었다. 그간(間) 1967년(年) 영경(英京) London에서 첫 회합(會合)이 있은후(後) New York, Vienna(IAEA후원(後援)) Brthesda(NIH후원(後援))에서 전문위원회(專門委員會)를 갖고 적혈구수명측정법(赤血球壽命測定法)에 관(關)한 의견(意見)의 일치(一致)를 보았다. ICSH와 국제혈액학회(國際血學會)에서는 이번에 결정(決定)된 적혈구수명측정법(赤血球壽命測定法)을 널리 소개(紹介)하며, 측정법(測定法)과 얻어진 결과(結果)의 해석(解釋)에 표준화(標準化)를 기(期)할 목적(目的)으로 이에 연관성(聯關性)있는 전문지(專門誌)에 게재(揭載)할 것을 요청(要請) 받었기에 이에 전문(全文)을 소개(紹介)하는 바이다. 이들은 방사성(放射性) chromium 법(法)의 모든 세부적(細部的)인 면(面)을 표준화(標準化)하고 있으며 그간(間) 가장 논란(論難)의 대상(對象)이 되었던, $^{51}Cr$-표지방법(標識方法)에 있어서의 세가지 변법(變法),

  • PDF

Can the C-14 Urea Breath Test Reflect the Extent and Degree of Ongoing Helicobacter pylori Infection? (C-14 요소호기검사의 정량치가 Helicobacter pylori 감염 정도를 반영할 수 있을까?)

  • Lim, Seok-Tae;Sohn, Myung-Hee;Lee, Seung-Ok;Lee, Soo-Teik;Jeong, Myoung-Ja
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.61-68
    • /
    • 2001
  • Purpose: The C-14 urea breath test (C-14 UBT) is the most specific noninvasive method to detect Helicobacter (H) pylori infection. We investigated if the C-14 UBT can reflect the presence and degree of H. pylori detected by gastroduodenoscopic biopsies (GBx). Materials and methods: One hundred fifty patients (M:F=83:67, age $48.6{\pm}11.2$ yrs) underwent C-14 UBT, rapid urease test (CLO test) and GBx on the same day. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (137 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive (${\geq}200dpm$), Intermediate ($50{\sim}199dpm$) or negative (<50 dpm). The results of CLO tests were classified as positive or negative according to color change. The results of GBx on giemsa stain were graded 0 (normal) to 4 (diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT results with GBx grade as a gold standard. Results: In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.5%, 88.4%, 97.1%, 88.4% and 91.3%, respectively. However, the CLO test had sensitivity, specificity, PPV, NPV and accuracy of 83.2%, 81.4%, 91.8%, 81.4% and 82.7%, respectively. The quantitative values of the C-14 UBT were $45{\pm}27$ dpm in grade 0, $707{\pm}584dpm$ in grade 1, $1558{\pm}584dpm$ in grade 2, $1851{\pm}604dpm$ in grade 3, and $2719{\pm}892dpm$ in grade 4. A significant correlation (r=0.848, p<0.01) was found between C-14 UBT and the grade of distribution of H. pylori infection on GBx with giemsa stain. Conclusion: We conclude that the C-14 UBT is a highly accurate, simple and noninvasive method for the diagnosis of ongoing H. pylori infection and reflects the degree of bacterial distribution.

  • PDF